| Plan Review Stops For Permit 07050059 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
P |
Date |
2008-02-26 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2008-02-26 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2008-02-26 |
Time |
08:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-11-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-11-06 |
Time |
07:40 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2007-11-06 |
Time |
07:21 |
Sent To |
|
|
| Notes |
| 2007-11-06 07:41:47 | BUIOLDING PROVISO: | | | BREAK ROOMS/ CATERING AREAS, NO DOORS AT SINK BASE | | | 11-4.24.5 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-09-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-09-19 |
Time |
11:24 |
Rev Time |
1.55 |
| Received By |
jwitmer |
Date |
2007-09-19 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2007-09-19 11:26:20 | | | | BUILDING PLAN REVIEW | | | PERMIT: 07050059 | | | ADD: 525 OKEECHOBEE BLVD SUITE# 1100 | | | CONT: BALFOUR BEATTY CONSTRUCTION | | | TEL: (561)478-0381 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2NDREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT | | | STATEMENT --- | | | PLEASE DO NOT | | | IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2 ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3-6) COMPLIED. | | | | | | 7)SECOND REQUEST, CAF? AND CATERING ROOM SHEET A012.04 | | | DETAIL# 6, THE DETAIL INDICATES THE USE OF DOORS IN | | | FRONT OF THE ACCESSIBLE SINK, THESE DOORS NEED TO BE | | | REMOVED FOR A FRONTAL APPROACH. WITH DOORS ON THE | | | CABINET THERE WILL BE A TENDENCY TO STORE ITEMS ON THE | | | FLOOR THAT WOULD NOT ALLOW ACCESSIBILITY. | | | SINKS. SECTION 11-4.2.4 SHALL BE PROVIDED IN FRONT OF A | | | SINK TO ALLOW FORWARD APPROACH. THE CLEAR FLOOR SPACE | | | SHALL BE ON AN ACCESSIBLE ROUTE AND SHALL EXTEND A | | | MAXIMUM OF 19 INCHES (485 MM) UNDERNEATH THE SINK. | | | | | | 8) NEW COMMENT, DEALS WITH THE STRUCTURAL SHEET, SINCE | | | THE NEW STRUCTURAL BEAM IS NOT | | | GOING TO BE A REVISION UNDER THE BASE BUILDING THE | | | FOLLOWING INFORMATION WILL BE REQUIRED: | | | 8A)105.13.1 THE ENFORCING AGENCY SHALL REQUIRE A | | | SPECIAL INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON | | | A THRESHOLD BUILDING PURSUANT TO A "STRUCTURAL | | | INSPECTION PLAN" | | | PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL | | | INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING | | | AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR | | | THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE | | | OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE | | | SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT | | | THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE | | | WITH THE PERMITTED DOCUMENTS. | | | | | | 8B) THE SHELL BUILDING HAS NOT ACHIEVED A CERTIFICATE | | | OF COMPLETION, THE STRUCTURAL PLANS FOR THIS TENANT | | | SPACE SHALL BE REVIEWED BY THE ENGINEER OF RECORD FOR | | | THE " BASE BUILDING" | | | AND BE STAMPED WITH THEIR SHOP DRAWING STAMP THEY ARE | | | APPROVING THE PLANS AND WORK TO BE COMPLETED UNDER THIS | | | PERMIT BEFORE THEIR CERTIFICATE OF COMPLETION HAS BEEN | | | ISSUED. | | | | | | 8C) THE SAME HOLDS TRUE FOR THE ARCHITECTURAL SHEETS, | | | THE DESIGNER OF RECORD FOR THE BUILDING SHALL REVIEW | | | AND AFFIX THEIR SHOP DRAWING STAMP TO THESE PLANS WITH | | | THEIR APPROVAL. | | | | | | 8D) SINCE THERE WILL NEED TO BE A THRESHOLD INSPECTOR | | | ON SITE, A THIRD SET OF PLANS, SUBMITTALS AND OR OTHER | | | DOCUMENTS WILL NEED TO BE SUBMITTED BEFORE ISSUANCE OF | | | THIS PERMIT. | | | | | | 8E) SINCE THE STEEL BEAMS ARE NEW ELEMENTS AND NEED TO | | | INDICATE FIRE PROOFING AS TO TABLE 601 FLOOR AND BEAM 3 | | | HR RATING SEE FOOTNOTE "G" 1 HR REDUCTION FOR FIRE | | | SPRINKLED BUILDINGS. | | | PLEASE SHOW COMPLIANCE. | | | | | | 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS | | | OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF | | | CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST | | | RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT | | | BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC | | | REQUIREMENT, THE SPECIFIC | | | REQUIREMENT SHALL BE APPLICABLE. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | | | | | | | | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-06-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-06-18 |
Time |
12:03 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2007-06-18 |
Time |
12:03 |
Sent To |
|
|
| Notes |
| 2007-06-18 13:16:44 | BUILDING PLAN REVIEW | | | PERMIT: 07050059 | | | ADD: 525 OKEECHOBEE BLVD # 1100 | | | CONT: BALFOUR BEATTY CONST | | | TEL: (561)478-0381 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2) IF THE | | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3) SHEET 00.000 CODE SUMMARY INDICATES THE DESIGN IS | | | THE FBC 2004, PLEASE INDICATE THE CODE UPDATES PLANS | | | SUBMITTED AFTER DEC.8/06 SHOULD HAVE BEEN DESINED TO | | | THE 2004 FBC WITH 2006 AMENDMENTS. | | | | | | 4A) A012.02 DOOR DETAILS PLEASE SHOW FIRE TREATED WOOD | | | BUCKS. SECTION 603. | | | | | | 4B) THE DOUBLE FRONT ENTRY DOORS DO NOT SHOW ON THE | | | DOOR SCHEDULE NOR ARE THEY INDICATED AS EXISTING? | | | 106.1.2* ADDITIONAL INFORMATION REQUIRED. | | | | | | 5) IT ROOM INDICATES 1 HR FIRE RATED WALLS BUT THE DOOR | | | 11JO5 IS NOT RATED? | | | | | | 6) SHEET A012.03 DETAIL # 2 PLEASE PROVIDE MANUFACTURES | | | INFORMATION FOR THIS DOOR SYSTEM, DETAIL# 3 INDICATES | | | THIS TO BE THE WALL THAT