Plan Review Details - Permit 07040703
Plan Review Stops For Permit 07040703
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-08-22 Cont ID  
Sent By mjacobs Date 2007-08-22 Time 10:56 Rev Time 0.00
Received By mjacobs Date 2007-08-22 Time 07:58 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-06-03 Cont ID  
Sent By mjacobs Date 2007-06-03 Time 13:00 Rev Time 0.00
Received By mjacobs Date 2007-06-03 Time 12:21 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-05-03 Cont ID  
Sent By mjacobs Date 2007-05-03 Time 08:02 Rev Time 0.00
Received By mjacobs Date 2007-05-02 Time 18:36 Sent To  
Notes
2007-05-03 07:54:45BUILDING PLAN REVIEW
 PERMIT: 07040703
 ADD: 525 S. FLAGLER DR. PH 3 A&B
 CONT: OTIS CONST INC.
 TEL: (561)582-0636
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 1ST
 ACTION: DENIED
  
 1)SUBMIT A WALL LEGEND WITH THE DIFFERENT TYPE OF
 WALLS. ALSO SHOW THE DIFFERENT INTERIOR ELEVATIONS OF
 THE NEW CEILINGS.
  
 3)61G1-16.004 TITLE BLOCK.
 A TITLE BLOCK MUST APPEAR ON ALL ARCHITECTURAL OR
 INTERIOR DESIGN DRAWINGS AND SPECIFICATION
 IDENTIFICATION SHEETS. THE TITLE BLOCK MUST, AT A
 MINIMUM, CONTAIN THE FOLLOWING INFORMATION:
 (1) FIRM NAME, ADDRESS, AND TELEPHONE NUMBER.
 (2) FIRM LICENSE NUMBER.
 (3) NAME OR IDENTIFICATION OF PROJECT.
 (4) DATE PREPARED.
 (5) A SPACE FOR THE SIGNATURE AND DATED SEAL.
 (6) A SPACE FOR THE PRINTED NAME OF THE PERSON SEALING
 THE DOCUMENT.
 PROVIDE THE CERTIFICATE OF AUTHORIZATION NUMBER FOR
 GLEN P. HARRIS,A.I.AARCHITECTS . PLANNERS .
 INTERIORS.
  
 4)110.2* W. P. B. ADMINISTRATIVE
 CODE, INFORMATION THAT IS REQUIRED FOR
 RECORD KEEPING & FOR CERTIFICATE OF
 OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH
 THE PROJECT WAS DESIGNED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 ) NUMBER OF FLOORS
 ) NUMBER OF BEDROOMS
 ) NUMBER OF ROOMS
 ) NUMBER OF BATHROOMS
 ) SQ. FT. LIV SPACE/ FL
 ) SQ. FT. UNDER ROOF (TOTAL)
  
 5)THE PROPOSED BUILDING STRUCTURE
 TRANSGRESSES LEGAL BOUNDARY LINES
 BETWEEN THE LOTS WHICH COMBINE TO FORM
 'THE SITE'.A 'UNITY OF TITLE' SHALL BE
 RECORDED AT THE COUNTY COURTHOUSE.
 SUBMIT A COPY OF THE RECORDED 'UNITY OF
 OF TITLE' DOCUMENT SO THAT FBC TABLE 600
 BOUNDARY LINE REQUIREMENTS MAY BE DEEMED
 NOT APPLICABLE.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2007-08-22 Cont ID  
Sent By btrobaug Date 2007-08-22 Time 15:50 Rev Time 0.00
Received By btrobaug Date 2007-08-22 Time 15:47 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-05-25 Cont ID  
Sent By btrobaug Date 2007-05-25 Time 09:10 Rev Time 0.50
Received By btrobaug Date   Time   Sent To  
Notes
2007-05-25 09:10:43 
  
 REDLINED 1 RECEPTACLE IN THE MASTER BATH PER 210.52(D),
 AND RANGE WIRE SIZE # !0 TO #6 ON A 60 AMP.OCP.
 310.16./WRT.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-04-27 Cont ID  
Sent By btrobaug Date 2007-04-27 Time 15:47 Rev Time 0.75
Received By btrobaug Date 2007-04-27 Time 15:47 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2007-08-23 Cont ID  
Sent By mawillia Date 2007-08-23 Time 12:04 Rev Time 0.00
Received By mawillia Date 2007-08-23 Time 11:50 Sent To  
Notes
2007-08-23 11:58:11*****REVISION APPROVED*****
  
 REVISED PLAN SHEET A1.2 STAMPED, INITIALED, AND DATED.
  
