| Plan Review Stops For Permit 07040266 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-05-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-05-10 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-05-10 |
Time |
12:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-04-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-04-30 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-04-30 |
Time |
12:57 |
Sent To |
|
|
| Notes |
| 2007-04-30 13:59:50 | DENIED BY BUILDING | | | | | | 1) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 2) SUBMIT MANUFACTURER'S SPECIFICATIONS AND | | | LISTING/LABELING INFORMATION FOR THE GRILL AND SIDE | | | BURNERS. SEE G2406. | | | | | | 3) SPECIFICATIONS MUST INDICATE THAT THE GRILL AND SIDE | | | BURNERS CAN BE LOCATED ON A COVERED PORCH AND IN THE | | | LOCATION AND CONDITIONS OF THE PROPOSED INSTALLATION. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-05-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-05-07 |
Time |
14:43 |
Rev Time |
0.25 |
| Received By |
btrobaug |
Date |
2007-05-07 |
Time |
14:43 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2007-04-25 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-04-25 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-04-25 |
Time |
07:47 |
Sent To |
G |
|
| Notes |
| 2007-04-25 11:32:15 | | | | | | | NOTE: | | | | | | PER 2704.1, 2004 FBC, METAL FRAMING MEMBERS SHALL BE | | | BONDED TO THE EQUIPMENT GROUNDING CONDUCTOR FOR THE | | | CIRCUIT THAT MAY ENERGIZE THE FRAMING. PLEASE SEE | | | ARTICLE. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2007-04-25 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-04-25 |
Time |
13:12 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-04-25 |
Time |
13:12 |
Sent To |
M |
|
| Notes |
| 2007-04-25 13:15:01 | CONTRACTOR INFORMATION | | | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL INSPECTION. | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-05-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-05-03 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-05-03 |
Time |
10:09 |
Sent To |
E |
|
| Notes |
| 2007-05-03 10:09:50 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-04-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-24 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-24 |
Time |
09:03 |
Sent To |
E |
|
| Notes |
| 2007-04-24 09:03:36 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-04-30 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-04-30 |
Time |
12:57 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-04-09 |
Time |
16:33 |
Sent To |
|
|
| Notes |
| 2007-04-09 16:33:35 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2007-05-07 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-05-07 |
Time |
14:58 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-05-07 |
Time |
14:58 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-04-25 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-04-25 |
Time |
14:45 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-04-25 |
Time |
14:45 |
Sent To |
B |
|
| Notes |
| 2007-04-25 14:58:54 | *** DENIED *** | | | 1) SITE PLAN SHOWS THE GAS GRILL TO BE UNDER A COVERED | | | PATIO, THIS MAY REQUIRE AN APPROVED EXHAUST HOOD. | | | PLEASE SUBMIT DETAILED MANUFACTURER'S SPECIFICATION'S | | | AND INSTALLATION INSTRUCTIONS FOR THE GAS GRILL. ALSO | | | SUBMIT A DETAIL REGARDING THE COVERED PATIO (MATERIAL, | | | HEIGHT, LOCATION TO COMBUSTIBLES, ECT.). | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2007-04-20 |
|
|
Cont ID |
|
| Sent By |
jbabcock |
Date |
2007-04-20 |
Time |
16:24 |
Rev Time |
0.00 |
| Received By |
jbabcock |
Date |
2007-04-20 |
Time |
16:24 |
Sent To |
|
|
| Notes |
|
|