Plan Review Details - Permit 07050276
Plan Review Stops For Permit 07050276
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2008-08-09 Cont ID  
Sent By amorse Date 2008-08-09 Time 09:03 Rev Time 0.00
Received By amorse Date 2008-08-09 Time 09:03 Sent To PC
Notes
2008-08-09 09:04:39 
  
 PASSED
  
 REVISION FOR ADDITION OF SHOWER TO PERMIT, STRUCTURAL
 OK.CUSTOMER TO PAY FEE OF $59.49 FOR INCREASED VALUE
 AND STATE RADON FEES DUE TO INCREASED SQUARE FOOTAGE
 AND ADDITION OF SHOWER.
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2008-02-13 Cont ID  
Sent By amorse Date 2008-02-13 Time 17:47 Rev Time 0.00
Received By amorse Date 2008-02-13 Time 17:47 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-06-24 Cont ID  
Sent By amorse Date 2007-06-24 Time 11:23 Rev Time 0.00
Received By amorse Date 2007-06-24 Time 11:23 Sent To PC
Notes
2007-06-24 11:36:24 
  
 DENIED
  
 1)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL
 PERMIT SETS OF PLANS MUST BE STAMPED BY THAT OFFICE,
 AND A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT
 APPLICATION. PLEASE CALL (561) 233-5025 FOR MORE
 INFORMATION.
  
 NOTE: THE PLANS SHALL BE STAMPED BY COUNTY EVEN IF NO
 FEE IS DETERMINED
  
 2)DRAWINGS AND SURVEY SHALL SHOW THE LOCATION OF ALL
 WORK, INCLUDING THE PROPOSED BUILDING(S) OR
 STRUCTURE(S) COMPLETE WITH ALL SIDEYARD, FRONT AND REAR
 SETBACKS SHOWN.
  
 3)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*
  
 4)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON
 SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER
 ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE
 ADDED TO THE PERMIT APPLICATION FEES
  
 NOTE: FEES ARE DUE IN THE AMOUNT OF $ 113.48 FOR
 INCREASED VALUE AND STATE RADON FEE.
  
 5)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF
 EACH PRODUCT APPROVAL THAT IS RELEVANT PER 9B-72. THESE
 SHOULD INCLUDE THE FLORIDA STATE APPROVAL COVER PAGES,
 AND THE PRODUCT NOA THAT LISTS THE SYSTEM COMPONENTS/
 FASTENER LIST PAGES, THE PAGES WITH THE CHOSEN
 ASSEMBLY/ SYSTEM TO BE USED AND THE GENERAL LIMITATIONS
 PAGE. ALL CAN BE FOUND ON WWW.FLORIDABUILDING.ORG
  
 NOTE: PROVIDE THE PRODUCT APPROVAL FOR THE MODIFIED
 ROOFING MEMBRANE, BE SURE TO MEET ENHANCED FASTENING
 WHERE REQUIRED. ALSO PROVIDE REVISED FLORIDA AND
 ACCOMPANYING MIAMI-DADE NOA FOR THE PGT FRENCH DOOR
 (FL#253-R5 & 06-0807.07)
  
 6)THE REAR DOOR AND LANDING SHALL COMPLY WITH R
 311.4.3 FBC RES.
  
 7)SHOW COMPLIANCE WITH R 313.1.1 FBC RES FOR SMOKE
 ALARMS
  
 8)SUBMIT ENERGY CALC'S PER 13-101.2.2 FBC. BE SURE
 THAT THEY ARE SIGNED AND DATED BY PREPARER AND
 OWNER/AGENT PRIOR TO SUBMITTAL
  
 9)PROVIDE ROOF SHEATHING ATTACHMENT THAT COMPLIES
 WITH R803.2.3.1 FBC RES
  
 10)GENERAL NOTES ON A/4 SHALL MEET 2004 FBC W/ 2006
 AMENDMENTS
  
 11)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO A PERMIT BEING
 ISSUED
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2008-07-28 Cont ID  
Sent By dpalmer Date 2008-07-28 Time 08:56 Rev Time 0.00
Received By dpalmer Date 2008-07-28 Time 08:56 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-02-16 Cont ID  
Sent By dpalmer Date 2008-02-16 Time 19:48 Rev Time 0.00
Received By dpalmer Date 2008-02-16 Time 19:48 Sent To B
Notes
2008-02-16 19:48:442008-02-16 19:48:44
  
 ELEC OK, STAMPED AND ROUTED TO BUILDING AM'S DESK FOR
 PROCESSING AND ISSUANCE FOR PERMIT.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2008-02-13 Cont ID  
Sent By dpalmer Date 2008-02-13 Time 11:20 Rev Time 0.00
Received By dpalmer Date 2008-02-13 Time 11:20 Sent To M
Notes
2008-02-13 11:20:51*** DENIED 2ND REVIEW ***
  
 ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW ARE IN
 NEED OF ADDRESSING.
  
