| Plan Review Stops For Permit 07040545 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2008-04-17 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-04-17 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-04-17 |
Time |
14:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2008-03-04 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2008-03-04 |
Time |
11:15 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2008-03-04 |
Time |
11:15 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-11-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-11-16 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-11-16 |
Time |
14:56 |
Sent To |
PC |
|
| Notes |
| 2007-11-16 15:27:00 | RESIDENTIAL REPAIRS BUILDING REVIEW SECOND CHECKLIST. | | | REVIEW DONE UNDER EXISTING BUILDING CODE 2004, FLORIDA | | | RESIDENTIAL CODE 2004 WITH 2007 REVISIONS. | | | | | | 1- PLANS SUBMITTED DON'T SHOW ANY WORK TO BE PERFORMED | | | OTHER THAN ELECTRICAL, PLUMBING AND MECHANICAL.PLANS | | | NEED TO SPECIFY EXTENT OF WORK AND SPECIFIC LOCATION OF | | | WORK TO BE PERFORMED AS CALLED FOR IN THE PERMIT | | | APPLICATION. SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | 2- NOWIS NOT CLEAR WHAT'S THE REAL SCOPE OF WORK TO | | | BE PERFORMED. PERMIT APPLICATION CALLS FOR "R/R | | | DRYWALL, INSULATION, ELECTRIC, R/R | | | TUB/TOILET/SINK/VANITY".OWNER RESPONSE LETTER STATES | | | THATNO WINDOWS ARE TO BE REPLACED (COMMENT FROM | | | PREVIOUS CHECKLIST),ONLY THE WINDOW A/C UNITS ARE TO | | | BE REPLACED. NOW IT'S NOT CLEAR WHY REPLACING THE | | | WINDOW UNITS AND ALSOSHOWING A/C PLANS?. IN ADDITION, | | | OWNER STATES THAT THERE ARE SOME WALLS THAT NEED THE | | | WOODSTUDS TO BE REPLACED.PLANS DON'T SHOW ANY OF | | | THIS WORK OR ANY SPECIFIC LOCATION FOR THIS WORK TO BE | | | PERFORMED. | | | PLEASE,COORDINATE ALL WORK TO BE PERFORMED IN THIS | | | HOUSE AND PROVIDE SUCH INFORMATION IN THE PLANS DRAWN | | | BY THE CERTIFIED BUILDING CONTRACTOR(SANTORO | | | CONSTRUCTION, INC.) WHO DREW THE PLANS. | | | | | | 3- UPDATE VALUATION TO INCLUDE ALL WORK TO BE PERFORMED | | | IN ALL TRADES AS REQUIRED BY SEC. 108.3 CITY AMENDMENTS | | | TO FBC 2004.REVISED VALUE OF $11,000 DOESN'T COVER | | | ALL PROPOSED SCOPE OF WORK. | | | | | | 4- PLANS NEED TO HAVE THE NAME AND ORIGINAL SIGNATURE | | | OF THE CERTIFIED BUILDING CONTRACTOR WHO DESIGNED THE | | | THE PLANS AS REQUIRED BY SEC. 106.3.4.3CITY | | | AMENDMENTS TO FBC 2004. | | | | | | 5- NEED RECORDED NOTICE OF COMMENCEMENT. ONE PROVIDED | | | WAS RECORDED ON 04/19/2007. NOTICE OF COMMENCEMENT IS | | | EXPIRED AFTER 90 DAYSIF WORK IS NOT STARTED AFTER IT | | | WAS RECORDED. NEED TO PROVIDE RE-RECORDED NOTICE OF | | | COMMENCEMENT. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-06-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-06-27 |
Time |
11:13 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-06-27 |
Time |
11:13 |
Sent To |
PC |
|
| Notes |
