Plan Review Details - Permit 07040240
Plan Review Stops For Permit 07040240
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-07-23 Cont ID  
Sent By shill Date 2007-07-23 Time 18:03 Rev Time 0.00
Received By shill Date 2007-07-23 Time 18:03 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-06-21 Cont ID  
Sent By shill Date 2007-06-21 Time 15:51 Rev Time 0.00
Received By shill Date 2007-06-21 Time 15:51 Sent To  
Notes
2007-06-21 15:54:07****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 1.)PRESSURES DO NOT MATCH THE ENGINEERING.SEE YOU
 DESIGN PRESSURES ON THE INSTALLATION SCHEDULE AND THE
 ENGINEERING.HOW HAVE YOU ARRIVED AT THESE NUMBER?
 YOU NEED TO USE THE NUMBERS ON THE ENGINEERING.
  
 2.)3" EDGE DISTANCE REQUIRES A DECREASE IN ANCHOR
 SPACING, SEE SHEET5.
  
 3.)SPANS SPECIFIED 11'10 EXCEED ALLOWABLE SPAN OF
 11'.IT IS NOT CLEAR WHY YOU ARE USING A 11'10" SPAN
 FOR AN 8' OPENING.PLEASE REVISE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-06-11 Cont ID  
Sent By shill Date 2007-06-11 Time 16:04 Rev Time 0.00
Received By shill Date 2007-06-11 Time 16:04 Sent To  
Notes
2007-06-11 16:07:03****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* CITY
 OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
  
 1.)PLEASE REMOVE THE COMPUTERIZED WIND LOADS.THE
 SIGNED, SEALED ENGINEERING IS TO BE USED FOR DESIGN
 PRESSURES.
  
 2.)THE ANCHORING IS COMPLIANT BUT YOUR INSTALLATION
 SCHEDULE IS USING THE COMPUTERIZED WIND LOADS RATHER
 THAN THE PRESSURES SPECIFIED BY THE ENGINEER.PLEASE
 REVISE.
  
 3.)SEE PREVIOUS LIST.FLORIDA STATE OR LOCAL PRODUCT
 APPROVAL REQUIRED (ONLY THE EVALUATION REPORT WITHOUT
 THE FL NUMBER WAS PROVIDED).WWW.FLORIDABUILDING.ORG
 FAC9B72.THE RESUBMITTAL SHEET STATES THAT THE FL IS
 "NOT AVAILABLE".THIS IS REQUIRED.IF THIS PRODUCT
 DOES NOT HAVE A FL STATE PRODUCT APPROVAL, ORIGINAL
 ENGINEERING WITH A LOCAL PRODUCT APPROVAL APPLICATION
 IS REQUIRED.HOWEVER, I BELIEVE THAT A FL APPROVAL IS
 AVAILABLE AS IT APPEARS THAT THE EVAULATION REPORT YOU
 PROVIDED WAS FROM THE FL WEBSITE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-04-18 Cont ID  
Sent By shill Date 2007-04-18 Time 17:54 Rev Time 0.00
Received By shill Date 2007-04-18 Time 17:54 Sent To  
Notes
2007-04-18 17:55:53****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
 ____1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH
 THE CLERK OF COURTS BEFORE A PERMIT CAN BE ISSUED,
 FS713.13.
  
 _XX_2.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN
 PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE
 DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A
 DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ENGINEER
 AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED
 ORIGINALS FAC61G15-23.002.CITY OF WPB IS IN THE
 140MPH ZONE.ENGINEERING FOR 75MPH WAS SUBMITTED, SEE
 FBC1609.
  
 _XX_3.PROVIDE A COPY OF THE CONDO ASSOCIATION
 APPROVAL.
  
 _XX_4.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT.
  
 _XX_5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.IF FL
 STATE PRODUCT APPROVAL IS NOT AVAILABE PLEASE ADVISE
 AND A LOCAL WILL BE ISSUED USING THE NOA.
  
 ____6.ON THE PRODUCT APPROVAL, MARK WHICH DETAILS
 APPLY TO THIS JOB.PLEASE USE INK RATHER THAN A
 HIGHLIGHTER.
  
 ____7.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC
 R310.
  
 ____8.PROVIDE A FLOOR PLAN SHOWING WHERE THE
 SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH
 CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 4
 ABOVE.
  
 ____9.REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2),
 FBC R301.2.1.4.NOTE THAT THE DEFINITION FOR EXPOSURE
 C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC
 R301.2.1.4.
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-07-11 Cont ID  
Sent By adarroug Date 2007-07-11 Time 15:12 Rev Time 0.00
Received By adarroug Date 2007-07-11 Time 15:12 Sent To B
Notes
2007-07-11 15:12:23TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-06-18 Cont ID  
Sent By adarroug Date 2007-06-18 Time 15:50 Rev Time 0.00
Received By adarroug Date 2007-06-18 Time 15:50 Sent To B
Notes
2007-06-18 15:50:17TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-05-21 Cont ID  
Sent By adarroug Date 2007-05-21 Time 11:49 Rev Time 0.00
Received By adarroug Date 2007-05-21 Time 11:49 Sent To B
Notes
2007-05-21 11:50:13TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-04-18 Cont ID  
Sent By shill Date 2007-04-18 Time 17:56 Rev Time 0.00
Received By shill Date 2007-04-09 Time 13:20 Sent To  
Notes
2007-04-09 13:21:03TO "MISC" BOX#1