Plan Review Details - Permit 07050238
Plan Review Stops For Permit 07050238
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-06-22 Cont ID  
Sent By shill Date 2007-06-22 Time 09:04 Rev Time 0.00
Received By shill Date 2007-06-22 Time 09:04 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-06-13 Cont ID  
Sent By shill Date 2007-06-13 Time 10:07 Rev Time 0.00
Received By shill Date 2007-06-13 Time 10:07 Sent To  
Notes
2007-06-13 10:09:34****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 1.)PLANS STILL STATE THAT THIS IS EXPOSURE B AND USES
 A WORST CASE FOR EXPOSURE B DESIGN PRESSURE.FROM
 FIRST LIST, REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2),
 FBC R301.2.1.4.NOTE THAT THE DEFINITION FOR EXPOSURE
 C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC
 R301.2.1.4.
  
 2.)YOU SPECIFY 21" FOR C5, OPENING 1, BUT THE PRODUCT
 APPROVAL REQUIRES (AND YOU HAVE CIRCLED) 9".PLEASE
 CHECK ALL OPENINGS AND REVISE ACCORDINGLY.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-05-29 Cont ID  
Sent By shill Date 2007-05-29 Time 08:46 Rev Time 0.00
Received By shill Date 2007-05-29 Time 08:46 Sent To  
Notes
2007-05-29 08:47:07****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
 ____1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH
 THE CLERK OF COURTS BEFORE A PERMIT CAN BE ISSUED,
 FS713.13.
  
 ____2.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN
 PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE
 DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A
 DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ENGINEER
 AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED
 ORIGINALS FAC61G15-23.002.
  
 ____3.PROVIDE A COPY OF THE CONDO ASSOCIATION
 APPROVAL.
  
 _XX_4.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT.NOTE THAT SPECIFIC ANCHOR CONNECTION
 TYPES ARE NOT SPECIFIED FOR EACH OPENING.
  
 ____5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.
  
 ____6.ON THE PRODUCT APPROVAL, MARK WHICH DETAILS
 APPLY TO THIS JOB.PLEASE USE INK RATHER THAN A
 HIGHLIGHTER.
  
 ____7.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC
 R310.
  
 ____8.PROVIDE A FLOOR PLAN SHOWING WHERE THE
 SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH
 CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 4
 ABOVE.
  
 _XX_9.REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2),
 FBC R301.2.1.4.NOTE THAT THE DEFINITION FOR EXPOSURE
 C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC
 R301.2.1.4.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-06-21 Cont ID  
Sent By adarroug Date 2007-06-21 Time 10:14 Rev Time 0.00
Received By adarroug Date 2007-06-21 Time 10:14 Sent To B
Notes
2007-06-21 10:14:22TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-06-07 Cont ID  
Sent By adarroug Date 2007-06-07 Time 10:21 Rev Time 0.00
Received By adarroug Date 2007-06-07 Time 10:21 Sent To B
Notes
2007-06-07 10:21:48TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-05-29 Cont ID  
Sent By shill Date 2007-05-29 Time 08:47 Rev Time 0.00
Received By shill Date 2007-05-08 Time 11:23 Sent To  
Notes
2007-05-08 11:23:55TO "MISC" BOX#1


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved