| Plan Review Stops For Permit 07040908 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2008-07-21 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2008-07-21 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2008-07-18 |
Time |
16:57 |
Sent To |
|
|
| Notes |
| 2008-07-21 09:21:37 | #2 FROM PREVIOUS REVIEW, IMPACT FEES ARE STILL | | | REQUIRED. | | | | | | #3, COMPLIED | | | | | | #4, COMPLIED | | | | | | #5 COMPLIED | | | | | | #6 COMPLIED | | | | | | | | | | | | | | | THANK YOU, | | | LUIS MARTINEZ | | | 561-805-6710 | | 2008-07-18 17:10:22 | REVISION COMMENTS | | | | | | | | | #1 FROM PREVIOUS REVIEW RESPONCE IS NOT APPROVED. | | | PANDULA'S OFFICE SHALL SUBMIT FORMAL NOTORIZED LETTER | | | TAKING FULL RESPONSIBILITY FROM PRINCIPLE DESIGN AND | | | DEVELOPMENT |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2008-06-09 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2008-06-09 |
Time |
12:37 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2008-06-09 |
Time |
10:13 |
Sent To |
Z |
|
| Notes |
| 2008-06-09 12:37:03 | BUILDING REVISION COMMENTS | | | | | | | | | | | | | | | 1) | | | PROVIDE CERTIFIED LETTER FROM NEW DESIGNERS (ARCHITECTS | | | AND ENGINEERS) TAKING RESPONSIBILITY FOR THE ORIGINAL | | | DESIGNERS WORK. | | | | | | 2) | | | SUBMIT PLANS TO PALM BEACH COUNTY IMPACT FEE OFFICE | | | FOR REVIEW AND PROVIDE COPY OF RECEIPT. | | | | | | 3) | | | DOES THIS REVISION INCLUDE THE BREAKFAST ROOM, KITCHEN | | | OR BOTH. | | | | | | 4) | | | SHEET A-3, EXPLAIN NEW 2-STORY ADDITION, NEW BALUSTERS | | | AND RE-BUILDING THE CORNICES NOTES. | | | | | | 5) | | | PROVIDE FINISH FLOOR ELEVATION, MINIMUM ELEVATION | | | REQUIRED IS 7.5 FOR A-5 FLOOD ZONE. | | | | | | 6) | | | IDENTIFY DOOR SCHEDULE PAGE, A__ WHAT ? | | | | | | | | | | | | | | | | | | LUIS MARTINEZ | | | 561-805-6710 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2008-04-28 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2008-04-28 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2008-04-28 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2008-04-28 13:26:42 | REVISION FOR ENERGY CALCULATIONS | | | | | | | | | | | | | | | CANNOT REVIEW FOR ENERGY CALCULATIONS WITHOUT FIRST | | | OBTAINING A MECHANICAL PERMIT FOR THE INSTALLATION OF | | | YOUR SYSTEM. | | | | | | | | | | | | | | | | | | L.MARTINEZ | | | 805-6710 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2007-05-17 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-05-17 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-05-17 |
Time |
14:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2008-06-27 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-06-27 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-06-27 |
Time |
13:40 |
Sent To |
M |
|
| Notes |
| 2008-06-27 13:40:20 | ** DENIED REVISION ** | | | | | | ** ELECTRICAL RISER HAS NOW BEEN COMPLETELY REVISED | | | ONCE AGAIN. | | | ** PLANS ARE COMING BACK FOR COMMENTS FROM OTHER | | | TRADES. | | | | | | ** GENERATOR IS NOT PART OF THE ELECTRICAL REVIEW. | | | NIC. | | | | | | 1) NOTE: RISER SHOWS NEW ATS ON THE LINE SIDE OF THE | | | MDP WHICH IS OK, HOWEVER THE SPECS SUBMITTED ARE NOT | | | FOR A SERVICE ENTRANCE RATED TRANSFER SWITCH. | | | 230.70,230.76,230.76, 110.3, 90.7 | | | FBC 106.1.1, 106.1.2 FOR COORDINATION, CLARITY AND | | | ADDITIONAL INFORMATION. | | | | | | 2) NOTE: PLEASE SEE RISER SHOWS MDP AS MLO (MAIN LUG | | | ONLY) YET THEMDP ON PANEL SCHEDULE SHOWS THIS | | | CONTAINING A MAIN. | | | 230.70, 408.4, )225.31-225.39 | | | FBC 106.1.1, 106.1.2 FOR CLARITY, ADDITIONAL | | | INFORMATION AND COORDINATION OF PLANS. | | | | | | 3) NOTE: PLEASE SEE NEW STEAM GENERATOR WHICH IS SHOWN | | | AS A 6KW LOAD ON A 1-POLE 20AMP CIRCUIT. | | | PLEASE ADJUST. | | | 310.16, 240.4 ETC | | | | | | 4) NOTE: PLEASE EXPLAIN NEW SHEET E-3.1 WHICH SHOWS | | | SEVERAL NEW DETAILS FOR THIS PROJECT. PLEASE KNOW IF | | | THESE DETAILS INCLUDING NEW GROUND BAR IS GOING TO BE | | | USED THIS WOULD BE DIFFERENT FROM THE RISER GROUNDING | | | ELECTRODE SYSTEM. | | | THIS WOULD ALSO REQUIRE OTHER GROUNDING ELECTRODE | | | METHODS. ARE ALL DETAILS ON THIS SHEET INTENDED? | | | PLEASE COORDINATE. | | | 250.50 | | | FBC 106.1.1 FOR CLARITY. | | | | | | ONCE AGAINIF THERE ARE ANY QUESTIONS OR COMMENTS | | | PLEASE CALL. | | | | | | ** IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2008-06-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-06-03 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-06-03 |
