Plan Review Details - Permit 07050091
Plan Review Stops For Permit 07050091
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-08-09 Cont ID  
Sent By jgomez Date 2007-08-09 Time 16:50 Rev Time 0.00
Received By jgomez Date 2007-08-09 Time 14:10 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-07-27 Cont ID  
Sent By jgomez Date 2007-07-27 Time 17:49 Rev Time 0.00
Received By jgomez Date 2007-07-27 Time 17:49 Sent To PC
Notes
2007-07-27 18:43:43BUILDING REVIEW 3RD CHECKLIST:
 1- DRAWINGSA2 AND A3 ARE NOT SIGNED, SEALED AND DATED
 BY THE ARCHITECT AS REQUIRED BY CHAPTER 481 FLORIDA
 STATUTE.
  
 2- ARCHITECT NEEDS TO REVIEW TABLE ONPAGE 45 OF ASCE
 7-02 OR REVISED TABLE 1609.6.2.1(2) OF FBC 2004 TO SEE
 THE DESIGN PRESSURES AT CORNER AREAS.PRODUCT
 APPROVAL NOA 07-0301.01 FOR METAL ROOF PANELS SUBMITTED
 STILL DOESN'T MEET THE DESIGN PRESSURES AT CORNER
 AREAS. THEREFORE IT CAN'T BE USED IN THIS AREA. NEED TO
 PROVIDE PRODUCT APPROVAL THAT MEETS THE DESIGN
 PRESSURES FOR ALL ZONES.
  
 3- NOTICE OF COMMENCEMENT SUBMITTED WAS RECORDED ON
 03/29/2007.NOTICE OF COMMENCEMENT IS EXPIRED AFTER
 90 DAYS IF WORK IS NOT STARTED. SEE SEC. 713.13 FLORIDA
 STATUTE. NEED TO PROVIDE RE-RECORDED NOTICE OF
 COMMENCEMENT.
  
 4- PROVIDE PRODUCT APPROVALSAS REQUIRED BY DCA RULE
 9B-72 FOR:
 A)ALL USP STRUCTURAL CONNECTORSSPECIFIED ON
 PLANS.SEE TRUSS ANCHOR SCHEDULE, COLUMN CONNECTORS
 AT TOP AND BOTTOM,ETC.
  
 B) EXTERIOR SWING DOORS AS SHOWN ON PLANS.ONLY ONE
 PRODUCT APPROVAL WAS SUBMITTED AND IT WAS ASSUMED THAT
 IT WAS FOR THE GARAGE SIDE DOOR SINCE IS THE ONLY ONE
 THAT MATCHES THE SIZE SPECIFIEDON PLANS. IT WAS
 REQUESTED ON PREVIOUS CHECKLIST TO IDENTIFY IF PRODUCT
 APPROVAL WAS FORENTRY DOOR, REAR DOOR OR SIDE GARAGE
 DOOR.
 NEED TO PROVIDE PRODUCT APPROVAL FOR ENTRY DOOR AND
 REAR DOOR. SEE PLANS FOR SPECIFIED SIZE.
  
 5- REMAINDER: ARCHITECT TO REVIEW AND APPROVE IN
 WRITING ALL PRODUCT APPROVALS PRIOR TO SUBMITTAL TO
 THIS OFFICE. SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
  
 6- STRUCTURAL BUCK DETAILS TO MATCH INFORMATION GIVEN
 ON FASTENER SCHEDULE ON SHEET A3.
  
 7- SHEET A2: THERE ARE TWO DIFFERENT TYPES OF
 CONSTRUCTION TYPES SPECIFIED ON WIND DESIGN
 INFORMATION. REVISE AS REQUIRED AND PROVIDE CORRECT
 INFORMATION. SEE SEC. 602.1 FBC 2004.ALSO, BE
 SPECIFIC IF CONSTRUCTION TYPE IS A OR B.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-07-17 Cont ID  
Sent By jgomez Date 2007-07-17 Time 13:43 Rev Time 0.00
Received By jgomez Date 2007-07-17 Time 13:42 Sent To PC
Notes
2007-07-17 14:04:02BUILDING REVIEW SECOND CHECKLIST:
 1-PROVIDE RECORDED NOTICE OF COMMENCEMENT AS REQUIRED
 BY SEC. 713.13 FLORIDA STATUTE.
  
