Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2007-05-02 Cont ID  
Sent By mjacobs Date 2007-05-02 Time 07:14 Rev Time 0.00
Received By mjacobs Date 2007-05-01 Time 12:34 Sent To PC
Notes
2007-05-02 07:20:12BUILDING PROVISO:
 TO BE IN PLACE AT C.O.:
  
 1) 424.2.17.1 OUTDOOR SWIMMING POOLS.
 OUTDOOR SWIMMING POOLS SHALL BE PROVIDED
 WITH A BARRIER COMPLYING WITH
 424.2.17.1.1 THROUGH 424.2.17.1.14.
  
 424.2.17.1.5 CHILD SAFETY BARRIER
 ASTM D5034 100 LB TENSILE STRNGTH
 ASTM D3787 150 LB BALL BURST
 STRENGTH
  
 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED.
 SPAS AND HEATED SWIMMING POOLS SHALL BE
 EQUIPPED WITH A COVER DESIGNED TO
 MINIMIZE HEAT LOSS.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-04-25 Cont ID  
Sent By btrobaug Date 2007-04-25 Time 07:25 Rev Time 0.00
Received By btrobaug Date 2007-04-25 Time 07:14 Sent To P
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2007-04-25 Cont ID  
Sent By mperson Date 2007-04-25 Time 11:48 Rev Time 0.00
Received By mperson Date 2007-04-25 Time 11:48 Sent To B
Notes
2007-04-25 11:50:41CONTRACTOR INFORMATION
 NOTE: GAS PERMIT REQUIRED. GAS CONTRAC-
 TOR TO SUBMIT PLANS WITH PERMIT APPLICA-
 TION. ALL GAS INSPECTIONS TO BE COMPLETE
 BEFORE FINAL GEN/RES INSPECTION.
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-05-04 Cont ID  
Sent By adarroug Date 2007-05-04 Time 13:40 Rev Time 0.00
Received By adarroug Date 2007-05-04 Time 13:40 Sent To Z
Notes
2007-05-04 13:40:31TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-04-13 Cont ID  
Sent By adarroug Date 2007-04-13 Time 14:32 Rev Time 0.00
Received By adarroug Date 2007-04-13 Time 14:32 Sent To E
Notes
2007-04-13 14:33:19TO "Z" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By jroach Date 2007-05-02 Time 16:57 Rev Time 0.00
Received By adarroug Date 2007-04-10 Time 14:14 Sent To  
Notes
2007-04-10 14:16:01TO "Z" BOX

Review Stop P PLUMBING
Rev No 1 Status P Date 2007-04-25 Cont ID  
Sent By mperson Date 2007-04-25 Time 11:45 Rev Time 0.33
Received By mperson Date 2007-04-25 Time 11:45 Sent To G
Notes
2007-04-25 11:48:29****************PROVISO****************
 1) COMPLY WITH FBC-2004 SEC 424.2, OR
 FBCR-2004 SEC R4101 PRIVATE SWIMMING
 POOLS.
 2) FBC-2004 SEC. 424.2.14, OR FBCR-2004
 SEC. R4101.15 GAS PIPING SHALL COMPLY
 WITH FBC FUEL GAS.SEPARATE PLANS AND
 PERMIT REQUIRED.

Review Stop Z ZONING
Rev No 2 Status P Date 2007-05-09 Cont ID  
Sent By jroach Date 2007-05-09 Time 19:19 Rev Time 0.00
Received By jroach Date 2007-05-09 Time 19:19 Sent To I
Notes
2007-05-09 19:20:45FENCE TO ENCLOSE POOL SUBMITTED UNDER PERMIT #07040236.
 ALL GATES ARE TO BE SELF-CLOSING AND SELF-LATCHING.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER,
 AT (561) 822-1435.

Review Stop Z ZONING
Rev No 1 Status F Date 2007-04-12 Cont ID  
Sent By jroach Date 2007-04-12 Time 16:55 Rev Time 0.00
Received By jroach Date 2007-04-12 Time 16:55 Sent To I
Notes
2007-04-12 16:57:08***FAILED***
  
 1) EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE OR
 SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT ACCESS
 BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF THE
 RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED.
 BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN
 HEIGHT ABOVE GRADE.
  
 2) ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE THROUGH
 A BUILDING OR THROUGH A SELF-CLOSING AND SELF-LATCHING
 GATE OR THROUGH A SCREEN ENCLOSURE DOOR WITH LATCHES
 PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF GATE.(CHILD
 SAFETY BARRIERS DO NOT SATISFY THIS REQUIREMENT).AT
 LEAST 90 PERCENT OF THE SURFACE AREA OF ALL SCREEN
 ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH WHICH
 AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT SHALL
 BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A
 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE,
 AT THE PROPERTY LINE, TO ENSURE PRIVACY.
  
 AS THE SURVEY DOES NOT SHOW AN EXISTING FENCE THAT
 WOULD SATISFY THIS REQUIREMENT, A FENCE PERMIT SHALL BE
 SUBMITTED CONCURRENTLY WITH THE POOL PERMIT.
  
 3) SETBACKS SHALL BE PROVIDED FROM THE PROPERTY LINES
 TO THE POOL EQUIPMENT.THE EQUIPMENT SHALL BE A
 MINIMUM OF 11 FEET FROM THE REAR PROPERTY LINE.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER,
 AT (561) 822-1435.