Time |
10:53 |
Sent To |
B |
|
| Notes |
| 2008-06-03 10:54:06 | ** DENIED 2ND REVIEW ** | | | | | | ** PLEASE SEE SOME COMMENTS FROM PREVIOUS REVIEWS ARE | | | STILL IN NEED OF ADDRESSING. | | | | | | | | | 1) NOTE: AS THE ORIGINAL PERMIT APPLIED AS 06040626 DID | | | NOT CONTAIN SUB PERMITS, INSPECTIONS FOR MEP AND DID | | | NOT OBTAIN FINAL INSPECTIONS, PLANS MUST GO BACK TO | | | ZONING FOR REVIEW AND STAMPING. THERE ARE SOME ITEMS ON | | | PLANS CHANGED WHICH WERE NOT ON ORIGINAL PLANS STAMPED | | | BY ZONING. | | | ALL REVISED PLANS MUST ALSO CONTAIN HISTORIC REVIEW AND | | | STAMPS. PLANS WILL BE ROUTED TO ZONING. | | | | | | 2) NOTE: AS STATED ON PREVIOUS REVIEW THE GENERATOR WAS | | | NOT INCLUDED ON ORIGINAL PLANS AND NEEDS TO BE DONE | | | UNDER A SEPARATE PERMIT. THE ATS MAY BE INCLUDED WITH | | | ELECTRICAL SERVICE HOWEVER PLEASE SEE THE ATS MUST MEET | | | THE FOLLOWING. | | | PLEASE SEE THE SIZE IS STILL SHOWN AS 260AMPS WHICH IS | | | NOT A STANDARD RECOGNIZED IN THE NEC 240.6. | | | 110.3, 90.7. | | | | | | 3) NOTE: PLEASE KNOW DISCONNECTING MEANS PER | | | 225.31-225.39 SHALL BE INSTALLED. BASED ON PLANS THERE | | | IS NO DISCONNECTING MEANS FOR FEEDERS FROM GENERATOR AT | | | MAIN HOUSE. | | | PLEASE KNOW AS SHOWN THIS DOES NOT APPEAR TO MEET THE | | | EXCEPTION IN 702.11. | | | THIS ONLY NEEDS TO BE A DISCONNECT RATED FOR LOAD | | | SERVED AND NOT A DISCONNECT WITH OVER CURRENT | | | PROTECTION. | | | | | | 4) NOTE: PLEASE SEE ALL RECEPTACLES SERVING KITCHEN | | | COUNTER SPACE ARE REQUIRED TO BE GFI/GFI PROTECTED PER | | | 210.8A6. THIS WOULD INCLUDE KITCHEN ISLAND. THIS CAN BE | | | REDLINED IF ONLY COMMENT REMAINING OR IF PAGE DOES NOT | | | NEED TO BE REVISED FOR ANY OTHER COMMENTS. | | | | | | 5) NOTE: PLEASE SEE ELECTRICAL RISER IS SHOWING AN | | | *EQUIPMENT GROUNDING CONDUCTOR* BEFORE THE FIRST MEANS | | | OF DISCONNECT AND BEFORE FPL METER WHICH IS NOT | | | PERMITTED. | | | PLEASE SEE 250.6, 250.24 | | | ** EQUIPMENT GROUNDING CONDUCTORS ARE ONLY INSTALLED | | | AFTER THE FIRST MEANS OF DISCONNECT. | | | | | | 6) NOTE: PLEASE SEE 210.52B1, 210.11C1, 220.52 AS | | | 1500VA SHALL BE FIGURE FOR EACH OF THE SMALL APPLIANCE | | | CIRCUITS. | | | THERE ARE A GREATER NUMBER OF SMALL APPLIANCE CIRCUITS | | | ON PANEL SCHEDULES THAN SHOWN ON LOAD CALCULATIONS. | | | | | | 7) NOTE: PLEASE SEE 408.4 AS THE PANEL SCHEDULE SHALL | | | BE DETAILED FOR CIRCUITS IN WHICH THEY FEED. THIS WILL | | | AFFECT THE NOTE #6 ABOVE AS CIRCUIT #1 IS ACTUALLY A | | | REFRIGERATOR. | | | PLEASE SEE THE FOLLOWING TEXT EXTRACTED FROM THE NEC. | | | SECTION 408.4 WAS REVISED FOR THE 2005 CODE TO REQUIRE | | | THAT THE IDENTIFICATION FOR EVERY CIRCUIT SUPPLIED BY A | | | PANEL-BOARD OR SWITCHBOARD BE LEGIBLE AND CLEARLY STATE | | | THE SPECIFIC PURPOSE FOR WHICH THE CIRCUIT IS USED. | | | CIRCUITS USED FOR THE SAME PURPOSE MUST BE IDENTIFIED | | | AS TO THEIR LOCATION. FOR EXAMPLE, SMALL APPLIANCE | | | BRANCH CIRCUITS CAN SUPPLY OUTLETS IN THE KITCHEN, | | | DINING ROOM, AND KITCHEN COUNTERTOPS. IDENTIFYING THE | | | CIRCUITS AS SMALL APPLIANCE BRANCH CIRCUITS IS NOT | | | ACCEPTABLE; INSTEAD, THEY SHOULD BE IDENTIFIED AS | | | ``KITCHEN WALL RECEPTACLES,'' ``DINING ROOM FLOOR | | | RECEPTACLE,'' OR ``KITCHEN COUNTERTOP RECEPTACLES LEFT | | | OF SINK.'' CIRCUIT DIRECTORIES CONTAINING MULTIPLE | | | ENTRIES WITH ONLY ``LIGHTS'' OR ``OUTLETS'' DO NOT | | | PROVIDE THE SUFFICIENT DETAIL REQUIRED BY THIS | | | SECTION. | | | | | | 8) NOTE: PLEASE SUBMIT THE LOAD CALCULATIONS ON EACH | | | PANEL. PANELS ARE SHOWN AS 400AMP AND NOW SERVICE WHICH | | | WAS PREVIOUSLY 400AMPS IS NOW 250AMPS. HOWEVER FEEDERS | | | ARE STILL SHOWN FOR 400AMPS? | | | EACH PANEL NOTES TO SEE LOAD CALCULATIONS FOR LOADS ON | | | PANELS HOWEVER BASED ON THE LOADS SHOWN ON SHEET ONLY | | | THE LOAD FOR ENTIRE SERVICE IS SHOWN. | | | PLEASE SUBMIT AND COORDINATE. | | | 220, 215.5, 310.16, 240.4 ETC | | | FBC 106.1.2 FOR COORDINATION AND ADDITIONAL | | | INFORMATION. | | | | | | 9) NOTE: PLEASE SEE THE PANEL *A* SHOWS A AHU/CU #3, | | | HOWEVER SO DOES PANEL *B*. | | | PLANS SHOW FOUR SYSTEMS. | | | PLEASE SEE PLANS ON E-1.1 AS BOTH THE CU#1 AND CU#4 ARE | | | SHOWN ON SAME CIRCUITS A-33/35. THIS IS NOT POSSIBLE. | | | PLEASE COORDINATE. 