 2- PERMIT VALUATION WAS UPDATED USING THE REVISED
 VALUATION SHOWN ON THE PERMIT APPLICATION.OWES
 $1026.14 FOR PERMIT VALUATION AND RADON FEES.
  
 3- PROVIDE 2 COPIES OF PRODUCT APPROVALS AS REQUIRED BY
 DCA RULE 9B-72 FOR:
 A) METAL ROOF PANEL.NOA 06-0317.05 SUBMITTED IS
 GOOD FOR UP TO -45PSF ONLY.ACCORDING TO SYSTEM
 LIMITATION #1 ON PAGE 4 NAIL ENHANCING IS NOT ALLOWED.
 NEED TO PROVIDE PRODUCT APPROVAL THAT MEETS THE DESIGN
 PRESSURES AT PERIMETER AND CORNER AREAS.
 ***CLARIFY WHY ARCHITECT APPROVED THIS PRODUCT IF IT
 DOESN'T MEET THE DESIGN PRESSURES.
  
 B) GARAGE DOOR AS SHOWN ON PLANS.NOA03-0430.04
 SUBMITTED IS FOR 9'-0" WIDE DOORS. PLANS CALL FOR
 10'-0" WIDE DOORS.
 *** CLARIFY WHY ARCHITECT APPROVED THIS PRODUCT IF IT
 DOESN'T WORK FOR THE SIZE SPECIFIED ON PLANS. ALSO,
 PROVIDE 2 COPIES WITH LEGIBLE DRAWINGS.
  
 C) ALL USP STRUCTURAL CONNECTORS SPECIFIED ON
 PLANS.
  
 PROVIDE PRODUCT APPROVAL COVER PAGE AND PAGE SHOWING
 THE CONNECTORS ONLY. NOT NEED TO SUBMIT COMPLETE
 REPORT.
  
 D) EXTERIOR SWING DOORS. CLEARLY IDENTIFY PRODUCT
 APPROVAL FOR ENTRY DOOR,REAR DOOR AND GARAGE SIDE
 DOOR.
 ALSO, THERE IS ONLYONE COPY SUBMITTED FOR JELD-WEN
 DOOR.
 ALSO, CHECKDOOR SIZES SPECIFIED ON PLANS TO MAKE SURE
 CORRECT PRODUCT APPROVAL IS SUBMITTED.
  
 E) GLASS BLOCK.
  
 F) PROVIDE ONLY THE PRODUCT APPROVALS THAT APPLY TO
 THIS PROJECT. THERE ARE SOME PRODUCT APPROVALS FOR
 FIXED WINDOWS THAT DON'T APPLY TO THIS JOB.
 ALSO, REVISE DESIGN PRESSURES FOR COMPONENTS AND
 CLADDING SCHEDULE. IT DOESN'T MATCH PLANS SUBMITTED.
 NOTE: THIS SCHEDULE IS NOT REQUIRED. REQUIRED
 INFORMATIONIS ON SHOWN ON PLANS.THIS SCHEDULE JUST
 CONFUSES THE INFORMATION WHEN IT DOESN'T MATCH PLANS.
  
 4- GLASS BLOCK PRODUCT APPROVAL TO BE REVIEWED AND
 APPROVED IN WRITING BY ARCHITECT AS REQUIRED BY SEC.
 106.3.3 CITY AMENDMENTS TO FBC 2004.
  
 5- STRUCTURALBUCK DETAILS FOR DOORS AND WINDOWS TO
 MATCH INFORMATION GIVEN ON FASTENER SCHEDULE SHOWN ON
 SHEET A3.
  