| 2007-06-27 12:33:43 | BUILDING REVIEW CHECKLIST: | | | 1- ATTACHED LETTER STATES REPLACING THREE EXISTING | | | WINDOWS. NEED TO PROVIDE2 COPIES OF PRODUCT APPROVALS | | | FOR THE WINDOWS AS REQUIRED BY DCA RULE 9B-72. SPECIFY | | | TYPE AND SIZE OF EXISTING WINDOW AND TYPE AND SIZE OF | | | PROPOSED WINDOW TO VERIFY COMPLIANCE WITH EGRESS | | | REQUIREMENTS IF WINDOWS ARE LOCATED IN BEDROOMS. | | | | | | 2- PERMIT APPLICATION CALLS FOR DRYWALL AND INSULATION | | | INSTALLATION. NEED TO PROVIDE THE ENERGY CALCULATIONS | | | AS REQUIRED BY CHAPTER 13 FBC 2004.COMPLETELY FILL | | | OUT BOTH SIDES OF ATTACHED ENERGY CALCULATIONS FORMS. | | | INCLUDING TOP OF FORM AND BOTTOM OF FORM TO BE SIGNED | | | AND DATED ACCORDINGLY. | | | | | | 3- SKETCHES SUBMITTED TO SHOW AREAS WHERE DRYWALL , | | | INSULATION AND WINDOWS AREGOING TO BE INSTALLED. | | | SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | 4- PERMIT VALUATION DECLARED IN THE PERMIT APPLICATION | | | IS TOO LOW.PERMIT VALUATION NEEDS TO INCLUDE ALL | | | MATERIALS AND LABOR FOR ALL THE WORK TO BE PERFORMED, | | | INCLUDING ALL ELECTRICAL AND PLUMBING WORK.UPDATE | | | PERMIT VALUATION AS REQUIRED BY SEC. 108.3 CITY | | | AMENDMENTS TO FBC 2004. | | | | | | 5- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY | | | SEC. 713.13 FLORIDA STATUTE. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-04-24 |
|
|
Cont ID |
|
| Sent By |
kconrad |
Date |
2007-04-24 |
Time |
19:40 |
Rev Time |
0.00 |
| Received By |
kconrad |
Date |
2007-04-24 |
Time |
19:40 |
Sent To |
I |
|
| Notes |
| 2007-04-24 19:41:04 | REQUIRE PLANS/ELECTRICAL AND PLUMBING PERMITS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2008-04-10 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-04-10 |
Time |
14:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-04-10 |
Time |
14:55 |
Sent To |
M |
|
| Notes |
| 2008-04-10 14:58:56 | ** REDLINED ELECTRICAL PLANS. | | | THE OCP SHOWN ON AHU DOES STILL NOT MEET 424.3B. MIN | | | OCP 60AMPS. | | | ** PLANS ROUTED TO MECH AS NEW SHEETS WERE SUBMITTED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2008-03-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-03-03 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-03-03 |
Time |
09:52 |
Sent To |
M |
|
| Notes |
| 2008-03-03 09:52:13 | ** DENIED 3RD REVIEW ** | | | | | | ** MANY COMMENTS ARE NEW AS THESE THINGS ARE JUST NOW | | | BEING SHOWN. | | | | | | 1) NOTE: PLEASE SEE 424.3B AS THE MINIMUM OVER CURRENT | | | PROTECTION FOR THE AHU NEEDS TO BE AT 125%. SHOWS 30AMP | | | ON 10KW HEAT WHICH IS NOT PERMITTED. | | | PLEASE ALSO COORDINATE THE AHU HEAT ON CALCULATIONS | | | WITH THE MECHANICAL PLANS AS MECHANICAL SHOWS 10KW AND | | | ELECTRICAL CALCULATIONS SHOWS 8KW AND 9KW. | | | | | | 2) NOTE: PLEASE INCLUDE DETAILS FOR GROUNDING ELECTRODE | | | SYSTEM.PLEASE SEE 250.50, 250.56, 250.52(5) PLEASE | | | INCLUDE 2-GRND RODS, AND COLD WATER PIPE (METAL). | | | MAY NOT QUOTE 250 AS GENERAL IN LIEU OF DETAILS. | | | | | | 3) NOTE: PLEASE INCLUDE THE ACTUAL AIC RATING OF MAIN. | | | PLANS INCLUDE A LETTER FROM FPL WHICH GIVES AVAILABLE | | | FAULT CURRENT HOWEVER THIS DOES NOT GIVE THE RATING OF | | | WHAT THE MAINS/EQUIPMENT WILL BE. THE SELECTION OF THE | | | AIC OF EQUIPMENT IS DETERMINED FROM THE AVAILABLE FAULT | | | CURRENT HOWEVER THE SELECTION IS NOT DONE BY FPL. | | | 110.9 | | | FBC 106.1.2 | | | | | | 4) NOTE: PLEASE SEE PREVIOUS NOTES WITH RESPECT TO | | | DINING ROOM LOADS. THE PANEL SCHEDULE SHOWS TWO | | | DEDICATE CIRCUITS WHICH REQUIRES THE LOAD TO BE FIGURED | | | FOR DINING ROOM RECEPTACLE CIRCUITS ARE TO BE FIGURED | | | IN ADDITION TO THE TWO SMALL APPLIANCE CIRCUITS. | | | 210.52B1, 210.11C1, 220.53 | | | | | | 5) NOTE: PLEASE SEE MECHANICAL REVIEW COMMENTS