| Plan Review Stops For Permit 07050092 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-09-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-09-02 |
Time |
14:21 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-09-02 |
Time |
14:21 |
Sent To |
E |
|
| Notes |
| 2007-09-02 14:22:13 | REVISION |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-08-06 |
Time |
18:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-08-06 |
Time |
18:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-06-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-06-05 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-06-05 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2007-06-05 10:51:18 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.)POOL BARRIER REQUIRED IN COMPLIANCE WITH FBC | | | R4101.17.1.1. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-09-04 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-09-04 |
Time |
12:16 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-09-04 |
Time |
12:16 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-07-23 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-07-23 |
Time |
16:56 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-07-23 |
Time |
16:30 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-06-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-06-18 |
Time |
16:44 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-06-18 |
Time |
16:40 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2007-05-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-05-09 |
Time |
09:13 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2007-05-09 |
Time |
08:59 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
N |
Date |
2007-08-02 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-08-02 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-08-02 |
Time |
09:53 |
Sent To |
B |
|
| Notes |
| 2007-08-02 09:56:16 | CONTRACTOR INFORMATION | | | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL POOL INSPECTION. | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL= [email protected] | | | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
N |
Date |
2007-07-02 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-07-02 |
Time |
10:41 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-07-02 |
Time |
10:41 |
Sent To |
|
|
| Notes |
| 2007-07-02 10:42:54 | CONTRACTOR INFORMATION | | | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL POOL INSPECTION. | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2007-05-09 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-05-09 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-05-09 |
Time |
13:21 |
Sent To |
B |
|
| Notes |
| 2007-05-09 13:23:18 | CONTRACTOR INFORMATION | | | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL POOL INSPECTION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2007-05-02 |
|
|
Cont ID |
|
| Sent By |
swurafti |
Date |
2007-05-02 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
swurafti |
Date |
2007-05-02 |
Time |
15:08 |
Sent To |
|
|
| Notes |
| 2007-05-02 15:08:29 | HISTORIC APPROVED BY JPAPA |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-12-28 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-12-28 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-12-28 |
Time |
12:02 |
Sent To |
Z |
|
| Notes |
| 2007-12-28 12:02:20 | TO ZONING BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-11-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-19 |
Time |
14:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-19 |
Time |
14:46 |
Sent To |
Z |
|
| Notes |
| 2007-11-19 14:46:53 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-08-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-28 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-28 |
Time |
14:44 |
Sent To |
Z |
|
| Notes |
| 2007-08-28 14:44:24 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-07-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-20 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-20 |
Time |
16:25 |
Sent To |
Z |
|
| Notes |
| 2007-07-20 16:25:39 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-06-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-14 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-14 |
Time |
08:22 |
Sent To |
E |
|
| Notes |
| 2007-06-14 08:23:14 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-06-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-11 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-11 |
Time |
14:40 |
Sent To |
Z |
|
| Notes |
| 2007-06-11 14:40:30 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-05-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-07 |