 6- REVISE INFORMATION GIVEN ON FASTENER SCHEDULE ON
 SHEET A3.NAIL SIZE SPECIFIED FOR WIRE LATH
 INSTALLATION ON SOFFIT IS INCORRECT.SEE ASTMC-926
 AND ASTM C1063FOR CORRECT SIZE AND SPACING TO BE
 SPECIFIED. SEC. 106.1.2 CITY AMENDMENTS TO FBC
 2004.
  
 7- ENERGY CALCULATIONS:
 A) ARCHITECT TO PROVIDE HIS NAME AS REQUIRED BY
 CHAPTER 481 FLORIDA STATUTE AND SEC. 61G1-16.004
 FLORIDA ADMINISTRATIVE CODE.
  
 B) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM
 ALSO.
  
 8- TYPE OF CONSTRUCTION SPECIFIED BY THE ARCHITECT IS
 INCORRECT.THERE IS NOT TYPE VI ON FBC 2004. REVISE
 AS REQUIRED. SEE SEC. 602.1 FBC 2004.
  
 9- AREA CALCULATIONS FOR NEW PORCH IS INCORRECT. REVISE
 AS REQUIRED.ALSO, REVISE TOTAL AREA AS REQUIRED.
  
 10- SHEET A4:
 A) SPECIFYCOLUMN TOP CONNECTORS AT CORNER AREAS OF
 NEW PORCH. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 11- ROOF SHEATHING NOTE AND INFORMATION GIVEN ON
 FASTENER SCHEDULE SHEET A3 DON'T MATCH REVISE AS
 REQUIRED.ALSO, CLARIFY NOTE REGARDING ZONE 3 (GABLE
 END). ROOF ZONE 3 IS NOT ONLY FOR GABLE ENDS. REVISE AS
 REQUIRED.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-06-19 Cont ID  
Sent By jgomez Date 2007-06-19 Time 16:48 Rev Time 0.00
Received By jgomez Date 2007-06-19 Time 16:48 Sent To PC
Notes
2007-06-19 16:58:58BUILDING REVIEW CHECKLIST:
 1- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY
 SEC. 713.13 FLORIDA STATUTE.
  
 2- AFTER PLANS ARE REVISED BRING THEM TO PALM BEACH
 COUNTY(2300 N. JOG RD (561)233-5115)TO PAY IMPACT
 FEES.BRING BACK STAMPED PLANS AND COPY OF PAID
 RECEIPT.
  
 3- DECLARED VALUATION IN PERMIT APPLICATION IS TOO LOW.
 SEC. 108.3 CITY AMENDMENTS TO FBC 2004.PLEASEUPDATE
 VALUATION AND INCLUDE ALSODEMOLITION AND PROFESSIONAL
 ARCHITECT/ENGINEER SERVICES.
  
  
 4-CLARIFY WHY DEMOLITION PLAN CALLS FOR "CUT EXISTING
 TIE BEAM" AT OPENING AREAS.HOW IS THE TIE BEAM
 REINFORCED IF IT'S CUT DOWN?. SEC. 106.1.2 CITY
 AMENDMENTS STO FBC 2004.
  
 5- SPECIFY ATTIC ACCESS SIZE. SEC. R807 OF 2004 FLORIDA
 RESIDENTIAL CODE.
  
 6- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE
 9B-72 FOR:
 A) 18" DIAMETER SUNTUBE SKYLIGHTS.
  
 B) SLIDING GLASS DOORS. NOA 05-0112.02 SUBMITTED WAS
 SUPERSEDED ACCORDING TO DADE COUNTY PRODUCT APPROVAL
 WEBSITE. SEE ATTACHED COPY.PROVIDE COPIES OF CURRENT
 NOA.
  
 C) METAL ROOF PANEL. NOA 06-0317.05 SUBMITTED IS
 GOOD FOR UP TO -45PSF MAXIMUM ALLOWABLE UPLIFT
 PRESSURE.UPLIFT PRESSURES CAN'T BE UPGRADED. SEE
 SYSTEM LIMITATIONS ON PAGE 4 OF NOA SUBMITTED.NEED TO
 PROVIDE PRODUCT APPROVAL THAT WILL RESIST THE UPLIFT
 LOADS AT PERIMETER AND CORNER AREAS AS INDICATED ON
 REVISED TABLE 1609.6.2.1(2) OF FBC 2004. (10PSF
 MINIMUM TRIBUTARY AREA).
  
 D) GARAGE DOOR AS SHOWN ON PLANS.
  
 E) ALL USP CONNECTORS SPECIFIED ON PLANS.
  
 F) ALL EXTERIOR SWING DOORS AS SHOWN ON
 PLANS/ELEVATIONS.AND, CLEARLY IDENTIFY WHICH ONE IS
 ENTRY DOOR, GARAGE SIDE DOOR, ETC.
  
 G) GLASS BLOCK.
  
 H) PRECAST LINTELS.
  
 ***NOTE:PROVIDE ONLY PRODUCT APPROVALS THAT APPLY TO
 THIS PROJECT. THERE IS A PRODUCT APRPOVAL SUBMITTED FOR
 CASEMENT WINDOWS. PLANS DON'T SHOW ANY CASEMENT
 WINDOWS.
  
 7- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 ALL PRODUCT APPROVALS AS REQUIRED BY SEC. 106.3.3 CITY
 AMENDMENTS TO FBC 2004.
  
 8-STRUCTURAL BUCK DETAILS FOR DOORS AND WINDOWS TO
 MATCH INFORMATION GIVEN ON FASTENER SCHEDULE. ALSO, SEE
 WINDOWS AND DOORS PRODUCT APPROVALS TO VERIFY MINIMUM
 BUCK SIZE REQUIRED AND COORDINATE DETAILS/SPECS
 ACCORDINGLY.
  
 9- ENERGY CALCULATIONS:
 A) OWNER/AGENT TO SIGN AND DATE AT BOTTOM OF FORM.
  
 B) ARCHITECT TO PROVIDE HIS NAME AND LICENSE NUMBER
 ON ALL SHEETS THAT HE'S SIGNING AND SEALING AS REQUIRED
 BY CHAPTER 481 FLORIDA STATUTE AND SEC. 61G1-16.004 OF
 FLORIDA ADMINISTRATIVECODE.
  
 10- SHEET A2:
 A) FLOOR PLAN CALLS FOR "HOR SLDR"WINDOWS BY
 LIBRARY AREA, WHILE LEFT SIDE ELEVATION SHOWS FIXED
 WINDOWS. CLARIFY/REVISE AS REQUIRED.
  
 B) SPECIFY TYPE OF CONSTRUCTION AS REQUIRED BYSEC.
 602.1 FBC 2004."CONCBLK"CONSTRUCTION IS NOT A
 COMPLETE DESCRIPTION.
  
 11- SHEET A4:
 A) SPECIFY CONNECTORS AT THE ENDS AND CORNERS OF
 (3)2X12 BEAMS AT NEW ENTRY PORCH. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 B) MINIMUM ROOF SHEATHING TYPE OF NAIL IS 8D RING
 SHANK NAILS AS REQUIRED BYSEC. R803.2.3.1 OF 2004
 FLORIDA RESIDENTIAL CODE. REVISE ROOF SHEATHING NOTE AS
 REQUIRED.
  
 C) WALL SECTION G/4:SPECIFY 12" MIN. FOOTING DEPTH
 BELOW GRADE AS REQUIRED BY SEC. R403.1.4OF 2004
 FLORIDA RESIDENTIAL CODE.
  
 ***NOTE:
 PLEASE DON'T STAPLE PRODUCT APPROVALS TO PLANS.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2008-02-14 Cont ID  
Sent By btrobaug Date 2008-02-14 Time 14:59 Rev Time 0.00
Received By btrobaug Date 2008-02-14 Time 14:23 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-07-09 Cont ID  
Sent By btrobaug Date 2007-07-09 Time 08:48 Rev Time 0.00
Received By btrobaug Date 2007-07-09 Time 08:46 Sent To M
Notes
2007-07-09 08:47:13 
  
  
  
 PROVISO
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE
 COMPLIANCE AND RESUBMIT FOR REVIEW PRIOR TO ROUGH
 INSPECTION.
  
