| Plan Review Stops For Permit 07050602 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2008-07-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-07-25 |
Time |
16:47 |
Rev Time |
0.55 |
| Received By |
jwitmer |
Date |
2008-07-25 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2008-07-25 16:47:53 | RESTAMP |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-02-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-02-26 |
Time |
07:43 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2008-02-26 |
Time |
07:42 |
Sent To |
|
|
| Notes |
| 2008-02-26 07:43:40 | REV# 2 DATED 11/16/07 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-12-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-12-12 |
Time |
14:41 |
Rev Time |
1.22 |
| Received By |
jwitmer |
Date |
2007-12-12 |
Time |
14:39 |
Sent To |
FIRE |
|
| Notes |
| 2007-12-12 14:42:42 | BUILDING PLAN REVIEW | | | PERMIT: 07050602 | | | ADD: 224 DATURA ST. | | | CONT: WESTOWER COMMUNICATIONS | | | TEL: (561)762-5652 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2007 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVISIONREVIEW | | | ACTION: DENIED | | | | | | 1A)COVERSHEET "T1" IS NOT RAISED SEAL. | | | PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS | | | PREPARED BY THE DESIGN PROFESSIONAL AND BEING FILED FOR | | | PUBLIC RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE | | | DESIGN PROFESSIONAL AFFIXED TO THE DOCUMENT. | | | FL ADMIN CODE 61G15-23.002 ENGINEERS | | | | | | 2) 106.1.2 ADDITIONAL INFORMATION REQUIRED, EIETHER ONE | | | OF TWO SITUATIONS HAVE OCCURED. | | | 2A) THE REVISION COVER SHEET SUBMITTED INDICATE PAYMENT | | | FOR ONLY FOUR SHEETS WHEREAS 16 SHEETS HAVE BEEN | | | SUBMITTED. THIS MEANS THERE IS AN ADDITIONAL BALANCE | | | DUE $120.00 AND ONLY (5) SHEETSINDICATING A | | | REVISION # 2, WHERE ARE THE ADDITIONAL REVISIONS? | | | PAYMENT IS DUE SINCE ELECTRIC, BUILDING AND FIRE TOOK | | | TIME TO REVIEW WHERE THE ADDITIONAL UNMARKED REVISIONS | | | ARE? | | | 2B) 106.1.2 ADDITIONAL INFORMATION REQUIRED, THE SECOND | | | SENARIO IS ONLY 5 SHEETS SHOULD HAVE BEEN SUBMITTED | | | INDICATING A REVISION# 2 AND ONLY THE 5 SHEETS SHOULD | | | HAVE BEEN SUBMITTED SAVING THE CONTRACTOR | | | AS WELL AS THE REVIEWERS VALUABLE TIME AND A SAVINGS TO | | | THE CONTRACTOR? 102.1* WHERE, IN ANY SPECIFIC CASE, | | | DIFFERENT SECTIONS OF THIS CODE SPECIFY DIFFERENT | | | MATERIALS, METHODS OF CONSTRUCTION OR OTHER | | | REQUIREMENTS, THE MOST RESTRICTIVE SHALL GOVERN. WHERE | | | THERE IS A CONFLICT BETWEEN A GENERAL REQUIREMENT AND A | | | SPECIFIC REQUIREMENT, THE SPECIFIC | | | REQUIREMENT SHALL BE APPLICABLE. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-09-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-09-16 |
Time |
19:10 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-09-16 |
Time |
18:59 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-06-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-06-13 |
Time |
14:32 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2007-06-13 |
Time |
13:51 |
Sent To |
PC |
|
| Notes |
| 2007-06-13 14:48:42 | BUILDING PLAN REVIEW | | | PERMIT: 07050602 | | | ADD: 224 DATURA ST | | | CONT: MACTEC ENGINEERING & CONSULTING | | | TEL: (561)601-0068 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | 2)) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE | | | FILED WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF | | | THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS | | | NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE | | | RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: | | | 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT | | | THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3) PLEASE SEE ELECTRICAL COMMENTS FOR LICENSING | | | REQUIREMENTSSIGNATURES, SEALS, TITLEBLOCKSAND | | | CERTIFICATE OF AUTHORIZATION. | | | | | | 4) SHEET T1 ONLY PROVIDES A PORTION OF THE INFORMATION | | | REQUIRED FOR WIND. 2004 FL. BLD CODE 1603.1.4 THE | | | FOLLOWING INFORMATION RELATED TO WIND | | | SHALL BE SHOWN ON THE CONSTRUCTION | | | DRAWINGS, | | | 1)- BASIC WIND SPEED, MPH | | | 2)- WIND IMPORTANCE FACTOR, & BUILDING CATEGORY( ASCE | | | 7-02) TABLE 1-1 OPERATION CENTERS REQUIRED FOR | | | EMERGENCY RESPONSE IV/ 1.15 AS PART OF THE DESIGN | | | CRITERIA. | | | 3)- WIND EXPOSURE | | | 4)- INTERNAL PRESSURE COEFFICIENT, | | | 5)- COMPONENTS & CLADDING, THE DESIGN | | | WIND PRESSURES IN TERMS OF PSF. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-03-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-03-04 |
Time |
18:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-03-04 |
Time |
18:38 |
Sent To |
PC |
|
| Notes |
| 2008-03-04 18:38:30 | ELEC REV #1 OK. STAMPED SHEETS |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-12-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-12-03 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-12-03 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2007-12-03 14:05:39 | | | | | | | | | | | | | ** DENIED REVISION ** | | | | | | | | | 1) NOTE: PLEASE SEE SOME SHEETS DO NOT INDICATE ANY | | | REVISIONS, CLOUDS OR TRIANGLES. | | | PLEASE SEE TITLE BLOCKS HAVE ALSO NOT BEEN REVISED. | | | PLEASE SUBMIT REVISIONS INTENDED FOR REVIEW. | | | | | | 2) NOTE: PLEASE SEE SHEET T-1 WAS NOT SEALED WITH | | | RAISED SEAL AS REQUIRED PER FS 471.025 | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-09-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-09-11 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-09-11 |
Time |
10:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-06-06 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-06 |
Time |
20:39 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-06 |
Time |
20:37 |
Sent To |
|
|
| Notes |
| 2007-06-06 20:39:21 | ** UNSAT ** | | | | | | 1) NOTE: PLEASE THE PERMIT APPLICATION SCOPE OF WORK | | | NEEDS TO CORRELATE WITH PLANS. | | | PLEASE SEE THE SCOPE ONLY MENTIONS CHANGING OF ANTENNAS | | | ONLY. | | | PLEASE SEE THE VALUE FOR THE SCOPE OF WORK IS REQUIRED | | | TO INCLUDE ALL LABOR, MATERIALS, EQUIPMENT, | | | ARCHITECTURAL/DESIGN FEES ETC EVEN IF ANY EQUIPMENT, | | | MATERIALSOR OTHER SERVICES ARE OWNER SUPPLIED. THE | | | VALUE AS APPLIED SEEMS LOW FOR SCOPE AND EQUIPMENT | | | SHOWN. | | | FBC 108.3 | | | | | | 2) NOTE: PLEASE SEE THE COVER SHEET ON EACH SET IS NOT | | | SEALED AND DATED AS REQUIRED PER FS471.025 | | | | | | 3) NOTE: PLEASE SEE THE LICENSE NUMBER AS LISTED ON | | | TITLE BLOCK FOR CERTIFICATE OF AUTHORIZATION NUMBER IS | | | BEING INDICATED AS *CLOSED* ON STATE WEBSITE. PLEASE | | | SEE THE ATTACHED COPY OF THE PRINT OUT FROM DBPR AS OF | | | THIS REVIEW. | | | PLEASE SEE THE ADDRESS AS LISTED WITH THE STATE DOES | | | NOT COORDINATE WITH PLANS AND TITLE BLOCKS AS | | | SUBMITTED. | | | FS471.023, FAC61G15-23.002 | | | | | | 4) NOTE: PLEASE SEE FS 713.13 AS A RECORDED NOC WILL BE | | | REQUIRED.(BUILDING REVIEW) | | | | | | 5) NOTE: PLEASE BE SURE PLANS INDICATE THE LATEST CODE | | | ADOPTED BY THE STATE FOR ELECTRICAL. NEW CODE ADOPTED | | | AS OF DECEMBER 8TH, 2006 IS THE 2005 NFPA-70 (NEC) | | | PLEASE BE SURE PLANS STATE THIS. | | | | | | 6) NOTE: PLEASE BE SURE EACH SHEET ON TITLE BLOCKS | | | CONTAINS THE PRINTED NAME AND LICENSE NUMBER OF THE | | | DESIGNER AS SIGNED AND SEALED ON PLANS OF RECORD. | | | PLEASE SEE T1. | | | FAC 61G15-23.002 | | | | | | | | | PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2007-12-24 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-12-24 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-12-24 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2007-12-24 11:19:38 | *****APPROVED W/ REMINDER | | | | | | | | | PENETRATIONS INTO, AND OPENINGS THROUGH, AN EXIT | | | ENCLOSURE ASSEMBLY SHALL BE LIMITED AS PER THE 2003 | | | EDITION OFNFPA 101 (LIFE SAFETY CODE).PLAN SHEETS | | | C4.1 AND C4.2 WERE STAMPED, INITIALED, AND DATED. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2008-07-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-21 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-21 |
