Plan Review Details - Permit 07040738
Plan Review Stops For Permit 07040738
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-08-21 Cont ID  
Sent By amorse Date 2007-08-21 Time 16:16 Rev Time 0.00
Received By amorse Date 2007-08-21 Time 16:16 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-08-10 Cont ID  
Sent By amorse Date 2007-08-10 Time 18:49 Rev Time 0.00
Received By amorse Date 2007-08-10 Time 18:48 Sent To PC
Notes
2007-08-10 19:15:26 
  
 DENIED
  
 1)MAKE CORRECTIONS TO DRAWINGS TO MATCH ENERGY
 CALC'S, IF TAKING A CREDIT FOR R11 FOR RAISED SLAB
 PLEASE SHOW THE INSULATION ON THE DRAWINGS. WALL
 DETAILS SHOW NO FINISH FOR 2ND FLOOR CEILING/SLAB.
  
 2)STAIR DETAILS DO NOT PROVIDE CORRECT INFORMATION,
 RISE 7" AND RUN 11" CANNOT WORK. PLEASE SEE THAT FIN.
 FL. ELEVATION SHOULD MATCH ALL OTHER DETAILS (SHOWS
 10'-0" NOT 10'-4" AS OTHER DETAILS SHOW, DIVIDED
 EQUALLY THEIR ARE 18 RISERS AT 6 7/8" +/-AND 17
 TREADS AT 11 OR 11 1/4" SO TOTAL RUN WOULD BE 15'-11
 1/4" IF 11 1/4" TREADS WERE USED.)
  
 3)METAL ROOFING SHINGLES OR PANELS CANNOT BE APPLIED
 TO SLOPES LESS THAN 3/12 PER R905.4.2 AND R905.10.2 FBC
 RES
  
 4)THE FOLLOWING PRODUCT APPROVALS REQUIRE
 CORRECTIONS:
  
 A) THE MIAMI-DADE REPORT FOR CASTCRETE LINTELS IS FOR
 4,6 & 12 INCH WIDE BLOCK THE CORRECT REPORT FOR 8" IS
 REQUIRED 03-0605.05, ALSO BE SURE TO SUBMIT THE ENTIRE
 REPORT AS ONLY ONE PAGE OF THE INCORRECT REPORT WAS
 SUBMITTED.
  
 B) THE JELD-WEN DOOR PRODUCT APPROVAL HAS BEEN REVISED
 FOR THE 2004 CODE CYCLE FL# 539-R2 WITH NEW MIAMI- DADE
 REPORT # 07-0314.05
  
 C) THE PRODUCT APPROVAL FOR THE TRACO TR 9100 WINDOWS
 ARE ONLY RATED AS SMALL MISSILE IMPACT, ALL OPENINGS
 WITHIN 30 FEET OF GRADE ARE REQUIRED TO BE LARGE
 MISSILE IMPACT RATED.
  
 5)PER 713.13(2) F.S. IF THE IMPROVEMENT DESCRIBED IN
 THE NOC HAS NOT COMMENCED WITHIN 90 DAYS OF RECORDING
 THE NOTICE IS VOID PLEASE HAVE NOC RERECORDED
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-06-19 Cont ID  
Sent By amorse Date 2007-06-19 Time 17:33 Rev Time 0.00
Received By amorse Date 2007-06-19 Time 17:33 Sent To PC
Notes
2007-06-19 18:25:25 
  
 DENIED
  
 1)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*
  
 2)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON
 SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER
 ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE
 ADDED TO THE PERMIT APPLICATION FEES
  
 NOTE TOTAL FEES DUE FOR INCREASED VALUE AND RADON ARE $
 64.70.
  
 3)A DESIGN PROFESSIONAL THAT IS REGISTERED TO
 PRACTICE UNDER CHAPTER 481 OR 471 OF
 THE FLORIDA STATUTES SHALL AFFIX THEIR OFFICIAL SEAL,
 SIGNATURE AND DATE TO SAID DRAWINGS AND SPECIFICATIONS
 PER 106.1 FBC 2004. THE EXEMPTION FROM LICENSURE UNDER
 481.229 FS DOES NOT EXEMPT THE DESIGNER RESPONSIBLE FOR
 THE DRAWINGS FROM SIGNING AND DATING SAID DRAWINGS.
  