 NOTE: SEE 13-606.1.ABC.1.2.3 FBC FOR REQUIREMENTS FOR
 RECESSED LIGHTING FIXTURES INSTALLED IN CEILINGS THAT
 ABUT AN ATTIC SPACE. ALSO SEE THE DEFINITION OF "SMOKE
 DETECTORS" 11.8.2.1 NFPA-72, CLARIFY IF USING DETECTORS
 OR ALARMS, TO AVOID CONFUSION IN THE FIELD.
  
 1} PER 110.9 AND 110.10: OBTAIN THE
 AVAILABLE FAULT CURRENT AT THE UTILITY
 AND CALCULATE THE SAME AT THE EQUIPMENT.
 INDICATE THE AIC RATING FOR THE
 EQUIPMENT IS EQUAL TO OR GREATER THAN
 THE AVAILABLE FAULT.
  
 2} THE RISER DIAGRAM INDICATES A METER/MAIN
 COMBINATION, AND AT THE SERVICE LOCATION ON THE
 DRAWING, A DISCONNECT IS INDICATED SEPARATELY. PLEASE
 CLARIFY.
  
 2}A RECEPTACLE MUST BE ADDED TO THE MASTER BATH
 COUNTER TO COMPLY WITH 210.53(D).
  
 3} THE DINING ROOM RECEPTACLES NEED TO BE CIRCUITED ON
 A 20 AMP CIRCUIT PER 210.52 (B)(1), AND SHALL HAVE "NO
 OTHER OUTLETS", SEE 210.52(B)(2).
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-05-11 Cont ID  
Sent By btrobaug Date 2007-05-11 Time 12:03 Rev Time 0.50
Received By btrobaug Date 2007-05-11 Time 10:04 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2008-02-25 Cont ID  
Sent By adarroug Date 2008-02-25 Time 08:39 Rev Time 0.00
Received By adarroug Date 2008-02-25 Time 08:39 Sent To M
Notes
2008-02-25 08:40:44TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2008-02-06 Cont ID  
Sent By adarroug Date 2008-02-06 Time 14:46 Rev Time 0.00
Received By adarroug Date 2008-02-06 Time 14:46 Sent To E
Notes
2008-02-06 14:46:46TO "BTROBAUG" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-08-06 Cont ID  
Sent By adarroug Date 2007-08-06 Time 18:10 Rev Time 0.00
Received By adarroug Date 2007-08-06 Time 18:10 Sent To P
Notes
2007-08-06 18:10:16TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-07-23 Cont ID  
Sent By adarroug Date 2007-07-23 Time 15:56 Rev Time 0.00
Received By adarroug Date 2007-07-23 Time 15:56 Sent To Z
Notes
2007-07-23 15:56:45TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-07-05 Cont ID  
Sent By adarroug Date 2007-07-05 Time 16:44 Rev Time 0.00
Received By adarroug Date 2007-07-05 Time 16:44 Sent To Z
Notes
2007-07-05 16:45:08TO "Z" BOX/RESUB--NEW ELECTRICAL SHEETS SUBMITTED