WITH | | | RESPECT TO RETURN AIR. | | | ELECTRICAL PLANS SHOWS AHU BEING OPEN TO CLOSET YET THE | | | OTHER TWO SHEETS SHOWS THE AHU AS CLOSED IN. | | | PLEASE KNOW THAT THE AHU MAY NOT CONTAIN OVER CURRENT | | | PROTECTION IN A CLOSET IN CLOSE PROXIMITY TO EASILY | | | IGNITABLE MATERIALS. | | | 240.24, 110.26 | | | | | | 6) NOTE: PLEASE SEE THE LOAD FOR THE DISPOSAL IS NOT | | | FIGURED INTO THE LOAD CALCULATIONS. THIS CIRCUIT IS | | | SHOWN ON PANEL SCHEDULE. | | | 220 | | | PLEASE ALSO SEE THE KITCHEN ELECTRICAL PLANS DO NOT | | | INCLUDE THE RECEPTACLE FOR THIS DISPOSAL. WILL IT BE | | | SWITCHED? OR SELF STARTING? | | | | | | 7) NOTE: PLEASE COORDINATE THE SUB PANELS AS THE RISER | | | SHOWS THESE A MLO WHICH IS CORRECT AND THE PANEL | | | SCHEDULES SHOW THESE AS MDO? | | | SEEMS TO BE A MISPRINT. | | | FBC 106.1.2 FOR COORDINATION. | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-11-09 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-11-09 |
Time |
16:12 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-11-09 |
Time |
16:12 |
Sent To |
M |
|
| Notes |
| 2007-11-09 16:12:45 | ** DENIED 2ND REVIEW ** | | | | | | ** PLEASE SEE SOME CODE SECTIONS FROM PREVIOUS REVIEW | | | ARE STILL IN NEED OF ADDRESSING. | | | PLEASE ALSO SEE SEVERAL NEW COMMENTS DUE TO NEW PLANS | | | BEING SUBMITTED FOR REVIEW. | | | | | | 1) NOTE:PLEASE REFERENCE ALL CODES ON PLANS AS | | | PREVIOUSLY STATED AND REQUIRED BY FBC. | | | 2004 FBC/W2006 REVISIONS. | | | 2005 NFPA-70 | | | 2002 NFPA-72 | | | 2003 NFPA-101 | | | | | | 2) NOTE: PLEASE KNOW THAT INFORMATION AND PAPER | | | DOCUMENTATION MAY NOT BE TAPED ONTO PLANS. | | | PLEASE COPY AND PRINT SHEETS. | | | PLEASE BE SURE THE PRINTED NAME AND SIGNATURE OF THE | | | PERSON TAKING RESPONSIBILITY FOR PLANS IS DONE ON NEW | | | SHEETS. | | | FBC 106.1.2, 106.5 | | | | | | 3) NOTE: PLEASE SEE PLANS ARE MISSING RECEPTACLES PER | | | 210.52. | | | FOR EXAMPLE: WALL SPACES IN KITCHEN. | | | | | | 4) NOTE: PLEASE SEE 210.52B1, 210.11C2, 220.53 AS 1500 | | | VA IS REQUIRED FOR ONE OR MORE OF THE SMALL APPLIANCE | | | CIRCUITS. THIS COMMENT IS FOR THE DINIGN ROOM | | | CIRCUITED. | | | | | | 5) NOTE: PANEL SCHEDULE SHOWS JACUZZI TUB GFI CIRCUIT | | | YET PLANS DO NOT SHOW ANY ELECTRICAL. | | | THIS IS THE SAME FOR OTHER ITEMS WHICH ARE MISSING | | | ELECTRICAL OUTLETS/RECEPTACLES ON PLANS. | | | WASHER, DRYER, DISHWASHER ETC. | | | PLEASE COMPLETE PLANS WITH ALL ELECTRICAL FOR MINIMUM | | | NEC COMPLIANCE AND ELECTRICAL WHICH IS LISTED ON PANEL | | | SCHEDULE. | | | FBC 106.3.5.4 | | | | | | 6) NOTE: PLEASE SEE 210.52D, 210.11C3 AS ALL DEDICATED | | | BATH RECEPTACLE CIRCUITS SHALL BE 20AMP AND #12 AWG. | | | PANEL SCHEDULE SHOWS 15AMP BREAKERS. | | | | | | 7) NOTE: PLEASE SEE 230.70, AS NO MORE THAN 8FT OF | | | UNPROTECTED CONDUCTORS ARE PERMITTED INSIDE DWELLING. | | | PLEASE KNOW AS THIS IS AN EXISTING DWELLING, THESE | | | WOULD NOT BE IN THE SLAB AND BASED ON LOCATION AND | | | SCALE ON PLANS, A MAIN WITH OCP WOULD BE REQUIRED | | | OUTSIDE. | | | THE OTHER OPTION WOULD BE TO RELOCATE PANEL FROM | | | LOCATION SHOWN TO DECREASE UNPROTECTED CONDUCTOR | | | LENGTH. | | | | | | 8) NOTE: PLEASE SUBMIT REVISED COMPLETED PLANS. | | | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTIONS SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-05-17 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-05-17 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-05-17 |
