| Plan Review Stops For Permit 07040274 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-08-30 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-30 |
Time |
07:12 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-08-30 |
Time |
07:12 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-06-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-06-13 |
Time |
12:03 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2007-06-13 |
Time |
12:02 |
Sent To |
PC |
|
| Notes |
| 2007-06-13 12:33:42 | BUILDING PLAN REVIEW | | | PERMIT: 07040274 | | | ADD: 6329 N JOG RD | | | CONT: DELTA PETROLEUM | | | TEL: (561)722-1632 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | 2A) THE REPLACEMENT OF THE ABOVE GROUND DIESEL TANK | | | DOESN'T PROVIDE ANY MANUFACTURERES INFORMATION, PLEASE | | | PROVIDE ADDITIONAL INFORMATION. IF THIS SYSTEM PROVIDES | | | A DOUBLE WALLED TANK, IF SO OF WHAT TYPE OF MATERIAL? | | | FBC 4115.2.5 | | | 2B) THE SECOND CONCERN IS IF THE TANK TO BE PROVIDED IS | | | A DOUBLE WALLED TANK HOW WOULD ONE KNOW IF THERE IS A | | | LEAK BETWEEN THE TANKS? IS THERE AN LEAKAGE ALARM OR | | | SIGNAL OF SOME TYPE? FBC 415.7.2.6 | | | 2C) IN THE FUEL SYSTEM SITE WORK FOR THE REMOVAL OF THE | | | OLD 5,000 DIESEL TANK THE PLANS INDICATE THE OLD | | | CONTAINMENT WALL AND PEDESTALS WERE TO BE REMOVED. | | | SECTION FBC 415.7.2.2 IT INDICATES EITHER A FIRE | | | BARRIER WALL OR HORIZONTAL ASSEMBLIES OR BOTH AROUND | | | THE STORAGE TANK SHALL BE PERMITTED. | | | | | | 3) SHEET 2OF 2 TANK ANCHOR DETAIL INDICATES(1)1" | | | REDHEAD TO BE INSTALLED INTO A 3,000 PSI SLAB. THE PLAN | | | DOES NOT INDICATE HOW MANY ANCHORS WILL NEED TO BE | | | INSTALLED TO RESIST THE MOMENT OF OVERTURNING?NOR | | | DOES THE PLAN INDICATE IF THIS IS A NEW SLAB OR A | | | REUSED SLAB. THERE IS A SLAB DETAIL FOR A FUEL SLAB? | | | | | | 4) THIS SAME ANCHORING SYSTEM DOES NOT PROVIDE ALL THE | | | WIND INFO REQUIRED.2004 FL. BLD CODE 1603.1.4 THE | | | FOLLOWING INFORMATION RELATED TO WIND | | | SHALL BE SHOWN ON THE CONSTRUCTION | | | DRAWINGS, | | | 1)- BASIC WIND SPEED, MPH | | | 2)- WIND IMPORTANCE FACTOR, & BUILDING CATEGORY (FUEL | | | DISPENSING FACILITY) | | | 3)- WIND EXPOSURE | | | 4)- INTERNAL PRESSURE COEFFICIENT, | | | | | | 5) 406.5.1 CONSTRUCTION.MOTOR FUEL-DISPENSING | | | FACILITIES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE | | | FLORIDA FIRE PREVENTION CODE AND THIS SECTION. | | | | | | 6) PLEASE PROVIDE THE MSDS SHEETS FOR DIESEL. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-07-23 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-07-23 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-07-23 |
Time |
15:17 |
Sent To |
I |
|
| Notes |
| 2007-07-23 15:23:48 | ELEC OK, ELECTRICAL PERMIT REQUIRED REQUIRED. | | 2007-07-23 15:18:27 | PLANS REMOVED FROM INCOMING, WILL BE RETURNED TO | | | INCOMING WAITING FOR COMM BOARD ONCE REVIEW IS | | | COMPLETED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-04-21 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-04-21 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-04-21 |
Time |
13:01 |
Sent To |
|
|
| Notes |
| 2007-04-21 13:30:40 | ** UNSAT ** | | | | | | 1) NOTE: PLEASE STATE ON PLANS ALL UPDATED DATED | | | ADOPTED CODES AS OF DECEMBER 8TH, 2006 WHICH MUTS | | | INCLUDE THE FOLLOWING AT A MINIMUM FOR ELECTRICAL. | | | NFPA-70 2005, 2004 FBC W/ 2006 REVISIONS. | | | ** SEE OTHER TRADE REVIEWS FOR ANY OTHER CODES. | | | | | | 2) NOTE: PLEASE PROVIDE A LAYOUT FOR ALL CLASS AND | | | DIVISION LOCATIONS PER NEC 514. | | | PLEASE INDICATE THE DISTANCE FOR EPO DEVICE. PLEASE SEE | | | THE MINIMUM/MAXIMUM 541.11C | | | | | | 3) NOTE: PLEASE INDICATE ANY INCREASE OF LOAD ON THE | | | PANEL WHICH IS SHOWN AS EXISTING. | | | 220 | | | FBC 106.1.2 | | | | | | 4) NOTE: PLEASE PROVIDE FURTHER DETAIL FOR GROUNDING AS | | | NOTED. PLEASE INDICATE SIZING, ATTACHMENT LOCATIONS. | | | (NEW AND/OR EXISTING MEETING CURRENT CODE.514.16, 250, | | | 501.130 | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-08-13 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-08-13 |
