 |
Plan Review Details - Permit 07040094
| Plan Review Stops For Permit 07040094 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2008-05-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-05-14 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-05-13 |
Time |
13:55 |
Sent To |
|
|
| Notes |
| 2008-05-14 15:40:13 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | FAC FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | COMMENTS FROM PREVIOUS LIST: | | | | | | 1. NOTE CORRECTION SUBMITTAL | | | WHEN RE-SUBMITTING CORRECTED PLANS FOR PERMITTING, | | | PLEASE REMOVE AND REPLACE ANY SHEETS AS NECESSARY. | | | INCLUDE A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER WITH A DESCRIPTION OF THE | | | REVISION MADE. IDENTIFY THE SHEET OR SPECIFICATION | | | PAGE | | | WHERE THE CHANGES CAN BE FOUND AND INCLUDE THE OLD | | | SHEETS IN THE RE-SUBMITTAL PACKAGE FOR THE PLAN | | | REVIEWER'S REFERENCE. | | | THIS SHALL HELP TO EXPEDITE YOUR PERMIT. THANK YOU | | | FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2. F.S. 713.13 NOTICE OF COMMENCEMENT | | | FILE NOTICE WITH THE CLERK OF COURT RECORDING | | | DIVISION. | | | IF THE WORK DESCRIBED IN THE NOTICE IS NOT COMMENCED | | | | | | WITHIN 90 DAYS OF FILING THE NOTICE WILL BECOME NULL | | | | | | AND VOID. SUBMIT THE NOTICE AT THE TIME OF PERMIT | | | ISSUANCE AND POST A COPY AT THE JOB SITE BEFORE THE | | | FIRST INSPECTION. | | | | | | 3. NOTES SHEET 2.1 | | | | | | (A) ADDRESSED. | | | | | | (B) PROJECT INFORMATION - PLEASE COMPLETE ON PLAN | | | INFORMATION | | | CONSTRUCTION TYPE | | | | | | 3RD REVIEW, TYPE DECLARED IS TYPE II, BUT DETAILS SHOW | | | WOOD TRUSSES.NO INFORMATION PROVIDED REGARDING THE | | | EXISTING OFFICE BUILDING, SEE FBC503.1.3. | | | | | | OCCUPANT LOAD | | | | | | 3RD REVIEW, SEE FBC 1004, OCCUPANT LOAD CANNOT BE LESS | | | THAN FBC TABLE 1004.2.1. | | | | | | OTHER INFORMATION WAS REQUESTED AND PROVIDED, BUT DUE | | | TO INCORRECT/INCOMPLETE INFORMATION, CODE COMPLIANCE | | | CANNOT BE DETERMINED.COMPLETE INFORMATION REGARDING | | | THE TWO BUILDINGS MUST BE PROVIDED AS WELL AS | | | INFORMATION REGARDING HOW YOU ARE COMPLYING WITH FBC | | | TABLE 601, FBC TABLE 602, FBC TABLE 503, FBC TABLE | | | 704.8.WITHOUT ALL INFORMATION REQUIRED, CODE | | | COMPLIANCE CANNOT BE DETERMINED.NO INFORMATION | | | REGARDING HOW THIS PROJECT COMPLIES WAS PROVIDED.SEE | | | FIRST COMMENT LIST, ALL CALCULATIONS REGARDING ANY AREA | | | INCREASES ARE TO BE ON THE PLAN.NO AREA INCREASES | | | WERE TAKEN BUT THE WRONG BUILDING TYPE DECLARED.NOT | | | ENOUGH INFORMATION PROVIDED TO DETERMINE CODE | | | COMPLIANCE. | | | | | | | | | FBC 501.2 PREMISES IDENTIFICATION. | | | 3RD REVIEW, PLEASE NOTE THAT THIS WAS ADDRESSED AS | | | REQUESTED.HOWEVER, CITY OF WEST PALM BEACH MUNICIPAL | | | CODE 78-6(1) AND ALSO NFPA 101/FLORIDA FIRE PREVENTION | | | CODE REQUIRE 6IN HIGH, 1IN WIDE MINIMUM.PLEASE NOTE | | | THAT