Time |
14:31 |
Sent To |
M |
|
| Notes |
| 2007-05-17 14:43:22 | ** UNSAT ** | | | | | | ** PLEASE SEE REFERENCES TO CHAPTER 1 OF THE FLORIDA | | | BUILDING CODE IS THE ADMINISTRATIVE SECTION AS ADOPTED | | | BY THE CITY OF WEST PALM BEACH. | | | | | | | | | | | | 1) NOTE:PLEASE SEE PLANS MUST REFLECT CURRENT CODES | | | IN EFFECT AND ADOPTED BY THE STATE IN THE SCOPE OF WORK | | | AS SHOWN. | | | PLEASE KNOW HOWEVER AT THIS TIME AND AS OF DECEMBER | | | 8TH, 2006 THE STATE IS UNDER THE 2004 FBC W/2006 | | | REVISIONS. THESE ARE ONLY REVISIONS TO THE 2004 FBC. | | | SOME OF THESE ARE STATED ON ELECTRICAL HOWEVER SHOULD | | | ALSO BE ON COVER SHEETS. | | | WE ARE UNDER THE 2005 NFPA-70. (NEC). | | | PLEASE ALSO LIST THE FOLLOWING. | | | 2002 NFPA-72 | | | | | | 2) NOTE: PLEASE SEE FBC R313 AS THE EXISTING DWELLING | | | IS REQUIRED TO BE BROUGHT UP TO CODE OR THE EXISTING IS | | | TO SHOW MEETING THE CURRENT CODE FOR SMOKE | | | DETECTION/SOUNDING DEVICES. PLEASE SHOW A LAYOUT OF THE | | | EXISTING DWELLING WHICH WILL REQUIRE SMOKE DEVICES | | | INSIDE AND OUTSIDE ALL BEDROOMS AND ON EACH LEVEL IF A | | | MULTI-LEVEL BUILDING. | | | PLEASE SHOW THE SMOKE DEVICES AS SA OR SD DEPENDING ON | | | THE TYPE OF DEVICE. PLEASE SEE THE DEFINITIONS IN | | | NFPA-72 OR CALL TO GO OVER. | | | NFPA-72 11.5.1.1, 11.8.3 | | | | | | 3) NOTE: PLEASE SUBMIT COMPLETED PLANS FOR 2005 NEC | | | COMPLIANCE: | | | PLEASE COMPLETE RISER WITH ALL MINIMUM CONDUCTOR | | | SIZES. | | | PLEASE INDICATE ALL OVER CURRENT PROTECTION DEVICES FOR | | | SERVICE AND BRANCH CIRCUITS. | | | PLEASE SUBMIT A COMPLETED PANEL SCHEDULE SHOWING ALL | | | MINIMUM REQUIRED CIRCUITS AND OTHER DEDICATE CIRCUITS | | | PER NEC. | | | PLEASE COMPLETE PLANS WITH ALL ELECTRICAL. | | | PLEASE COMPLETE KITCHEN LAY OUT. | | | PLEASE SHOW ALL DISCONNECT LOCATIONS. | | | PLEASE SUBMIT AIC RATINGS FOR NEW SERVICE EQUIPMENT. | | | PLEASE COMPLETE CORRECT GROUNDING ELECTRODE SYSTEM. | | | PLEASE COMPLETE FIXTURE LEGEND AND EGRESS LIGHT. PLEASE | | | SUBMIT COMPLETED LOAD CALCULATIONS. | | | PLEASE SEE FBC CHAPTER 13 FOR ENERGY EFFICIENCY | | | COMPLIANCE FOR ANY RECESSED LIGHTING FIXTURES AND ALSO | | | FOR A/C WORK ETC. SEE MECH REVIEW COMMENTS. 210.8A, | | | 210.52,210.11,220, 230, 240, 440,422, 424, 210.70 | | | 310.16 ETC. | | | ** PLEASE KNOW THERE ARE TOO MANY ITEMS MISSING FOR A | | | CODE COMPLIANT REVIEW. PLEASE COMPLETE AS NOT | | | EVERYTHING AS MENTIONED ABOVE IS ALL REQUIRED PER | | | MINIMUM CODE. | | | | | | 4) NOTE: PLEASE KNOW THAT PLANS MUST BE SUBMITTED IN A | | | MINIMUM 1/8 SCALE, DRAFTSMAN?S QUALITY, MAY NOT BE IN | | | PEN OR PENCIL. | | | MUST CONTAIN PRINTED NAME AND SIGNATURE FROM THE DESIGN | | | PROFESSIONAL. | | | FS 481.229, 471.003 | | | FBC 106.1.3, 106.1.2, 106.3.5.4 | | | | | | 5) NOTE:VALUE FOR COMPLETE SCOPE OF WORK MUST INCLUDE | | | FAIR MARKET VALUE AND INCLUDE ALL LABOR AND MATERIALS | | | EVEN IF OWNER SUPPLIED AND NO COST FOR LABOR AS OWNER | | | CONSTRUCTED. | | | FBC 108.3 | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2008-04-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-10 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-10 |
Time |
08:50 |
Sent To |
E |
|
| Notes |