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-05-07 Cont ID  
Sent By adarroug Date 2007-05-07 Time 16:23 Rev Time 0.00
Received By adarroug Date 2007-05-07 Time 16:23 Sent To E
Notes
2007-05-07 16:23:50TO "SFR" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-06-19 Cont ID  
Sent By jgomez Date 2007-06-19 Time 16:59 Rev Time 0.00
Received By jgomez Date 2007-05-03 Time 15:25 Sent To  
Notes
2007-05-03 15:25:39TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2008-02-27 Cont ID  
Sent By tgordon Date 2008-02-27 Time 14:02 Rev Time 0.45
Received By tgordon Date 2008-02-27 Time 14:02 Sent To  
Notes
2008-02-27 14:03:30REVISION TO MECH. PLAN, E. CAL'S. AND COOLING LOAD
 CAL'S.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status F Date 2008-02-25 Cont ID  
Sent By tgordon Date 2008-02-25 Time 15:12 Rev Time 0.30
Received By tgordon Date 2008-02-25 Time 15:12 Sent To  
Notes
2008-02-25 15:14:49PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 ** REVISION TO MECHANICAL PLAN **
 *** DENIED ***
 1) AS NOTED IN LAST REVIEW 2-15-08 NOTE #1 AS THE
 REVISION SHOWS TWO A/C SYSTEMS TOTALING 6.5 TONS IS NOW
 BEING INSTALLED THE COOLING LOAD CALCULATIONS WILL ALSO
 NEED TO BE REVISED, SEE 2004 FBC 13-103.1.2. COOLING
 LOAD CALCULATIONS ON FILE ARE CALLING FOR 47,052 TOTAL
 COOLING BTU'S, REVISED MECHANICAL PLAN IS CALLING FOR A
 TOTAL OF 76,700 COOLING BTU'S.THE PLANS CAN ONLY CALL
 FOR 15% MORE THAN THE COOLING LOAD CALCULATIONS, SEE
 2004 FBC 13-607.1.ABC.1.1.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 4 Status F Date 2008-02-15 Cont ID  
Sent By tgordon Date 2008-02-15 Time 10:32 Rev Time 0.35
Received By tgordon Date 2008-02-15 Time 10:32 Sent To  
Notes
2008-02-15 10:51:42PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM
 BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA
 ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES
 (F.S.).
  
 ** MECHANICAL REVISION **
 *** DENIED ***
 1) AS THE REVISION SHOWS TWO A/C SYSTEMS TOTALING 6.5
 TONS IS NOW BEING INSTALLED THE COOLING LOAD
 CALCULATIONS AND ENERGY CALCULATIONS WILL NEED TO BE
 REVISED, SEE 2004 FBC 13-103.1.2.
  
 2) WHEN SUBMITTING REVISED ENERGY CALCULATIONS PLEASE
 HAVE THEM SIGNED BY OWNER/AGENT ALSO, PER 2004 FBC
 13-600.3.ABC.2.
  
 3) PLEASE PROVIDE COMBUSTION AIR AND MAKE UP AIR
 CALCULATION AND/OR COMBUSTION AND MAKE UP AIR FOR THE
 GAS CLOTHES DRYER IN THE UTILITY ROOM AS IT APPEARS TO
 BE A CONFINED SPACE, SEE 2004 FBC/R G2407.1 AND
 G2407.4.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2007-07-24 Cont ID  
Sent By tgordon Date 2007-07-24 Time 11:13 Rev Time 0.25
Received By tgordon Date 2007-07-24 Time 11:13 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2007-07-09 Cont ID  
Sent By tgordon Date 2007-07-09 Time 09:33 Rev Time 0.30
Received By tgordon Date 2007-07-09 Time 09:33 Sent To P
Notes
2007-07-09 09:36:11*** DENIED ***
 1) AS REQUESTED IN LAST REVIEW 5-15-07. ENERGY
 CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT ALSO, PER
 2004 FBC 13-600.3.ABC.2.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-05-15 Cont ID  
Sent By tgordon Date 2007-05-15 Time 13:23 Rev Time 0.30
Received By tgordon Date 2007-05-15 Time 13:23 Sent To P
Notes
2007-05-15 13:32:42*** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT
 ALSO, PER 2004 FBC 13-600.3.ABC.2.
  
 2) AS THEIR IS NO DOOR SCHEDULE PLEASE NOTE ON PLANS
 DOOR TO THE AHU CLOSET NEEDS TO BE LOUVERED FOR RETURN
 AIR.
  
 3) THE RETURN AIR TRANSFER DUCT TO BEDROOM #3 NEEDS TO
 BE SIZED.
  
 4) PROVIDE FOR RETURN AIR TO THE LIBRARY AND MASTER
 SUITE.
  
