Plan Review Details - Permit 07040508
Plan Review Stops For Permit 07040508
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-06-05 Cont ID  
Sent By amorse Date 2007-06-05 Time 18:35 Rev Time 0.00
Received By amorse Date 2007-06-05 Time 18:35 Sent To PC
Notes
2007-06-05 18:44:31 
  
 DENIED
  
 1)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SETS OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561) 233-5025 FOR MOREINFORMATION.
  
 2)THE STATE OF FLORIDA REQUIRES COLLECTION OF A RADON
 SURCHARGE ON ALL NEW CONSTRUCTION COMPUTED ON UNDER
 ROOF FLOOR SPACE PER 10D-91 FAC. THESE FEES WILL BE
 ADDED TO THE PERMIT APPLICATION FEES AND $2.82 IS DUE.
  
 3)THE CLAIMED VALUATION ON THE PERMIT APPLICATION IS
 LOW. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS
 AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT COST
 EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC
 (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES
 PER 108.3 FBC*
  
 4)PROVIDE SITE PLAN 2 COPIES OF A RECENT SURVEY
 SHOWING THE PROPOSED BUILDING/ADDITION WITH ALL SIDE
 AND REAR SETBACKS
  
 5)THE PERMIT APPLICATION SHALL INCLUDE TWO COPIES OF
 EACH PRODUCT APPROVAL THAT
 IS RELEVANT PER 9B-72. THESE SHOULD INCLUDE THE FLORIDA
 STATE APPROVAL COVER PAGES, AND THE PRODUCT NOA THAT
 LISTS THE SYSTEM COMPONENTS/ FASTENER LIST PAGES, THE
 PAGES WITH THE CHOSEN ASSEMBLY/ SYSTEM TO BE USED AND
 THE GENERAL LIMITATIONS PAGE. ALL CAN BE FOUND ON
 WWW.FLORIDABUILDING.ORG
  
 6)THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE
 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR
 JURISDICTIONAL APPROVAL PER 106.3.3 FBC*
  
 7)THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA
 STATE PRODUCT APPROVAL COVER
 SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON
 WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT
 SUBMITTED APPLICATIONS WILL BE DENIED
  
 8)SUBMIT ENERGY CALC'S PER 13-101.2.2
 FBC. BE SURE THAT THEY ARE SIGNED AND
 DATED BY PREPARER AND OWNER/AGENT PRIOR
 TO SUBMITTAL
  
 9)SUBMIT 2 COPIES OF ENGINEERED TRUSS DRAWINGS THAT
 COMPLY WITH R802.10.1 FBC WITH PERMIT APPLICATION OR
 BEFORE INSTALLATION THAT HAVE BEEN REVIEWED AND
 APPROVED BY THE DESIGNER OF RECORD
  
 10)THE FOLLOWING ARE REQUIRED ON THE DRAWINGS
 A)BUILDING ELEVATION TO INCLUDE MEAN ROOF HEIGHT AND
 ROOF PITCH
 B)PROVIDE MIN ROOF SHEATHING ATTACHMENT
 PER R803.2.3.1 FBC RES.
 C)PROVIDE INFORMATION ON EXISTING BUILDING, SURVEY
 SHOWS EXISTING TO BE CBS DRAWINGS SHOW NEW AS WOOD
 FRAME. WHAT ATTACHMENT METHODWILL BE USED FOR WALLS
 AND IS THE EXISTING FLOOR WOOD ON STRIP FOOTING OR SLAB
 ON GRADE
 D)PROVIDE DETAIL ON LVL BEAM ELEVATION AND ATTACHMENT
 AT EXTERIOR WALL. IS BEAM FLUSH TO CEILING WITH HANGERS
 FOR EXISTING ROOF MEMBERS OR DROPPED WITH EXISTING ROOF
 ON TOP
 E)PROVIDE FLORIDA STATE APPROVAL #'S FOR ANCHORS AND
 TIES IN THE TRUSS ANCHOR SCHEDULE OR PROVIDE PRODUCT
 APPROVALS
 F)PROVIDE A COMPLETE WALL SECTION FOOTING THROUGH
 ROOF, TO INCLUDE INSULATION VALUES THAT MATCH ENERGY
 CALC'S, ROOF SHEATHING ATTACHMENT IF NOT ANYWHERE
 ELSE,ETC.
  
 11)A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-04-27 Cont ID  
Sent By btrobaug Date 2007-04-27 Time 07:23 Rev Time 0.50
Received By btrobaug Date 2007-04-27 Time 06:32 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-04-26 Cont ID  
Sent By adarroug Date 2007-04-26 Time 09:00 Rev Time 0.00
Received By adarroug Date 2007-04-26 Time 09:00 Sent To E
Notes
2007-04-26 09:00:29TO "SFR" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-06-05 Time   Rev Time 0.00
Received By adarroug Date 2007-04-17 Time 16:12 Sent To  
Notes
2007-04-17 16:12:59TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-04-30 Cont ID  
Sent By tgordon Date 2007-04-30 Time 08:40 Rev Time 0.20
Received By tgordon Date 2007-04-30 Time 08:40 Sent To P
Notes
2007-04-30 08:45:25*** DENIED ***
 1) MECHANICAL PERMIT #07040521 HAS BEEN APPLIED FOR BUT
 NO MECHANICAL PLANS WERE SUBMITTED FOR REVIEW. PLEASE
 SUBMIT MECHANICAL PLANS FOR REVIEW, PER 2004 FBC CITY
 OF WPB AMEND. 106.3.5.4 (10).
  
 2) PLEASE SUBMIT ENERGY CALCULATIONS, SEE 2004 FBC
 13-101.2.2.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-05-04 Cont ID  
Sent By jleech Date 2007-05-04 Time 08:26 Rev Time 0.00
Received By jleech Date 2007-05-04 Time 08:26 Sent To B
Notes
2007-05-04 08:45:07DENIED;
 1.SANITARY RISER DIAGRAM, PAGE E-1; WATER HEATER IS NOT
 PART OF THE DRAINAGE SYSTEM. REMOVE FROM RISER
 DIAGRAM.
 2. THE BRANCH DRAIN FOR AUTOMATIC CLOTHES WASHER SHALL
 BE 3" SEE SECTION 406.3.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695

Review Stop Z ZONING
Rev No 1 Status F Date 2007-04-25 Cont ID  
Sent By jroach Date 2007-04-25 Time 17:36 Rev Time 0.00
Received By jroach Date 2007-04-25 Time 17:36 Sent To I
Notes
2007-04-25 17:38:07***FAILED***
  
 1) AN OVERALL SITE PLAN SHALL BE PROVIDED SHOWING THE
 LOCATION OF THE EXISTING STRUCTURE, AS WELL AS THE
 PROPOSED ADDITION, RELATIVE THE PROPERTY LINES.
  
 2) SETBACKS FROM THE PROPERTY LINES (SIDE AND REAR)
 SHALL BE PROVIDED ON THE SITE PLAN AND ON THE SURVEY.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER,
 AT (561) 822-1435.