| 2008-04-10 08:50:40 | TO "DPALMER" DESK/-NEW SHEETS ALL TRADES |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-02-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-02-20 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-02-20 |
Time |
16:51 |
Sent To |
E |
|
| Notes |
| 2008-02-20 16:51:35 | TO "E" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-11-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-08 |
Time |
11:04 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-08 |
Time |
11:04 |
Sent To |
E |
|
| Notes |
| 2007-11-08 11:04:34 | TO "DPALMER" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-06-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-06-27 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-05-14 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2007-05-14 15:11:48 | TO "SFR" "E" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2008-04-11 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-04-11 |
Time |
09:40 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-04-11 |
Time |
09:40 |
Sent To |
P |
|
| Notes |
| 2008-04-11 09:41:47 | 1/2 DOOR ABOVE RETURN AIR GRILL FOR SERVICE, PER GENE | | | S. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-03-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-03-03 |
Time |
11:05 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2008-03-03 |
Time |
11:04 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-11-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-11-13 |
Time |
08:13 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-11-13 |
Time |
08:13 |
Sent To |
P |
|
| Notes |
| 2007-11-13 08:27:06 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) THE MAIN TRUNK LINE (DUCT) STILL NEEDS TO BE SIZED, | | | (SEE YELLOW HIGH LIGHT ON MECHANICAL PLAN), SEE WPB | | | AMEND. 106.3.5.4 (10). | | | | | | 2) THE RETURN AIR TRANSFER DUCT STILL NEEDS TO BE | | | SIZED, (SEE YELLOW HIGH LIGHT ON MECHANICAL PLAN), SEE | | | FBC/R M1602.4. | | | | | | 3) SHOW THE MANUFACTURER'S NAME OF THE A/C SYSTEM ON | | | THE PLAN. | | | | | | 4) SHOW THE HEATER KW ON THE PLAN IF ONE IS TO BE | | | INSTALLED. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-05-21 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-05-21 |
Time |
10:27 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-05-21 |
Time |
10:27 |
Sent To |
P |
|
| Notes |
| 2007-05-21 10:33:46 | *** DENIED *** | | | 1) PLEASE SHOW SIZE OF ALL SUPPLY AIR TRUNK LINES | | | (DUCTS). | | | | | | 2) PLEASE SHOW CFM'S. AT ALL SUPPLY AIR GRILLS. | | | | | | 3) PLEASE SHOW SIZE OF RETURN AIR TRANSFER DUCT AND | | | GRILLS. | | | | | | 4) ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE PRINTED NAME AND | | | SIGNATURE OF THE PERSON RESPONSIBLE FOR THE DESIGN. PER | | | FBC 104.2.1 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2008-04-14 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-04-14 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-04-14 |
Time |
16:08 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2008-03-03 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-03-03 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-03-03 |
Time |
16:07 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-11-14 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-11-14 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-11-14 |
Time |
13:25 |
Sent To |