WILL TAKE THE WEIGHT OF THIS | | | TRACK SYSTEM BUT THERE IS NO INFORMATION AS TO HOW TO | | | ATTACH TO THE STRUCTURE ABOVE, AND WHAT TYPE OF | | | STRUCTURE THIS SYSTEM WILL HANG FROM. WHAT IS THE | | | WEIGHT OF THIS PAEN WALL SYSTEM PER FOOT? | | | | | | 7) BOTH THE CAFE AND CATERING ROOMS ARE TO COMPLY WITH | | | : SINKS: | | | 11-4.24.2 SINKS, HEIGHT. SINKS SHALL | | | BE MOUNTED WITH THE COUNTER NO HIGHER | | | THAN 34" ABOVE THE FINISH FLOOR. | | | 11-4.24.3 KNEE CLEARANCE THAT IS AT | | | LEAST 27" HIGH 30" WIDE, AND 19" DEEP | | | SHALL BE PROVIDED UNDERNEATH SINKS. | | | 11-4.24.5 CLEAR FLOOR SPACE. | | | A CLEAR FLOOR SPACE AT LEAST 30 INCHES BY 48 INCHES | | | (760 MM BY 1219 MM) COMPLYING WITH SECTION 11-4.2.4 | | | SHALL BE PROVIDED IN FRONT OF A SINK TO ALLOW FORWARD | | | APPROACH. THE CLEAR FLOOR SPACE SHALL BE ON AN | | | ACCESSIBLE ROUTE AND SHALL EXTEND A MAXIMUM OF 19 | | | INCHES (485 MM) UNDERNEATH THE SINK | | | | | | 8)PLEASE PROVIDE THE MINIMUM CRITICAL RADIANT FLUX | | | FOR THE CARPET. FBC 804.5.1 BUILDING. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
8 |
Status |
P |
Date |
2008-07-14 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-07-14 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-07-14 |
Time |
16:36 |
Sent To |
PC |
|
| Notes |
| 2008-07-14 16:37:29 | REV #17 FOR E0.4 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
7 |
Status |
P |
Date |
2008-06-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-06-16 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-06-16 |
Time |
13:29 |
Sent To |
PC |
|
| Notes |
| 2008-06-16 13:30:40 | E0.2,1.11,2.11 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
6 |
Status |
F |
Date |
2008-05-30 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-05-30 |
Time |
10:18 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-05-30 |
Time |
10:17 |
Sent To |
PC |
|
| Notes |
| 2008-05-30 10:18:50 | ** DENIEDREVIEW ** | | | | | | | | | 1) NOTE: PLEASE SEE THE REVISIONS NOW COMING IN FOR | | | REVIEW DO NOT COORDINATE WITH RECORD PLANS ON FILE. | | | THE LAST REVISION ON FILE WITH THE CITY IS REVISION #6, | | | NOW WE HAVE REVISION #16 COMING IN WITH OUT SHOWING | | | OTHER REVISIONS BETWEEN THE TWO. | | | PLEASE SEE SOME REVISIONS AND CLOUDS ON PLANS, HOWEVER | | | BASED EVEN ON THE #6 REVISION ALREADY ON FILE THERE IS | | | NO CHANGES FROM PREVIOUS PLANS. | | | PLEASE SEE FILE/STORAGE ROOM FOR ONE EXAMPLE. | | | PLEASE SEE OTHER WHICH INDICATES WALL TO BE REMOVED | | | HOWEVER ALL PREVIOUS PLANS NEVER CONTAINED A WALL. THIS | | | IS THE WALL OUTSIDE FLOOR ELECTRICAL ROOM. | | | | | | ** PLEASE COORDINATE ALL. | | | | | | 2) NOTE: THE LETTER SUBMITTED ALONG WITH THE PLANS NOW | | | REQUEST DE-RATINGS FOR HEATER UNITS WHICH CAN NOT BE | | | FOUND IN THE CODE. THE LETTER MENTIONS PROGRAMMING OF | | | SYSTEM AND HOW THE SYSTEM *SHOULD* WORK SO THAT LOADS | | | ARE NOT AT MINIMUM PER NEC. PLEASE KNOW THIS OFFICE IS | | | NOT AWARE OF ANY LOCATION IN THE CODE FOR DE-RATING DUE | | | TO PROGRAMMING OF A SYSTEM OR HOW ONE SYSTEM *SHOULD* | | | OPERATE. 220, 220.51, ETC | | | FBC 106.3.5.1.2 | | | | | | | | | | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. IF | | | THERE ARE ANY QUESTIONS OR COMMENTS PLEASE DO NOT | | | HESITATE IN CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2008-01-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-01-17 |
Time |
18:32 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-01-17 |
Time |
18:32 |
Sent To |
|
|
| Notes |
| 2008-01-17 18:33:07 | REVISIONS, | | | | | | E-0.2, .04, 0.6, 1.11, & 2.11 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-11-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-11-21 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-11-21 |
Time |
12:56 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-11-02 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-11-02 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-11-01 |
Time |
12:05 |
Sent To |
|
|
| Notes |
| 2007-11-03 12:36:21 | ** NOTE ADDED 11/3/07. | | | | | | 1) NOTE: NEED TO VERIFY ON LIGHTING CALCULATIONS SHEET | | | THE ADDITIONAL WATTAGE BEING SHOWN WHICH EXCEEDS THE | | | TABLE ALLOWANCES. IF THERE IS ADDITIONAL WATTAGE IS | | | BEING FIGURED FROM THE CODE PLEASE EXPLAIN AND | | | INDICATE ON TABLE WHICH LOCATIONS/ROOMS ARE USING THE | | | ADDITIONAL WATTAGE WHICH MAY BE PERMITTED UNDER | | | 13-415.2.B.2. | | | ONLY ROOMS WHICH CONTAIN THE LIGHTING FOR DECORATIVE | | | PURPOSES ARE PERMITTED TO USE THE ADDITIONAL WATTAGE OF | | | 1.0 PER SQ FT. IF ROOM ONLY CONTAINS GENERAL LIGHTING, | | | THEN THE TABLE AS SPECIFIED IN13-415.2.B MAY ONLY BE | | | USED. | | 2007-11-02 09:31:56 | | | | ** DENIED 3RD REVIEW ** | | | | | | | | | 1) NOTE: PLEASE SEE COMMENT #1 FROM PREVIOUS REVIEW | | | WHICH SPECIFICALLY GAVE THE FLORIDA ADMINISTRATIVE CODE | | | 61G15-23.002 FOR ALL INFORMATION REQUIRED ON TITLE | | | BLOCKS. PLEASE SEE ONCE MORE THESE WERE NOT COMPLETED. | | | PLEASE SEE THESE ARE STILL MISSING THE REQUIRED PRINTED | | | NAME OF THE ENGINEER ON TITLE BLOCKS. | | | FS 471.025 | | | | | | 2) NOTE: PLEASE SEE THE LIGHT FIXTURE SCHEDULE ON | | | A00.31 DOES NOTE CORRELATE WITH THE LIGHTING FIXTURES | | | ON E-0.2. | | | | | | 3) NOTE: PLEASE SEE 13-415.1.ABC.1.3 AND THE REQUIRED | | | ADDITIONAL CONTROL FOR ACCENT/TASK LIGHTING. PLEASE SEE | | | THE RESPONSE MENTIONS THE FIXTURE *K* WILL HAVE A | | | ROCKER SWITCH. DOES THIS HAVE AN AUTOMATIC WAY OF | | | TURNING OFF? IN SOME LOCATIONS THESE CONTAIN A | | | DESIGNATION LETTER IN WHICH THE ROOM OCCUPANCY SENSOR | | | OR CONTROL DEVICE IS CLEAR HOWEVER THERE ARE LOCATIONS | | | WHICH NO DESIGNATIONS OR CONTROLS COULD BE LOCATED. | | | PLEASE SEE THE *K* FIXTURES IN BETWEEN WHAT APPEARS TO | | | BECAF? 