 1) NOTE: PLEASE SEE NOTE # 5 WHICH REQUESTED FOR ITEMS
 ON PANEL *A* TO COORDINATE WITH THE LOAD CALCULATIONS.
 PLEASE SEE THE FOLLOWING FOR EXAMPLES WHICH DO NOT
 MATCH.
 GARAGE DOOR ON LOAD CALCULATIONS NOT ON EITHER PANEL
 SCHEDULE.
 RANGE HOOD ON LOAD CALCULATIONS NOT ON EITHER PANEL
 SCHEDULE.
 PLEASE VERIFY HOW THE BATH GFI CIRCUIT #16 IS BEING
 SHOWN AS NEW ON PLANS IS EXISTING ON PANEL SCHEDULE.
 PLEASE COORDINATE. NEC 220
 FBC 106.1.2
  
 2) NOTE: PLEASE SEE PREVIOUS REVIEW NOTE #7 WHICH
 MENTIONED SOME COORDINATION ISSUES FROM INFORMATION
 SHOWN ON RISER COMPARED TO INFORMATION SHOWN ON PANELS.
 PLEASE SEE THE FOLLOWING FOR EXAMPLES:
 PLEASE SEE RISER WHICH STATES THE PANEL *B* AS A NEW
 60AMP MCB PANEL.
 PLEASE SEE THE SAME PANEL *B* ON PANEL STATES THIS
 PANEL IS EXISTING AND IS A 50AMP MCB.
 WHICH ONE?
 PLEASE SEE THE PANEL SCHEDULE FOR *B* PANEL STATES THE
 LOAD HIGHER THAN THE LOAD ON PANEL *A* WHICH SHOWS THE
 SUB FEED FOR THE PANEL *B*.
 ONCE AGAIN PLEASE COORDINATE.
  
 ** IF THERE ARE ANY QUESTIONS PLEASE CALL TO GO OVER
 PLANS.
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR
 CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL
 OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS
 INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT
 LEAVE ANY OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY
 DELAYS.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-05-14 Cont ID  
Sent By dpalmer Date 2007-05-14 Time 12:35 Rev Time 0.00
Received By dpalmer Date 2007-05-14 Time 10:36 Sent To M
Notes
2007-05-14 12:36:40** UNSAT **
  
 ** PLEASE SEE REFERENCES TO CHAPTER 1 OF THE FLORIDA
 BUILDING CODE IS THE ADMINISTRATIVE SECTION AS ADOPTED
 BY THE CITY OF WEST PALM BEACH.
  
 1) NOTE:PLEASE SEE THAT PLANS ARE REQUIRED TO STATE
 ALL RELEVANT CODES WITH RESPECT TO SCOPE OF WORK.
 PLEASE SEE THIS PROJECT IS UNDER THE FBC 2004 W/2006
 REVISIONS.
 PLEASE ALSO INCLUDE THE 2005 NFPA-70 (NEC) AND THE 2002
 NFPA-72.
  
 2) NOTE: PLEASE SEE THE 2005 NEC 210.8A7 AS ALL
 RECEPTACLES 15/20AMP 125V WITHIN 6FT OF A LAUNDRY TUB
 MUST BE GFI/GFI PROTECTED. THIS REQUIRES EVEN THE
 DEDICATED SINGLE WASHER RECEPTACLE.
  
 3) NOTE: PLEASE SEE THE MISSING DEDICATED BATH CIRCUIT
 PER 210.11C3, 210.52. PLEASE SEE THE PLANS LIST A
 CIRCUIT WHICH PANEL SCHEDULE SHOWS GEN LTS AND
 RECEPTS.
 (MUST BE #12 AND 20AMP.)
  