B |
|
| Notes |
| 2007-11-14 13:41:09 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODES WITH | | | 05 & 06 REVISIONS, CITY OF WEST PALM BEACH AMENDMENTS | | | TO CHAPTER 1 (W.P.B.), FLORIDA ADMINISTRATIVE CODE | | | (F.A.C.), AND FLORIDA STATUTES (F.S.). | | | | | | PLUMBING PLAN REVIEW: | | | DENIED 2ND TIME: | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE. | | | | | | 1. NOTE: PER THE PLUMBING "COMMENTS RESUBMITTALS" | | | PLEASE CLEARLY INDICATE ON FLOOR PLAN SHEET E-1REV | | | EXACTLY WHAT IS BEING REPLACED. PER *106.1.2, | | | ADDITIONAL INFORMATION REQUIRED. | | | | | | 2. FBC-2004 CHAPTER 1,SECTION 106.3.4.3: | | | THE PERSON RESPONSIBLE FOR THE DESIGN OF | | | THE DRAWING SHALL CLEARLY PRINT AND SIGN | | | NAME, AND ALSO DATE DRAWING. PLEASE DO | | | THIS PRIOR TO RESUBMITTING. | | | **NOTE: THIS IS REQUIRED FOR THE SANITARY ISOMETRIC | | | RISER DIAGRAM ATTACHED TO SHEET A/C. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-06-05 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-06-05 |
Time |
09:50 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2007-06-05 |
Time |
09:50 |
Sent To |
B |
|
| Notes |
| 2007-06-05 10:22:52 | DENIED | | | REFERENCE: | | | ** FBC-2004 PLUMBING. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4 | | | RESIDENTIAL (ONE AND TWO-FAMILY) PLEASE SUBMIT A | | | PLUMBING SANITARY ISOMETRIC RISER DIAGRAM INDICATING | | | ALL WASTE, VENTS, TRAPS AND SIZES WITH CLEANOUT | | | LOCATIONS. | | | NOTE: THE SUBMITTED PLUMBING RISER IS NOT A SANITARY | | | ISOMETRIC RISER DIAGRAM, DOES NOT REFLECT THE FLOOR | | | PLAN AND NOT ALL PIPING IS SIZED. PLEASE REFERENCE THE | | | ATTACHED SANITARY ISOMETRIC RISER DIAGRAM TO THE | | | PLUMBING COMMENTS THAT IS CODE COMPLIANT AND REFLECTS | | | THE FLOOR PLAN FOR THE RESUBMITTAL. | | | | | | 2. PER FBC-2004 PLUMBING, SECTION 1002.1 A FIXTURE | | | SHALL NOT BE DOUBLE TRAPPED. A WATER CLOSET HAS AN | | | INTREGRAL TRAP THEREFORE A TRAP IS NOT REQUIRED FOR THE | | | SANITARY ISOMETRIC RISER DIAGRAM. | | | | | | 3. FBC-2004 CHAPTER 1,SECTION 106.3.4.2: | | | THE PERSON RESPONSIBLE FOR THE DESIGN OF | | | THE DRAWING SHALL CLEARLY PRINT AND SIGN | | | NAME, AND ALSO DATE DRAWING. PLEASE DO | | | THIS PRIOR TO RESUBMITTING. | | | | | | 4. PER FBC-2004, CHAPTER 1, SECTION | | | 108.3, BUILDING PERMIT VALUATION: IF IN | | | THE OPINION OF THE BUILDING OFFICIAL, | | | THE CLAIMED VALUATION OF THE BUILDING, | | | ALTERATION, STRUCTURE, ELECTRICAL, GAS | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS | | | TO BE UNDERESTIMATED ON THE APPLICATION, | | | THE PERMIT SHALL BE DENIED. FOR | | | PERMITTING PURPOSES, VALUATION OF | | | BUILDINGS AND SYSTEMS SHALL BE TOTAL | | | REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR | | | FINISH, NORMAL SITE WORK (EXCAVATION AND | | | BACKFILL FOR BUILDINGS), ARCHITECTURAL | | | AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND | | | VALUE. VALUATION REFERENCES MAY INCLUDE | | | THE LATEST PUBLISHED DATA OF NATIONAL | | | CONSTRUCTION COST ANALYSIS SERVICES (MARSHALL-SWIFT, | | | MEANS ECT.) WITH | | | REGIONAL ADJUSTMENTS FOR LOCATION AS | | | PUBLISHED BY INTERNATIONAL CODE | | | CONGRESS. | | | | | | ********IMPORTANT INFORMATION******** | | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. | | | NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|