| Plan Review Stops For Permit 07040420 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-09-07 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-09-07 |
Time |
06:26 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-09-06 |
Time |
12:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-07-20 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-07-20 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-07-20 |
Time |
07:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-06-16 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-06-16 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-06-16 |
Time |
07:39 |
Sent To |
|
|
| Notes |
| 2007-06-16 10:00:43 | BUILDING PLAN REVIEW | | | PERMIT: 0704042 | | | ADD: 222 LAKEVIEW AVE #1700 | | | CONT: PASS INTERNATIONAL | | | TEL: (954)421-9000 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 2ND | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | 2)THE TITLE BLOCK SHALL INDICATE THE CERTIFICATE OF | | | AUTHORIZATION NUMBER OF THE ARCHITECTURAL FIRM. FLORIDA | | | STATUTES 481.221(2)ALL FINAL CONSTRUCTION DOCUMENTS | | | AND INSTRUMENTS OF SERVICE WHICH INCLUDE DRAWINGS, | | | PLANS, SPECIFICATIONS, OR REPORTS PREPARED OR ISSUED BY | | | THE REGISTERED ARCHITECT AND BEING FILED FOR PUBLIC | | | RECORD SHALL BEAR THE SIGNATURE AND SEAL OF THE | | | REGISTERED ARCHITECT WHO PREPARED OR APPROVED THE | | | DOCUMENT AND THE DATE ON WHICH THEY WERE SEALED. THE | | | SIGNATURE, DATE, AND SEAL SHALL BE EVIDENCE OF THE | | | AUTHENTICITY OF THAT TO WHICH THEY ARE AFFIXED. NOTE: | | | ALL INFORMATION ON THE SEAL SHALL BE LEGIBLE ON EACH | | | SHEET. CHECK ALL PAGES FOR CLARITY OF THE SEAL. | | | | | | 3)ON SHEET A3.1 DETAIL L10 SHOWS DOORS IN FRONT OF | | | THE SINK. THE DOORS SHALL BE REMOVED TO PROVIDE THE | | | FORWARD APPROACH FOR ACCESSIBILITY.SEE FBC 11-4.24. | | | | | | 4)SHOW IN DETAIL HOW THE RECPTIONIST AREA/COUNTER | | | WILL MEET THE REQUIREMENTS OF SECTION 11-7. A PORTION | | | OF THE MAIN COUNTER SHALL BE 36 INCHES LONG AND 36 | | | INCHE HIGH. | | | | | | 5)THE ROOM NEXT TO #3 INTERVIEW ROOM, WILL A DOOR BE | | | INSTALL OR WILL IT BE AN OPENING. SHOW THE DIMENTION OF | | | THE OPENING ON THE PLANS OR THE SWING OF THE DOOR. | | | | | | 6)ALL DRINKING FOUNTAINS AND WATER COOLERS SHALL MEET | | | THE REQUIREMENTS OF 11-4.15 AND FIGURE 27. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-04-23 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-04-23 |
Time |
10:53 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-04-23 |
Time |
07:34 |
Sent To |
|
|
| Notes |
| 2007-04-23 12:12:15 | BUILDING PLAN REVIEW | | | PERMIT: 07040420 | | | ADD: 222 LAKEVIEW AVE | | | CONT: PASS INTERNATIONAL INC. | | | TEL: (954)421-9000 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 1ST | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2)FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF | | | THE COURT. | | | NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS | | | NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE | | | RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: | | | 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT | | | THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3)THE EXISTING ROOM NEXT TO INTERVIEW #3 NEEDS A | | | DOOR, UNLESS THIS AREA WILL BE CLOSED OFF. SHOW THE | | | EXTENSION OF THE NEW WALL EXTENDING FROM INTERVIEW ROOM | | | #2 TO THE EXTERIOR WALL. SEE THE DEMO SHEET D1.1 AND | | | A1.1. | | | 106.1.1 CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT | | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | | TE WORK PROPOSED. | | | | | | 4)481.221 IF PRACTICING THROUGH A DULY AUTHORIZED | | | BUSINESS, INDICATE THE CERTIFICATE OF AUTHORIZATION | | | NUMBER ON THE TITLE BLOCK. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-09-10 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-09-10 |
Time |
07:20 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-09-10 |