Time |
16:55 |
Sent To |
B |
|
| Notes |
| 2008-07-21 16:55:54 | TO "JWITMER" DESK/RESTAMP |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-02-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-20 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-20 |
Time |
12:46 |
Sent To |
|
|
| Notes |
| 2008-02-20 12:49:17 | TO "COMM" BD#25 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-02-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-20 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-20 |
Time |
12:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-11-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-16 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-16 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2007-11-30 13:36:19 | TO "COMM" BD#36 | | 2007-11-16 15:34:42 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-08-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-21 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-21 |
Time |
14:35 |
Sent To |
|
|
| Notes |
| 2007-09-11 08:38:03 | TO "COMM" BD#15 | | 2007-08-21 14:37:40 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-08-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-10 |
Time |
10:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-10 |
Time |
10:36 |
Sent To |
PC |
|
| Notes |
| 2007-08-10 10:37:21 | PLANS REMOVED FROM PROCESSING. SEE NOTES IN FRONT | | | SCREEN. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-07-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-28 |
Time |
12:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-28 |
Time |
12:21 |
Sent To |
|
|
| Notes |
| 2007-07-28 12:21:46 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-06-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-06-13 |
Time |
13:51 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2007-05-17 |
Time |
13:46 |
Sent To |
|
|
| Notes |
| 2007-06-05 15:51:17 | TO "COMM" BD#18 | | 2007-05-17 13:52:25 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2008-02-26 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2008-02-26 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2008-02-26 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2008-02-26 14:59:57 | ZONING REVIEW: PASSED | | | | | | * EQUIPMENT SHALL BE PAINTED TO MATCH BUILDING | | | | | | MATT FLIS - 822-1445 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-12-02 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2007-12-02 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2007-12-02 |
Time |
14:21 |
Sent To |
|
|
| Notes |
| 2007-12-02 14:22:09 | ZONING REVIEW: PASSED | | | | | | ** SEE PREVIOUS NOTE - NEW EQUIPMENT SHALL BE PAINTED | | | TO MATCH COLOR OF EXISTING BUILDING ** | | | | | | MATT FLIS - 822-1445 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-09-13 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2007-09-13 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2007-09-13 |
Time |
15:59 |
Sent To |
|
|
| Notes |
| 2007-09-13 16:00:38 | ZONING REVIEW: PASSED | | | | | | * NEW ANTENNAS AND MOUNTING EQUIPMENT SHALL BE PAINTED | | | TO MATCH BUILDING | | | | | | MATT FLIS - 822-1445 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-06-11 |
|
|
Cont ID |
|
| Sent By |
mflis |
Date |
2007-06-11 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
mflis |
Date |
2007-06-11 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2007-06-11 13:59:39 | ZONING REVIEW: FAILED | | | | | | 1) PLEASE PROVIDE ENLARGED BUILDING ELEVATIONS AT ROOF | | | LEVEL CLEARLY SHOWING PROPOSED, EXISTING, AND REPLACED | | | EQUIPMENT | | | 2) ENLARGED ELEVATIONS SHOULD INDICATE DIMENSIONS ABOVE | | | ROOF DECK ELEVATION, AND HEIGHTS OF PROPOSED EQUIPMENT | | | 3) INDICATE COLORS/FINISHED FOR EQUIPMENT OR PROVIDE | | | NOTATION ON ELEVATIONS TO INDICATE MATERIALS | | | | | | MATT FLIS - 822-1445 |
|
|