| 2007-06-04 16:35:53 | BUILDING PLAN REVIEW |
| | PERMIT: 07040698 |
| | ADD: 6118 WILDCAT RUN |
| | CONT: WILLIAM BELL CONSTRUCTION |
| | TEL: (561)741-8655 |
| | |
| | |
| | FL BLD CODE= 2004 FLORIDA RESIDENTIAL CODE |
| | W/ 2006 FBC REVISIONS |
| | * WEST PALM BEACH AMENDMENTS |
| | |
| | 2NDREVIEW |
| | ACTION: DENIED |
| | |
| | 1)--- VERY IMPORTANT STATEMENT --- |
| | PLEASE DO NOT IGNORE! |
| | WHEN RESUBMITTING PLANS PLEASE INDICATE |
| | THE REVISION & REMOVE & REPLACE ANY |
| | PAGES AS NECESSARY. A TRANSMITTAL LETTER |
| | LISTING THE ORIGINAL REVIEW COMMENT NUM- |
| | BER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICA |
| | TION PAGE WHERE THE CHANGES CAN BE FOUND |
| | WILL HELP TO EXPEDITE YOUR PERMIT. THANK |
| | YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | SUBMITTED ARE MANUFACTURERERS SPECS FOR MAJESTIC BR/BC |
| | WOODBURNING FIREPLACES |
| | |
| | HIGHLIGHTED ON SHEET 20 UNDER CAUTION:IT STATES IF |
| | YOU USE AN UNAPPROVED COMPONENT TO MAKE ANY |
| | MODIFICATIONS, YOU MAY CREATE A POSSIBLE FIRE HAZARD |
| | AND WILL VOID THE CFM CORPORATION WARRANTY. |
| | RESIDENTIAL CODE 1002.1 FACTORY-BUILT CHIMNEYS SHALL BE |
| | LISTED AND LABELED AND SHALL BE |
| | INSTALLED AND TERMINATED IN ACCORDANCE WITH THE |
| | MANUFACTURER'S INSTALLATION INSTRUCTIONS. |
| | |
| | R1002.2 DECORATIVE SHROUD. DECORATIVE SHROUDS SHALL NOT |
| | BE INSTALLED AT THE TERMINATION OF A FACTORY-BUILT |
| | CHIMNEYS EXCEPT WHERE SHROUDS ARE LISTED AND LABELED |
| | FOR USE WITH THE SPECIFICFACTORY-BUILT CHIMNEY |
| | SYSTEMAND INSTALLED IN ACCORDANCE WITH THE MANUFACTER'S |
| | INSTALLATIONINSTRUCTIONS. |
| | |
| | RESIDENTIAL CODE 1002.1 FACTORY-BUILT CHIMNEYS SHALL BE |
| | LISTED AND LABELED AND SHALL BE INSTALLED AND |
| | TERMINATED IN ACCORDANCE WITH THE MANUFACTURER'S |
| | INSTALLATION INSTRUCTIONS. |
| | PLEASE PROVIDE THE MANUFACTURER'S INSTALLATION |
| | INSTRUCTIONS IT APPEARS IN THIS DRAWING THESPARK |
| | ARESTOR IS MISSING. |
| | |
| | DESIGN#1 FROM ARCHITECT STEPHENYECKES; WRITTEN |
| | NOTIRIZED PERMISSION WILL NEED TO BE SOUGHT FROM THE |
| | MANUFACTURERER FOR THE PROPOSED DECORATIVE WEATHER |
| | HEAD. IN SPEAKING WITH THE DESIGN PROFESSIONAL IT WAS |
| | STATED WRITTEN APPROVAL MUST BE OBTAINED, AND NO |
| | COMBUSTIBLE MATERIAL WOULD BE ALLOWED ABOVE THE PAN |
| | FLASHING AND STORM COLLAR. IN THE PRESENT DESIN PLANS |
| | STILL INDICATE THE USE OF FOAM TRIM AND THE DECKING FOR |
| | THE WALLS AND ROOF SHEATHING AREN'T IDENTIFIED. PLANS |
| | ALSO NOW INDICATE THE FRAMING TO BE METAL STUDS BUT NO |
| | CONSIDERATION HAS BEEN GIVEN TO BRACING NOR THE BOTTOM |
| | ANCHOR HAS BEEN IDENTIFIED. |
| | |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER C. B. O. |
| | |
| | TEL: (561)805-6715 |
| | FAX: (561)659-8026 |
| | E-MAIL: [email protected] |