Time |
16:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-07 |
Time |
16:29 |
Sent To |
E |
|
| Notes |
| 2007-05-07 16:29:44 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-06-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-05 |
Time |
14:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-03 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2007-05-03 15:34:57 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-09-11 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-09-11 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-09-11 |
Time |
15:40 |
Sent To |
PC |
|
| Notes |
| 2007-09-11 15:43:41 | REVISION: 8/23/07 NEW SHEET, CHANGE POOL SIZE, NO | | | PLUMBING CHANGES. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-08-02 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-08-02 |
Time |
09:52 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-08-02 |
Time |
09:52 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-07-02 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-07-02 |
Time |
10:17 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-07-02 |
Time |
10:17 |
Sent To |
G |
|
| Notes |
| 2007-07-02 10:19:07 | DENIED 2ND TIME | | | REFERENCE: FBC-2004 SECTION 424.2 AND 4101 SWIMMING | | | POOLS. | | | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW ARE STILL | | | IN NEED OF ADDRESSING ALONG WITH SOME NEW COMMENTS, | | | SOME BASED ON PLANS NOW SUBMITTED, NEW DOCUMENTS BEING | | | REVIEWED FOR THE FIRST TIME AND SOME NEW COMMENTS NOT | | | MADE ON PREVIOUS REVIEWS. | | | | | | ** PLEASE SEE THE NOTES BELOW ARE TAKEN DIRECTLY FROM | | | PREVIOUS REVIEW WITH A NO, OK OR A NO/OK. | | | THESE WILL BE FOR THE EXACT NUMERICAL NOTATION OF THE | | | PREVIOUS REVIEW NOTES. | | | | | | A **NO** IS IF THE COMMENT WAS NOT FULLY ADDRESSED | | | AND/OR FURTHER EXPLANATION OR CHANGES IN PLANS OR | | | DOCUMENTS ARE STILL NEEDED. THIS REVIEWER WILL TRY TO | | | BETTER EXPLAIN NOTE ABOVE PREVIOUS REVIEW COMMENT. | | | | | | AN **OK** WILL BE LABELED AS SUCH ON THE SAME NUMERICAL | | | COMMENT AND WILL HAVE OLD NOTE REMOVED FROM COMMENTS. | | | | | | A **NO/OK** MEANS PART OF THE COMMENT MAY HAVE BEEN | | | ADDRESSED, HOWEVER NOT ALL OF THE PREVIOUS REVIEW | | | COMMENT MAY HAVE BEEN FULLY ADDRESSED. | | | | | | ** PLEASE SEE ANY NEW NOTES WILL BE ADDED TO THE END OF | | | THE PREVIOUS REVIEW COMMENTS AND NOTED AS SUCH. | | | | | | 1) **OK** | | | | | | 2) **NO** FBC-2004 SEC. 424.2.6.6.5, OR | | | FBCR-2004 SEC. R4101.6.6.5 WHERE | | | PROVIDED, THE VACUUM OR PRESSURE CLEANER | | | FITTING SHALL BE LOCATED AT LEAST 6" AND | | | NOT GREATER THAN 12" BELOW THE MINIMUM | | | OPERATING WATER LEVEL OR AS AN | | | ATTACHMENT TO THE SKIMMER. (PLEASE SUBMIT ADETAIL OF | | | THE SKIMMER ON THE RESUBMITTAL) | | | NOTE: A DETAIL OF THE SKIMMER WAS ASKED FOR ON THE | | | PREVIOUS PLUMBING PLAN REVIEW AND ONE WAS NOT PROVIDED | | | ON THE RESUBMITTAL. A DETAIL IS REQUIRED, PLEASE SUBMIT | | | ONE ON THE NEXT RESUBMITTAL. | | | | | | 3) **NO** FBC-2004 SEC. 424.2.14.1, OR | | | FBCR-2004 SEC. R4101.14.1 SWIMMING POOL | | | WATER HEATERS SHALL BEAR THE LABEL OF A | | | RECOGNIZED TESTING AGENCY. (MANUFACTURE | | | SHEETS REQUIRED, PLEASE SUBMIT) | | | NOTE: THE SUBMITTED MANUFACTURER SHEET DOES NOT | | | INDICATE THAT IT IS LISTED BY A NATIONALLY RECOGNIZED | | | TESTING LABORATORY (NRTL). THE SUBMITTED SHEET DOES NOT | | | CLEARLY INDICATE THE POOL HEATER MAKE. PLEASE COMPLY ON | | | THE RESUBMITTAL. | | | | | | 4) **NO** FBC-2004 SEC. 424.2.14.2, OR | | | FBCR-2004 SEC. R4101.14.2 WATER | | | RETENTION, PROVIDE A POSITIVE MEANS OF | | | RETAINING WATER IN THE HEATER WHEN PUMP | | | IS SHUT OFF.(MANUFACTURE SHEETS | | | REQUIRED, PLEASE SUBMIT) | | | NOTE: THE SUBMITTED MANUFACTURER SHEET DOES NOT CLEARLY | | | INDICATE THE MAKE OF THE POOL HEATER. PLEASE COMPLY ON | | | THE RESUBMITTAL. | | | | | | ******NEW ITEM****** | | | | | | 5) THE ORIGINAL PERMIT APPLICATION IS MISSING FROM THE | | | RESUBMITTAL, ONE IS REQUIRED TO PROCESS PERMIT. PLEASE | | | PROVIDE ONE FOR THE NEXT RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-05-09 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-05-09 |
Time |
13:04 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-05-09 |
Time |
13:04 |
Sent To |
G |
|
| Notes |