408.4 | | | FBC 106.1.2 | | | | | | 10) NOTE: PLEASE SEE ELEVATOR SHOWS A 10KW LOAD ON A | | | 30AMP CIRCUIT. THIS CAN NOT BE POSSIBLE AS 10KW EXCEEDS | | | THE RATING OF THE 30AMP CIRCUIT. | | | 310.16, 240.4 ETC | | | PLEASE VERIFY LOAD ON ELEVATOR. | | | | | | 11) NOTE: PLEASE SEE 110.26 AS NOT ALL THE CU | | | DISCONNECT MEET MINIMUM CLEARANCES. | | | | | | 12) NOTE: PLEASE KNOW *GATES* ARE NOT INCLUDED IN SCOPE | | | OF WORK. | | | | | | 13) NOTE: PLEASE SEE AS NOTED ABOVE IN NOTE#9 PLEASE | | | COORDINATE ALL CIRCUITING ON PLANS WITH THAT OF THE | | | CIRCUITS ON PANEL SCHEDULES. | | | FBC 106.3.5.4, 106.1.2, NEC 408.4. | | | THE FEW NOTED ABOVE IS NOT AN EXHAUSTED LIST AND ONLY | | | REFERENCE A FEW FOR EXAMPLES. | | | | | | 14) NOTE: PLEASE KNOW AS NOTED IN PREVIOUS REVIEW THE | | | LOCATIONS OF THE FIXTURES IN CLOSETS DO NOT APPEAR TO | | | MEET 410.8 WITH THE MINIMUM SHELVING DISTANCES GIVEN BY | | | THE CODE. THE PLANS NOTE ON WALL ABOVE DOOR OR ON | | | CEILINGS.THERE MAY BE THE MINIMUM NEEDED PER CODE FOR | | | LOCATIONS ABOVE DOOR HOWEVER THE LOCATIONS ON CEILINGS | | | FOR SOME OF THESE DO NOT APPEAR THIS WILL MEET CODE. | | | THE PLANS ALSO CALL FOR THE FIXTURE TO BE CHOSEN BY | | | OWNER/ARCHITECT HOWEVER THE MINIMUM SHALL BE SHOWN ON | | | PLANS AT THIS TIME FOR THE TYPE OF FIXTURES TO COMPLY | | | WITH MINIMUM SAFETY AND FIRE CONCERNS. | | | THIS IS A FIRE/ LIFE SAFETY HAZARD AND ONE REASON MANY | | | FIRES ARE STARTED IN CLOSETS AND STORAGE AREAS WHICH | | | EASILY IGNITABLE MATERIALS ARE LOCATED. | | | | | | ** IMPORTANT** | | | ONCE AUDIT/REVIEWS ARE COMPLETE AND PLANS ARE PICKED UP | | | FOR CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE | | | ALL OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. | | | DO NOT LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE AUDIT/REVIEW PROCESS AND AVOID | | | ANY DELAYS. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. IF | | | THERE ARE ANY QUESTIONS OR COMMENTS PLEASE DO NOT | | | HESITATE IN CONTACTING THIS OFFICE. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2008-04-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-04-04 |
Time |
17:32 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-04-04 |
Time |
17:32 |
Sent To |
PC |
|
| Notes |
| 2008-04-04 17:32:25 | ** DENIED ** | | | | | | 1) NOTE: PLEASE SEE THAT COMPLETE PLANS INCLUDING PLANS | | | FOR SITE AND SURVEY WILL BE REQUIRED TO BE SUBMITTED. | | | NO GENERATOR WAS ON ORIGINAL PLANS WHICH ARE NOW | | | CLOSED. | | | PLEASE SEE THAT THE SUBMITTED PLANS FOR *STRUCTURAL | | | ONLY SCOPE OF WORK* NEEDS TO INCLUDE ALL WORK WHICH DID | | | NOT RECEIVE FINALS UNDER ORIGINAL APPLIED PERMIT | | | 06040626. THIS WILL INCLUDE THE ADDITION TO THE | | | EXISTING DWELLING UNDER FIRE DAMAGE REPAIR ETC. | | | THE NEW GENERATOR/ATS WAS NEVER PERMITTED OR APPLIED | | | FOR. | | | | | | ** THERE WAS NEVER ANY ROUGH ELECTRICAL INSPECTION ON | | | THE PREVIOUS ELECTRICAL PERMIT WHICH HAS EXPIRED. | | | | | | 2) NOTE: PLEASE SEE THE VALUE FOR THE COMPLETE SCOPE OF | | | WORK WHICH IS NOW BEING INCLUDED TO PREVIOUS APPLIED | | | SCOPE OF WORK NOT COMPLETED NEEDS TO BE ADJUSTED. | | | THE VALUE FOR ALL LABOR, MATERIALS EQUIPMENT ETC NEEDS | | | TO BE INCLUDED. IF THE GENERATOR IS GOING TO BE UNDER | | | THE SCOPE OF WORK THEN PLEASE KNOW VALUE SHALL INCLUDE | | | THIS AS APPLIED VALUE. | | | FBC 108.3 | | | | | | 3) NOTE: PLEASE SEE THAT SOME ITEMS WHICH ARE SHOWN AS | | | EXISTING ON PLANS NEEDS TO BE SHOWN AS NEW AS THESE | | | RECORD SET OF PLANS IS TO COMPLETE SCOPE OF WORK NEVER | | | COMPLETED. THE NEW CONTRACTOR AND RECORD PLANS NEEDS TO | | | SHOWS THESE. | | | FOR EXAMPLE: | | | OFFICE, ADDITION, ETC | | | FBC 106.3.5.4 | | | | | | 4) NOTE: PLEASE SEE THERE ARE SEVERAL LIGHT FIXTURES | | | MISSING FOR ROOMS AND OUTDOOR LOCATIONS WHICH NEED | | | FIXTURES PER 210.70, LS 101 7.8. | | | MOST ARE SHOWN AS J-BOXES. | | | | | | 5) NOTE: PLEASE SEE THE LOAD CALCULATIONS STATE A | | | 250AMP SERVICE YET RISER SHOWS 400AMPS. | | | FBC 106.1.2 FOR COORDINATION. | | | | | | 6) NOTE: PLEASE VERIFY HOW SOME OF THE AHU/CU ON PANEL | | | SCHEDULES HAVE NO LOADS SHOWN. | | | FOR EXAMPLE: | | | UNITS #2 AND 3. | | | 220 | | | | | | 7) NOTE: PLEASE SUBMIT MANUFACTURES SPECS/CUT SHEETS ON | | | GENERATOR AND ATS. | | | PLEASE SEE 110.3, 90.7 | | | SLAB DETAILS NEEDED BY BUILDING. | | | PLEASE ALSO KNOW THE HOUSE/LOCATION IS IN A FLOOD ZONE, | | | ALL ELECTRICAL EQUIPMENT INCLUDING GENERATOR MUST BE | | | 6INCHES ABOVE BASE FLOOD ELEVATION. | | | | | | 8) NOTE: PLEASE COMPLETE CIRCUITING FOR SMOKE ALARMS. | | | PLEASE ALSO SEE NFPA-72 11.8.3 