 4) NOTE: PLEASE SEE FBC R313 AS THE EXISTING DWELLING
 IS REQUIRED TO BE BROUGHT UP TO CODE OR THE EXISTING IS
 TO SHOW MEETING THE CURRENT CODE FOR SMOKE
 DETECTION/SOUNDING DEVICES. PLEASE SHOW A LAYOUT OF THE
 EXISTING DWELLING WHICH WILL REQUIRE SMOKE DEVICES
 INSIDE AND OUTSIDE ALL BEDROOMS AND ON EACH LEVEL IF A
 MULTI-LEVEL BUILDING.
 PLEASE SHOW THE SMOKE DEVICES AS SA OR SD DEPENDING ON
 THE TYPE OF DEVICE.
 NFPA-72 11.5.1.1, 11.8.3
  
 5) NOTE: PLEASE SEE THE EXISTING PANEL *A* WHICH DOES
 NOT FULLY CORRELATE WITH THE LOAD CALCULATIONS. PLEASE
 SEE THERE ARE SOME ITEMS ON LOAD CALCULATIONS WHICH ARE
 NOT LISTED ON PANEL SCHEDULE?
 PLEASE ADJUST.
 NEC 408.4, 220
 FBC 106.3.5.4, 106.1.2
  
 6) NOTE: PLEASE VERIFY THE EXISTING AHU AS THE HEAT
 STRIP IS SHOWN AS 5.5KW, YET THE OVER CURRENT
 PROTECTION IS SHOWN AT 60AMPS WHICH IS TOO HIGH. PLEASE
 ALSO COORDINATE THE LOAD ON THE PANEL AND THE LOAD
 CALCULATIONS. PLEASE SEE THE PANEL SCHEDULE SHOWS BOTH
 5.5 KW AND 1.0 KVA?
 PLEASE ADJUST.
 220, 408.4, 240.4
 FBC 106.1.2, 106.3.5.4
  
 7) NOTE: PLEASE COORDINATE THE FEEDERS FROM THE
 EXISTING PANEL *A* TO EXISTING PANEL *B*. PANEL A SHOWS
 #8 AND ON A 2-POLE 50AMP BREAKER AND A TOTAL LOAD OF
 1.1KVA?
 PLEASE SEE THE LOAD ON PANEL *B* EXCEED THIS LOAD OF
 1.1KVA.
 PLEASE SEE THE RISER SHOWS #6 FOR FEEDERS AND ALSO
 SHOWS 60AMP.
 PLEASE SEE THE PANEL *B* ON RISER AND PANEL SCHEDULE
 SHOW THIS PANEL AS (MLO) MAIN LUG ONLY WHEN IT SHOULD
 INDICATE (MCB) MAIN CIRCUIT BREAKER. 220.31
  
 8) NOTE: PLEASE CLARIFY THE LOAD ON JACUZZI AS THIS IS
 SHOWN ON A 2-POLE 40AMP BREAKER YET THE LOAD IS ONLY AT
 1.1 KVA? PLEASE ADJUST THE CONDUCTOR AND OVER CURRENT
 PROTECTION SIZE OR ADJUST LOAD IF INDEED THE LOAD IS
 HIGHER.
 PLEASE SEE THAT THE CODE DOES LIMIT THE OVER CURRENT
 PROTECTION EITHER BY THE MANUFACTURE, LISTINGS FOR
 MOTOR LOADS AND/OR 150%.
 422.11, 110.3, 240.4, 310.16, 220 ETC.
 FBC 106.1.2
  
 9) NOTE: PLEASE SEE MISSING GROUNDING ELECTRODE
 CONNECTION TO NEW FOOTER STEEL PER 250.50. PLEASE ALSO
 CLARIFY EXISTING OR NEW CONNECTION TO COLD WATER AND
 GAS LINE BOND.(LOAD SIDE OF METER).
 250.104
  
 10) NOTE: PLEASE SEE PANELS ARE BOTH LISTED AT
 42CIRCUITS, HOWEVER PANEL *A* IS BEING SHOWN AS 30POLES
 AND PANEL *B* IS BEING SHOWN AS 18.
 PLEASE COORDINATE.
 FBC 106.3.5.4, 106.1.2
  
 11) NOTE: PLEASE SEE THE VALUE AS STATED ON PERMIT
 APPLICATION IS LOW AND WILL NEED TO MEET THE MINIMUM
 VALUES AS SET-FORTH IN THE FBC AND ICC TABLES.
 THIS MAY ALSO BE PRESENT IN BUILDING REVIEW COMMENTS.
 FBC 108.3
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2008-02-13 Cont ID  
Sent By mperson Date 2008-02-13 Time 13:41 Rev Time 0.00
Received By mperson Date 2008-02-13 Time 13:41 Sent To B
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2007-05-21 Cont ID  
Sent By mperson Date 2007-05-21 Time 16:09 Rev Time 0.33
Received By mperson Date 2007-05-21 Time 16:09 Sent To B
Notes
2007-05-21 16:17:14DENIED
 REFERENCE:
 ** FBC-2004 FUEL GAS.
 ** THE CITY OF WEST PALM BEACH GAS PERMIT APPLICATION
 REQUIREMENTS.
  
