| Plan Review Stops For Permit 07040976 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-06-11 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-06-11 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-06-06 |
Time |
16:24 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2007-05-09 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-05-09 |
Time |
14:49 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-05-09 |
Time |
12:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2007-05-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-05-08 |
Time |
15:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-05-08 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2007-05-08 15:32:11 | REVIEWED FOR NEW RECEPT BRANCH CIRCUIT ONLY. | | | EXISTING SERVICE RISER NOT INLCUDED IN SCOPE OF WORK. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-06-08 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-06-08 |
Time |
17:38 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-06-08 |
Time |
17:21 |
Sent To |
|
|
| Notes |
| 2007-06-08 17:38:22 | *****APPROVED***** | | | | | | | | | ALL COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | | BEEN ADDRESSED;PLAN SHEETS A-6.1, E-1, AND FP-1 WERE | | | STAMPED, INITIALED, AND DATED. | | | | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-05-14 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-05-14 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-05-14 |
Time |
11:26 |
Sent To |
|
|
| Notes |
| 2007-05-14 11:46:09 | *****DENIED***** | | | | | | | | | 1.THE 2003 EDITION OF NFPA 101 - LIFE SAFETY CODE - | | | SHALL BE REFERENCED. | | | | | | 2.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 3.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL | | | BE REMOVED FROM THE SITE DAILY OR MORE FREQUENTLY AS | | | NECESSARY FOR SAFE OPERATION. | | | | | | 4.THE DEMOLITION OF EXISTING AND/OR THE STOCKING OF | | | NEW BUILDING MATERIALS & SUPPLIES SHALL NOT INTERFERE | | | OR HINDER ACCESS TO OR EGRESS FROM THE SAID FLOOR OR | | | THE BUILING. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH COMMENT WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-05-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-22 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-22 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2007-06-01 08:47:00 | TO "BOB"#9 | | 2007-05-22 11:23:13 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-05-14 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-05-14 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-05-02 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2007-05-02 15:43:23 | TO "BOB"#13 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2007-06-01 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-06-01 |
Time |
11:59 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-06-01 |
Time |
11:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-05-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-05-03 |
Time |
09:06 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-05-03 |
Time |
09:06 |
Sent To |
|
|
| Notes |
| 2007-05-03 09:10:28 | *** DENIED *** | | | 1) MECHANICAL PLANS SHOW EXISTING OPEN OFFICE #803 HAS | | | 1,200 CFM'S. OF SUPPLY AIR AND ONLY 600 CFM'S. OF | | | RETURN AIR, SEE 2004 FBC/M 601.4 BALANCED RETURN AIR, | | | PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|