Time |
06:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-07-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-07-19 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-07-18 |
Time |
16:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-06-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-06-13 |
Time |
16:44 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2007-06-13 |
Time |
16:11 |
Sent To |
|
|
| Notes |
| 2007-06-13 16:44:39 | | | | | | | | | | | | | | | | NONCOMPLIANT | | | | | | THE ENGINEER WHOSE NAME APPEARS ON THE TITLE BLOCK MUST | | | SIGN, DATE AND SEAL THE DOCUMENT. 61G15-23.002 FAC. THE | | | SEAL IS INDISCERNIBLE. ALSO MUST PROVIDE A TITLE | | | BLOCK. | | | | | | A SEPARATE LOW VOLTAGE PERMIT IS REQUIRED FOR THE | | | ACCESS CONTROL SYSTEM, SPECIFICATIONS FOR ALL DEVICES | | | AND EQUIPMENT MUST BE SUBMITTED WITH THE LOW VOLTAGE | | | APPLICATION. TWO COPIES OF THIS SHEET, SIGNRD AND | | | SEALED MUST BE SUBMITTED WITH THAT APPLICATION FOR | | | RECORD RETENTION. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-04-17 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-04-17 |
Time |
14:10 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2007-04-17 |
Time |
11:24 |
Sent To |
|
|
| Notes |
| 2007-04-17 14:00:12 | | | | | | | NONCOMPLIANT | | | | | | THE ENGINEER WHOSE NAME APPEARS ON THE TITLE BLOCK MUST | | | SIGN, DATE AND SEAL THE DOCUMENT. 61G15-23.002 FAC. THE | | | SEAL IS INDISCERNIBLE. | | | | | | THE 2005 NEC WAS ADOPTED BY THE FLORIDA LEGISLATURE | | | EFFECTIVE 8 DECEMBER 2006. THE APPLICATION FOR THIS | | | PROJECT WAS AFTER THAT DATE AND THE PLANS ARE SUBJECT | | | TO THAT CODE. PLEASE CHANGE ALL NOTES TO REFLECT THIS | | | CHANGE. | | | | | | A SEPARATE LOW VOLTAGE PERMIT IS REQUIRED FOR THE | | | ACCESS CONTROL SYSTEM, SPECIFICATIONS FOR ALL DEVICES | | | AND EQUIPMENT MUST BE SUBMITTED WITH THE LOW VOLTAGE | | | APPLICATION. TWO COPIES OF THIS SHEET, SIGNRD AND | | | SEALED MUST BE SUBMITTED WITH THAT APPLICATION FOR | | | RECORD RETENTION. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2007-09-25 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-09-25 |
Time |
19:18 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-09-25 |
Time |
18:57 |
Sent To |
|
|
| Notes |
| 2007-09-25 19:18:27 | *****APPROVED***** | | | | | | | | | REVISED PLAN SHEETS A1.1 AND E-2 WERE STAMPED, | | | INITIALED, AND DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-07-20 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-07-20 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-07-20 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2007-07-20 15:19:53 | PLANS APPROVED ON 6/20/07 AND STAMPED ON 7/20/07. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-06-20 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-06-20 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-06-20 |
Time |
12:31 |
Sent To |
|
|
| Notes |
| 2007-06-20 12:43:37 | *****PROVISO***** | | | | | | ALL COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW APPEAR | | | TO HAVE BEEN ADDRESSED, HOWEVER, THE APPROPIATE PLAN | | | SHEET(S) WILL BE STAMPED WHEN ALL OTHER PLAN REVIEWS | | | HAVE BEEN SATISFIED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-04-18 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-04-18 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-04-18 |
Time |
14:13 |
Sent To |
|
|
| Notes |
| 2007-04-18 14:18:19 | ***DENIED*** | | | | | | 1) PLEASE CLARIFY CODE REFERENCE, NFPA 101 27-33. SHT | | | A4.1 | | | | | | 2) DOORS SHALL COMPLY WITH NFPA 101, SEC. 7.2.1. SHT | | | A4.1. | | | | | | 3) SEPARATE SHOP DRAWINGS AND PERMITS REQUIRED FOR FIRE | | | SPRINKLER AND FIRE ALARM REMODEL. | | | | | | 4) PLEASE PROVIDE MANUFACTURER SPEC SHEETS, MORE | | | INFORMATION AND DETAILS REGARDING ACCESS CONTROL | | | SYSTEM. SPECIAL LOCKING ARRANGEMENTS TO COMPLY WITH | | | NFPA 101, SEC. 7.2.1.6. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-09-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-09-17 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-09-17 |
