| Plan Review Stops For Permit 07050534 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-10-16 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-10-16 |
Time |
17:43 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-10-16 |
Time |
17:43 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-08-30 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-08-30 |
Time |
18:04 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-08-30 |
Time |
18:04 |
Sent To |
|
|
| Notes |
| 2007-08-30 18:16:43 | | | | | | | DENIED | | | | | | THE FOLLOWING REVIEW COMMENTS WERE NOT ADDRESSED: | | | | | | | | | 1)ENGINEERS SHALL LEGIBLY INDICATE THEIR NAME, | | | ADDRESS, AND LICENSE NUMBER ON EACH SHEET THAT BEARS | | | THEIR SEAL PER 61G15-23.002(2) FAC | | | | | | 2)AN ENGINEER PRACTICING THROUGH A DULYAUTHORIZED | | | ENGINEERING BUSINESS SHALL INDICATE THEIR NAME AND | | | LICENSE #, AS WELL AS THE NAME,ADDRESS AND CERTIFICATE | | | OF AUTHORIZATION #ON EACH SHEET PER | | | 61G15-23.002 (2) FAC | | | | | | ********PLEASE NOTE THAT EVERY PAGE MUST CONTAIN BOTH | | | THE ENGINEERS LICENCE NUMBER AND THE BUSINESS OR | | | CERTIFICATE OF AUTHORIZATION NUMBER, IN ADDITION EACH | | | PAGE SHALL BE SIGNED AND SEALED BY SAID | | | ENGINEER********* | | | | | | 6)PROVIDE SEPARATION/BARRIER BETWEEN EXISTING WOOD | | | BEAM AND NEW CONCRETE BEAM. | | | | | | ********WHAT IS THE METHOD OF SEPARATION THAT WILL BE | | | USED, BUILDING PAPER, METAL, ETC PLEASE BE | | | SPECIFIC******* | | | | | | NEW COMMENTS | | | | | | 1)ENERGY CALC'S REQUIRE CLARIFICATION PAGE 2 SHOWS | | | CEILING INSULATION VALUE OF R19 AND PAGE 6 SHOWS R30 | | | ALSO NO WALL TYPE IS STATED IN THE ENERGY CALC'S FOR | | | WOOD WITH R19 (SEE PAGE 2 GABLE END) | | | | | | NOTE: THE GLASS BLOCK SYSTEM THAT WAS CHOSEN IS ONLY | | | SMALL MISSILE IMPACT RATED, ALL OPENINGS WITHIN 30 FEET | | | OF GRADE ARE REQUIRED TO BE LARGE MISSILE RATED | | | THEREFORE SHUTTERS WILL BE REQUIRED FOR THIS OPENING | | | | | | A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT IS REQUIRED PRIOR TO | | | A PERMIT BEING ISSUED | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-06-26 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-06-26 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-06-26 |
Time |
16:20 |
Sent To |
PC |
|
| Notes |
| 2007-06-26 16:38:45 | | | | | | | DENIED | | | | | | 1)ENGINEERS SHALL LEGIBLY INDICATE THEIR NAME, | | | ADDRESS, AND LICENSE NUMBER ON EACH SHEET THAT BEARS | | | THEIR SEAL PER 61G15-23.002(2) FAC | | | | | | 2)AN ENGINEER PRACTICING THROUGH A DULYAUTHORIZED | | | ENGINEERING BUSINESS SHALL INDICATE THEIR NAME AND | | | LICENSE #, AS WELL AS THE NAME,ADDRESS AND CERTIFICATE | | | OF AUTHORIZATION #ON EACH SHEET PER | | | 61G15-23.002 (2) FAC | | | | | | NOTE: TITLE BLOCK IS MISSING PE LICENSE NUMBER AND | | | SHOWSCERTIFICATE OF AUTHORIZATION NUMBER AS THE | | | LICENSE NUMBER PLEASE MAKE CORRECTIONS TO TITLE | | | BLOCKS. | | | | | | 3)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS | | | LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS | | | AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST | | | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC | | | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES | | | PER 108.3 FBC* FEES ARE DUE IN THE AMOUNT OF $164.63 | | | FOR THE INCREASED VALUE. | | | | | | 4)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2 | | | FBC. BE SURE THAT THEY ARE SIGNED AND | | | DATED BY PREPARER AND OWNER/AGENT PRIOR | | | TO SUBMITTAL | | | | | | 5)IN AN EXISTING BUILDING WHERE ALTERATIONS ARE BEING | | | MADE A DESIGN PROFESSIONAL MUST ELECT THE LEVEL OF | | | ALTERATION PER 301.5 OF EXISTING BUILDING