Plan Review Details - Permit 07050127
Plan Review Stops For Permit 07050127
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-06-09 Cont ID  
Sent By amorse Date 2007-06-09 Time 12:30 Rev Time 0.00
Received By amorse Date 2007-06-09 Time 12:30 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-05-22 Cont ID  
Sent By amorse Date 2007-05-20 Time 15:11 Rev Time 0.00
Received By amorse Date 2007-05-20 Time 15:10 Sent To PC
Notes
2007-05-22 16:29:12 
  
 DENIED
  
 1)PROVIDE WIND DESIGN DATA ON DRAWINGS PER
 1603.1.4 FBC
  
 2)WORK ON EXISTING BUILDINGS IS COVERED UNDER THE FBC
 (EXISTING) AS SUCH A DESIGN PROFESSIONAL OR OWNERMUST
 ELECT ONE OR A COMBINATION OF LEVELS OF ALTERATION PER
 301.5 FBC (EXISTING)
  
 3)PER 106.1.3 FBC* THE BUILDING OFFICIAL MAY
 ESTABLISH THROUGH DEPARTMENTAL POLICY, STANDARDS FOR
 PLANS AND SPECIFICATIONS "NO WHITE OUT, PENCIL OR INK"
  
 4)PROVIDE DETAIL OF TIE IN FOR INFILL OF DOOR AND
 WINDOW.
  
 5)PLEASE CLARIFY, IS WORK ONLY TO THE FRONT FACADE OF
 BUILDING AND WILL THIS PERMIT COVER INSTALLATION OF NEW
 WINDOW. WINDOWS AND DOORS THAT ARE BEING REPLACED OR
 NEW REQUIRE FLORIDA STATEWIDE PRODUCT APPROVALS
 SUBMITTED.
  
 6)PROVIDE DESIGN CRITERIA SHALL INCLUDE CODE CYCLE,
 TYPE OF CONSTRUCTION, ETC.
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-06-06 Cont ID  
Sent By adarroug Date 2007-06-06 Time 16:23 Rev Time 0.00
Received By adarroug Date 2007-06-06 Time 16:23 Sent To B
Notes
2007-06-06 16:24:07TO "AMORSE" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-05-20 Time   Rev Time 0.00
Received By adarroug Date 2007-05-04 Time 13:52 Sent To  
Notes
2007-05-04 13:53:20TO "MISC" BOX#1


Account Summary | Usage Policy | Privacy Policy