  
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2007-05-30 Cont ID  
Sent By mawillia Date 2007-05-30 Time 11:06 Rev Time 0.00
Received By mawillia Date 2007-05-30 Time 10:30 Sent To  
Notes
2007-05-30 10:32:36*****APPROVED*****
  
  
 ALL COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE
 BEEN ADDRESSED;PLAN SHEET A1.2 STAMPED, INITIALED,
 AND DATED.
  
  
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2007-05-03 Cont ID  
Sent By mawillia Date 2007-05-03 Time 12:53 Rev Time 0.00
Received By mawillia Date 2007-05-03 Time 12:16 Sent To  
Notes
2007-05-03 12:53:12*****DENIED*****
  
  
 1.CONSTRUCTION, ALTERATION, OR DEMOLITION OPERATIONS
 SHALL COMPLY WITH NFPA 241.
  
 2.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL
 BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR
 MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION.
  
 3.THE DEMOLITION OF EXISTING AND/OR THE STOCKING OF
 NEW BUILDING MATERIALS & SUPPLIES SHALL NOT INTERFERE
 OR HINDER ACCESS TO OR EGRESS FROM THE FLOOR OR THE
 BUILDING.
  
 4.NEW INTERIOR WALL AND CEILING FINISH MATERIALS
 SHALL BE CLASS A, CLASS B, OR CLASS C.PLEASE
 SPECIFY.
  
 5.AS PER YOUR PERMIT APPLICATION, IT IS STATED THAT
 THE SCOPE OF WORK INCLUDES CHANGES TO THE FIRE
 SPRINKLER DEVICES.BE ADVISED, AS PER WEST PALM BEACH
 FIRE PREVENTION BUREAU, NO SEPARATE PLANS AND PERMIT
 ARE REQUIRED WHEN THE ALTERATION INVOLVES LESS THAN
 FIVE (5) HEADS AS LONG AS THE WORK IS DONE BY A
 CERTIFIED FIRE SPRINKLER CONTRACTOR.HOWEVER, A LAYOUT
 OF THE SPRINKLER HEADS IN THE AFFECTED AREA ALONG WITH
 THE MODIFICATIONS WILL BE REQUIRED FOR PLAN REVIEW AND
 COMPLIANCE.
  
  
 TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A REPONSE
 LETTER INDICATING HOW/WHERE EACH COMMENT WAS ADDRESSED
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-08-29 Cont ID  
Sent By adarroug Date 2007-08-29 Time 16:26 Rev Time 0.00
Received By adarroug Date 2007-08-29 Time 16:26 Sent To M
Notes
2007-08-29 16:26:28TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-08-07 Cont ID  
Sent By dpalmer Date 2007-08-07 Time 21:03 Rev Time 0.00
Received By dpalmer Date 2007-08-07 Time 21:03 Sent To  
Notes
2007-08-21 10:55:32TO "BOB"#6
2007-08-07 21:04:15WAITING FOR BOB BOARD.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-05-15 Cont ID  
Sent By adarroug Date 2007-05-15 Time 14:59 Rev Time 0.00
Received By adarroug Date 2007-05-15 Time 14:59 Sent To  
Notes
2007-05-22 11:36:06TO "BOB"#18
2007-05-15 14:59:48WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-05-03 Cont ID  
Sent By mawillia Date 2007-05-03 Time 12:53 Rev Time 0.00
Received By mawillia Date 2007-04-23 Time 10:19 Sent To  
Notes
2007-04-23 10:21:32TO "BOB"#15

Review Stop M MECHANICAL (A/C)
Rev No 5 Status P Date 2007-10-02 Cont ID  
Sent By hmoser Date 2007-10-02 Time 14:50 Rev Time 0.00
Received By hmoser Date 2007-10-02 Time 14:50 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2007-09-05 Cont ID  
Sent By tgordon Date 2007-09-05 Time 09:00 Rev Time 0.25
Received By tgordon Date 2007-09-05 Time 09:00 Sent To  
Notes
2007-09-05 09:01:23*** PROVISO ***
 1) DOOR D15 TO EXISTING MECHANICAL ROOM WILL COMPLY
 WITH 2004 FBC/M 602.2.1 MATERIALS EXPOSED WITHIN
 PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL HAVE A FLAME
 SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED
 INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE
 WITH ASTM E 84.
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2007-08-23 Cont ID  
Sent By tgordon Date 2007-08-23 Time 10:46 Rev Time 0.45
Received By tgordon Date 2007-08-23 Time 10:46 Sent To  
Notes
2007-08-23 11:13:05PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE &
 REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST
 PALM BEACH AMENDMENTS TO CHAPTER 1 (WPB), FLORIDA
 ADMINISTRATIVE CODE (FAC), AND FLORIDA STATUTES (FS).
  