AS THE SMOKE ALARM IN | | | MASTER BEDROOM IS NOT CODE COMPLIANT. NEEDS TO BE | | | WITHIN 3FT OFPEAK AND WITHIN 12INCHES OF THE HIGHEST | | | POINT. | | | | | | 9) NOTE: PLEASE SEE FBC 13-606.1.ABC.1.2.4 FOR MINIMUM | | | TYPES OF RECESSED LIGHTS. | | | | | | 10) NOTE: PLEASE SEE LIGHTS IN SOME CLOSETS DO NOT MEET | | | 410.8 FOR MINIMUM CLEARANCES. | | | | | | 11) NOTE: PLEASE SEE THE FEEDER SIZE SHOWN FROM THE | | | GENERATOR IS SHOWN AS 150MCM. THIS IS NOT A CONDUCTOR | | | SIZE PER AWG. | | | 110.3 | | | | | | 12) NOTE: CODES NEED TO BE STATED ON PLANS. | | | 2005 NFPA-70 | | | 2003 NFPA-101 | | | 2002 NFPA-72 | | | 2004 FBC W/ 2007 (RESIDENTIAL CODE) | | | | | | 13) NOTE: PLEASE SEE THE ELECTRICAL AND CONDUITS RUN | | | OUTSIDE THE PROPERTY IN THE CITY RIGHT OF WAY ARE NOT | | | PERMITTED. | | | ALL ELECTRICAL MUST REMAIN WITHIN LOT LINES. | | | | | | 14) NOTE: PLEASE COMPLETE FIXTURE LEGEND, AND SYMBOL | | | LEGEND FOR THIS DWELLING. PLEASE SEE SHEET E-0.1 WHICH | | | INDICATES MANY ITEMS FROM WHAT WOULD BE A COMMERCIAL | | | BUILDING INCLUDING FIXTURES AND CONTROLS. | | | FBC 106.3.5.4, 106.1.2 | | | | | | | | | ** PLEASE KNOW AS THERE ARE SOME ITEMS NOT YET | | | SUBMITTED FOR REVIEW A FULL REVIEW COULD NOT BE DONE AT | | | THIS TIME. | | | | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2008-07-01 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-07-01 |
Time |
09:29 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-07-01 |
Time |
09:29 |
Sent To |
B |
|
| Notes |
| 2008-07-01 10:01:47 | GAS PLAN REVIEW: | | | REVISION DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | 1. SHEET P-2.1 NATURAL GAS RISER DIAGRAM: | | | SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE SECTION 401.1 SCOPE. | | | NOTE: THE SUBMITTED GAS ISOMETRIC IS NOT INDICATING | | | THE CORRESPONG LENGTHS TO ALL CUT SECTIONS OF PIPE. | | | REFERENCE THE RED CIRCLED YELLOW HIGH LIGTHED AREAS | | | INDICATING THIS AND COMPLY. | | | | | | 2. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | NOTE: REFERENCE COMMENT #1 AND CORRELATE THE "GAS | | | SIZING BASED ON THE FOLLOWING" TABLE TO REFLECT THE | | | CORRECT "MAXIMUM DEVELOPED LENGTH". THE ADDED SUM FROM | | | THE METER TO THE FARTHEST APPLIANCE IS 101'. THE PLANS | | | ARE INDICATING 98' WHICH IS INCORRECT. UNTIL COMMENT #1 | | | IS ADDRESSED AND PLANS CORRELATED GAS WILL CONTINUE TO | | | FAIL PLAN REVIEW. THE UNDERGROUND PE PIPING TO THE | | | GENERATOR IS UNDERSIZED. THE FBC- FUEL GAS TABLE | | | 402.4(20) FOR 1-1/2" PE @ 125' IS ONLY GOOD FOR 550,000 | | | BTU'S, HOWEVER THE PLANS ARE INDICATING A BTU LOAD | | | CAPACITY FOR THE GENERATOR AS BEING 1,012,000 BTU'S. | | | THE FBC- FUEL GAS TABLE 402.4(20) @ 125' ONLY GOES UP | | | TO 2" PIPE WHICH IS ONLY GOOD FOR 871,000 BTU'S. PLEASE | | | REFERENCE THE ATTACHED GAS TABLES INDICATING THIS. | | | PLEASE PROVIDE A SIZING TABLE INDICATING COMPLIANCE OR | | | CHANGE SYSTEM TO A 2 PSI DELIVERY PRESSURE. | | | | | | 3. SHEET P-1.1 AND P-2.1 PLEASE CORRELATE GENERATOR | | | WITH ELECTRICAL SHEETS E-21 AND E-3.1 AND INDICATE THE | | | GENERATOR A "FUTURE" APPLIANCE. NOTE: GENERATOR IS | | | UNDER A SEPERATE PERMIT. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2008-05-30 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-05-30 |
Time |
08:19 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-05-30 |
Time |
08:19 |
Sent To |
E |
|
| Notes |
| 2008-05-30 10:02:31 | GAS PLAN REVIEW: | | | DENIED REVISION: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | GAS PLAN REVIEW TO MEET CODE COMPLIANCE. | | | NOTE: A GAS PERMIT WILL BE REQUIRED FOR THE PROPOSED | | | WORK. | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE SECTION 401.1 SCOPE. | | | NOTE: THE SUBMITTED NATURAL GAS RISER DIAGRAM ON SHEET | | | P-2.1 IS NOT AN ISOMETRIC AND IT DOES NOT CLEARLY | | | INDICATE ALL CUT SECTIONS OF PIPE WITH CORRESPONDING | | | LENGTHS. | | | | | | 2. SHEET P-1.1 FIRST FLOOR PLAN INDICATES THE GAS | | | WATER HEATER IN A CONFINED SPACE WITH THE DRYER. SUBMIT | | | CALCULATIONS FOR COMBUSTION | | | AIR AND MAKEUP AIR PER FBC-2004 FUEL GAS CODE SECTION | | | 304. | | | | | | 3. NOTE: A RESIDENTIAL GENERATOR PERMIT IS REQUIRED | | | FOR THE GENERATOR. THE LOCATION OF THE GENERATOR NEEDS | | | TO APPROVED BY ZONING BEFORE A GAS PERMIT CAN BE | | | ISSUED. SUBMIT TWO COPIES OF A SITE PLAN OR SURVEY | | | CLEARLY INDICATING THE GENERATOR'S LOCATION AND | | | DIMENSIONS FROM PROPERTY LINES AND DISTANCES