CODE AND | | | STATE ALONG WITH THE TYPE OF CONSTRUCTION ON THE | | | DRAWINGS | | | | | | 6)PROVIDE SEPARATION/BARRIER BETWEEN EXISTING WOOD | | | BEAM AND NEW CONCRETE BEAM. | | | | | | 7)PROVIDE A KEY PLAN THAT NUMBERS OPENINGS FOR | | | SHUTTERS AND A COMPLETED INSTALLATION SCHEDULE (SEE | | | EXAMPLE ATTACHED) | | | | | | 8)PROVIDE PRODUCT APPROVALS FOR GLASS BLOCK AND | | | SIMPSON CONNECTORS | | | | | | 9)IF EXISTING ROOF STRUCTURE STAYS IN PLACE ABOVE | | | FRAMED WALL (SHORING WHILE WALLS ARE REPLACED) SHOW | | | DETAIL FOR SUPPORT OF THE EXISTING WOOD BEAM AT IE. | | | COLUMN AT THAT LOCATION AND DETAIL ON THE NEW TIE BEAM | | | FROM THAT POINT ON AND THE METHOD TO TIE INTO EXISTING | | | WALL. ALSO SHOW DROP DOWN ABOVE DOOR. | | | | | | 10)EMERGENCY EGRESS PER R310 FBC: | | | MIN. NET CLEAR OPENING OF 5 SQ.FT. ON | | | GRADE FLOOR. MIN. NET CLEAR OPENING ALL | | | OTHER FLOORS OF 5.7 SQ.FT. IN BOTH CASES | | | THE MIN.NET CLEAR HEIGHT SHALL BE 24" | | | AND THE NET CLEAR WIDTH SHALL BE 20" WITH THE SILL | | | HEIGHT NO MORE THAN 44" ABOVE FLOOR LEVEL TYPICALLY THE | | | SH24 DOES NOT MEET THIS CRITERIA. | | | | | | 11)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT IS REQUIRED PRIOR TO | | | A PERMIT BEING ISSUED | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-10-01 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-10-01 |
Time |
07:28 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-10-01 |
Time |
07:06 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-08-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-08-27 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-08-27 |
Time |
15:57 |
Sent To |
P |
|
| Notes |
| 2007-08-27 16:07:11 | | | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE CYCLES: | | | | | | THE 2004 FLORIDA BUILDING CODE, 2006 REVISIONS, 2004 | | | RESIDENTIAL BUILDING CODE, 2005 NEC, NFPA-72 2002, | | | NFPA-101 2003, 2004 FBC AS AMENDED, CHAPTER 1.AND FOUND | | | NONCOMPLIANT WITH THE FOLLOWING: | | | | | | 1} THE ENGINEER WHOSE NAME APPEARS ON THE TITLE BLOCK | | | MUST SIGN, DATE AND SEAL THE DOCUMENT. 61G15-23.002 | | | FAC. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | WILLIAM R. TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-05-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-05-23 |
Time |
15:43 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-05-23 |
Time |
15:30 |
Sent To |
M |
|
| Notes |
| 2007-05-23 15:50:01 | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW PRIOR TO ROUGH | | | INSPECTION. | | | | | | THE VALUE ON THE APPLICATION MUST INCLUDE THE TOTAL | | | COST OF LABOR AND MATERIAL. VALUATION REFERENCES MAY | | | INCLUDE THE LATEST PUBLISHED DATA OF NATIONAL | | | CONSTRUCTION COST ANALYSIS SERVICES PER 108.3 FBC AS | | | AMENDED. | | | | | | A PERMIT SHALL NOT BE ISSUED UNTIL FEES AUTHORIZED | | | UNDER SECTION 553.80, FLORIDA STATUTES, HAVE BEEN PAID. | | | 108.1 FBC. | | | | | | ADJUST THE VALUE AT THE PERMIT CLERK?S DESK, AND PAY | | | THE DIFFERENCE IN FEES PRIOR TO RESUBMITTING. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-09-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-28 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-28 |
Time |
10:00 |
Sent To |
E |
|
| Notes |
| 2007-09-28 10:00:39 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-08-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-21 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-21 |
Time |
14:27 |
Sent To |
Z |
|
| Notes |
| 2007-08-21 14:27:33 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-05-18 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-18 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-18 |
Time |
