Plan Review Details - Permit 07050139
| Plan Review Stops For Permit 07050139 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-06-19 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-06-19 |
Time |
15:32 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-06-19 |
Time |
15:32 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-06-09 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-06-09 |
Time |
10:42 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-06-09 |
Time |
10:42 |
Sent To |
PC |
|
| Notes |
| 2007-06-09 11:34:06 | | | | | | | DENIED | | | | | | 1)THE PERMIT APPLICATION SHALL INCLUDE TWO | | | COPIES OF EACH PRODUCT APPROVAL THAT | | | IS RELEVANT PER 9B-72. | | | | | | 2)THE FLORIDA PRODUCT APPROVAL FL5854 FOR35H DOOR | | | DOES NOT COVER THIS PARTICULAR MODEL "35H (MS)"BUT IT | | | WILL MEET REQUIREMENTS IF THE TYPE OF GLAZING IS | | | CHANGED TO SAF-GLAS AND WILL BE PERMITTED A LOCAL | | | PRODUCT APPROVAL. PLEASE NOTE THAT THE CHOSEN GLAZING | | | (SENTRYGLAS PLUS) DOES NOT MEET THE REQUIRED -66.1 | | | PSF. | | | | | | 3)PROVIDE SPECIFIC TYPE OF 9/16" GLAZING FROM THE | | | PRODUCT APPROVALS AS SOME TYPES DO NOT MEET THE | | | PRESSURE REQUIREMENTS | | | | | | 4)PGT DOES INDEED HAVE FLORIDA STATEWIDE PRODUCT | | | APPROVAL FOR SH-700 WINDOW (FL # 239-R8) | | | | | | 5)FLORIDA COVER SHEET FOR PGT MULLIONS HAS HEAVY WALL | | | HI-LIGHTED BUT STANDARD WALL MIAMI-DADE PLEASE CLARIFY. | | | NOTE STANDARD WILL MEET PRESSURES IN 1X4 MULLION ONLY. | | | | | | 6)PER 106.1.3 FBC* THE BUILDING OFFICIAL MAY | | | ESTABLISH THROUGH DEPARTMENTAL POLICY, STANDARDS FOR | | | PLANS AND SPECIFICATIONS "NO WHITE OUT, PENCIL OR INK" | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-05-22 |
|
|
Cont ID |
|
| Sent By |
amorse |
Date |
2007-05-20 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
amorse |
Date |
2007-05-20 |
Time |
17:13 |
Sent To |
PC |
|
| Notes |
| 2007-05-22 18:11:05 | | | | | | | DENIED | | | | | | 1)THE CITY OF WEST PALM BEACH REQUIRES THE | | | FLORIDA STATE PRODUCT APPROVAL COVER | | | SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON | | | WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT | | | SUBMITTED APPLICATIONS WILL BE DENIED | | | YHS-50 IS COVERED BY FLORIDA STATEWIDE APPROVAL FL# | | | 5845 THE SERIES 35H (MS) IS NOT AND HAS LOCAL PRODUCT | | | APPROVAL | | | | | | 2)NO PRODUCT APPROVALS WERE SUBMITTED FOR THE PGT | | | SINGLE HUNG WINDOW UNITS. | | | | | | 3)PROVIDE A KEY PLAN THAT SHOWS ALL EXISTING DOORS | | | AND WINDOWS AND THEIR SIZES, THE SQUARE FOOTAGE OF THE | | | BUILDING AND THE TYPE OF OCCUPANCY. ALSO PROVIDE THE | | | CORRECT WIND EXPOSURE FOR BUILDING SITUATED ON THE | | | INTERCOASTAL (EXP. C) AND THE DESIGN PRESSURES FOR THE | | | OPENINGS FOR ZONE 4 & 5 | | | | | | 4)STATE ON DRAWINGS WHETHER THE STEEL REINFORCING | | | WILL BE USED IN THE FRAME TO INCREASE THE DESIGN | | | PRESSURE REQUIREMENTS. PLEASE BE AWARE THAT THE STATE | | | OF FLORIDA REQUIRES THAT THE MIAMI-DADE NOA PRESSURE | | | VALUES SHALL BE DIVIDED BY 1.33 TO COMPLY WITH THE 2004 | | | FBC (SEE PAGE 3 OF THE FLORIDA COVER SHEETS) | | | | | | 5)PROVIDE THE TYPE OF GLAZING IN THE 35H DOOR AS THE | | | DESIGN PRESSURES DIFFER WITH THE DIFFERENT TYPES. | | | | | | BLDG PLAN REVIEW | | | ADRIAN MORSE | | | 561-805-6716 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-06-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-19 |
Time |
13:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-19 |
Time |
13:43 |
Sent To |
B |
|
| Notes |
| 2007-06-19 13:44:19 | TO "AMORSE" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-06-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-13 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-13 |
Time |
14:47 |
Sent To |
B |
|
| Notes |
| 2007-06-13 14:48:18 | TO "AMORSE" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-06-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-05 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-05 |
Time |
16:14 |
Sent To |
B |
|
| Notes |
| 2007-06-05 16:15:09 | TO "AMORSE" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2007-05-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-04 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2007-05-04 11:22:38 | TO "MISC" BOX#1 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
|
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
|