 4)SUBMIT 2 COPIES OF ENGINEERED TRUSS DRAWINGS THAT
 COMPLY WITH R802.10.1 FBC WITH PERMIT APPLICATION OR
 BEFORE INSTALLATION THAT HAVE BEEN REVIEWED AND
 APPROVED BY THE DESIGNER OF RECORD
  
 5)SUBMIT TWO COPIES OF ENERGY CALC'S PER 13-101.2.2
 FBC. BE SURE THAT THEY ARE SIGNED AND
 DATED BY PREPARER AND OWNER/AGENT PRIOR
 TO SUBMITTAL
  
 6)PROVIDE A SITE PLAN THAT SHOWS DRAINAGE IN
 COMPLIANCE WITH THE REQUIREMENTS OF R403.1 FBC RES.
  
 7)PROVIDE SCHEDULE FOR PRE CAST LINTEL THAT WILL BE
 USED AND OPENING SIZES TO COMPLY WITH 2104.1.5 FBC
  
 8)PROVIDE STAIR CONSTRUCTION REQUIREMENTS, RISE, RUN
 TOTAL HEIGHT, ETC. PER 106.3.5 FBC
  
 9)PROVIDE ALL DOOR AND WINDOW DESIGN PRESSURES
  
 10)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES
 OF EACH PRODUCT APPROVAL THAT
 IS RELEVANT PER 9B-72. THESE SHOULD INCLUDE THE FLORIDA
 STATE APPROVAL COVER PAGES, AND THE PRODUCT NOA THAT
 LISTS THE SYSTEM COMPONENTS/ FASTENER LIST PAGES, THE
 PAGES WITH THE CHOSEN ASSEMBLY/ SYSTEM TO BE USED AND
 THE GENERAL LIMITATIONS PAGE. ALL CAN BE FOUND ON
 WWW.FLORIDABUILDING.ORGPLEASE NOTE THAT PRODUCT
 APPROVALS MUST BE UP TO DATE
  
 11)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA
 STATE PRODUCT APPROVAL COVER
 SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON
 WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT
 SUBMITTED APPLICATIONS WILL BE DENIED
  
 12)PROVIDE PRODUCT APPROVALS FOR THE DOUBLE DOORS
 (FRENCH?) , METAL ENTRY DOOR,MODIFIED ROOFING
 MATERIAL (BE SURE TO PICK THE CORRECT SYSTEM FROM THE
 NOA AND CALCULATE THE ENHANCED FASTENING THAT WILL BE
 REQUIRED FOR THE EDGE AND CORNER ZONES) AND ROOFING
 TILES
  
 13) CLARIFY WHAT WILL BE USED FOR ROOF TILE THE
 DRAWINGS SPECIFY CERAMIC TILES AND THE PRODUCT APPROVAL
 SUBMITTED IS FOR METAL DECRA TILES
  
 14)THE GARAGE DOOR PRODUCT APPROVAL DOES NOT MEET THE
 DESIGN PRESSURE THAT IS REQUIRED
  
 THE FOLLOWING INFORMATION IS REQUIRED FOR
 CLARIFICATION:
  
 15)THE 2ND FLOOR PLAN SHOWS 4" SLAB AND THE WALL
 SECTIONS ON AS-4 AND AS-5 SHOW 6"
  
 16)BREEZEWAYHEIGHT ON A/3 NORTH ELEVATION SHOWN AS
 20'-8"
  
 17)BREEZEWAY TRUSS PLAN ON AS-7 SHOW CONNECTOR AS
 MTSM 16 THIS IS A TRUSS TO MASONRY CONNECTOR, WHILE
 TRUSSES ARE CONNECTED TO WOOD BEAM
  
 18)THE ELEVATION SHOWN ON ON A/3 OF 10'-4" PLEASE
 VERIFY IF THIS IS THE TOP OF BEAM/ CONCRETE FLOOR. NOTE
 THAT WALL SECTIONS AS-4 AND AS-5 SHOW 10'-0"
  
 19)PROVIDE THE INSULATION VALUE, METAL STUD SIZE AND
 THE ATTACHMENT METHOD OF THE STUDS FOR THE DRYWALL
 CEILING LOAD.
  