11D03 ANDCOPY 11E03. THESE CONTAIN AN *82* | | | HOWEVER NO OTHER CONTROL DESIGNATION WAS LOCATED. | | | PLEASE SEE THE FOLLOWING NOTE WITH RESPECT TO | | | CIRCUITING AS THIS AFFECTS SOME *K* FIXTURES AS WELL. | | | | | | 4) NOTE: PLEASE CORRELATE ALL CIRCUITING ON PLANS AND | | | PANEL SCHEDULES. THIS AFFECT THE LIGHTING CONTROLS AS | | | WELL. FOR SOME EXAMPLES PLEASE SEE THE FOLLOWING. | | | PLEASE SEE ROOM 11H06 WHICH CONTAINS *K* FIXTURES, | | | THESE ARE SHOWN CIRCUITED IN TWO LOCATIONS AND BOTH | | | SHOW THE SAME CIRCUIT P2102-28. THIS CIRCUIT AS SHOWN | | | IN THE PANEL P2102 IS FOR ROOM 11D03 WATER DISPENSER. | | | PLEASE SEE ROOM/AREA RIGHT OUTSIDE OF COPY ROOM 11E03 | | | WHICH CONTAINS CIRCUITING P211-82. NO PANEL P211 COULD | | | BE LOCATED ON PLANS.ONLY TWO PANEL SCHEDULES WHICH | | | CONTAIN SUB-SECTIONS WHICH DO CONTAIN A CIRCUIT/SPACE | | | 82 ARE SHOWN AS SPARES/SPACE WITH NOT INDICATION OF | | | LIGHTING. | | | PLEASE SEE THE OTHER FIXTURES IN THIS AREA WHICH ARE | | | ALSO LABELED WITH THE SAME 82. | | | ** AS MENTION ON PREVIOUS REVIEW AND IN MEETING HELD | | | THESE ARE SOME EXAMPLES. PLEASE GO OVER ALL CIRCUITING | | | AND COORDINATE WITH PANEL SCHEDULES, CONTROLS ETC. | | | 408.4, 240.4, 310.16. | | | FBC 13-415.1.ABC.1.1, .1.2, .1.3 (AS NOTED ABOVE) FBC | | | 106.1.2, 106.3.5.1.2 | | | | | | 5) NOTE: PLEASE SEE THE FP SHEETS WHICH ARE MISSING THE | | | REQUIRED CERTIFICATE OF AUTHORIZATION NUMBER. THE SHEET | | | ATTACHED TO THESE SHEETS MAY NOT BE USED TO TAKE PLACE | | | OF THE REQUIRED INFORMATION ON TITLE BLOCKS OF SIGNED | | | AND SEALED PLANS. THIS INFORMATION MAY BE PRINTED ON | | | SHEETS AND IS BEING GIVEN AS INFORMATION AT THIS TIME. | | | THIS COMMENT IS NOT FOR AHA. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-09-12 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-09-12 |
Time |
09:45 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-09-11 |
Time |
18:17 |
Sent To |
|
|
| Notes |
| 2007-09-12 09:45:13 | 2007-09-12 09:45:13 | | | | | | ** DENIED 2ND REVIEW ** | | | | | | *** PLEASE KNOW THAT AS SOME ITEMS FROM THE PREVIOUS | | | REVIEW WHICH ARE STILL IN NEED OF ADDRESSING. ** PLEASE | | | SEE THERE ARE ALSO SOME NEW COMMENTS, BASED ON CHANGES | | | AND INFORMATION NOW SHOWN ON PLANS. THERE IS ONE NEW | | | COMMENT FOR ITEM MISSED ON PREVIOUS REVIEW. | | | | | | 1) NOTE: PLEASE SEE MISSING PRINTED NAME ON THE | | | ENGINEERING SHEETS FOR THE ENGINEER OF RECORD AS | | | REQUIRED PER FAC 61G15-23.002. | | | PLEASE ALSO SEE THE ENGINEER OF RECORD IS ALSO REQUIRES | | | DATING PLANS WHEN SIGNING WHICH WAS NOT DONE ON ALL | | | SETS. PLEASE ALSO BE SURE ALL LICENSE INFORMATION PER | | | FAC 61G15-23.002, FS 471.025 | | | | | | 2) NOTE: PLEASE SEE IT IS STILL UNCLEAR WHAT FLOOR WORK | | | IS BEING DONE ON. THE ORIGINAL PLANS FOR BASE BUILDING | | | CLEARLY INDICATE THE EXISTING PANELS ON RISER WHICH ARE | | | L410A, P210A M410A ETC ON THE 10TH FLOOR YET THESE | | | PLANS AND TITLE BLOCK CALLS THIS THE 11TH FLOOR. THE | | | PLANS FOR LIGHTING AND POWER CALL FOR THE 11TH FLOOR, | | | YET THE PLANS ALSO CALL FOR THE 10TH FLOOR. THIS IS | | | CONFUSING WHY A 10TH FLOOR WOULD BE CALLED THE 11TH | | | FLOOR AND ALL DESIGNATIONS FOR ROOMS AND AREAS ARE | | | SHOWN WITH 11/ELEVEN DESIGNATIONS IF THIS IS THE 10TH | | | FLOOR. THE BASE BUILDING PLANS CALL THIS SAME FLOOR 10 | | | AND NOT 11? | | | PLEASE CLARIFY | | | FAC 61G1-16.004 | | | FBC 106.1.2, 106.3.5.1.2 | | | | | | 3) NOTE: PLEASE VERIFY THE VERSION OF THE ENERGY | | | CALCULATIONS SUBMITTED. PLEASE SEE POSSIBLE MECHANICAL | | | REVIEW COMMENTS FOR METHOD. | | | PLEASE KNOW IN EITHER CASE THE ENERGY CALCULATIONS AS | | | SUBMITTED DO NOT CORRELATE WITH THE SUBMITTED LIGHTING | | | ON PLANS. THE INPUT DATA REPORT WILL BE ABBREVIATED AS | | | IDR FOR THE REST OF THESE NOTES. | | | PLEASE SEE THERE ARE SEVERAL FIXTURES ON PLANS (OVER | | | 100) WHICH ARE NOT INCLUDED ON THE INPUT DATA REPORT. | | | PLEASE SEE THE PREVIOUS REVIEW NOTES WHICH REQUESTED | | | FOR THE ROOM AND AREA DESIGNATIONS ON PLANS TO BE | | | IDENTIFIED ON THE IDR FOR REVIEW AS THERE WERE MULTIPLE | | | ROOMS AND AREAS WITH THE SAME DESIGNATIONS. THE ONLY | | | WAY TO IDENTIFY A ROOM OR AREA IS TO GO THROUGH THE | | | FIXTURE LEGEND AND COUNT EACH FIXTURE IN A ROOM WHICH | | | MAY OR MAY NOT ADD UP TO THE INFORMATION ON THE IDR. | | | PLEASE SEE THE CONFERENCE ROOM FOR ONE EXAMPLE. THIS IS | | | SHOWN AS CONF ON THE IDR AND THERE ARE MULTIPLE ROOMS | | | OF THE SAME DESIGNATION.IN EITHER CASE PLEASE SEE | | | CONFERENCE ROOMS IDENTIFIED ON PLANS AS 11L09 AND 11L08 | | | BOTH OF WHICH CONTAIN THE SAME AMOUNT AND TYPE OF | | | FIXTURES, YET NEITHER CORRELATE WITH ANY OF THE | | | CONFERENCE ROOMS ON THE IDR FOR THE NUMBER AND TYPE OF | | | FIXTURES. | | | THIS IS ONLY ONE EXAMPLE AS THERE ARE NUMEROUS OTHER | | | ROOMS WHICH THE LIGHTING ON PLANS DOES NOT MATCH WITH | | | THE IDR. | | | PLEASE SEE THERE ARE FIXTURES ON PLANS AND FIXTURE | | | LEGEND WHICH ARE NOT ON THE IDR. EXAMPLE: SEE | | | FIXTURE*J*. THIS IS ONLY ONE AS NOTED AND THERE ARE | | | OTHERS. | | | THE PLANS INDICATE A TOTAL OF 60+/PLUS ROOMS AND AREAS, | | | YET THE IDR ONLY INDICATES 30+/-. WHERE ARE THE OTHER | | | ROOMS, AREAS, LIGHTING FIXTURES ETC.? | | | PLEASE COORDINATED ALL ON