| Plan Review Stops For Permit 07040251 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-05-24 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-05-24 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-05-24 |
Time |
07:54 |
Sent To |
|
|
| Notes |
| 2007-05-24 08:36:28 | BUILDING PROVISO: | | | TO BE IN PLACE AT C.O.: | | | | | | 1) 424.2.17.1 OUTDOOR SWIMMING POOLS. | | | OUTDOOR SWIMMING POOLS SHALL BE PROVIDED | | | WITH A BARRIER COMPLYING WITH | | | 424.2.17.1.1 THROUGH 424.2.17.1.14. | | | | | | 424.2.17.1.5 CHILD SAFETY BARRIER | | | ASTM D5034 100 LB TENSILE STRNGTH | | | ASTM D3787 150 LB BALL BURST | | | STRENGTH | | | | | | 2) 13-612.1.ABC.2.3.2 COVERS REQUIRED. | | | SPAS AND HEATED SWIMMING POOLS SHALL BE | | | EQUIPPED WITH A COVER DESIGNED TO | | | MINIMIZE HEAT LOSS. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-04-28 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-04-28 |
Time |
09:50 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-04-28 |
Time |
07:27 |
Sent To |
PC |
|
| Notes |
| 2007-04-28 09:50:07 | BUILDING PLAN REVIEW | | | PERMIT: 07040251 | | | ADD: 340 E. LAKEWOOD RD | | | CONT: STREAMLINE POOL CO. INC. | | | TEL: (561)723-0162 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 1ST | | | ACTION: DENIED | | | | | | 1)THE VALUE IS LOW. THE CLAIMED VALUATION ON THE | | | PERMIT APPLICATION IS LOW. FOR PERMITTING PURPOSES, | | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE THE TOTAL | | | REPLACEMENT COST EXCLUDING LAND VALUE. OUR VALUATION | | | REFERENCE IS ICC (BVD), MARSHALL-SWIFT AND MEANS COST | | | ANALYSIS SERVICES PER 108.3 FBC* | | | | | | 2)INDICATE THE SQUARE FOOTAGE OF THE POOL DECK ON THE | | | DRAWINGS. PER.106.1.1 | | | | | | 3)FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF | | | THE COURT. | | | NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS | | | NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE | | | RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: | | | 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT | | | THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2007-04-18 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-04-18 |
Time |
07:44 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2007-04-18 |
Time |
07:35 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2007-04-24 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-04-24 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-04-24 |
Time |
10:08 |
Sent To |
B |
|
| Notes |
| 2007-04-24 10:11:16 | CONTRACTOR INFORMATION | | | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | | BEFORE FINAL POOL INSPECTION. | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-05-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-15 |
Time |
09:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-15 |
Time |
09:32 |
Sent To |
B |
|
| Notes |
| 2007-05-15 09:32:42 | TO "MJACOBS" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-05-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-08 |
Time |
11:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-08 |
Time |
11:56 |
Sent To |
Z |
|
| Notes |
| 2007-05-08 11:57:10 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-04-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-12 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-12 |
Time |
10:07 |
Sent To |
E |
|
| Notes |
| 2007-04-12 10:08:17 | TO "E" BOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2007-04-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-09 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2007-04-09 13:45:54 | TO "Z" BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2007-04-24 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-04-24 |
Time |
10:05 |
Rev Time |
0.33 |
| Received By |
mperson |
Date |
2007-04-24 |
Time |
10:05 |
Sent To |
G |
|
| Notes |
| 2007-04-24 10:08:39 | ****************PROVISO**************** | | | 1) FBC-2004 SEC. 424.2.7.1, OR FBCR-2004 SEC.R4101.7.1 | | | POOL CIRCULATING PUMPS | | | SHALL BE EQUIPPED ON THE INLET SIDE WITH | | | AN APPROVED TYPE HAIR AND LINT STRAINER | | | WHEN USED WITH A PRESSURE FILTER. | | | (DETAIL OR ADD TO NOTES) | | | 2) FBC-2004 SEC. 424.2.14.4, OR | | | FBCR-2004 SEC. R4101.14.4 CONNECTIONS, | | | ALL WATER HEATING EQUIPMENT SHALL BE | | | INSTALLED WITH FLANGES OR UNION | | | CONNECTIONS ADJACENT TO THE HEATER. | | | (ADD TO NOTES) | | | 3) FBC-2004 SEC. 424.2.14, OR FBCR-2004 | | | SEC. R4101.15 GAS PIPING SHALL COMPLY | | | WITH FBC FUEL GAS.SEPARATE PLANS AND | | | PERMIT REQUIRED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-06-07 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-06-07 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-06-07 |
Time |
11:06 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-05-10 |
|
|
Cont ID |
|
| Sent By |
choops |
Date |
2007-05-10 |
Time |
11:02 |
Rev Time |
0.00 |
| Received By |
choops |
Date |
2007-05-10 |
Time |
11:02 |
Sent To |
I |
|
| Notes |
| 2007-05-10 11:04:20 | ***FAILED*** | | | | | | | | | 1)REQUIRES A SEPERATE PERMIT FOR THE REQUIRED FENCE | | | TO BE SUBMITTED CONCURRENTLY. | | | | | | | | | CHRIS HOOPS | | | ZONING TECHNICIAN | | | 561-805-6720 | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-04-10 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-04-10 |
Time |
17:57 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-04-10 |
Time |
17:57 |
Sent To |
I |
|
| Notes |
| 2007-04-10 18:01:04 | ***FAILED*** | | | | | | 1) SURVEY SHALL BE UPDATED TO SHOW THE LOCATION OF THE | | | RESIDENCE AS WELL AS THE LOCATION OF THE PROPOSED POOL | | | AND ASSOCIATED EQUIPMENT.TWO (2) COPIES SHALL BE | | | PROVIDED. | | | | | | 2) DIMENSION SHALL BE PROVIDED FROM THE POOL EQUIPMENT | | | TO THE PROPERTY LINE ON THE SURVEY AND SITE PLAN. | | | | | | 3) EVERY SWIMMING POOL SHALL BE ENCLOSED BY A FENCE OR | | | SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT ACCESS | | | BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF THE | | | RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED. | | | BARRIERS OR FENCES SHALL BE AT LEAST FOUR FEET IN | | | HEIGHT ABOVE GRADE. | | | | | | 4) ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE THROUGH | | | A BUILDING OR THROUGH A SELF-CLOSING AND SELF-LATCHING | | | GATE OR THROUGH A SCREEN ENCLOSURE DOOR WITH LATCHES | | | PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF GATE.(CHILD | | | SAFETY BARRIERS DO NOT SATISFY THIS REQUIREMENT).AT | | | LEAST 90 PERCENT OF THE SURFACE AREA OF ALL SCREEN | | | ENCLOSURES SHALL BE SCREENING MATERIAL THROUGH WHICH | | | AIR SHALL FLOW. ALL POOLS LOCATED ON A CORNER LOT SHALL | | | BE SCREENED AT THE CORNER LOT LINE BY AT LEAST A | | | 42-INCH HIGH LANDSCAPE BUFFER, AS MEASURED FROM GRADE, | | | AT THE PROPERTY LINE, TO ENSURE PRIVACY. | | | | | | AS THERE IS NO EXISTING FENCE TO SURROUND THE POOL | | | AREA, A FENCE PERMIT SHALL BE SUBMITTED CONCURRENTLY | | | WITH THE POOL PERMIT. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|