 THE FOLLOWING CORRECTION IS REQUIRED FOR GAS PLAN
 REVIEW TO MEET CODE COMPLIANCE:
  
 1. SHEET P-1 GAS DIAGRAM: PLEASE CORRECT TOTAL 24.0
 CFH @ .5" PSI TO READ TOTAL 240 CFH @ 0.5 PSI ON THE
 RESUBMITTAL.
  
 ********IMPORTANT INFORMATION********
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY.
 NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2008-07-21 Cont ID  
Sent By adarroug Date 2008-07-21 Time 13:22 Rev Time 0.00
Received By adarroug Date 2008-07-21 Time 13:22 Sent To E
Notes
2008-07-21 13:22:26TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2008-07-16 Cont ID  
Sent By adarroug Date 2008-07-16 Time 12:26 Rev Time 0.00
Received By adarroug Date 2008-07-16 Time 12:26 Sent To Z
Notes
2008-07-16 12:27:37TO "Z" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2008-02-06 Cont ID  
Sent By adarroug Date 2008-02-06 Time 09:12 Rev Time 0.00
Received By adarroug Date 2008-02-06 Time 09:12 Sent To Z
Notes
2008-02-06 09:13:14TO "Z "BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-06-24 Time   Rev Time 0.00
Received By adarroug Date 2007-05-08 Time 13:47 Sent To  
Notes
2007-05-08 13:47:13TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2008-02-13 Cont ID  
Sent By tgordon Date 2008-02-13 Time 11:53 Rev Time 0.30
Received By tgordon Date 2008-02-13 Time 11:53 Sent To P
Notes
2008-02-13 11:55:31ONE BATH EXHAUST FAN AND DRYER VENT.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-05-15 Cont ID  
Sent By tgordon Date 2007-05-15 Time 14:50 Rev Time 0.20
Received By tgordon Date 2007-05-15 Time 14:49 Sent To P
Notes
2007-05-15 14:51:45*** DENIED ***
 1) SEE ELECTRICAL REVIEW NOTE #1, PLEASE CORRECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 3 Status F Date 2008-07-28 Cont ID  
Sent By mperson Date 2008-07-28 Time 14:44 Rev Time 0.00
Received By mperson Date 2008-07-28 Time 14:44 Sent To B
Notes
2008-07-28 15:09:08PLUMBING PLAN REVIEW:
 REVISION DENIED:
  
 PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH
 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO
 CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE
 (F.A.C.), AND FLORIDA STATUTES (F.S.).
  
 1. SHEET P-1 WASTE AND VENT PLUMBING RISER: PLEASE
 CORRECT THE FOLLOWING PER FBC-2004 PLUMBING SECTIONS.
  
  
 A} CLEARLY INDICATE THE REQUIRED WATERSEAL TRAP FOR
 THE NEW SHOWER. PER SECTION 1002.1 FIXTURE TRAPS.
  
 B} THE WASTE FITTING FOR THE NEW SHOWER IS BEING
 INDICATED AS BEING INSTALLED AGAINST THE DIRECTION OF
 FLOW. PER SECTION 706.3 INSTALLATION OF FITTINGS.
  
 C} THE BRANCH WASTE FITTINGS FOR THE SHOWER BATH,
 WASHING MACHINE, AND LAUNDRY SINK ARE BEING INDICATED
 AS BEING INSTALLED AGAINST THE DIRECTION OF FLOW PER
 THE REVISED RISER DIAGRAM EXISTING SANITARY SEWER
 LOCATION. PER SECTION 706.3 INSTALLATION OF FITTINGS.
  
  
 D} THE BATHROOM GROUP (WATER CLOSET, LAVATORY, AND NEW
 SHOWER) REQUIRES A VENT. PER SECTION 909.1 WET VENT
 PERMITTED.
  
 2. SHEET P-1 PLUMBING PLAN: PLEASE CORRELATE THE
 PLUMBING PLAN TO REFLECT THE REVISED WASTE AND VENT
 PLUMBING RISER. PER SECTION 701.1 AND SECTION 901.1
 SCOPE.
  