 20)PROVIDE A SECTION TROUGH THE CEILING/ ROOF IN THE
 OPPOSITE DIRECTION TO BETTER SEE THE APPLICATION OF THE
 DIFFERENT LAYERS. IT IS VERY CONFUSING ON WALL SECTION
 PAGE AS-5 WITH ARROWS POINTING TO THE SAME MATERIAL AS
 INSULATION, 2X4 SLEEPER AND LIGHTWEIGHT CONCRETE
  
 21)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-05-11 Cont ID  
Sent By btrobaug Date 2007-05-11 Time 08:52 Rev Time 0.50
Received By btrobaug Date 2007-05-11 Time 08:08 Sent To M
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2007-04-20 Cont ID  
Sent By swurafti Date 2007-04-20 Time 16:14 Rev Time 0.00
Received By swurafti Date 2007-04-20 Time 16:14 Sent To  
Notes
2007-04-20 16:15:05HISTORIC APPROVED BY JPAPA

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-08-16 Cont ID  
Sent By adarroug Date 2007-08-16 Time 13:38 Rev Time 0.00
Received By adarroug Date 2007-08-16 Time 13:38 Sent To B
Notes
2007-08-16 13:38:28TO "AMORSE" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-07-28 Cont ID  
Sent By adarroug Date 2007-07-28 Time 12:28 Rev Time 0.00
Received By adarroug Date 2007-07-28 Time 12:28 Sent To Z
Notes
2007-07-28 12:28:36TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-05-09 Cont ID  
Sent By shill Date 2007-05-09 Time 16:52 Rev Time 0.00
Received By shill Date 2007-05-09 Time 16:52 Sent To E
Notes
2007-05-09 16:53:32TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-06-19 Time   Rev Time 0.00
Received By adarroug Date 2007-04-23 Time 13:48 Sent To  
Notes
2007-04-23 13:48:22TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-07-31 Cont ID  
Sent By tgordon Date 2007-07-31 Time 11:37 Rev Time 0.25
Received By tgordon Date 2007-07-31 Time 11:37 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-05-15 Cont ID  
Sent By tgordon Date 2007-05-15 Time 12:49 Rev Time 0.30
Received By tgordon Date 2007-05-15 Time 12:49 Sent To P
Notes
2007-05-15 12:55:27*** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT
 ALSO, PER 2004 FBC 13-600.3.ABC.2.
  
 2) MECHANICAL PLANS NEED TO BE SIGNED BY DESIGNER. ALL
 INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING
 DATA SHALL BEAR THE PRINTED NAME AND SIGNATURE OF THE
 PERSON RESPONSIBLE FOR THE DESIGN. PER FBC 104.2.1 .
  
 3) NEED TO SHOW GRILL SIZE AND CFM'S AT SUPPLY AIR
 GRILLS THAT WERE YELLOW HIGH LIGHTED ON MECHANICAL
 PLANS.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-08-03 Cont ID  
Sent By mperson Date 2007-08-03 Time 16:02 Rev Time 0.33
Received By mperson Date 2007-08-03 Time 16:02 Sent To B
Notes
2007-08-03 16:16:45*****************PROVISO****************
 PER FBC-2004 PLUMBING SECTION 706.3: DOUBLE SANITARY
 TEE PATTERNS SHALL NOT RECIEVE THE DISCHARGE OF
 FIXTURES OR APPLIANCES WITH PUMPING ACTION DISCHARGE.
 THE FIXTURE DRAINS FOR THE WASHING MACHINE AND SINK TO
 BE SEPERATE SANITARY TEES AT DIFFERENT ELEVATIONS.
  
 REVIEW BY MIKE PERSON
 PLUMBING PLANS EXAMINER
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL= [email protected]