HAD ALL OTHER ITEMS BEEN ADDRESSED, THIS WOULD | | | HAVE BEEN A REDLINE/PROVISO ITEM. | | | | | | FBC 602.2 TYPES I AND II. | | | TYPE I AND II CONSTRUCTION ARE THOSE TYPES OF | | | CONSTRUCTION IN WHICH THE BUILDING ELEMENTS LISTED | | | IN | | | | | | TABLE 601 ARE OF NONCOMBUSTIBLE MATERIALS. | | | | | | 3RD REVIEW, WOOD TRUSSES SHOWN; TYPE II IS TO BE | | | NONCOMBUSTIBLE.ALSO A OR B MUST BE DECLARED AND ANY | | | FIRE RESISTANCE RATINGS REQUIRED SHOWN ON THE PLAN, FBC | | | TABLE 601.NO INFORMATION PROVIDED IN REGARDS TO | | | EXISTING OFFICE BUILDING; SEE OTHER COMMENTS. | | | | | | COMMENT 3D) FBC 11-4.1.6 II ACCESSIBLE BUILDINGS - | | | ALTERATIONS | | | PLANS DO NOT INDICATE OR IDENTIFY THE ACCESSIBLE | | | ENTRANCE INTO THE BUILDING. PLANS INDICATE A 4?IN | | | DIFFERENCE IN ELEVATION AT ENTRANCES FROM PARKING AREA | | | TO UNIT SPACES. | | | | | | 3RD REVIEW, PLAN STILL SHOW A 4IN ELEVATION CHANGE AT | | | THE RAMP, SHEET 2.1, EAST SIDE.SEE OTHER COMMENTS | | | REGARDING ACCESSIBLE ROUTE. | | | | | | 11-4.3.1-. ALL WALKS/HALLS/CORRIDORS SHALL BE | | | ACCESSIBLE | | | | | | 3E.FBC 1210.1 AND 1210.2 FLOORS / WALLS | | | URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD, | | | | | | NON-ABSORBENT SURFACE | | | | | | 3RD REVIEW, DRYWALL SHOWN ON THE PLAN.THIS IS NOT A | | | HARD NON-ABSORBENT SURFACE. | | | | | | 3. | | | B) USE AND OCCUPANCY COMPLETE INFORMATION | | | C) TYPE OF CONSTRUCTION | | | E) SPRINKLER SYSTEM REQUIREMENT | | | | | | 3RD REVIEW, NOT COMPLETELY ADDRESSED.PLEASE SEE OTHER | | | COMMENTS. | | | | | | 4. FBC EXISTING 812.4.2 | | | HAZARD CATEGORIES IN REGARD TO HEIGHT AND AREA SHALL | | | BE | | | IN ACCORDANCE WITH TABLE 812.4.2. | | | SEE TABLE FOR CLASSIFICATIONS | | | | | | I WAS UNABLE TO LOCATE WHERE THIS WAS ADDRESSED ON THE | | | PLAN.PLEASE ADVISE.ALSO IT IS NOT CLEAR IF YOU ARE | | | TREATING THIS AS ONE BUILDING OR TWO BUILDINGS WITH AN | | | ASSUMED PROPERTY LINE, FBC503.1.3. | | | | | | 5. WALL INSULATION VALUES ON ENERGY | | | CALCULATIONS DOT NOT MATCH PLAN | | | | | | 3RD REVIEW, INPUT DATA REPORT FOR ENERGY CALCS NOT | | | INCLUDED.INCOMPLETE INFORMATION; NO REVIEW CAN BE | | | DONE AT THIS TIME. | | | | | | ROOFING SYSTEM TAMKO, HIGHLIGHT SYSTEM USED | | | AND MATCH ENERGY CALCULATIONS FOR SPECIFIED | | | MATERIALS | | | | | | IN SYSTEM | | | | | | 3RD REVIEW, A SYSTEM WAS SELECTED BUT REQUIRES | | | ENGINEERING FOR THE ENHANCED FASTENING FOR ZONES 2 AND | | | 3.THIS MAY BE PROVIDED AT THIS TIME OR AT THE TIME OF | | | ROOF PERMIT APPLICATION (PROVISO ITEM). | | | | | | NOTE THAT A PRELIMINARY REVIEW WAS DONE ON THE NOA | | | SUBMITTED, BUT IF THIS BUILDING IS A TYPE II, WOOD DECK | | | CANNOT BE USED AND THE APPROPRIATE NOA SUBMITTED. | | | | | | 6-7.ADDRESSED. | | | | | | 8.FURNISH TRUSS ENGINEERED DRAWINGS FOR REVIEW | | | | | | THIS WAS REQUESTED BY PREVIOUS PLANS EXAMINER AND NOT | | | ADDRESSED.THIS PERMIT MAY BE ISSUED WITH A PROVISO | | | THAT THEY BE SUBMTTED FOR REVIEW PRIOR TO INSTALLATION, | | | BUT THERE ARE OTHER ISSUES WITH THE ROOF FRAMING PLAN. | | | IT IS NOT CLEAR ON SHEET 5.1 WHERE I AND J ARE TO BE | | | INSTALLED. WHAT DO THE ARROWS ON THE TIE DOWN SCHEDULE | | | MEAN?WHY ARE THE COLUMNS FOR CALCULATED LATERAL LOAN | | | BLANK?IF ARROWS INDICATE THE ONES TO BE USED, WHY ARE | | | THEY BLANK BUT OTHER CONNECTORS HAVE DATA?PROVIDE | | | DESIGN LOAD CRITERIA (WIND UPLIFT, LATERAL) WITH | | | CALCULATIONS. | | | | | | NEW COMMENTS (A RESULT OF PLAN CHANGES WHEN ADDRESSING | | | PREVIOUS COMMENTS): | | | | | | 9.SHEET 3.1 SHOWS AN ACUSTIC CEILING.DO YOU MEAN | | | ACOUSTIC?THE CEILING SPECIFIED ON 6.1 IS A HUNG | | | CEILING, BUT THAT IS NOT WHAT IS SHOWN GRAPHICALLY ON | | | WALL SECTIONS; THEY ARE SHOWN AS ATTACHED TO THE | | | TRUSSES.PLEASE CLARIFY; PROVIDE A SPECIFICATION FOR | | | ATTACHMENT. | | | | | | 10.FBC1008.1.8, THE HANDRAIL TO THE RAMP OBSTRUCTS | | | THE DOOR SWING.PLEASE EXPLAIN LOGIC OF HAVING A DOOR | | | BLOCKING THE CORRIDOR TO THE REQUIRED EXIT, SEE SHEET | | | 6.1. | | | | | | 11.THE BUILDING IS NOTED AS FULLY SPRINKLERED, NO | | | FIRE ALARM NOTES.SEE FBC11-4.28 AND SHOW REQUIRED | | | ALARMS IN AREAS SPECIFIED (SUCH AS BATHROOMS). | | | | | | 12.SEE OTHER TRADES? COMMENTS REGARDING ENERGY CALCS. | | | ALL BUILDING COMPONENTS TO BE INCLUDE.THE SQUARE FOOT | | | AREA DOES NOT MATCH PLAN.ENERGY CALCS ARE TO BE | | | PREPARED BY A DESIGN PROFESSIONAL, NOT CLEAR WHO HAS | | | SIGNED THIS.PROVIDE A SEAL AND PRINTED NAME. | | | | | | 13.SHEET 2.1, CLARIFY WALL FINISH SHOWN AS VINYL | | | COMPOSITE TILE; APPEARS TO BE FLOORING. | | | | | | 14.SPRINKLER PLANS ARE REQUIRED IF SPRINKLERS ARE | | | REQUIRED FOR CODE COMPLIANCE. | | | | | | 15.SHEET 2.1, A NOTE WAS ADDED STATING THAT THIS | | | BUILDING IS A SEPARATE BUILDING FROM THE EXISTING | | | BUILDING.ANY TIME THAT AN ADDITIONAL STRUCTURE IS | | | ADDED TO A PARCEL, CODE COMPLIANCE FOR THE NEW | | | STRUCTURE AS WELL AS THE EXISTING STRUCTURE MUST BE | | | SHOWN.THE EXISTING STRUCTURE WAS REVIEWED FOR CODE | | | COMPLIANCE REGARDING DISTANCE TO THE PROPERTY LINE, | | | SIZE, ETC.ADDING ANOTHER STRUCTURE TO THE PARCEL | | | CHANGES THE HAZARD TO THE EXISTING BUILDING. | | | | | | 16.SHEET 2.1, DEAD END REFERENCE INCORRECT. | | | | | | 17.SHEET 2.1, IT APPEARS THAT YOU ARE USING DESIGN | | | CRITERIA FOR A FULLY SPRINKLERED BUILDING.SEE OTHER | | | COMMENTS; IF SPRINKLERS ARE REQUIRED FOR CODE | | | COMPLIANCE SPRINKLER PLANS MUST BE PROVIDED PRIOR TO | | | PERMIT ISSUANCE.THIS HAS BEEN VERIFIED BY A | | | DECLARATORY STATEMENT FROM THE STATE, | | | FBC*106.3.5.1.1(5), FS553.79 (2). | | | | | | 18. SHEET 2.1, SQUARE FOOT AREA 4184, DOES NOT MATCH | | | OCCUPANT LOAD SQUARE FOOT AREA (2396 AND 1617), AND | | | DOES NOT MATCH ENERGY CALCS 4023. | | | | | | 19. SHEET 2.1, CORRIDOR FIRE RESISTANCE RATING PER FBC | | | TABLE 