PLANS WITH THE INPUT DATA | | | REPORT AND ENERGY CALCULATIONS.13-415.1.A, 13-415.1.B , | | | 13-415.1.C, 13-415.2. | | | FBC 106.3.5.1.2, 106.1.2, ETC | | | | | | 4) NOTE: PLEASE SEE THERE IS STILL NOT ENOUGH | | | INFORMATION SHOWN FOR LIGHTING CONTROLS, DEVICES, | | | SYSTEM ETC. THERE ARE NUMEROUS LOCATIONS WHERE NO | | | CONTROLS FOR LIGHTING COULD BE LOCATED OR FOUND. PLEASE | | | SEE THERE ARE MISSING CONTROLS REQUIRED PER | | | 13-415.1.ABC.1.3. | | | | | | 5) NOTE: PLEASE SEE THE TRANSFORMER LISTED AS T4A HAS | | | OVER CURRENT PROTECTION SET ABOVE PERMITTED MAXIMUM | | | LEVELS PER 450.3. THIS WAS NOT NOTED ON PREVIOUS REVIEW | | | HOWEVER PLEASE CORRECT PER 450.3.MUST MEET NOTE #5 IF | | | EXCEEDING THE MAXIMUM OF 125%, IF THIS IS THE CASE | | | PLEASE PROVIDE THE INFORMATION ON THE TRANSFORMER AS | | | NEEDED. 90.7, 110.3 | | | | | | 6) NOTE: PLEASE VERIFY THE PANEL DP10. IT WAS THE | | | UNDERSTANDING THAT EACH TENANT WOULD CONTAIN A MAIN | | | WHICH WOULD BE ABLE TO TURN OFF ALL POWER TO THEIR | | | SPACE. | | | THIS IS SAME FOR THE BRANCH CIRCUITS COMING FROM OTHER | | | PANELS AND OTHER FLOORS SPECIFICALLY THE CIRCUITING | | | INTO THE TENANT SPACE FOR 277V LIGHTING. IS THERE A | | | DISCONNECT SWITCH OF SOME KIND FOR THE LIGHTING INTO | | | SPACE? | | | PLEASE SEE CONSTRUCTION BOARD OF APPEALS PROPOSED OWNER | | | SET UP FOR EACH TENANT WHICH HAD AN AGREEMENT OF TENANT | | | BEING ABLE TO TURN OFF POWER IN AN EMERGENCY? | | | | | | 7) NOTE: PLEASE CLARIFY THE DP10 WHICH SHOWS A 125AMP | | | MCB FEEDING PANEL L410 WHICH IS A 100AMP RATED PANEL | | | WITH A 100AMP MCB? THIS WAS NOTED ON PREVIOUS REVIEW | | | HOWEVER THE PANEL DESIGNATION HAS CHANGED. | | | FBC 106.1.2 FOR INFORMATION. | | | | | | 8) NOTE: PLEASE SEE THE NEW LOCATION OF THE ELECTRICAL | | | TRANSFORMERS, PANELS AND ELECTRICAL SERVICE EQUIPMENT | | | IS NOW BEING SHOWN IN THE FILE STORAGE ROOM WHICH IS | | | NOT PERMITTED. | | | PLEASE PROVIDE A SAFE, SECURE, RATED LOCATION AS | | | REQUIRED FOR LIFE SAFETY, FIRE HAZARD AND PROPERTY | | | HAZARD. | | | 240.24D, 110.26, 110.27, 408.17 | | | | | | 9) NOTE: PLEASE CLARIFY SOME FIXTURE AND RECEPTACLE | | | LOCATIONS WHICH STILL CONTAIN ALPHA AND NUMERIC | | | DESIGNATIONS HOWEVER IT IS UNCLEAR WHAT THESE ARE? FBC | | | 106.1.2 | | | | | | 10) NOTE: PLEASE COMPLETE CIRCUITING ON PLANS AND | | | CORRELATE WITH THE PANEL SCHEDULES. PLEASE SEE THERE | | | ARE STILL RECEPTACLES ON PLANS WHICH DO NOT CONTAIN ANY | | | CIRCUIT DESIGNATIONS. PLEASE SEE THERE ARE SOME WHICH | | | CONTAIN A NUMERICAL IDENTIFICATION HOWEVER THERE IS NOT | | | PANEL DESIGNATION. THERE ARE AREAS WHICH CONTAIN THE | | | NUMERIC DESIGNATIONS AND CLOSE BY HAS THE SAME CIRCUIT | | | NUMBER WITH OTHER WHICH NOTES TO WHICH PANEL THESE GO | | | TO HOWEVER PLEASE SEE REDLINED PLANS FOR LOCATIONS | | | MISSING. | | | PLEASE SEE SOME ROOMS FOR EXAMPLE: 11J09, 11L08, 11L09, | | | 11J06 FOR A FEW WHICH INDICATE A NUMERICAL DESIGNATIONS | | | YET THE PANEL CIRCUITING LOCATED IN CLOSE PROXIMITY | | | COULD BE FOR TWO DIFFERENT PANELS. PLEASE ALSO SEE TWO | | | RECEPTACLES WITH ONE NUMERICAL CIRCUIT DESIGNATION ROOM | | | 11L09 NORTH WALL. | | | PLEASE SEE ROOM 11J14 WHICH DOES NOT INDICATE ANY | | | RECEPTACLES, YET THE DESIGNATIONS IS OFFICE. A NOTE ON | | | PLAN MENTIONS *TYP* FOR TYPICAL, HOWEVER THIS IS | | | TYPICAL OF WHAT? | | | PLEASE GO OVER ALL CIRCUITING ON PLANS AND BE SURE TO | | | COORDINATE WITH THE PANEL SCHEDULES. | | | 408.4 | | | FBC 106.3.5.1.2 | | | | | | 11) NOTE: PLEASE SEE PANEL SCHEDULE FOR P2102 WHICH | | | SHOWS THIS AS BEING *SECTION #1*. IS THERE ARE SECTION | | | #2? THIS APPEARS TO BE A MISPRINT AS RISER AND PLANS | | | DOES NOT SHOW ANY SECTION #2. | | | FBC 106.1.2 | | | | | | 12) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO | | | REPEAT COMMENTS FOR CODE COMPLIANCE. | | | PLEASE KNOW THAT PLANS MAY BE RETAINED BY THIS OFFICE. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | 2007-09-12 07:03:23 | 2007-09-12 07:03:23 | | | | | | IN PROGRESS | | 2007-09-11 20:07:00 | 2007-09-11 20:07:01 | | | | | | REVIEW TO CONTINUE ON 9/12, NOTES WILL FOLLOW ONCE | | | REVIEW IS COMPLETED. | | 2007-09-11 18:17:48 | 2007-09-11 18:17:48 | | | | | | IN ELEC FOR REVIEW. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-06-05 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-05 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-04 |
Time |
21:14 |
Sent To |
|
|
| Notes |
| 2007-06-05 16:14:02 | ** UNSAT ** | | | | | | *** PLEASE KNOW THAT AS SOME ITEMS ARE NOT SHOWN FOR | | | CODE COMPLIANCE AT THIS TIME OR MISSING FOR REVIEW, | | | THERE MAY BE NEW COMMENTS ON THE FOLLOWING REVIEW NOT | | | YET ABLE TO BE MADE. | | | | | | 1) NOTE:PLEASE SEE THE CODES AS STATED NEED TO BE | | | UPDATED TO CODES ADOPTED BY THE STATE AFTER DECEMBER | | | 8TH, 2006. | | | PLEASE THE ARCHITECTURAL SHEETS INDICATE SOME OLDER | | | CODES AS WELL AS THE ELECTRICAL SHEETS WHICH INDICATE | | | SOME OF THE PREVIOUS CODES. SOME OF THE NOTES ON THE | | | ELECTRICAL SHEETS DO INDICATE THE NEWER ADOPTED CODES. | | | | | | 2004 FBC W/2006 REVISIONS (ARCH AND ELECTRICAL SHEETS) | | | 2005 NFPA?70 (NEC) (ARCH AND ELECTRICAL SHEETS) THE | | | OTHER CODES AS LISTED ARE OK. PLEASE BE SURE TO SEE | | | OTHER TRADES FOR COMMENTS ON ANY CODE ADJUSTMENTS. | | | | | | 2) NOTE: PLEASE SEE MISSING INFORMATION REQUIRED ON THE | | | TITLE BLOCKS FOR THE ARCHITECTURAL FIRM AND ARCHITECT. | | | PLEASE SEE THE FLORIDA ADMINISTRATIVE CODE 61G1-16.004 | | | AND FLORIDA STATUTES 481.219 | | | MISSING CERTIFICATE OF AUTHORIZATION NUMBER FOR FIRM, | | | PRINTED NAME OF ARCHITECT AND PRINTED LICENSE NUMBER. | | | ** PLEASE KNOW THIS IS REQUIRED FOR ALL SHEETS AND FOR | | | ALL TRADES WHETHER OR NOT COMMENT IS MADE BY OTHER | | | TRADES. | | | | | | 3) NOTE: PLEASE SEE THE ARCHITECT DID NOT DATE PLANS | | | WHEN SIGNED AS REQUIRED PER FS 481.221. | | | ** PLEASE KNOW THIS IS REQUIRED FOR ALL SHEETS AND FOR | | | ALL TRADES WHETHER OR NOT COMMENT IS MADE BY OTHER | | | TRADES. | | | | | | 4) NOTE: PLEASE SEE THE PLANS IN SOME NOTES INDICATE | | | WORK FOR *CARLTON FIELDS* WHICH IS WORK BEING DONE FOR | | | ANOTHER TENANT BUILD-OUT ON ANOTHER FLOOR. REDLINED AT | | | LOCATIONS. | | | PLEASE ADJUST. | | | FBC 106.1.2 | | | | | | 5) NOTE: PLEASE SEE THE SUITE/UNIT NUMBER HAS BEEN | | | ISSUED/ASSESSED AS 1100, PLEASE INCLUDE ON PLANS AS | | | THERE WILL BE MORE THAN ONE TENANT ON FLOOR WITH MORE | | | THAN ONE SUITE/UNIT. | | | AFC 61G1-16.004 | | | FBC 106.1.2, 106.3.5.1.2 | | | | | | 6) NOTE: PLEASE SEE THE ADDRESS ON TITLE BLOCKS FOR THE | | | AHA ENGINEERING FIRM DOES NOT COORDINATE WITH THAT AS | | | LISTED WITH THE FLORIDA DEPARTMENT OF BUSINESS AND | | | PROFESSIONAL REGULATION. | | | ** THE ADDRESS OF THE SATELLITE OFFICE IS OK, HOWEVER | | | PLEASE LIST THE PRIMARY HOME OFFICE AS LICENSED. | | | | | | 7) NOTE: PLEASE KNOW THAT ALL LOW VOLTAGE SCOPE OF WORK | | | WILL BE UNDER SEPARATE PERMITS. THE PHONE, CATV, ACCESS | | | CONTROL SYSTEM ETC. PERMITS FOR OTHER THAN SECURITY CAN | | | REFERENCE BACK TO THESE PLANS FOR PERMIT HOWEVER THE | | | VALUE AND PERMIT FEE IS BASED ON THAT SCOPE OF WORK. | | | THE ACCESS CONTROL SYSTEM/SECURITY WILL REQUIRE PLANS | | | AND SUBMITTALS FOR DEVICES FOR ACCESS CONTROL. * PLEASE | | | KNOW THAT THESE DEVICES MAY NOT IMPEDED EGRESS FROM | | | BUILDING IN THE EVENT OF AN EMERGENCY PER LS 101 CODE. | | | | | | 8) NOTE: PLEASE VERIFY THE VERSION OF THE ENERGY | | | CALCULATIONS SUBMITTED AS THE VERSION ADOPTED AS OF | | | DECEMBER 8TH, 2006 IS NOT THAT AS SUBMITTED. (3.0). | | | PLEASE SEE THE CALCULATIONS NEED TO BE SIGNED BY THE | | | OWNER'S AGENT AS STATED ON SHEETS. (CONTRACTOR). PLEASE | | | COORDINATE ALL OF THE TYPES OF FIXTURES, THE NUMBER OF | | | FIXTURES ON THE CALCULATIONS WITH THAT OF THE FIXTURES | | | ON PLANS AND FIXTURE LEGEND. THERE ARE SOME | | | DISCREPANCIES BETWEEN THE THREE. | | | PLEASE LABEL THE ROOMS ON CALCULATIONS AS THE | | | DESIGNATIONS ON PLANS OR TO THE POINT EACH ROOM WHICH | | | CONTAINS THE SAME NAME OR CURRENTLY THE SAME | | | DESCRIPTION FOR MULTIPLE ROOMS CAN BE DIFFERENTIATED. | | | PLEASE SEE FBC CHAPTER 13 2004 W/2006 REVISIONS | | | 13-415.1.AB.1.1, .1.2, 13-415.2, 13-103.1.1.1 ETC. | | | | | | 9) NOTE: PLEASE SEE THE TRANSFORMER LIST WHICH | | | INDICATES 400AMP OCP ON THE PRIMARY SIDE OF THE T8A | | | WHICH DOES NOT MEET 450.3. PLEASE SEE THAT IF THE | | | TRANSFORMER IS NOT GOING TO BE PART OF THIS BUILDING | | | REMOVE OR CORRECT OCP SIZE. | | | | | | 10) NOTE: PLEASE SEE THE TRANSFORMER LEGEND DOES NOT | | | CORRELATE WITH THAT OF THE RATING OF THE TRANSFORMER | | | INDICATED ON DP1. | | | PLEASE COORDINATE AND ADJUST AS NEEDED. | | | FBC 106.1.2 | | | | | | 11) NOTE: PLEASE SEE THE ELECTRICAL ROOM CONTAINS | | | EQUIPMENT WHICH IS NOT LISTED OR SHOWN ON RISER OR | | | PANEL SCHEDULES SUBMITTED, PLEASE COMPLETE. | | | FBC 106.3.5.1.2, 106.1.2 | | | NEC 215.5, 408.4, 310.16, 240.4 ETC | | | | | | 12) NOTE: PLEASE SEE THE RISER INDICATE THE ELECTRICAL | | | ROOM LOCATED ON THE 10TH FLOOR AND THE PLANS INDICATE | | | THIS ON THE SAME FLOOR AS THE TENANT SPACE?? PLEASE | | | CORRELATE. | | | FBC 106.1.2 | | | | | | 13) NOTE: PLEASE SEE THE EMERGENCY LIGHTING AND EXIT | | | LIGHTS DO NOT MEET 700.12F | | | ALSO INDICATES THESE BEING FED FROM THE EMERGENCY PANEL | | | ON THE 11TH FLOOR, HOWEVER THIS BUILD OUT IS FOR THE | | | 11TH FLOOR. AS THE RISER AND PLANS DO NOT MATCH AND THE | | | CIRCUITING IS NOT CORRECT IT IS UNCLEAR WHAT IS BEING | | | DONE. | | | PLEASE ALSO EXPLAIN THE EMERGENCY LIGHTING DETAIL AS | | | INDICATED ON E1.11. | | | | | | 14) NOTE: PLEASE SEE PANEL L411AS THIS IS A 100AMP | | | RATED PANEL WITH 125AMP BREAKER FEEDING THIS PANEL? | | | PLEASE CLARIFY AND EXPLAIN. | | | FBC 106.1.2, | | | NEC 240, 408,ETC | | | | | | 15) NOTE: PLEASE SEE THE CORRIDORS WHICH ARE BEING | | | SHOWN ON THESE PLANS AS EXISTING DO NOT EXISTING UNDER | | | THE BASE BUILDING AND ARE NOT BEING APPLIED FOR UNDER | | | THE BUILD OUT PERMIT. THIS WAS IN THE CONDITION OF | | | ISSUANCE OF MAIN BUILDING PERMIT AND CONTRACTOR ALONG | | | WITH OWNER SAID THIS WORK WOULD BE PERMITTED BEFORE | | | BUILD OUTS; HOWEVER THIS IS NOT THE CASE. | | | PLEASE SEE FBC 106, 104, 105 FOR WORK REQUIRED TO HAVE | | | PERMITS. | | | | | | 16) NOTE: PLEASE CLARIFY SOME FIXTURES WHICH CONTAIN | | | LETTERING OF SOME KIND WHICH COULD NOT LOCATE | | | DESIGNATIONS OR ANY NOTES FOR WHAT SOME OF THESE ARE. | | | FBC 106.1.2, 106.3.5.1.2 | | | | | | 17) NOTE: PLEASE SEE THAT ANY CHANGES ON THE BUILD OUT | | | PLANS NEEDS TO BE INCORPORATED INTO THE BASE BUILDING | | | PLANS. PLEASE COORDINATE FOR LOADS, CALCULATIONS, ETC. | | | FBC 106.1.2 | | | | | | 18) NOTE: PLEASE COMPLETE CIRCUITING ON PLANS AND | | | CORRELATE WITH THE PANEL SCHEDULES. | | | FBC 106.3.5.1.2 | | | | | | 19) NOTE: PLEASE PROVIDE THE MINIMUM LAYOUT FOR ALL FA | | | DEVICES FOR HORNS AND STROBES PER FBC 11-4.28.1,.2 AND | | | .3(4). THE LEVELS ARE INDICATE ON THE SYMBOL LEGEND | | | HOWEVER THE BASE BUILD OUT PLANS ARE REQUIRED TO SHOW | | | THE MINIMUM LOCATIONSFOR FBC COMPLIANCE EVEN IF | | | THOUGH THE FIRE ALARM AND ANY FIRE SPRINKLER PERMITS | | | ARE DONE SEPARATELY AS REQUIRED. | | | FBC 106.3.5.1.2, 106.1.2 | | | | | | 20) NOTE: PLEASE CLARIFY THE ROOM LABELED AS *IT* | | | ROOM.; IF THIS IS INDEED A TRUE IT ROOM AS DEFINED IN | | | THE NEC 645 AND NFPA-75, THEN PLEASE ADJUST PLANS TO | | | MEET THE MINIMUM REQUIREMENTS FOR BUILDING, ELECTRICAL | | | AND ANY MECHANICAL. | | | IF THIS IS NOT A TRUE IT ROOM BY DEFINITIONS, PLEASE | | | REMOVE THIS DESIGNATION FROM PLANS. | | | | | | 21) NOTE: PLEASE SEE NOTES MENTIONS THE MAINSHUNT | | | TRIP RATED SWITCH WILL BE 600AMP RATED YET RISER SHOWS | | | 400AMP. PLEASE CORRELATE. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-06-04 21:14:55 | IN ELEC FOR REVIEW |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2008-02-04 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-02-04 |
Time |
18:54 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-02-04 |
Time |
18:29 |
Sent To |
|
|
| Notes |
| 2008-02-04 18:53:48 | *****PROVISO***** | | | | | | REVISED PLAN SHEET E-1.11 STAMPED, INITIALED, AND | | | DATED.HOWEVER, PLAN SHEETS FP1, FP2, AND FP3 TO BE | | | FIRE STAMPED WHEN THE CERTIFICATE OF AUTHORIZATION | | | ISSUE (SEE ELECTRICAL REVIEW COMMENT 5) IS RECTIFIED. | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-11-06 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-11-06 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-11-06 |
Time |
16:04 |
Sent To |
|
|
| Notes |
| 2007-11-06 16:54:32 | *****PROVISO***** | | | | | | THE COMMENTS TAKEN FROM THE PREVIOUS FIRE PLAN REVIEWS | | | HAVE BEEN ADDRESSED;PLAN SHEETS A00.00 AND E-1.11 | | | WERE STAMPED, INITIALED, AND DATED.HOWEVER, PLAN | | | SHEETS FP1, FP2, AND FP3 TO BE FIRE STAMPED WHEN THE | | | CERTIFICATE OF AUTHORIZATION ISSUE (SEE ELECTRICAL | | | REVIEW COMMENT 5) IS RECTIFIED. | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2007-09-18 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-09-18 |
Time |
22:46 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-09-18 |
Time |
21:39 |
Sent To |
|
|
| Notes |
| 2007-09-18 21:42:20 | *****UNSAT***** | | | | | | *:THE FOLLOWING COMMENT TAKEN FROM THE PREVIOUS FIRE | | | PLAN REVIEW STILL NEEDS TO BE ADDRESSED | | | | | | 1.THE COMPLETE ADDRESS, INCLUDING THE SUITE NUMBER, | | | SHALL BE IN THE TITLE BLOCK OF EACH SUBMITTED PLAN | | | SHEET.NO SUITE NUMBER SHOWN SHEETS H-01 THRU P-3.1. | | | | | | *NEW COMMENT: | | | | | | A.CARD READERS(CR) AS SHOWN ON SHEET E-2.11 SHALL NOT | | | BE INCLUDED IN THIS PROJECTED SCOPE OF WORK.PLEASE BE | | | ADVISED THAT SEPARATE PLANS AND PERMIT WILL BE REQUIRED | | | FOR ENTRANCE/EGRESS ACCESS CONTROL SYSTEMS PROVIDED | | | THAT THE CRITERIA AS PER NFPA 101 7.2.1.6.2 ARE MET. | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-07-11 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-07-11 |
Time |
18:55 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-07-11 |
Time |
17:25 |
Sent To |
|
|
| Notes |
| 2007-07-11 18:54:29 | *****DENIED***** | | | | | | | | | 1.THE COMPLETE ADDRESS, INCLUDING THE SUITE NUMBER, | | | SHALL BE IN THE TITLS BLOCK OF EACH SUBMITTED PLAN | | | SHEET. | | | | | | 2.STRUTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 3.PLEASE SPECIFY THE WALL AND CEILING FINISH | | | MATERIALS IN TERMS OF CLASS A, CLASS B, OR CLASS C. | | | | | | 4.HOW WILL THE SCOPE OF WORK IMPACT THE EXISTING FIRE | | | ALARM DEVICES?IF SO, SEPARATE PLANS AND PERMIT ARE | | | REQUIRED FOR THE FIRE ALARM REMODEL. | | | | | | 5.HOW WILL THE SCOPE OF WORK IMPACT THE EXISTING FIRE | | | SPRINKLER SYSTEM?IF SO, SEPARATE PLANS AND PERMIT | | | WILL BE REQUIRED FOR THE FIRE SPRINKLER REMODEL. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING WHERE ON THE PLAN EACH ITEM WAS | | | ACKNOWLEDGED/ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2008-06-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-17 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-17 |
Time |
16:41 |
Sent To |
E |
|
| Notes |
| 2008-06-17 16:41:16 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2008-06-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-06 |
Time |
11:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-06 |
Time |
11:09 |
Sent To |
E |
|
| Notes |
| 2008-06-06 11:09:46 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-05-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-14 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-14 |
Time |
13:03 |
Sent To |
|
|
| Notes |
| 2008-05-14 13:03:18 | TO "COMM" BD#52 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-02-21 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-21 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-21 |
Time |
12:15 |
Sent To |
M |
|
| Notes |
| 2008-02-21 12:15:55 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-01-11 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2008-01-11 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2008-01-11 |
Time |
17:30 |
Sent To |
|
|
| Notes |
| 2008-01-11 17:30:26 | TO COMM BOARD # 16 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-11-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-16 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-16 |
Time |
14:14 |
Sent To |
E |
|
| Notes |
| 2007-11-16 14:14:59 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-10-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-30 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-30 |
Time |
09:54 |
Sent To |
