| Plan Review Stops For Permit 07040703 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-08-22 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-08-22 |
Time |
10:56 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-08-22 |
Time |
07:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-06-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-06-03 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-06-03 |
Time |
12:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-05-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-05-03 |
Time |
08:02 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-05-02 |
Time |
18:36 |
Sent To |
|
|
| Notes |
| 2007-05-03 07:54:45 | BUILDING PLAN REVIEW | | | PERMIT: 07040703 | | | ADD: 525 S. FLAGLER DR. PH 3 A&B | | | CONT: OTIS CONST INC. | | | TEL: (561)582-0636 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 1ST | | | ACTION: DENIED | | | | | | 1)SUBMIT A WALL LEGEND WITH THE DIFFERENT TYPE OF | | | WALLS. ALSO SHOW THE DIFFERENT INTERIOR ELEVATIONS OF | | | THE NEW CEILINGS. | | | | | | 3)61G1-16.004 TITLE BLOCK. | | | A TITLE BLOCK MUST APPEAR ON ALL ARCHITECTURAL OR | | | INTERIOR DESIGN DRAWINGS AND SPECIFICATION | | | IDENTIFICATION SHEETS. THE TITLE BLOCK MUST, AT A | | | MINIMUM, CONTAIN THE FOLLOWING INFORMATION: | | | (1) FIRM NAME, ADDRESS, AND TELEPHONE NUMBER. | | | (2) FIRM LICENSE NUMBER. | | | (3) NAME OR IDENTIFICATION OF PROJECT. | | | (4) DATE PREPARED. | | | (5) A SPACE FOR THE SIGNATURE AND DATED SEAL. | | | (6) A SPACE FOR THE PRINTED NAME OF THE PERSON SEALING | | | THE DOCUMENT. | | | PROVIDE THE CERTIFICATE OF AUTHORIZATION NUMBER FOR | | | GLEN P. HARRIS,A.I.AARCHITECTS . PLANNERS . | | | INTERIORS. | | | | | | 4)110.2* W. P. B. ADMINISTRATIVE | | | CODE, INFORMATION THAT IS REQUIRED FOR | | | RECORD KEEPING & FOR CERTIFICATE OF | | | OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH | | | THE PROJECT WAS DESIGNED. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | | WITH THE PROVISIONS OF CHAPTER 3. | | | ) NUMBER OF FLOORS | | | ) NUMBER OF BEDROOMS | | | ) NUMBER OF ROOMS | | | ) NUMBER OF BATHROOMS | | | ) SQ. FT. LIV SPACE/ FL | | | ) SQ. FT. UNDER ROOF (TOTAL) | | | | | | 5)THE PROPOSED BUILDING STRUCTURE | | | TRANSGRESSES LEGAL BOUNDARY LINES | | | BETWEEN THE LOTS WHICH COMBINE TO FORM | | | 'THE SITE'.A 'UNITY OF TITLE' SHALL BE | | | RECORDED AT THE COUNTY COURTHOUSE. | | | SUBMIT A COPY OF THE RECORDED 'UNITY OF | | | OF TITLE' DOCUMENT SO THAT FBC TABLE 600 | | | BOUNDARY LINE REQUIREMENTS MAY BE DEEMED | | | NOT APPLICABLE. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-08-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-08-22 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-08-22 |
Time |
15:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-05-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-05-25 |
Time |
09:10 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2007-05-25 09:10:43 | | | | | | | REDLINED 1 RECEPTACLE IN THE MASTER BATH PER 210.52(D), | | | AND RANGE WIRE SIZE # !0 TO #6 ON A 60 AMP.OCP. | | | 310.16./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2007-04-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-04-27 |
Time |
15:47 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2007-04-27 |
Time |
15:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-08-23 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-08-23 |
Time |
12:04 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-08-23 |
Time |
11:50 |
Sent To |
|
|
| Notes |
| 2007-08-23 11:58:11 | *****REVISION APPROVED***** | | | | | | REVISED PLAN SHEET A1.2 STAMPED, INITIALED, AND DATED. | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-05-30 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-05-30 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-05-30 |