11:48 |
Sent To |
E |
|
| Notes |
| 2007-05-18 11:49:00 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2007-06-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-16 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2007-05-16 11:09:07 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-10-15 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-10-15 |
Time |
09:41 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-10-15 |
Time |
09:41 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-08-29 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-29 |
Time |
15:48 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-08-29 |
Time |
15:48 |
Sent To |
B |
|
| Notes |
| 2007-08-29 16:06:53 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (WPB), FLORIDA | | | ADMINISTRATIVE CODE (FAC), AND FLORIDA STATUTES (FS). | | | | | | *** DENIED *** | | | 1) THE ENGINEER WHO'S INFORMATION IS IN THE TITLE BLOCK | | | MUST SIGN AND SEAL THE PLANS. SEE FAC 61G15-23.002 | | | SEAL, SIGNATURE AND DATE SHALL BE AFFIXED. | | | | | | 2) MECHANICAL PLAN PAGE 9 NEEDS TO SHOW THE BATHROOM | | | EXHAUST FAN AND CFM'S, IF ONE IS TO BE INSTALLED AS | | | SHOWN ON ELECTRICAL PLAN PAGE 7. SEE 2004 FBC/RES. | | | R303.3. | | | | | | 3) ENERGY CALCULATIONS SHOW A 12,000 BTU 13 SEER A/C | | | SYSTEM IS TO BE INSTALLED, MECHANICAL PLANS SHOW NO A/C | | | SYSTEM TO BE INSTALLED. PLEASE CORRECT ENERGY CAL'S. TO | | | SHOW NEW WORK FOR ADDITION OR WHOLE HOUSE NEW AND | | | EXISTING, SEE 13-101.2.2. IT MAY BE EASIER TO SUBMIT | | | FORM 600C-04 FOR THE ADDITION ONLY. | | | | | | 4) ENERGY CAL'S. LINE 10A SHOW ATTIC INSULATION TO BE | | | R-30, PLANS PAGE 2 SHOWS THE ATTIC INSULATION TO BE | | | R-19. THE TWO MUST COINCIDE, PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-05-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-05-23 |
Time |
15:50 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-05-23 |
Time |
16:22 |
Sent To |
P |
|
| Notes |
| 2007-05-23 16:38:29 | *** DENIED *** | | | 1) INFORMATION MISSING FROM TITLE BLOCK. ENGINEER'S | | | LICENSE NUMBER 37549. NUMBER 27186 IS SHOWING AS THE | | | LICENSE NUMBER BUT THAT IS THE CERTIFICATE OF | | | AUTHORIZATION NUMBER, PLEASE CORRECT. SEE FAC | | | 61G15-23.002 (2)A TITLE BLOCK ON EACH SHEET | | | CONTAINING THE PRINTED NAME, ADDRESS, AND LICENSE | | | NUMBER OF THE ENGINEER OR IF APPLICABLE, THE NAME AND | | | LICENSE NUMBER OF THE ENGINEER, AND THE NAME, ADDRESS | | | AND CERTIFICATE OF AUTHORIZATION NUMBER OF THE | | | ENGINEERING BUSINESS WILL SATISFY THIS REQUIREMENT. | | | | | | 2) PLEASE SUBMIT ENERGY CALCULATIONS, SEE 2004 FBC | | | 13-101.2.2. AND PLEASE HAVE ENERGY CAL'S. SIGNED BY | | | OWNER/AGENT ALSO, SEE 2004 FBC 13-600.3.ABC.2. | | | | | | 3) PLEASE PROVIDE FOR RETURN AIR FOR THE BEDROOM, SEE | | | 2004 FBC/R M1602.4. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-10-15 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-10-15 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-10-15 |
Time |
08:15 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-08-29 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-08-29 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-08-29 |
Time |
13:55 |
Sent To |
M |
|
| Notes |