 INFORMATIONAL: BALANCED RETURN AIR MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY INCREASING THE
 RETURN TRANSFER ONE AND ONE HALF TIMES THE CROSS
 SECTIONAL AREA (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING AND THE DOOR
 HAVING AT LEAST AN UNRESTRICTED 1 INCHUNDERCUT TO
 ACHIEVE PROPER RETURN AIR BALANCE.
 (C)HABITABLE ROOMS ONLY SHALL BE REQUIRED TO MEET
 THESE REQUIREMENTS FOR PROPER BALANCED RETURN AIR
 EXCLUDING BATHROOMS, CLOSETS, STORAGE ROOMS AND LAUNDRY
 ROOMS, EXCEPT THAT ALL SUPPLY AIR INTO THE MASTER SUITE
 SHALL BE INCLUDED. PER 2004 FBC/R M1602.4 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-07-13 Cont ID  
Sent By mperson Date 2007-07-13 Time 15:52 Rev Time 0.33
Received By mperson Date 2007-07-13 Time 15:52 Sent To Z
Notes
2007-07-13 15:56:51****************PROVISO****************
 (A) 708.3.5 BUILDING DRAIN AND BUILDING
 SEWER JUNCTION. THERE SHALL BE A TWO-WAY
 CLEANOUT NEAR THE JUNCTION OF THE
 BUILDING DRAIN AND THE BUILDING SEWER.
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-05-17 Cont ID  
Sent By mperson Date 2007-05-17 Time 15:28 Rev Time 0.50
Received By mperson Date 2007-05-17 Time 15:28 Sent To B
Notes
2007-05-17 16:07:03DENIED
 REFERENCE:
 ** FBC-2004 PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. SHEET A3 SANITARY ISOMETRIC RISER DIAGRAM DOES NOT
 REFLECT THE FLOOR PLAN. THE NEW LAUNDRY TRAY IN THE
 UTILITY ROOM INDICATED ON SHEETS A2 AND A3 IS MISSING
 FROM THE THE SANITARY RISER DIAGRAM AS WELL AS THE
 RELOCATION OF THE WASHING MACHINE. PER FBC-2004 CHAPTER
 1, SECTION 106.3.5.4 (9) PLUMBING, PLEASE INDICATE
 THOSE CHANGES ON THE RESUBMITTAL.
 NOTE: THE FOLLOWING IS REQUIRED FOR THE WASHING
 MACHINE.
  
 (A) 406.3 WASTE CONNECTIONS.THE TRAP AND
 FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES
 WASHER SHALL BE A MINIMUM OF 2 INCHES
 (51MM) IN DIAMETER. THE AUTOMATIC
 CLOTHES WASHER FIXTURE DRAIN SHALL
 CONNECT TO A BRANCH DRAIN OR DRAINAGE
 STACK A MINIMUM OF 3 INCHES (76MM) IN
 DIAMETER.
 (B) 802.4 STANDPIPES.STANDPIPES SHALL BE INDIVIDUALLY
 TRAPPED. STANDPIPES SHALL
 EXTEND A MINIMUM OF 18 INCHES (457MM)
 AND A MAXIMUM OF 42 INCHES (1066MM)
 ABOVE THE TRAP WEIR. ACCESS SHALL BE
 PROVIDED TO ALL STANDPIPES AND DRAINS
 FOR RODDING.
 NOTE: PLEASE INDICATE THE STANDPIPE ON THE RESUBMITTED
 DRAWINGS.
 (C) 708.7 MINIMUM SIZE. CLEANOUTS SHALL
 BE THE SAME NOMINAL SIZE AS THE PIPE
 THEY SERVE UP TO 4 INCHES (102MM)
 NOTE: THE CLEANOUT FOR THE WASHING MACHINE SHALL BE
 THREE INCH (3").
 (D) 708.9 ACCESS. ACCESS SHALL BE
 PROVIDED TO ALL CLEANOUTS.
 NOTE: THE CLEANOUT FOR THE WASHING MACHINE SHALL BE
 LOCATED AT FOUR FEET ABOVE FINNISH FLOOR (4'A.F.F.).
  