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-05-17 Cont ID  
Sent By mperson Date 2007-05-17 Time 10:48 Rev Time 0.45
Received By mperson Date 2007-05-17 Time 10:48 Sent To B
Notes
2007-05-17 11:51:14DENIED
 REFERENCE:
 ** FBC-2004 PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. SHEETS A-3, AS-4 AND AS-5 ARE INDICATING PARAPET
 WALLS FOR THE PROPOSED ADDITION. PLEASE PROVIDE A ROOF
 PLAN THAT INDICATES HOW THE ROOF WILL BE PITCHED TO
 PROPERLY DRAIN, AND INDICATE THE FOLLOWING INFORMATION
 PER THE FOLLOWING CODE REFERENCES.
 A} DETAIL OF ROOF INDICATING SQUARE FOOTAGE OF ROOF
 AND VERTICAL WALLS (PARAPET) DRAINING TO DOWNSPOUTS AND
 SCUPPERS TO VERIFY COMPLIANCE WITH FBC-2004 PLUMBING,
 SECTION 1106.
 B} VERTICAL CONDUCTORS AND LEADERS, PER FBC-2004
 PLUMBING, SECTION 1106.2
 C} VERTICAL WALLS, PER FBC-2004 PLUMBING, SECTION
 1106.4
 D} SCUPPERS, (PROVIDE DETAIL PER FBC-2004 BUILDING,
 SECTIONS 1503.4.2 AND 1503.4.3) SIZE PER FBC-2004
 PLUMBING, TABLE 1106.7.
 E} SECONDARY (EMERGENCY) ROOF DRAINS, PER FBC-2004
 PLUMBING, SECTION 1107.
 A) SECONDARY DRAINAGE REQUIRED, PER FBC-2004 PLUMBING,
 SECTION 1107.1.
 B) SEPERATE SYSTEMS REQUIRED PER FBC-2004 PLUMBING,
 SECTION 1107.2.
  
 2. SHEET M-9 SANITARY ISOMETRIC RISER DIAGRAM. PLEASE
 CORRECT THE FOLLOWING ON THE RISER DIAGRAM
  
 A}A CLEANOUT IS REQUIRED AT THE BASE OF THE 3" SOIL
 STACK TO THE 2ND FLOOR BATHROOM PER FBC-2004 PLUMBING,
 SECTION 708.3.4. PLEASE CORRECT ON THE RESUBMITTAL.
  
 B} A VENT IS REQUIRED FOR THE 2ND FLOOR SHOWER PER
 FBC-2004 PLUMBING, SECTION 901.2.1.
  
 C} PLEASE INDICATE THE STANDPIPE FOR THE WASHING
 MACHINE PER FBC-2004 PLUMBING, SECTIONS 406.3 AND
 802.4.
  
 D} PLEASE INDICATE THE CLEANOUT FOR THE WASHING
 MACHINE TO BE LOCATED AT FOUR FEET ABOVE FINNISH FLOOR
 (4' A.F.F.) PER FBC-2004 PLUMBING, SECTION 708.9.
  
 3. FBC-2004 CHAPTER 1,SECTION 106.3.4.2:
 THE PERSON RESPONSIBLE FOR THE DESIGN OF
 THE DRAWING SHALL CLEARLY PRINT AND SIGN
 NAME, AND ALSO DATE DRAWING. PLEASE DO
 THIS PRIOR TO RESUBMITTING.
  
 ********IMPORTANT INFORMATION********
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY.
 NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop Z ZONING
Rev No 3 Status P Date 2007-07-31 Cont ID  
Sent By choops Date 2007-07-31 Time 10:41 Rev Time 0.00
Received By choops Date 2007-07-31 Time 10:41 Sent To M
Notes
2007-07-31 10:50:31PROVISO:ANY PROPOSED MECHANICAL/A/C EQUIPMENT SHALL
 NOT EXTEND MORE THAN 4' INTO ANY REQUIRED SETBACK.

Review Stop Z ZONING
Rev No 2 Status F Date 2007-07-30 Cont ID  
Sent By choops Date 2007-07-30 Time 13:29 Rev Time 0.00
Received By choops Date 2007-07-30 Time 13:29 Sent To HIST
Notes
2007-07-30 13:29:46NEEDS APPROVED AND RESTAMPED BY HISTORIC PRESERVATION

Review Stop Z ZONING
Rev No 1 Status F Date 2007-05-07 Cont ID  
Sent By choops Date 2007-05-07 Time 16:56 Rev Time 0.00
Received By choops Date 2007-05-07 Time 16:56 Sent To I
Notes
2007-05-07 17:01:30***FAILED***
  
  
 1)PLEASE PROVIDE ELEVATION FROM GRADE TO TOP OF
 PARAPET.
  
 2)PLEASE PROVIDE DIMENSIONS OF ROOF OVERHANGS.
  
 3)ELEVATIONS DON'T MATCH WITH REGARDS TO EAST
 ELEVATION.DETAIL SHOWS AS A FLAT WALL WITH NO
 OVERHANG, NORTH ELEVATION DOES SHOW OVERHANG.
  
  
 CHRIS HOOPS
 ZONING TECHNICIAN
 561-805-6720