Time |
10:30 |
Sent To |
|
|
| Notes |
| 2007-05-30 10:32:36 | *****APPROVED***** | | | | | | | | | ALL COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | | BEEN ADDRESSED;PLAN SHEET A1.2 STAMPED, INITIALED, | | | AND DATED. | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-05-03 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-05-03 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-05-03 |
Time |
12:16 |
Sent To |
|
|
| Notes |
| 2007-05-03 12:53:12 | *****DENIED***** | | | | | | | | | 1.CONSTRUCTION, ALTERATION, OR DEMOLITION OPERATIONS | | | SHALL COMPLY WITH NFPA 241. | | | | | | 2.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL | | | BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR | | | MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. | | | | | | 3.THE DEMOLITION OF EXISTING AND/OR THE STOCKING OF | | | NEW BUILDING MATERIALS & SUPPLIES SHALL NOT INTERFERE | | | OR HINDER ACCESS TO OR EGRESS FROM THE FLOOR OR THE | | | BUILDING. | | | | | | 4.NEW INTERIOR WALL AND CEILING FINISH MATERIALS | | | SHALL BE CLASS A, CLASS B, OR CLASS C.PLEASE | | | SPECIFY. | | | | | | 5.AS PER YOUR PERMIT APPLICATION, IT IS STATED THAT | | | THE SCOPE OF WORK INCLUDES CHANGES TO THE FIRE | | | SPRINKLER DEVICES.BE ADVISED, AS PER WEST PALM BEACH | | | FIRE PREVENTION BUREAU, NO SEPARATE PLANS AND PERMIT | | | ARE REQUIRED WHEN THE ALTERATION INVOLVES LESS THAN | | | FIVE (5) HEADS AS LONG AS THE WORK IS DONE BY A | | | CERTIFIED FIRE SPRINKLER CONTRACTOR.HOWEVER, A LAYOUT | | | OF THE SPRINKLER HEADS IN THE AFFECTED AREA ALONG WITH | | | THE MODIFICATIONS WILL BE REQUIRED FOR PLAN REVIEW AND | | | COMPLIANCE. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A REPONSE | | | LETTER INDICATING HOW/WHERE EACH COMMENT WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-08-29 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-29 |
Time |
16:26 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-29 |
Time |
16:26 |
Sent To |
M |
|
| Notes |
| 2007-08-29 16:26:28 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-08-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-07 |
Time |
21:03 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-07 |
Time |
21:03 |
Sent To |
|
|
| Notes |
| 2007-08-21 10:55:32 | TO "BOB"#6 | | 2007-08-07 21:04:15 | WAITING FOR BOB BOARD. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-05-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-15 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-15 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2007-05-22 11:36:06 | TO "BOB"#18 | | 2007-05-15 14:59:48 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-05-03 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-05-03 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-04-23 |
Time |
10:19 |
Sent To |
|
|
| Notes |
| 2007-04-23 10:21:32 | TO "BOB"#15 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-10-02 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2007-10-02 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2007-10-02 |
Time |
14:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-09-05 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-09-05 |
Time |
09:00 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-09-05 |
Time |
09:00 |
Sent To |
|
|
| Notes |
| 2007-09-05 09:01:23 | *** PROVISO *** | | | 1) DOOR D15 TO EXISTING MECHANICAL ROOM WILL COMPLY | | | WITH 2004 FBC/M 602.2.1 MATERIALS EXPOSED WITHIN | | | PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL HAVE A FLAME | | | SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED | | | INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE | | | WITH ASTM E 84. | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-08-23 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-23 |