| 2007-05-09 13:21:44 | DENIED | | | REFERENCE: FBC-2004 SECTION 424.2 AND 4101 SWIMMING | | | POOLS. | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1) FBC-2004 SEC. 424.6.6 OR FBC-2004 | | | RESIDENTIAL SEC. R4101.6.6: ENTRAPMENT | | | PROTECTION FOR SUCTION INLETS. PLEASE | | | SUBMIT AN ENGINEERED TABLE FOR "VENT | | | PIPE MAXIMUM LENGTH" INDICATING PUMP | | | SIZES, AVERAGE FLOW, AND MAXIMUM LENGTH | | | OF THE 1-1/2" PVC VENT PIPE, FROM | | | WHERE IT STARTS TO WHERE IT ENDS UP, | | | COMPLYING WITH THE THREE SECOND RELEASE. | | | NOTE: THE SUBMITTED 1-1/2" ATMOSPHREIC VENT LENGTH | | | TABLE DOES NOT REFLECT THE PROPOSED 2-1/2 HP SPA PUMP. | | | PLEASE REVISE THE VENT TABLE TO REFLECT THE 2-1/2 HP | | | PUMP ON THE RESUBMITTAL. | | | | | | 2) FBC-2004 SEC. 424.2.6.6.5, OR | | | FBCR-2004 SEC. R4101.6.6.5 WHERE | | | PROVIDED, THE VACUUM OR PRESSURE CLEANER | | | FITTING SHALL BE LOCATED AT LEAST 6" AND | | | NOT GREATER THAN 12" BELOW THE MINIMUM | | | OPERATING WATER LEVEL OR AS AN | | | ATTACHMENT TO THE SKIMMER. (PLEASE SUBMIT ADETAIL OF | | | THE SKIMMER ON THE RESUBMITTAL) | | | | | | 3) FBC-2004 SEC. 424.2.14.1, OR | | | FBCR-2004 SEC. R4101.14.1 SWIMMING POOL | | | WATER HEATERS SHALL BEAR THE LABEL OF A | | | RECOGNIZED TESTING AGENCY. (MANUFACTURE | | | SHEETS REQUIRED, PLEASE SUBMIT) | | | | | | 4) FBC-2004 SEC. 424.2.14.2, OR | | | FBCR-2004 SEC. R4101.14.2 WATER | | | RETENTION, PROVIDE A POSITIVE MEANS OF | | | RETAINING WATER IN THE HEATER WHEN PUMP | | | IS SHUT OFF.(MANUFACTURE SHEETS | | | REQUIRED, PLEASE SUBMIT) | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
6 |
Status |
P |
Date |
2008-01-03 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-01-03 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-01-03 |
Time |
11:05 |
Sent To |
PC |
|
| Notes |
| 2008-01-03 11:06:48 | ***APPROVED - RESUB #1 OF REV. - CHANGED POOL | | | BARRIER/ADDED ALARMS*** | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
F |
Date |
2007-11-28 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-11-28 |
Time |
09:26 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-11-28 |
Time |
09:26 |
Sent To |
|
|
| Notes |
| 2007-11-28 09:27:28 | ***FAILED - REVISION - CHANGE POOL BARRIER*** | | | | | | | | | 1)PROVIDE TWO COPIES OF A SURVEY SHOWING THE | | | LOCATION OF THE CHANGED POOL BARRIER. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2007-08-31 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-08-31 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-08-31 |
Time |
12:11 |
Sent To |
B |
|
| Notes |
| 2007-08-31 12:12:30 | ***APPROVED*** ***REVISION - MAKE POOL 8" SMALLER ON | | | HOUSE SIDE*** | | | | | | | | | SENT TO "B" - SH |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-07-23 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-07-23 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-07-23 |
Time |
14:34 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-06-11 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-06-11 |
Time |
16:50 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-06-11 |
Time |
16:50 |
Sent To |
I |
|
| Notes |
| 2007-06-11 16:56:00 | ***FAILED*** | | | | | | | | | 1)PLEASE PROVIDE REQUIRED EASEMENT CONSENT FORM FROM | | | THE CITY OF WEST PALM BEACH DEPARTMENT OF PUBLIC | | | UTILITIES (SEE ATTACHED FORM) | | | | | | 2)PLEASE INDICATE SETBACK DIMENSIONS FROM POOL | | | EQUIPMENT TO PROPERTY LINES. | | | | | | | | | CHRIS HOOPS | | | ZONING TECHNICIAN | | | 561-805-6720 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-05-04 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-05-04 |
Time |
15:48 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-05-04 |
Time |
15:48 |
Sent To |
I |
|
| Notes |
| 2007-05-04 15:53:49 | ***FAILED***] | | | | | | | | | 1)NEED TO MEET REQUIREMENTS FOR A PERMANENT FENCE | | | AROUND A POOL, SET FORTH IN:THE CITY OF WEST PALM | | | BEACH ZONING AND LAND DEVELOPMENT REGULATIONS, SECTION | | | 94-304(D)(2)(B)+(C): | | | | | | B.EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE | | | OR SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT | | | ACCESS BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF | | | THE RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED. | | | BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN | | | HEIGHT ABOVE GRADE. | | | | | | C.ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE | | | THROUGH A BUILDING OR THROUGH A SELF-CLOSING AND | | | SELF-LATCHING GATE OR THROUGH A SCREEN ENCLOSURE DOOR | | | WITH LATCHES PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF | | | GATE. AT LEAST 90 PERCENT OF THE SURFACE AREA OF ALL | | | SCREEN ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH | | | WHICH AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT | | | SHALL BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A | | | 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE, | | | AT THE PROPERTY LINE, TO ENSURE PRIVACY. | | | | | | | | | CHRIS HOOPS | | | ZONING TECHNICIAN | | | 561-805-6720 |
|
|