 2. SHEET A3 NEW KITCHEN SINK SANITARY ISOMETRIC RISER
 DIAGRAM PLEASE INDICATE THE DISHWASHER DISCHARGE INTO A
 WYE-BRANCH FITTING ON THE TAILPIECE OF THE KITCHEN SINK
 OR THE DISHWASHER CONNECTION OF A FOOD WASTE GRINDER
 PER FBC-2004 PLUMBING, SECTION 802.1.6 ON THE
 RESUBMITTAL.
  
 3. SHEET A3 WATER HEATER PIPING DIAGRAM: PLEASE
 INDICATE A MEANS OF CONTROLLING INCREASED PRESSURE
 CAUSED BY THERMAL EXPANSION AS REQUIRED IN ACCORDANCE
 WITH FBC-2004 PLUMBING, SECTIONS 607.3.1 AND 607.3.2 ON
 THE RESUBMITTAL.
  
 4. SHEET A3 FOUNDATION PLAN THE RANGE AND KITCHEN SINK
 WITH DISHWASHER AND DISPOSAL ARE INDICATED IN THE WRONG
 LOCATION PER SHEET A2 ARCHITECTURAL FLOOR PLAN. PLEASE
 CORRECT AND CORRELATE THIS ON THE RESUBMITTAL.
  
 ********IMPORTANT INFORMATION********
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY.
 NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop Z ZONING
Rev No 3 Status P Date 2007-07-24 Cont ID  
Sent By choops Date 2007-07-24 Time 10:41 Rev Time 0.00
Received By choops Date 2007-07-24 Time 10:41 Sent To M
Notes
2007-07-24 10:42:08PROVISO:LANDSCAPING MUST BE UP TO CODE.

Review Stop Z ZONING
Rev No 2 Status F Date 2007-07-16 Cont ID  
Sent By choops Date 2007-07-16 Time 09:10 Rev Time 0.00
Received By choops Date 2007-07-16 Time 09:10 Sent To B
Notes
2007-07-16 09:14:25***FAILED***
  
  
 1)DIMENSIONS ON SURVEYS DO NOT CORRESPONDE WITH
 DIMENSIONS SHOWN ON SITE PLAN PROPOSED ADDITIONS.
  
 2)NEW PLANS SHOW DRIVEWAY BEING REMOVED.IS A
 PROPOSED DRIVEWAY TO BE INCLUDED IN THE SCOPE OF WORK
 FOR THIS PERMIT?IF SO, PROVIDE DIMENSIONS AND SQUARE
 FOOTAGE OF DRIVEWAY WITHING THE FRONT YARD (FRONT
 PROPERTY LINE TO FRONT OF STRUCTURE)INDICATE IF
 APPROACHES TO BE ALTERED/INCLUDED IN SCOPE OF WORK.
  
 3)SHOW SETBACK DIMENSION TO PROPOSED ENTRY ON
 SURVEYS.
  
  
 QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, ZONING
 TECHNICIAN
 (561)805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2007-05-04 Cont ID  
Sent By choops Date 2007-05-04 Time 16:07 Rev Time 0.00
Received By choops Date 2007-05-04 Time 16:07 Sent To I
Notes
2007-05-04 16:10:48***FAILED***
  
  
 1)PLEASE PROVIDE ELEVATION FROM GRADE TO MIDPOINT OF
 THE ROOF'S PITCH.
  
 2)PLEASE PROVIDE 2 COPIES OF AN ACTUAL SURVEY WITH
 SCOPE OF WORK, DIMENSIONS OF WORK, AND DIMENSIONS FROM
 PROPERTY LINES TO WORK, CLEARLY MARKED.
  
 3)SHOW ANY PROPOSED MECHANICAL EQUIPMENT AND
 DISTANCES TO PROPERTY LINES.
  
  
 CHRIS HOOPS
 ZONING TECHNICIAN
 561-805-6720