 *** DENIED ***
 1) IT APPEARS MOST DUCT WORK AND GRILLS ARE BEING
 REPLACED OR RELOCATED. PLEASE SUBMIT MECHANICAL PLANS
 SHOWING ALL DUCT WORK WITH SIZES AND LIST AS NEW OR
 EXISTING. PLEASE DO NOT SHOW OLD LOCATION OF GRILLS
 BEING REMOVED.
  
 2) WHEN SHOWING DUCT SIZES DO NOT SHOW AS 5? OR 7?
 BECAUSE I DO NOT KNOW THE DUCT SIZES AND CAN NOT ANSWER
 THE QUESTION.
  
 3) THE MECHANICAL PLAN HAS TO MUCH FURNITURE AND TILE
 FLOOR DETAIL ON IT AND IS DIFFICULT TO READ.
 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY.
 PER 2004 FBC 106.1.1.
  
 4) SHOW ALL SUPPLY AIR GRILLS WITH SIZES AND LIST AS
 NEW OR EXISTING, ALSO SHOW LOCATION OF RETURN AIR
 GRILLS.
  
 5) PLAN SHOWS A HEAT PUMP UNIT IS TO BE REPLACED,
 PLEASE PROVIDE AN EQUIPMENT LISTING.
  
 6) PROVIDE OUT-SIDE AIR CALCULATIONS AND OUT-SIDE AIR
 IF REQUIRES, SEE MECH. 401.2.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729
 E-MAIL; [email protected]
  
  
 .

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-05-22 Cont ID  
Sent By tgordon Date 2007-05-22 Time 12:07 Rev Time 0.25
Received By tgordon Date 2007-05-22 Time 12:07 Sent To  
Notes
2007-05-22 12:13:25*** PROVISO ***
 1) DOOR D15 TO EXISTING MECHANICAL ROOM WILL COMPLY
 WITH 2004 FBC/M 602.2.1 MATERIALS EXPOSED WITHIN
 PLENUMS SHALL BE NONCOMBUSTIBLE OR SHALL HAVE A FLAME
 SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED
 INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE
 WITH ASTM E 84.
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-04-25 Cont ID  
Sent By tgordon Date 2007-04-25 Time 10:36 Rev Time 0.30
Received By tgordon Date 2007-04-25 Time 10:36 Sent To  
Notes
2007-04-25 10:56:38*** DENIED ***
 1) MECHANICAL PLANS PAGE M1.1 SHOW NO SUPPLY OR RETURN
 AIR GRILLS FOR GUEST BEDROOM #106, PLEASE CORRECT.
  
 2) PLEASE SHOW CLOTHES DRYER VENT ON MECHANICAL PLANS,
 SEE 2004 FBC/M 504.
  
 3) PLEASE SHOW ON PLANS DOOR D15 TO EXISTING MECHANICAL
 ROOM AT MASTER HALL IS A NONCOMBUSTIBLE DOOR, SEE 2004
 FBC.M 602.2.1.
  
 4) MECHANICAL PLANS PAGE M1.1 SHOWS IN LIVING ROOM #102
 AND SITTING #114, "1 INCH R.A. SLOT CONTINUOUS, SEE
 ARCH. DWG.". COULD NOT FIND ANY ARCHITECTURAL DRAWING
 FOR THIS, PLEASE CORRECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-06-05 Cont ID  
Sent By jleech Date 2007-06-05 Time 09:17 Rev Time 0.00
Received By jleech Date 2007-06-05 Time 09:17 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-05-03 Cont ID  
Sent By jleech Date 2007-05-03 Time 10:01 Rev Time 0.00
Received By jleech Date 2007-05-03 Time 10:01 Sent To  
Notes
2007-05-03 10:20:21DENIED;
 1. SEE BUILDING PLAN REVIEW NOTE 3.
 2. ADD NOTE TO DEMO PAGE; "PLUMBING DEMO BY LICENSED
 PLUMBING CONTRACTOR INSPECTION REQUIRED.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status N Date 2007-08-21 Cont ID  
Sent By choops Date 2007-08-21 Time 17:21 Rev Time 0.00
Received By choops Date 2007-08-21 Time 17:21 Sent To  
Notes
2007-08-21 17:22:01*ZONING REVIEW NOT REQUIRED - VALUE OF PROPOSED WORK
 DOES NOT EXCEED 50% OF THE IMPROVEMENT VALUE.