Plan Review Details - Permit 07050106
| Plan Review Stops For Permit 07050106 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
N |
Date |
2007-05-14 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-05-14 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-05-14 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2007-05-14 09:06:39 | CONCRETE ROOF , NO STRUCTURAL REVIEW REQUIRED LM |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-05-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-16 |
Time |
11:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-16 |
Time |
11:53 |
Sent To |
M |
|
| Notes |
| 2007-05-16 11:53:36 | TO "M" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-05-14 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-05-14 |
Time |
09:06 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-05-03 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2007-05-03 15:16:21 | TO "M" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2007-05-17 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-05-17 |
Time |
10:55 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-05-17 |
Time |
10:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-05-04 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-05-04 |
Time |
10:59 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-05-04 |
Time |
10:59 |
Sent To |
B |
|
| Notes |
| 2007-05-04 11:01:07 | *** DENIED *** | | | 1)ENERGY CALCULATIONS NEED THE PRINTED NAME AND | | | SIGNATURE OF THE PREPARER ALSO, PER 2004 FBC | | | 13-600.3.ABC.2. | | | | | | 2) PLEASE SUBMIT PRODUCT APPROVAL FOR PER-ENGINEERED | | | CONDENSER STANDS, SEE FS 553.842(1) AND FAC | | | 9B-72.010(31)(G). | | | | | | **PRODUCT APPROVALS SUBMITTED WITH PERMIT APPLICATION | | | AFTER OCTOBER 1, 2003 ARE REQUIRED TO COMPLY WITH THE | | | FLORIDA PRODUCT APPROVAL SYSTEM. FOR INFORMATION PLEASE | | | SEE THE STATE WEBSITE AT WWW.FLORIDABUILDING.ORG. | | | PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS THE PRODUCT | | | IDENTITY NUMBER FROM THE STATE. IF THE PRODUCT DOES NOT | | | HAVE STATEWIDE APPROVAL, SUBMIT AN APPLICATION FOR | | | LOCAL PRODUCT APPROVAL OR SITE SPECIFIC FORM PER RULE | | | 9B-72. SEE ATTACHMENT. WWW.FLORIDABUILDING.ORG. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
|