 ********IMPORTANT INFORMATION********
 WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE
 OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW
 PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 END OF COMMENTS:
  
 REVIEW BY: MIKE PERSON
 PLUMBING PLANS EXAMINER
 PHONE= (561) 805-6730
 FAX= (561) 805-6731
 E-MAIL= [email protected]

Review Stop P PLUMBING
Rev No 2 Status P Date 2008-02-13 Cont ID  
Sent By mperson Date 2008-02-13 Time 13:41 Rev Time 0.00
Received By mperson Date 2008-02-13 Time 13:41 Sent To G
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-05-21 Cont ID  
Sent By mperson Date 2007-05-21 Time 15:48 Rev Time 0.33
Received By mperson Date 2007-05-21 Time 15:48 Sent To G
Notes
2007-05-21 16:07:23DENIED
 REFERENCE:
 ** FBC-2004 PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. PLEASE REFERENCE ELECTRICAL COMMENT #1 AND CORRECT
 ON THE RESUBMITTAL.
  
 2. VALUE FOR THE ADDITION SEEMS LOW PER THE
 FOLLOWING.
 PER FBC-2004, CHAPTER 1, SECTION
 108.3, BUILDING PERMIT VALUATION: IF IN
 THE OPINION OF THE BUILDING OFFICIAL,
 THE CLAIMED VALUATION OF THE BUILDING,
 ALTERATION, STRUCTURE, ELECTRICAL, GAS
 MECHANICAL OR PLUMBING SYSTEMS APPEARS
 TO BE UNDERESTIMATED ON THE APPLICATION,
 THE PERMIT SHALL BE DENIED. FOR
 PERMITTING PURPOSES, VALUATION OF
 BUILDINGS AND SYSTEMS SHALL BE TOTAL
 REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR
 FINISH, NORMAL SITE WORK (EXCAVATION AND
 BACKFILL FOR BUILDINGS), ARCHITECTURAL
 AND DESIGN FEES, MARKETING COSTS,
 OVERHEAD AND PROFIT; EXCLUDING ONLY LAND
 VALUE. VALUATION REFERENCES MAY INCLUDE
 THE LATEST PUBLISHED DATA OF NATIONAL
 CONSTRUCTION COST ANALYSIS SERVICES (MARSHALL-SWIFT,
 MEANS ECT.) WITH
 REGIONAL ADJUSTMENTS FOR LOCATION AS
 PUBLISHED BY INTERNATIONAL CODE
 CONGRESS. PLEASE PROVIDE PROOF OF TOTAL COST OF THE
 PROPOSED ADDITION ON THE RESUBMITTAL.
  
 3. SHEET P-1 PLUMBING PLAN: PLEASE CLARIFYWHAT 3/0
 U.B. W/ V.B. IS ON THE RESUBMITTAL. PLEASE REFERENCE
 THE RED CIRCLED AREA AND PLUMBING COMMENT NUMBER
 INDICATING THIS AREA.
  
 4. SHEET P-1 PLUMBING PLAN: PLEASE CORRECT THE WASHING
 MACHINE BOX TO READ GUY GRAY ON THE RESUBMITTAL.
  
 ********IMPORTANT INFORMATION********
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY.
 NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop Z ZONING
Rev No 3 Status P Date 2008-07-18 Cont ID  
Sent By mcruz Date 2008-07-18 Time 16:31 Rev Time 0.00
Received By mcruz Date 2008-07-18 Time 16:31 Sent To  
Notes
2008-07-18 16:32:03***ZONING APPROVED RESUB #2***

Review Stop Z ZONING
Rev No 2 Status P Date 2008-02-12 Cont ID  
Sent By choops Date 2008-02-12 Time 11:32 Rev Time 0.00
Received By choops Date 2008-02-12 Time 11:32 Sent To E
Notes
2008-02-12 11:38:09***APPROVED - RESUB #1***
  
  
  
  
 SENT TO "E" - DP

Review Stop Z ZONING
Rev No 1 Status F Date 2007-05-09 Cont ID  
Sent By choops Date 2007-05-09 Time 11:31 Rev Time 0.00
Received By choops Date 2007-05-09 Time 11:31 Sent To E
Notes
2007-05-09 11:33:12***FAILED***
  
  
 1)PLEASE SHOW SCOPE OF WORK ON BOTH SURVEYS WITH
 DIMENSIONS OF PROPOSED ADDITION, AS WELL AS DIMENSIONS
 FROM ADDITION TO PROPERTY LINES.
  
  
 CHRIS HOOPS
 ZONING TECHNICIAN
 561-805-6720