FROM | | | ADJACENT STRUCTURES. | | | | | | 4. SHEET P-2.1 GAS ISOMETRIC THE BTU'S FOR THE | | | GENERATOR ARE WRONG. PER THE SUBMITED MANUFACTURER'S | | | SPECIFICATIONS THE GENERATOR @ 100% STANBY RATING IS | | | 790,000. PLEASE CORRECT BOTH THE BTU'S INDICATED FOR | | | THE GENERATOR AND THE TOTAL BTU'S FOR THE SYSTEM TO | | | 1,160,000. | | | | | | 5. PER (W.P.B. AS AMENDED) SECTION 106.1 SUBMITTAL | | | DOCUMENTS. CONSTRUCTION DOCUMENTS, SPECIAL INSPECTION | | | AND STRUCTURAL OBSERVATION PROGRAMS, AND OTHER DATA | | | SHALL BE SUBMITTED IN TWO OR MORE SETS WITH EACH | | | APPLICATION FOR A PERMIT. | | | NOTE: ONLY ONE COPY OF THE GENERATOR MANUFACTURER'S | | | SPECIFICATIONS WAS SUBMITTED. | | | | | | 6. THE SUBMITTED GENERATOR MANUFACTURER'S | | | SPECIFICATIONS FAIL TO INDICATE GENERATOR'S REQUIRED | | | SETBACKS FROM STRUCTURES. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2008-04-02 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-04-02 |
Time |
09:31 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-04-02 |
Time |
08:33 |
Sent To |
P |
|
| Notes |
| 2008-04-02 09:47:15 | DENIED; | | | 1. TYPE OF GAS, (LP OR NATURAL) | | | 2. SHOW THE DISTANCE FROM THE POINT OF | | | DELIVERY, (METER), TO THE MOST REMOTE | | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | | OF CAPACITY TABLES A.3.1(4). | | | 3. INDICATE THE DELIVERY PRESSURE (PSI) | | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | 4. A GEN-RES. AND A ELECTRICAL PERMIT APPLICATION IS | | | REQUIRED FOR GENERATOR. PROVIDE MANUFACTURE SPEC. | | | SHEETS, ELECTICAL PLAN AND SURVEY. | | | GAS PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2007-04-26 |
|
|
Cont ID |
|
| Sent By |
swurafti |
Date |
2007-04-26 |
Time |
10:51 |
Rev Time |
0.00 |
| Received By |
swurafti |
Date |
2007-04-26 |
Time |
10:51 |
Sent To |
|
|
| Notes |
| 2007-04-26 10:51:58 | HISTORIC APPROVED BY GJUDGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-06-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-06-23 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-06-23 |
Time |
10:44 |
Sent To |
Z |
|
| Notes |
| 2008-06-23 10:44:51 | TO "Z" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-05-16 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-05-16 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-05-16 |
Time |
13:47 |
Sent To |
E |
|
| Notes |
| 2008-05-16 13:47:57 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-04-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-01 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-01 |
Time |
08:46 |
Sent To |
M |
|
| Notes |
| 2008-04-01 08:46:27 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-04-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-01 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-01 |
Time |
08:38 |
Sent To |
E |
|
| Notes |
| 2008-04-01 08:39:17 | TO "DPALMER" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2008-04-01 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-01 |
Time |
08:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-01 |
Time |
08:20 |
Sent To |
P |
|
| Notes |
| 2008-04-01 08:20:57 | TO "P" BOX/REV--PLEASE REFERENCE PERMIT#06040626 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-05-17 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-05-17 |
Time |
14:36 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-05-01 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2007-05-01 14:48:00 | TO "LMARTINEZ" DESK--PLEASE REFERENCE PERMIT#06040626 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-06-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-06-27 |
Time |
14:16 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2008-06-27 |
Time |
14:16 |
Sent To |
P |
|
| Notes |
| 2008-06-27 14:18:55 | HIGH VELOCITY SYSTEM | | | | | | *** PROVISO *** | | | 1) IF PLASTIC REGISTERS, GRILLES OR DIFFUSERS ARE USED | | | THEN PROVIDE UL TESTING REPORT. | | | PER 2004 FBC/R M1601.16 DUCT REGISTERS, GRILLES AND | | | DIFFUSERS SHALL BE INSTALLED IN ACCORDANCE WITH THE | | | MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND SHALL | | | HAVE A FLAME SPREAD RATING NOT OVER 25 WITHOUT EVIDENCE | | | OF CONTINUED PROGRESSIVE COMBUSTION AND A | | | SMOKE-DEVELOPED RATING NOT OVER 50 WHEN TESTED IN | | | ACCORDANCE WITH ASTM E 84. BALANCING DAMPERS OR OTHER | | | MEANS OF SUPPLY AIR ADJUSTMENT SHALL BE PROVIDED IN THE | | | BRANCH DUCTS OR AT EACH INDIVIDUAL DUCT REGISTER, | | | GRILLE OR DIFFUSER. | | | | | | 2) HAVE DETAILED MANUFACTURER'S SPECIFICATION'S AND | | | INSTALLATION INSTRUCTIONS FOR A/C SYSTEM AND | | | PRE-ENGINEERED DUCT SYSTEM ON JOB SITE FOR CITY | | | INSPECTORS. PER 2004 FBC/R M1401.1. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2008-05-21 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-05-21 |
Time |
13:47 |
Rev Time |
1.15 |
| Received By |
tgordon |
Date |
2008-05-21 |
Time |
13:47 |
Sent To |
P |
|
| Notes |
| 2008-05-21 13:48:49 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) AS NOTED IN LAST REVIEW 4-1-08 NOTE #1. ENERGY | | | CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT ALSO, PER | | | 2004 FBC 13-103.3. | | | | | | 2) AS NOTED IN LAST REVIEW 4-1-08 NOTE #6. PLEASE | | | SUBMIT DETAILED MANUFACTURER'S SPECIFICATION'S THAT | | | SHOW THE SUPPLY AIR VENTS COMPLY WITH 2004 FBC M1601.16 | | | REGISTERS, GRILLES AND DIFFUSERS.DUCT REGISTERS, | | | GRILLES AND DIFFUSERS SHALL HAVE A FLAME SPREAD RATING | | | NOT OVER 25 WITHOUT EVIDENCE OF CONTINUED PROGRESSIVE | | | COMBUSTION AND A SMOKE-DEVELOPED RATING NOT OVER 50 | | | WHEN TESTED IN ACCORDANCE WITH ASTM E 84. THE RESPONSE | | | RECEIVED REFERS TO UL94 HB THAT DEALS WITH FLAME | | | RATING, NOT FLAME SPREAD RATING AND SMOKE-DEVELOPED | | | RATING. PLEASE PROVIDE DOCUMENTATION SHOWING THE FLAME | | | SPREAD RATING AND SMOKE-DEVELOPED RATING. | | | | | | 3) NOT NOTED IN LAST REVIEW, THE GAS TANKLESS WATER | | | HEATER IS IN A CONFINED SPACE WITH A CLOTHES DRYER. | | | PLEASE PROVIDE FOR COMBUSTION AND MAKE-UP AIR PER 2004 | | | FBC/R G2407.1, G2407.4, AND G2407.5.1. | | | | | | 4) NOT NOTED IN LAST REVIEW, THE PROPERTY IS IN FLOOD | | | ZONE 'A5' PLEASE SHOW HOW THE A/C CONDENSER UNITS AND | | | GENERATOR WILL BE MAINTAINED 6" ABOVE THE BASE FLOOD | | | ELEVATION, PER W.P.B. CITY ORDINANCE CHAPTER 94, | | | ARTICLE XVII SECTION 94-543. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2008-04-01 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-04-01 |
Time |
14:02 |
Rev Time |
1.30 |
| Received By |
tgordon |
Date |
2008-04-01 |
Time |
14:02 |
Sent To |
B |
|
| Notes |
| 2008-04-01 14:25:38 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2007 REVISIONS, CITY OF WEST PALM | | | BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT | | | ALSO, PER 2004 FBC 13-103.3. | | | | | | 2) COOLING LOAD CALCULATIONS FOR SYSTEM #1 ARE CALLING | | | FOR 23,300 TOTAL COOLING BTU'S, MECHANICAL PLANS ARE | | | SHOWING A SYSTEM WITH 33,000 TOTAL COOLING BTU'S. THE | | | PLANS CAN ONLY CALL FOR 15% MORE THAN THE COOLING LOAD | | | CAL'S, PER 2004 FBC 13-607.1.ABC.1.1. A 3 TON SYSTEM IS | | | TO LARGE PLEASE CORRECT. | | | | | | 3) COOLING LOAD CALCULATIONS FOR SYSTEM #2 ARE CALLING | | | FOR 31,200 TOTAL COOLING BTU'S, MECHANICAL PLANS ARE | | | SHOWING A SYSTEM WITH 44,000 TOTAL COOLING BTU'S. THE | | | PLANS CAN ONLY CALL FOR 15% MORE THAN THE COOLING LOAD | | | CAL'S, PER 2004 FBC 13-607.1.ABC.1.1. A 4 TON SYSTEM IS | | | TO LARGE PLEASE CORRECT. | | | | | | 4) COOLING LOAD CALCULATIONS FOR SYSTEM #3 ARE CALLING | | | FOR 34,300 TOTAL COOLING BTU'S, MECHANICAL PLANS ARE | | | SHOWING A SYSTEM WITH 54,000 TOTAL COOLING BTU'S. THE | | | PLANS CAN ONLY CALL FOR 15% MORE THAN THE COOLING LOAD | | | CAL'S, PER 2004 FBC 13-607.1.ABC.1.1. A 5 TON SYSTEM IS | | | TO LARGE PLEASE CORRECT. | | | | | | 5) PLEASE SUBMIT MANUAL D CALCULATIONS OR EQUIVALENT | | | FOR RESIDENTIAL DUCT DESIGN, PER 2004 FBC/R M1601.1 AND | | | FBC 13-610.1.ABC.1. | | | | | | 6) PLEASE SUBMIT DETAILED MANUFACTURER'S | | | SPECIFICATION'S AND INSTALLATION INSTRUCTIONS FOR THE | | | SUPPLY AIR VENTS TO SHOW THEY COMPLY WITH 2004 FBC | | | M1601.16 REGISTERS, GRILLES AND DIFFUSERS.DUCT | | | REGISTERS, GRILLES AND DIFFUSERS SHALL BE INSTALLED IN | | | ACCORDANCE WITH THE MANUFACTURER?S INSTALLATION | | | INSTRUCTIONS, AND SHALL HAVE A FLAME SPREAD RATING NOT | | | OVER 25 WITHOUT EVIDENCE OF CONTINUED PROGRESSIVE | | | COMBUSTION AND A SMOKE-DEVELOPED RATING NOT OVER 50 | | | WHEN TESTED IN ACCORDANCE WITH ASTM E 84. BALANCING | | | DAMPERS OR OTHER MEANS OF SUPPLY AIR ADJUSTMENT SHALL | | | BE PROVIDED IN THE BRANCH DUCTS OR AT EACH INDIVIDUAL | | | DUCT REGISTER, GRILLE OR DIFFUSER. | | | | | | 7) THE VALUE ON THE PERMIT MUST BE ADJUSTED TO THE FAIR | | | MARKET VALUE (REPLACEMENT VALUE) FOR THE RENOVATION | | | WITH ALL MATERIALS AND LABOR. IF THE VALUE IS NOT | | | ADJUSTED THEN THE CITY WILL NEED TO ADJUST IT USING THE | | | MARSHALL & SWIFT NATIONAL VALUATION SERVICE, PER 2004 | | | WPB AMEND. 108.3. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2008-07-01 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-07-01 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-07-01 |
Time |
08:50 |
Sent To |
G |
|
| Notes |
| 2008-07-01 09:28:18 | PLUMBING PLAN REVIEW: | | | REVISION DENIED: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | 1. SHEET P-1.1 FIRST FLOOR PLAN DOES NOT REFLECT THE | | | FIRST FLOOR PLAN ON SHEET A-1. PLEASE CORRELATE THE | | | FOLLOWING ON SHEET P-1.1 WITH SHEET A-1. PER FBC- | | | PLUMBING SECTIONS 401.1, 601.1 AND 701.1 SCOPE. | | | | | | A} THE 15" PREP SINK AND DISHWASHER IS MISSING AS WELL | | | AS THE SANITARY AND WATER TO THESE FIXTURES. | | | | | | B} THE POT FILLER WATER SUPPLY IS MISSING. | | | | | | C} THE 24" DISHWASHER BY THE 36" SINK IS BEING | | | INDICATED ON THE WRONG SIDE OF THE 36" SINK. | | | | | | 2. SHEET P-2.1 SANITARY RISER DIAGRAM DOES NOT REFLECT | | | THE FIRST FLOOR PLAN ON SHEET A-1. PLEASE CORRELATE THE | | | FOLLOWING ON SHEET P-2.1 WITH SHEET A-1. PER FBC- | | | PLUMBING SECTIONS 701.1 AND 901.1 SCOPE. | | | | | | A} THE SANITARY AND VENT FOR THE 15" PREP SINK IS | | | MISSING AS WELL AS THE DRAIN FOR THE DISHWASHER. | | | | | | B} THE DISHWASHER DRAIN FOR THE 36" SINK IS BEING | | | INDICATED ON THE WRONG SIDE OF THE SINK. | | | | | | 3. SHEET P-2.1 SANITARY RISER DIAGRAM: DELETE THE SH | | | BY THE WC IN THE SECOND FLOOR BATH #3 (THIS IS | | | CONFUSING). PER FBC- PLUMBING SECTION 701.1 SCOPE. | | | | | | 4. SHEET P-2.1 DOMESTIC WATER RISER DIAGRAM DOES NOT | | | REFLECT THE FIRST FLOOR PLAN ON SHEET A-1. PLEASE | | | CORRELATE THE FOLLOWING ON SHEET P-2.1 WITH SHEET A-1. | | | PER FBC- PLUMBING SECTION 601.1 SCOPE. | | | | | | A} THE HOT AND COLD WATER FOR THE 15" PREP SINK AND | | | DISHWASHER IS MISSING. | | | | | | B} THE WATER SUPPLY TO THE POT FILLER IS MISSING. | | | (CLEARLY INDICATE IF ITS HOT OR COLD WATER AS SOME POT | | | FILLERS HAVE BEEN KNOWN TO BE HOT WATER) | | | | | | 5. SHEET P-2.1 DOMESTIC WATER RISER DIAGRAM: THE | | | FOLLOWING FIXTURES NEED WATER-HAMMER ARRESTORS DUE TO | | | HAVING QUICK-CLOSING VALVES. PER FBC-PLUMBING SECTION | | | 604.9. | | | | | | A} THE HOT WATER SUPPLY TO THE DISHWASHER BY THE 36" | | | SINK. | | | | | | B} THE HOT WATER SUPPLY TO THE DISHWASHER BY THE 15" | | | PREP SINK. | | | | | | C} THE HOT AND COLD WATER TO THE WASHING MACHINE. (ADD | | | NOTE BY WASHING MACHINE: REFERENCE DETAIL SHEET | | | P-0.1). | | | | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2008-05-30 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-05-30 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-05-29 |
Time |
16:41 |
Sent To |
G |
|
| Notes |
| 2008-05-29 16:57:08 | PLUMBING PLAN REVIEW: | | | DENIED REVISION: | | | | | | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 2007 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS TO | | | CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. SHEET P-0.1 AUTOMATIC CLOTHES WASHER CONNECTION | | | DETAIL: THE DRAINAGE STACK NEED TO BE 3",PER FBC-2004 | | | PLUMBING SECTION 406.3 WASTE CONNECTION. THE CLEANOUT | | | FOR THE WASHING MACHINE NEEDS TO BE 3". PER FBC-2004 | | | PLUMBING SECTION 708.7 MINIMUM SIZE. | | | | | | 2. SHEET P-2.1 RISER DIAGRAM - SANITARY: THE AUTOMATIC | | | CLOTHES WASHER BRANCH DRAIN AND STACK NEED TO BE 3", | | | PER FBC-204 PLUMBING SECTION 406.3 WASTE CONNECTION. | | | THE CLEANOUT FOR THE WASHING MACHINE NEEDS TO BE 3", | | | PER FBC-2004 PLUMBING SECTION 406.3. | | | | | | 3. SHEET P-2.1 POWDER ROOM #109: THE LAV STACK NEEDS A | | | CLEANOUT AT THE BASE OF ITS STACK DUE TO THE "PLUMBING | | | FIXTURE SCHEDULE" ON SHEET P-0.1 INDICATING 1-1/4" | | | TRAPS FOR THE LAVATORIES. PER FBC-2004 PLUMBING SECTION | | | 708.3.4. | | | | | | 4. ENERGY CALCULATIONS NEED TO BE SIGNED BY | | | OWNER/AGENT. PER FBC-2004 13-103.3. | | | | | | ********IMPORTANT INFORMATION******** | | | WHEN RESUBMITTING PLANS, PLEASE PROVIDE A COPY OF THE | | | OLD PLANS, CLEARLY INDICATE THE REVISION ON THE NEW | | | PLANS, REMOVE AND REPLACE ANY PAGES AS NECESSARY. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | PHONE= (561) 805-6730 | | | FAX= (561) 805-6731 | | | E-MAIL= [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2008-04-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2008-04-03 |
Time |
08:57 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2008-04-03 |