Time |
10:46 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-08-23 |
Time |
10:46 |
Sent To |
|
|
| Notes |
| 2007-08-23 11:13:05 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (WPB), FLORIDA | | | ADMINISTRATIVE CODE (FAC), AND FLORIDA STATUTES (FS). | | | | | | *** DENIED *** | | | 1) IT APPEARS MOST DUCT WORK AND GRILLS ARE BEING | | | REPLACED OR RELOCATED. PLEASE SUBMIT MECHANICAL PLANS | | | SHOWING ALL DUCT WORK WITH SIZES AND LIST AS NEW OR | | | EXISTING. PLEASE DO NOT SHOW OLD LOCATION OF GRILLS | | | BEING REMOVED. | | | | | | 2) WHEN SHOWING DUCT SIZES DO NOT SHOW AS 5? OR 7? | | | BECAUSE I DO NOT KNOW THE DUCT SIZES AND CAN NOT ANSWER | | | THE QUESTION. | | | | | | 3) THE MECHANICAL PLAN HAS TO MUCH FURNITURE AND TILE | | | FLOOR DETAIL ON IT AND IS DIFFICULT TO READ. | | | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY. | | | PER 2004 FBC 106.1.1. | | | | | | 4) SHOW ALL SUPPLY AIR GRILLS WITH SIZES AND LIST AS | | | NEW OR EXISTING, ALSO SHOW LOCATION OF RETURN AIR | | | GRILLS. | | | | | | 5) PLAN SHOWS A HEAT PUMP UNIT IS TO BE REPLACED, | | | PLEASE PROVIDE AN EQUIPMENT LISTING. | | | | | | 6) PROVIDE OUT-SIDE AIR CALCULATIONS AND OUT-SIDE AIR | | | IF REQUIRES, SEE MECH. 401.2. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] | | | | | | | | | . |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2007-05-22 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-05-22 |
Time |
12:07 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-05-22 |
Time |
12:07 |
Sent To |
|
|
| Notes |
| 2007-05-22 12:13:25 | *** PROVISO *** | | | 1) DOOR D15 TO EXISTING MECHANICAL ROOM WILL COMPLY | | | WITH 2004 FBC/M 602.2.1 MATERIALS EXPOSED WITHIN | | | PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL HAVE A FLAME | | | SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED | | | INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE | | | WITH ASTM E 84. | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-04-25 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-04-25 |
Time |
10:36 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-04-25 |
Time |
10:36 |
Sent To |
|
|
| Notes |
| 2007-04-25 10:56:38 | *** DENIED *** | | | 1) MECHANICAL PLANS PAGE M1.1 SHOW NO SUPPLY OR RETURN | | | AIR GRILLS FOR GUEST BEDROOM #106, PLEASE CORRECT. | | | | | | 2) PLEASE SHOW CLOTHES DRYER VENT ON MECHANICAL PLANS, | | | SEE 2004 FBC/M 504. | | | | | | 3) PLEASE SHOW ON PLANS DOOR D15 TO EXISTING MECHANICAL | | | ROOM AT MASTER HALL IS A NONCOMBUSTIBLE DOOR, SEE 2004 | | | FBC.M 602.2.1. | | | | | | 4) MECHANICAL PLANS PAGE M1.1 SHOWS IN LIVING ROOM #102 | | | AND SITTING #114, "1 INCH R.A. SLOT CONTINUOUS, SEE | | | ARCH. DWG.". COULD NOT FIND ANY ARCHITECTURAL DRAWING | | | FOR THIS, PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-06-05 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-06-05 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-06-05 |
Time |
09:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-05-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-05-03 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-05-03 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2007-05-03 10:20:21 | DENIED; | | | 1. SEE BUILDING PLAN REVIEW NOTE 3. | | | 2. ADD NOTE TO DEMO PAGE; "PLUMBING DEMO BY LICENSED | | | PLUMBING CONTRACTOR INSPECTION REQUIRED. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2007-08-21 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-08-21 |
Time |
17:21 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-08-21 |
Time |
17:21 |
Sent To |
|
|
| Notes |
| 2007-08-21 17:22:01 | *ZONING REVIEW NOT REQUIRED - VALUE OF PROPOSED WORK | | | DOES NOT EXCEED 50% OF THE IMPROVEMENT VALUE. |
|
|