Time |
16:57 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-08-13 |
Time |
16:41 |
Sent To |
|
|
| Notes |
| 2007-08-13 16:52:32 | *****APPROVED***** | | | | | | | | | ALL COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | | BEEN SATISFIED;PLAN SHEET 2 (OF 2) STAMPED, | | | INITIALED, AND DATED. | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-06-01 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-06-01 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-06-01 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2007-06-01 12:49:28 | *****DENIED***** | | | | | | | | | 1.THE COMPLETE ADDRESS OF THE PROJECT LOCATION SHALL | | | BE IN THE TITLE BLOCK OF EACH SUBMITTED PLAN SHEET. | | | PLEASE NOTE THAT THE NUMBER 6329 IS MISSING. | | | | | | 2.PRECAUTIONS SHALL BE TAKEN TO PREVENT THE IGNITION | | | OF FLAMMABLE VAPORS FROM THE VARIOUS SOURCES BEFORE, | | | DURING, AND AFTER THE PROJECTED SCOPE OF WORK. | | | | | | 3.SMOKING SHALL BE PERMITTED ONLY IN DESIGNATED AND | | | PROPERLY IDENTIFIED AREAS. | | | | | | 4.ALL METALLIC EQUIPMENT WHERE AN IGNITABLE MIXTURE | | | COULD BE PRESENT SHALL BE BONDED OR GROUNDED. | | | | | | 5.UNSUPERVISED, ISOLATED ABOVEGROUND STORAGE TANKS | | | SHALL BE SECURED AND MARKED IN SUCH A MANNER AS TO | | | IDENTIFY THE FIRE HAZARDS OF THE TANK AND THE TANK'S | | | CONTENT.THE AREA IN WHICH THE TANK IS LOCATED SHALL | | | BE PROTECTED FROM TAMPERING OR TREPASSING, WHERE | | | NECESSARY. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH COMMENT WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-07-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-11 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-11 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2007-07-24 10:02:31 | TO "COMM" BD#24 | | 2007-07-11 09:28:51 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-06-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-06-13 |
Time |
12:02 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2007-04-09 |
Time |
16:58 |
Sent To |
|
|
| Notes |
| 2007-04-12 13:46:23 | TO "COMM" BD#4 | | 2007-04-09 16:58:51 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2007-08-02 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-08-02 |
Time |
09:35 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-08-02 |
Time |
08:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-05-01 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-05-01 |
Time |
08:22 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-05-01 |
Time |
08:06 |
Sent To |
|
|
| Notes |
| 2007-05-01 08:22:03 | --------------DENIED---------------- | | | | | | PLEASE REFERENCE FLORIDA BUILDING CODE 2004 W/2006 | | | REVISIONS, AND NOT THE UNIFORM BUILDING CODE. | | | | | | PLEASE REVISE DRAWING TO ACCURATELY REFLECT TESTING | | | METHODS AS STATED IN THE ATTACHED INSTALLATION | | | INSTRUCTIONS. PLAN IS NOT TO BE ALTERED BY ANYONE OTHER | | | THAN THE DESIGNER OF RECORD. | | | | | | REVIEWED BY: | | | RONALD J REGUEIRO | | | 561.805.6719 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-07-31 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2007-07-31 |
Time |
17:38 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2007-07-31 |
Time |
17:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-04-13 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2007-04-13 |
Time |
12:21 |
Rev Time |
0.00 |
| Received By |
eschneid |
Date |
2007-04-13 |
Time |
12:21 |
Sent To |
|
|
| Notes |
| 2007-04-13 13:03:03 | FAILED | | | | | | 1) THE 2005 AERIAL OF THE SITE SHOWS THAT THERE IS | | | LANDSCAPING THAT PROVIDES A BUFFER FOR THE EAST SIDE OF | | | THE TANK ADJACENT TO THE DRIVE AISLE.PLEASE VERIFY, | | | EITHER ON THE PLAN OR WITH PHOTOS, THAT THE LANDSCAPING | | | REMAINS ON THE EAST SIDE OF THE TANK.IF THE LANDSCAPE | | | NO LONGER EXISTS, A HEDGE WILL BE REQUIRED TO SCREEN | | | THE NEW TANK. | | | | | | CONTACT ERIC SCHNEIDER @ 822-1435. |
|
|