Time |
08:48 |
Sent To |
|
|
| Notes |
| 2008-04-03 09:02:48 | DENIED; | | | 1. SEE MECHANICAL PLAN REVIEW NOTE # 7. VALUE $ OF WORK | | | AND MATERIALS IS TO LOW. | | | 2. PLUMBING AND GAS APPLICATIONS ARE REQUIRED. | | | 3. SHOW ALL PLUMBING AND GAS APPLIANCES ON FLOOR PLANS, | | | SHEETS ,A-1 AND A-1.1. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2008-06-24 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-06-24 |
Time |
14:17 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-06-24 |
Time |
14:17 |
Sent To |
E |
|
| Notes |
| 2008-06-24 14:18:22 | ***FAILED - ZONING 2ND REVIEW*** | | | | | | | | | REPEAT COMMENTS: | | | | | | 2)DEMOLITION/ADDITION PLANS SHALL BE STAMPED AND | | | APPROVED BY THE CITY'S HISTORIC PRESERVATION | | | DEPARTMENT. | | | | | | 5)PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDRS): AS THE VALUE OF | | | THE PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE | | | (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY | | | APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE | | | WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF | | | THE ZLDRS.PLEASE SUBMIT A LANDSCAPE PLAN SHOWING | | | COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF THE | | | ZLDRS. | | | | | | 6)ELECTRICAL SITE PLAN (SHEET ES -1) SHOWS A | | | GENERATOR.INDICATE SETBACK DIMENSIONS FROM PROPOSED | | | GENERATOR EQUIPMENT TO ALL PROPERTY LINES.AS PER | | | SECTION 94-305(B)(4) OF THE CITY'S ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDRS): MECHANICAL EQUIPMENT | | | MAY NOT PROJECT MORE THAN 4 FEET INTO A REQUIRED | | | SETBACK.NOTE: THE GENERATOR MUST MAINTAIN A MINIMUM | | | SETBACK OF 11 FEET TO THE REAR (WEST) PROPERTY LINE. | | | | | | | | | NEW COMMENT: | | | | | | 1)THE SIDE SETBACK IS NOT CLEARLY SHOWN FROM THE | | | PROPERTY LINE TO THE NEW ADDITION.INDICATE THIS | | | SETBACK DIMENSION ON THE SITE PLAN. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 | | | [email protected] | | | | | | | | | | | | | | | SENT TO "E" - DP |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2008-06-09 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2008-06-09 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2008-06-09 |
Time |
14:56 |
Sent To |
|
|
| Notes |
| 2008-06-09 15:14:52 | ***FAILED - ZONING 1ST REVIEW*** | | | | | | | | | 1)PROVIDE TWO (2) COPIES OF A CURRENT SURVEY, WHICH | | | INCLUDES THE PROPERTY'S LEGAL DESCRIPTION AND ADDRESS. | | | | | | 2)DEMOLITION/ADDITION PLANS SHALL BE STAMPED AND | | | APPROVED BY THE CITY'S HISTORIC PRESERVATION | | | DEPARTMENT. | | | | | | 3)INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C | | | EQUIPMENT TO ALL PROPERTY LINES.AS PER SECTION | | | 94-305(B)(4) OF THE CITY'S ZONING AND LAND DEVELOPMENT | | | REGULATIONS (ZLDRS): MECHANICAL EQUIPMENT MAY NOT | | | PROJECT MORE THAN 4 FEET INTO A REQUIRED SETBACK. | | | | | | 4)INDICATE OVERHANG DIMENSIONS OF THE PROPOSED | | | ADDITION.AS PER SECTION 94-305(B) OF THE ZLDRS: | | | OVERHANGS MAY NOT PROJECT MORE THAN 3' INTO A REQUIRED | | | SETACK. | | | | | | 5)PURSUANT TO SECTION 94-441(C)(2) OF THE ZONING AND | | | LAND DEVELOPMENT REGULATIONS (ZLDRS): AS THE VALUE OF | | | THE PROPOSED WORK EXCEEDS 50% OF THE STRUCTURE'S VALUE | | | (LISTED AS "IMPROVEMENT VALUE" WITH THE P.B.C. PROPERTY | | | APPRAISER'S OFFICE), LANDSCAPING SHALL BE IN COMPLIANCE | | | WITH ALL APPLICABLE REGULATIONS FOUND IN ARTICLE XIV OF | | | THE ZLDRS.PLEASE SUBMIT A LANDSCAPE PLAN SHOWING | | | COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF THE | | | ZLDRS. | | | | | | 6)ELECTRICAL SITE PLAN (SHEET ES -1) SHOWS A | | | GENERATOR.INDICATE SETBACK DIMENSIONS FROM PROPOSED | | | GENERATOR EQUIPMENT TO ALL PROPERTY LINES.AS PER | | | SECTION 94-305(B)(4) OF THE CITY'S ZONING AND LAND | | | DEVELOPMENT REGULATIONS (ZLDRS): MECHANICAL EQUIPMENT | | | MAY NOT PROJECT MORE THAN 4 FEET INTO A REQUIRED | | | SETBACK.NOTE: THE GENERATOR MUST MAINTAIN A MINIMUM | | | SETBACK OF 11 FEET TO THE REAR (WEST) PROPERTY LINE. | | | | | | | | | NOTE:THE "FUTURE LIBRARY CONSTRUCTION - TO BE | | | PERMITTED SEPARATELY" WILL NOT BE ALLOWED AS SHOWN. IF | | | THE PRINCIPAL STRUCTURE IS MADE TO CONNECT TO THE | | | EXISTING ACCESSORY STRUCTURE, THE ENTIRE BUILDING WILL | | | BE REQUIRED TO MEET THE PRINCIPAL STRUCTURE'S SETBACK | | | REQUIREMENTS, WHICH IT DOES NOT. | | | | | | | | | QUESTIONS/COMMENTS, CONTACT CHRIS HOOPS, | | | ZONING TECHNICIAN (561)805-6720 |
|
|