Time |
15:12 |
Sent To |
M |
|
| Notes |
| 2007-09-17 15:13:13 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-08-27 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-27 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-27 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2007-09-04 10:59:08 | TO "BOB"#7 | | 2007-08-27 09:16:55 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-07-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-03 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-03 |
Time |
15:42 |
Sent To |
|
|
| Notes |
| 2007-07-09 15:42:56 | TO "BOB"#18 | | 2007-07-03 15:42:38 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-06-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-04 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-04 |
Time |
10:24 |
Sent To |
|
|
| Notes |
| 2007-06-05 14:45:50 | TO "BOB"#18 | | 2007-06-04 10:24:14 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-04-24 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-04-24 |
Time |
07:37 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-04-13 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2007-04-16 16:36:32 | TO "BOB"#12 | | 2007-04-13 16:29:36 | WAITING FOR "BOB" |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-09-18 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-09-18 |
Time |
09:48 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-09-18 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2007-09-18 09:49:19 | REVISION TO MECH. PLANS PAGE M1. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-09-07 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-09-07 |
Time |
10:53 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-09-07 |
Time |
10:53 |
Sent To |
|
|
| Notes |
| 2007-09-07 10:56:24 | REVISION TO MECH. PLANS PAGES M1 AND M2. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-07-10 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-10 |
Time |
10:52 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-07-10 |
Time |
10:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-06-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-06-12 |
Time |
15:27 |
Rev Time |
1.20 |
| Received By |
tgordon |
Date |
2007-06-12 |
Time |
15:27 |
Sent To |
|
|
| Notes |
| 2007-06-12 15:36:13 | *** DENIED *** | | | *** THE FOLLOWING COMMENTS APPLY TO ALL THE PAGES OF | | | THE SET OF PLANS. | | | 1) AS NOTED IN THE LAST REVIEW 4-17-07. INFORMATION | | | MISSING IN TITLE BLOCK FOR ARCHITECT (ARCHITECT FIRM | | | LICENSE NUMBER), SEE FAC 61G1-16.004 TITLE BLOCK. A | | | TITLE BLOCK MUST APPEAR ON ALL ARCHITECTURAL OR | | | INTERIOR DESIGN DRAWINGS AND SPECIFICATION | | | IDENTIFICATION SHEETS. THE TITLE BLOCK MUST, AT A | | | MINIMUM, CONTAIN THE FOLLOWING INFORMATION: | | | (1) FIRM NAME, ADDRESS, AND TELEPHONE NUMBER. | | | (2) FIRM LICENSE NUMBER. | | | (3) NAME OR IDENTIFICATION OF PROJECT. ("JOB ADDRESS" | | | SEE CITY WPB AMEND. 106.1.1). | | | (4) DATE PREPARED. | | | (5) A SPACE FOR THE SIGNATURE AND DATED SEAL. | | | (6) A SPACE FOR THE PRINTED NAME OF THE PERSON SEALING | | | THE DOCUMENT. | | | | | | 2) ARCHITECT FIRM LICENSE NUMBER FOR YOSHINO | | | TRIESCHMANN DESIGN GROUP EXPIRED 2-28-07 AND CLOSED, | | | SEE ATTACHED LICENSE INFORMATION, PLEASE CORRECT. *** | | | INTERIOR DESIGN BUSINESS LICENSE NUMBERS ADDED TO FRONT | | | SHEET WITH ARCHITECT SEAL IS NOT APPROPRIATE, PLEASE | | | CORRECT ARCHITECT FIRM LICENSE NUMBER OR YOU MAY REMOVE | | | THE DESIGN GROUP FROM ALL TITLE BLOCKS AND ADD ALL | | | PERTINENT INFORMATION FOR ARCHITECT TO TITLE BLOCK. | | | | | | 3) SEE ELECTRICAL REVIEW NOTE REGARDING SEAL,THIS | | | NOTE APPLIES TO ALL PAGES IN SET OF PLANS, PLEASE | | | CORRECT. | | | | | | 4) NEW COMMENT,SEE ATTACHED NOTICE FS 553.80(2)(B) | | | REGARDING FOUR TIMES THE FEE. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-04-17 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-04-17 |