|
|
| Notes |
| 2007-10-30 09:58:23 | TO "COMM" BD#52--PLANS ON RACK/2 ROLLS--EXPEDITED-- |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-08-13 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-13 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-13 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2007-09-10 16:55:11 | TO "COMM" BD#63--EXPEDITED | | 2007-08-13 13:39:58 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-07-11 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-07-11 |
Time |
17:25 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-05-02 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2007-05-10 09:00:37 | TO "COMM" BD#38 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
6 |
Status |
P |
Date |
2008-06-06 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-06-06 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-06-06 |
Time |
15:37 |
Sent To |
PC |
|
| Notes |
| 2008-06-06 15:38:36 | PAGE H-0.1 REVISION 13. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2008-05-29 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-05-29 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-05-29 |
Time |
16:22 |
Sent To |
E |
|
| Notes |
| 2008-05-29 16:54:06 | PG H1.11 REVISION 14. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-04-09 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-04-09 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-04-09 |
Time |
11:15 |
Sent To |
PC |
|
| Notes |
| 2008-04-09 11:44:51 | REVISION 11 PG H1-11. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-11-03 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-11-03 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-11-03 |
Time |
15:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-09-17 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-09-17 |
Time |
15:57 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-09-17 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2007-09-17 15:57:33 | REVIEW #: 2 | | | ACTION: DENIED | | | | | | FBC 2004 CODE FAMILY W/ 2005 AND 2006 SUPPLEMENTS FBC | | | CH.1 AS AMENDED BY THE CITY OF WEST PALM BEACH | | | | | | THE FOLLOWING COMMENTS ARE NUMBERED TO CORRESPOND WITH | | | PREVIOUS REVIEW COMMENTS AS WELL AS DESIGNER'S WRITTEN | | | RESPONSES FOR THE PURPOSE OF CONTINUITY. | | | | | | 1. OK | | | | | | 2. OK | | | | | | 3. THE TAG FOR THE FAN HAS BEEN CHANGED. HOWEVER, THE | | | FAN IS STILL LISTED AS AN "EXHAUST FAN" ON PG H-0.1. | | | PLEASE CORRECT. | | | | | | 4. THE 1415 CFM REQUIRED FOR THIS SPACE IS 56.6% OF THE | | | VOLUME OF OUTDOOR AIR SUPPLIED BY THE BASE BUILDING | | | HVAC SYSTEM. HOW DOES THIS COMPARE TO THE PERCENTAGE OF | | | OCCUPIABLE FLOOR AREA USED BY THIS TENANT? HOW MUCH IS | | | LEFT AFTER REQUIREMENTS ARE MET FOR COMMON AREAS SUCH | | | AS CORIDORS, ELEVATOR LOBBIES AND GANG BATHROOMS? | | | | | | 5. THE INPUT DATA FOR THE EXTERIOR WALLS SHOULD NOT BE | | | CHANGED TO A NEW, HIGHER VALUE, AS THE 4" INSULATION IS | | | ONLY BEING INSTALLED ABOVE THE CEILING IN THE PLENUM | | | AREAS AND NOT ON EXTERIOR WALLS FROM FLOOR TO CEILING. | | | ALSO, DETAIL 9 ON A012.01 DOES NOT SHOW AN APPROVED AIR | | | BARRIER (1/2 INCH GYPSUM WALL BOARD, TAPED AND SEALED | | | OR UL 181 DUCT, TAPED AND SEALED) AS REQUIRED BY FBC | | | 13-410.1.ABC.3.6, 410.1.ABC.3.7, 410.1.ABC.3.3.7.1. SEE | | | ALSO FBC,M 603.8, 603.9, 603.9.1. | | | | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J. REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-06-02 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-06-02 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-06-02 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2007-06-02 14:02:23 | -----------------DENIED----------------- | | | | | | FBC 2004 CODE FAMILY W/ 2006 REVISIONS | | | FBC 2004 CH.1 AS AMENDED BY THE CITY OF WEST PALM | | | BEACH | | | | | | 1.PLEASE VERIFY VALUES ON FPT SCHEDULE. EXAMPLES: A) | | | FPT-11-1 HAS A 12" ROUND INLET, BUT PLAN SHOWS IT BEING | | | FED BY A 16" ROUND DUCT. | | | B) FPT-11-3 MAX FAN CFM AS SHOWN IS OUTSIDE THE CFM | | | RANGE FOR A TITUS DTQS 2-8. | | | C) FPT-11-4 IS SHOWN ON PLANS SUPPLYING 740 CFM, BUT | | | SHCEDULE SHOWS MAX FAN CFM AT 680. | | | PLEASE CLARIFY ALL DISCREPENCIES IN THIS SCHEDULE AND | | | CORRELATE WITH FLOOR PLAN. EQUIPMENT AND APPLIANCES | | | SHALL BE INSTALLED IN ACCORDANCE WITH THEIR LISTING AND | | | MANUFACTURER'S INSTALLATION INSTRUCTIONS PER FBC,M | | | 304.1. | | | | | | 2. I.T. ROOM 11J05: PLAN SHOWS ALL SUPPLY AIR BEING | | | RECIRCULATED TO PLENUM SPACE BY EF-11-1 THROUGH AN | | | EXHAUST GRILL LOCATED IN THE CEILING. WHAT IS THE | | | PURPOSE OF THE TWO 24X24 LAY-IN RETURN GRILLS IN THE | | | CEILING? | | | | | | 3. EF-11-1 DISCHARGES INDOORS. THEREFORE IT IS NOT AN | | | EXHAUST FAN. PLEASE CHANGE THE DESIGNATION OF THIS FAN | | | SO AS NOT TO BE IN CONFLICT WITH FBC,M 501.2. | | | | | | 4. PLEASE PROVIDE OUTDOOR AIR CALCULATIONS TO SHOW | | | COMPLIANCE WITH FBC,M 403.2. | | | | | | 5. EXTERIOR WALLS EXPOSED TO CEILING PLENUM ARE TO BE | | | INSULATED TO A MINIMUM VALUE OF R-8 AND LINED WITH AN | | | APPROVED AIR BARRIER PER FBC 13-410.1.ABC.3.6. ALSO SEE | | | 410.1.ABC.2.2 AND 410.1.ABC.3.7. THE AIR BARRIER | | | PROVISIONS ALSO APPLY TO INTERIOR WALLS BETWEEN | | | CONDITIONED AND UNCONDITIONED SPACES. | | | NOTE: ENERGY CALCULATIONS SHOW EXTERIOR WALLS ARE | | | CURRENTLY INSULATED TO A VALUE OF R-4.8. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT: | | | RONALD J REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2008-02-07 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-02-07 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-02-07 |