| 2007-08-29 14:20:42 | DENIED 2ND TIME | | | REFERENCE: | | | ** FBC-2004 PLUMBING. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW ARE STILL | | | IN NEED OF ADDRESSING ALONG WITH SOME NEW COMMENTS, | | | SOME BASED ON PLANS NOW SUBMITTED, NEW DOCUMENTS BEING | | | REVIEWED FOR THE FIRST TIME AND SOME NEW COMMENTS NOT | | | MADE ON PREVIOUS REVIEWS. | | | | | | ** PLEASE SEE THE NOTES BELOW ARE TAKEN DIRECTLY FROM | | | PREVIOUS REVIEW WITH A NO, OK OR A NO/OK. | | | THESE WILL BE FOR THE EXACT NUMERICAL NOTATION OF THE | | | PREVIOUS REVIEW NOTES. | | | | | | A NO IS IF THE COMMENT WAS NOT FULLY ADDRESSED AND/OR | | | FURTHER EXPLANATION OR CHANGES IN PLANS OR DOCUMENTS | | | ARE STILL NEEDED. THIS REVIEWER WILL TRY TO BETTER | | | EXPLAIN NOTE ABOVE PREVIOUS REVIEW COMMENT. | | | | | | AN OK WILL BE LABELED AS SUCH ON THE SAME NUMERICAL | | | COMMENT AND WILL HAVE OLD NOTE REMOVED FROM COMMENTS. | | | | | | A NO/OK MEANS PART OF THE COMMENT MAY HAVE BEEN | | | ADDRESSED, HOWEVER NOT ALL OF THE PREVIOUS REVIEW | | | COMMENT MAY HAVE BEEN FULLY ADDRESSED. | | | | | | ** PLEASE SEE ANY NEW NOTES WILL BE ADDED TO THE END OF | | | THE PREVIOUS REVIEW COMMENTS AND NOTED AS SUCH. | | | | | | 1. **NO/OK**TITLE BLOCK INFORMATION IS STILL WRONG | | | PER THE FOLLOWING: FLORIDA ADMINISTRTIVE CODE | | | 61G15-23.002(2) EACH SHEET OF PLANS AND PRINTS WHICH | | | MUST BE SEALED UNDER PROVISIONS OF CHAPTER 471 SHALL BE | | | SEALED, SIGNED AND DATED BY THE PROFESSIONAL ENGINEER | | | IN RESPONSIBLE CHARGE. IF PRACTICING THROUGH A DULY | | | AUTHORIZED ENGINEERING BUSINESS THE CERTIFICATE OF | | | AUTHORIZATION NUMBER OF THE ENGINEERING BUSINESS IS | | | ALSO REQUIRED ON EACH SHEET. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL= [email protected] | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-06-08 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-06-08 |
Time |
08:56 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-06-08 |
Time |
08:56 |
Sent To |
B |
|
| Notes |
| 2007-06-08 09:43:05 | DENIED | | | REFERENCE: | | | ** FBC-2004 PLUMBING. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | THE FOLLOWING CORRECTION IS REQUIRED FOR PLUMBING PLAN | | | REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. NOTE: TITLE BLOCK INFORMATION IS WRONG ON ALL | | | SHEETS PER THE FOLLOWING. THE LICENSE NUMBER 27186 | | | BEING INDICATED ON ALL SHEETS IS THE CERTIFICATE OF | | | AUTHORIZATION NUMBER FOR BUCK ENGINEERING, INC. THE | | | PROFESSIONAL ENGINEER LICENSE NUMBER 37549 IS FOR | | | GORDON F. BUCK. PLEASE SEE DBPR LICENSE SEARCH SHEETS | | | ATTACHED TO THE PLUMBING COMMENTS INDICATING THIS. | | | PLEASE CORRECT THIS ON THE RESUBMITTAL PER FAC | | | 61G15-23.002(2) A TITLE BLOCK ON EACH SHEET CONTAINING | | | THE PRINTED NAME, ADDRESS, AND LICENSE NUMBER OF THE | | | ENGINEER OR IF APPLICABLE, THE NAME AND LICENSE NUMBER | | | OF THE ENGINEER, AND THE NAME, ADDRESS AND CERTIFICATE | | | OF AUTHORIZATION NUMBER OF THE ENGINEERING BUSINESS | | | WILL SATISFY THIS REQUIREMENT. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-08-21 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-08-21 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-08-21 |
Time |
17:52 |
Sent To |
E |
|
| Notes |
| 2007-08-21 17:52:43 | *NO NONCONFORMITY SHALL BE INCREASED.NO NEW | | | NONCONFORMITY SHALL BE CREATED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-05-17 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-05-17 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-05-17 |
Time |
17:00 |
Sent To |
I |
|
| Notes |
| 2007-05-17 17:05:18 | ***FAILED*** | | | | | | | | | 1)SITE PLAN SHOWS DEMOLITION OF EXISTING EXTERIOR | | | WALLS IN SIDE SETBACK.ONCE THESE WALL HAVE BEEN TAKEN | | | DOWN THEY MUST BE REPLACED CONFORMING TO CODE.WHICH | | | MEANS THERE WOULD BE A REQUIRED SIDE SETBACK ON THAT | | | SIDE OF 7.4' INSTEAD OF THE 4.9' THAT PRESENTLY EXISTS. | | | PLANS MUST BE AMENDED TO THIS SETBACK IF YOU WISH TO | | | REMOVE THESE WALLS AND RECONSTRUCT, OTHERWISE THEY | | | WOULD NEED TO BE LEFT INTACT. | | | | | | | | | CHRIS HOOPS | | | ZONING TECHNICIAN | | | 561-805-6720 |
|
|