Time |
15:21 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-04-17 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2007-04-17 15:29:20 | *** DENIED *** | | | 1) INFORMATION MISSING IN TITLE BLOCK FOR ARCHITECT | | | (FIRM LICENSE NUMBER), SEE FAC 61G1-16.004 TITLE | | | BLOCK. | | | A TITLE BLOCK MUST APPEAR ON ALL ARCHITECTURAL OR | | | INTERIOR DESIGN DRAWINGS AND SPECIFICATION | | | IDENTIFICATION SHEETS. THE TITLE BLOCK MUST, AT A | | | MINIMUM, CONTAIN THE FOLLOWING INFORMATION: | | | (1) FIRM NAME, ADDRESS, AND TELEPHONE NUMBER. | | | (2) FIRM LICENSE NUMBER. | | | (3) NAME OR IDENTIFICATION OF PROJECT. ("JOB ADDRESS" | | | SEE CITY WPB AMEND. 106.1.1). | | | (4) DATE PREPARED. | | | (5) A SPACE FOR THE SIGNATURE AND DATED SEAL. | | | (6) A SPACE FOR THE PRINTED NAME OF THE PERSON SEALING | | | THE DOCUMENT. | | | | | | 2) FIRM LICENSE NUMBER FOR YOSHINO TRIESCHMANN DESIGN | | | GROUP EXPIRED 2-28-07, PLEASE CORRECT. | | | | | | 3) SEE ELECTRICAL REVIEW NOTE REGARDING SEAL, PLEASE | | | CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-09-10 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-09-10 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-09-10 |
Time |
15:06 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-07-23 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-07-23 |
Time |
07:22 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-07-23 |
Time |
07:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-06-19 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-06-19 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-06-19 |
Time |
08:38 |
Sent To |
|
|
| Notes |
| 2007-06-19 09:02:25 | DENIED; | | | 1. BREAK SINK KNEE CLEARANCE NOT ADDRESSED. (SECOND | | | REQUEST) PAGE 3.1 DETAIL A-7 (BREAK SINK) CABINET DOORS | | | NOT PERMITED ON CABINET UNDER SINK. NO DOOR PERMITED TO | | | SWING INTO THE CLEAR FLOOR SPACE. THE LOCATION OF THE | | | SUMP PUMP MUST NOT LOCATED IN THE CLEAR FLOOR SPACE | | | UNDER THE BREAK SINK. SHOW LOCATION OF PUMP ON PLANS | | | WITH NOTE. | | | 2. PAGE D-1 NOTE 3, EXISTING CABINTRY, SINK AND PIPES | | | TO BE REMOVED. NO DEAD ENDS MORE THAN 2' PERMITED IN | | | THE SANITARY PLUMBING SYSTEM. | | | 3. COMMENTS BY ELECTRICAL AND MECHANICAL PLAN REVIEWS ( | | | ADMINISTRATION CODE PROBLEMS)MUST ALSO BE ADDRESSED. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-04-24 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-04-24 |
Time |
07:10 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-04-24 |
Time |
07:10 |
Sent To |
|
|
| Notes |
| 2007-04-24 07:36:26 | DENIED; | | | 1.PAGE 3.1 DETAIL A-7 (BREAK SINK) DOOR AND KICK PLAT | | | NOT TO CODE. SEE FBC-2004 BUILDING CHAPTER 11 HANDICAP | | | CODE SECTION 11-4.24.3, KNEE CLEARANCE REQUIRED UNDER | | | THE SINK, 27" HIGH 30" WIDE, AND 19" DEEP. PLEASE SHOW | | | A FRONT VIEW ON PLANS AND MAKE REFORANCE TO SECTIONS | | | 11-4.24.4, DEPTH OF SINK, 11-4.24.6 EXPOSED PIPES AND | | | 11-4.24.7 FAUSE TO BE LEVER OPERATED. | | | 2. PAGE D.1.1, KEY NOTE 3; ALL DELETED SANITARY AND | | | VENT PIPING MUST BE REMOVED SO NO DEAD ENDS ARE IN THE | | | SANITARY SYSTEM. FBC - 2004 PLUMBING SECTION 704.5 . | | | 3.THE SUBMITED DRAWINGS DO NOT SHOW A DRINKING FOUNTAIN | | | IN THE COMMON AREA. IF ONE DOES NOT EXIST THEN THE | | | WATER COOLER MUST BE A DRINKING FOUNTAIN WITH A DRAIN. | | | SEE TABLE 403.1 AND SECTION 410. THE DRINKING FOUNTAIN | | | OR COOLER MUST MEET H/C REQUIREMENTS. SUBMIT CUT SHEET | | | FOR WATER COOLER. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
N |
Date |
2007-07-19 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-07-19 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-07-19 |
Time |
17:20 |
Sent To |
|
|
| Notes |
| 2007-07-19 17:21:58 | *VALUE OF PROPOSED WORK DOES NOT EXCEED 50% OF THE | | | IMPROVEMENT VALUE. |
|
|