| Plan Review Stops For Permit 07050038 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2007-06-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-06-13 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-06-13 |
Time |
15:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-06-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-06-25 |
Time |
07:07 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-06-25 |
Time |
06:48 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-05-21 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-05-21 |
Time |
10:51 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2007-05-21 |
Time |
10:44 |
Sent To |
G |
|
| Notes |
| 2007-05-21 10:51:22 | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW | | | | | | 1} THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST | | | PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC. | | | | | | 2} INDICATE ON THE PANEL SCHEDULE (GENERATOR CALC'S) | | | SHEET'S, THAT IT IS THE SCHEDULE FOR THE TRANSFER | | | SWITCH. | | | | | | 3} INDICATE CONDUIT SIZE AND TYPE, AND NUMBER OF | | | CONDUCTORS FOR THE RUN TO THE TRANSFER SWITCH FROM THE | | | EXISTING PANEL. | | | | | | NOTE: 702.8 A SIGN SHALL BE PLACED AT THE | | | SERVICE-ENTRANCE EQUIPMENT THAT INDICATES THE TYPE AND | | | LOCATION OF ON-SITE OPTIONAL STANDBY POWER SOURCES. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2007-07-02 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-07-02 |
Time |
13:56 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-07-02 |
Time |
13:56 |
Sent To |
M |
|
| Notes |
| 2007-07-02 13:58:38 | ****************PROVISO**************** | | | A) FBC-2004 FUEL GAS SEC. 404.12 OUTLET | | | CLOSURES: GAS OUTLETS THAT DO NOT CON- | | | NECT TO APPLIANCES SHALL BE CAPPED GAS | | | TIGHT. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2007-05-24 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-05-24 |
Time |
14:08 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2007-05-24 |
Time |
14:08 |
Sent To |
B |
|
| Notes |
| 2007-05-24 14:23:44 | DENIED | | | REFERENCE: | | | ** FBC-2004 FUEL GAS. | | | ** THE CITY OF WEST PALM BEACH GAS PERMIT APPLICATION | | | REQUIREMENTS. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | GAS PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. ONE OF THE SUBMITTED SURVEYS OF THE PROPOSED WORK | | | IS IN PENCIL. PLANS SUBMITTED IN PENCIL ARE | | | UNACCEPTABLE. PLEASE CORRECT. | | | | | | 2.A GAS PERMIT CAN NOT BE ISSUED UNTIL | | | A GEN/RES PERMIT APPLICATION HAS BEEN | | | APPLIED FOR AND APPROVED BY ZONING FOR | | | THE GENERATOR LOCATION. | | | | | | 3. PLEASE SUBMIT MANUFACTRER SPECIFICATIONS OF | | | PROPOSED 2 PSI TO 0.5 PSI MP REGULATORS INDICATING THE | | | MANUFACTURER'S NAME, MODEL NUMBER, MAXIMUM LOAD | | | CAPACITY AND SHOW A LISTING FROM A NATIONALLY | | | RECOGNIZED TESTING LABORATORY (NRTL). | | | | | | 4. NOTE: A MP REGULATOR IS REQUIRED AND MUST BE | | | INSTALLED FOR THE PROPOSED FUTURE BBQ. PLEASE INDICATE | | | THE REGULATOR ON THE RESUBMITTAL. | | | | | | 5. FBC-2004 CHAPTER 1,SECTION 106.3.4.2: | | | THE PERSON RESPONSIBLE FOR THE DESIGN OF | | | THE DRAWING SHALL CLEARLY PRINT AND SIGN | | | NAME, AND ALSO DATE DRAWING. PLEASE DO | | | THIS PRIOR TO RESUBMITTING. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-06-19 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-19 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-19 |
Time |
16:11 |
Sent To |
Z |
|
| Notes |
| 2007-06-19 16:11:24 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-05-07 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-07 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-07 |
Time |
16:40 |
Sent To |
E |
|
| Notes |
| 2007-05-07 16:40:59 | TO "GEN-RES" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-06-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-06-13 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-05-03 |
Time |
11:35 |
Sent To |
|
|
| Notes |
| 2007-05-03 11:35:21 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2007-07-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-03 |
Time |
08:44 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-07-03 |
Time |
08:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-05-08 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-05-08 |
Time |
07:56 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2007-05-08 |
Time |
07:56 |
Sent To |
E |
|
| Notes |
| 2007-05-08 08:06:36 | *** DENIED *** | | | 1) INFORMATION WRITTEN ON SURVEY MAY NOT BE DONE IN | | | PENCIL, PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-06-20 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-06-20 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-06-20 |
Time |
14:37 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-05-04 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-05-04 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-05-04 |
Time |
15:42 |
Sent To |
I |
|
| Notes |
| 2007-05-04 15:43:17 | ***FAILED*** | | | | | | | | | 1) PLEASE PROVIDE DISTANCE FROM REAR PROPERTY LINE TO | | | PROPOSED GENERATOR ON BOTH COPIES OF SURVEY. | | | | | | | | | CHRIS HOOPS | | | ZONING TECHNICIAN | | | 561-805-6720 |
|
|