Time |
08:44 |
Sent To |
|
|
| Notes |
| 2008-02-07 08:45:48 | REVISION OK--SHTS P-0.1 & P-1.11 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-11-03 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-11-03 |
Time |
17:58 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-11-03 |
Time |
17:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-09-20 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-09-20 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-09-19 |
Time |
07:44 |
Sent To |
|
|
| Notes |
| 2007-09-20 09:19:22 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | 1. OK | | | 2. OK | | | | | | 3. SHT A011.01 DETAIL SHOW COMPLIANCE WITH THE | | | FOLLOWING: | | | A. OK | | | B. 11-4.24.4 SINK DEPTH | | | ****RESPONSE NOTED, BUT THE ENCLOSED CUT SHEETS HAVE | | | NOT BEEN FOUND WITH THE COMMENT RESPONSES. | | | C. 11-4.24.5 CLEAR FLOOR SPACE (FORWARD APPROACH | | | REQUIRED MAX 19" UNDERNEATH THE SINK. - CABINET DOORS | | | ARE NOT ALLOWED.) | | | ****RESPONSE NOTED, BUT THE CABINET DOORS ARE NOT | | | APPROVED IN THE CLEAR FLOOR SPACE PER THE BUILDING | | | OFFICIAL. THE DOORS CREATE ANOTHER OBSTRUCTION AND | | | DECREASES THE ACCESSIBILITY FOR THE USER. THE | | | DEFINITION OF CLEAR FLOOR SPACE REQUIRES AN | | | UNOBSTRUCTED FLOOR OR GROUND SPACE. PLEASE DELETE THE | | | CABINET DOORS AT THE SINKS. | | | D. OK | | | E. 11-4.24.7 FAUCETS | | | ****RESPONSE NOTED, BUT THE ENCLOSED CUT SHEETS HAVE | | | NOT BEEN FOUND WITH THE COMMENT RESPONSES. | | | | | | 4. THE SINK IN ROOM 11JO6 SHALL BE ACCESSIBLE. SUBMIT A | | | DETAIL SHOWING COMPLIANCE WITH SECTION 11-4.24 AND ALL | | | SUBSECTIONS. (SEE COMMENT 3). | | | ****RESPONSE NOTED. (SEE COMMENT 3). | | | | | | 5. OK | | | 5. OK | | | 6. OK | | | 7. OK | | | 8. OK | | | | | | **********NEW COMMENTS********** | | | | | | 1B. THE INPUT DATA REPORT FOR THE WATER HEATERS DOES | | | NOT REFLECT WHAT IS BEING INSTALLED PER THE PLANS. | | | PLEASE CORRELATE INPUT DATA WITH INSTALLATION INDICATED | | | ON THE PLANS. FBC-2004 BUILDING SECTION 13-103. | | | | | | 2B. SHT P-O.1 ELECTRIC WATER HEATER SCHEDULE ONLY | | | INDICATES ONE WATER HEATER IN THE BREAK ROOM. DETAILS | | | INDICATE TWO WATER HEATERS. PLEASE UPDATE SCHEDULE TO | | | REFLECT ALL WATER HEATERS. SECTION 106.1.1. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID | | | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY | | | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-06-09 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-06-09 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-06-09 |
Time |
17:33 |
Sent To |
|
|
| Notes |
| 2007-06-09 17:53:26 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. ALL ARCHITECTURAL SHEETS SHALL INCLUDE THE FOLLOWING | | | INFORMATION IN THE TITLE BLOCK AS REQUIRED BY FAC | | | 61G1-16.004(2)(5)(6) & FA 481.219, 481.2055. THE FIRM | | | LICENSE NUMBER, (CERTIFICATE OF AUTHORIZATION), THE | | | PRINTED NAME OF THE PERSON SEALING THE DOCUMENTS, AND | | | THE DATE THAT THE SIGNATURE AND SEAL ARE AFFIXED SHALL | | | BE INDICATED BELOW THE SIGNATURE. | | | | | | 2. ALL ARCHITECTURAL SHEETS. THE ADDRESS ON FILE WITH | | | THE STATE DBPR WEBSITE DOES NOT REFLECT THE ADDRESS | | | INDICATED IN THE TITLE BLOCK. PLEASE UPDATE THE DBPR | | | WEBSITE OR THE TITLE BLOCKS PRIOR TO RESUBMITTING. FAC | | | 61G1-16.004(1) & FS 481.2055. (SEE ATTACHED SHEET). | | | | | | 3. SHT A011.01 DETAIL SHOW COMPLIANCE WITH THE | | | FOLLOWING: | | | A. 11-4.24.3 KNEE CLEARANCE | | | B. 11-4.24.4 SINK DEPTH | | | C. 11-4.24.5 CLEAR FLOOR SPACE (FORWARD APPROACH | | | REQUIRED MAX 19" UNDERNEATH THE SINK. - CABINET DOORS | | | ARE NOT ALLOWED.) | | | D. 11-4.24.6 EXPOSED PIPES & SURFACES | | | E. 11-4.24.7 FAUCETS | | | | | | 4. THE SINK IN ROOM 11JO6 SHALL BE ACCESSIBLE. SUBMIT A | | | DETAIL SHOWING COMPLIANCE WITH SECTION 11-4.24 AND ALL | | | SUBSECTIONS. (SEE COMMENT 2). | | | | | | 5. SHT P-0.1 DOMESTIC WATER RISER. WATER HAMMER | | | ARRESTORS SHALL BE INDICATED AT ALL QUICK CLOSING | | | VALVES, (ICE MAKERS & DISH WASHERS). SECTION 604.9. | | | WATER HAMMER ARRESTORS SHALL BE LOCATED NEAR THE | | | FIXTURES, IN AN "EFFECTIVE RANGE" NOT IN THE CEILING. | | | PDI-WH 201 AND MANUF. INSTALLATION INSTRUCTIONS. PLEASE | | | SHOW ON THE WATER RISER DIAGRAM. | | | | | | 5. SHT P-0.1 SANITARY RISER DIAGRAM. THE ISLAND VENTS | | | SHALL BE INSTALLED PER FIGURE 913.2. (SEE ATTACHED | | | SHEET). | | | | | | 6. SHT P-0.1 DETAILS 1, 2 & 3 PER SECTION 504.6.1 A | | | VISIBLE AIR GAP OR AIR GAP FITTING IN THE SAME ROOM IS | | | REQUIRED. UNDER THE COUNTER IS NOT CONSIDERED VISIBLE. | | | PLEASE SHOW COMPLIANCE.--(PER CONVERSATION WITH | | | CHRIS HENSON THE INDIRECT WASTE WILL BE VISIBLE WHEN | | | CABINET DOOR IS OPEN) 6-29-7 | | | | | | 7. SHT P-0.1 THE SANITARY RISER DIAGRAM INDICATES | | | GARBAGE DISPOSALS UNDER THE SINKS. ADA APPROVED OFFSET | | | GARBAGE DISPOSALS SHALL BE REQUIRED TO KEEP THEM OUT OF | | | THE CLEAR FLOOR SPACE REQUIRED FOR THE FIXTURE. PLEASE | | | INDICATE THIS REQUIREMENT ON THE PLAN. | | | | | | 8. SHT P-0.1 WATER FILTERS SHALL MEET THE REQUIREMENT | | | OF NSF 42. PLEASE SUBMIT MANUF. SPECIFICATIONS FOR THE | | | FILTERS SHOWING COMPLIANCE. SECTION 611.1. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID | | | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY | | | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|