1016.1, REQUIREMENTS NOT CLEAR AS A FULLY | | | SPRINKLERED BUILDING WAS DECLARED, BUT NO INFORMATION | | | PROVIDED REGARDING THE OTHER BUILDING OR WHETHER THIS | | | WILL BE A SEPARATE BUILDING WITH AN ASSUMED PROPERTY | | | LINE, AND NO FIRE SPRINKLER PLANS PROVIDED. | | | | | | 20.MAXIMUM DEAD END, SHEET 2.1, WRONG CODE | | | REFERENCE. | | | | | | 21.EXITING FROM THE OTHER BUILDING AND HOW ACCESSIBLE | | | EXITING HAS BEEN AFFECTED IS NOT CLEAR.IS THE ROUTE | | | THROUGH THE NEW BUILDING TO THE PUBLIC WAY ALSO AN | | | ACCESSIBLE EXIT FOR THE OTHER BUILDING, OR DOES IT HAVE | | | EXITS ON THE OTHER SIDE OF THE BUILDING?IT APPEARS | | | THAT THE EXISTING BUILDING CURRENTLY HAS AN ACCESSIBLE | | | ROUTE TO THE PUBLIC WAY THROUGH THE EXISTING PARKING | | | LOT.THIS IS NOW BLOCKED BY THE NEW BUILDING, UNLESS | | | THEY USE THE CORRIDOR THROUGH THE NEW BUILDING.NO | | | FIRE RESISTANCE RATING SHOWN, BUT MAY BE REQUIRED. | | | | | | 22.THE NOTE REGARDING MAXIMUM TRAVEL ON SHEET 2.1 IS | | | NOT CLEAR.IT STATES 85FEET PER NOTE D, TABLE 1018.2. | | | THIS TABLE IS FOR BUILDINGS WITH ONE EXIT, AND NOTE D | | | IS APPLICABLE FOR BUSINESS OCCUPANCY, BUT THE NEW | | | BUILDING IS M AND S1 OCCUPANCY.AND, NOTHING ON THE | | | TABLE SPECIFIES 85FEET. | | | | | | 23. (FROM PREVIOUS LIST)FBC 1609.1.4 IMPACT | | | PROTECTION FOR GLAZED OPENINGSTHIS WILL REQUIRE A | | | SHUTTER PERMIT AND PRODUCT | | | APPROVALS SUBMITTED | | | | | | USE OF REMOVABLE SHUTTERS ON COMMERCIAL BUILDINGS MUST | | | BE APPROVED BY THE BUILDING OFFICIAL.SEE ATTACHED | | | POLICY, ITEM 13.A PLAN INCLUDING ALL INFORMATION | | | REFERENCED MUST BE SUBMITTED. THIS MAY BE DONE PRIOR TO | | | RESUBMITTAL OF THE BUILDING PERMIT PLANS FOR | | | PRELIMINARY REVIEW, [email protected] TO HAVE | | | THE PRE STORM PREPARATION PLAN APPROVED PRIOR TO | | | RESUBMITTAL OF THE PERMIT PACKAGE MAY RESULT IN DELAYS | | | IN PERMITTING. | | | | | | SEE PREVIOUS LIST, IMPACT PROTECTION REQUIRED | | | FBC1609.1.4.IF USE OF SHUTTERS IS PROPOSED, ATTACHED | | | INSTALLATION SCHEDULE MUST BE COMPLETED. | | | | | | 24.THE COMMENT REGARDING IMPACT FEES WAS ADDRESSED. | | | PLEASE KEEP THE STAMPED PLAN AND THE RECEIPT IN THE | | | PACKAGE. | | | | | | 25.DETAIL 3 3.1 SHOWS A CEILING OVER NEW HALL. | | | SPECIFY THE NEW CEILING, FBC*106. | | | | | | 26.DETAIL 4 4.1 TEST STATES THAT A 1 ? IN WATERSTOP | | | WILL BE INSTALLED; NONE SHOWN. | | | | | | 27. DETAIL 7 4.1 SHOWS A FLASHING DETAIL AT A FRAME | | | WALL.TYPE II IS DECLARED.WHERE WILL THIS BE | | | INSTALLED? | | | | | | 28.A VALUE ADJUSTMENT WAS DONE USING ICC TABLES. THIS | | | VALUE MAY CHANGE PENDING CORRECT INFORMATION ON PLANS. | | | (BUILDING TYPE, SQUARE FOOT AREA) | | | | | | 29.SHEET 5.1, CLARIFY ROOF DRAIN CALCULATIONS.SEE | | | PLUMBING COMMENTS REGARDING CALCULATIONS AND ROOF | | | DRAINAGE.ALSO SHOW PARAPET DIMENSION ON THE PARAPET | | | WALL DETAIL. | | | | | | 30.ROOF COMPONENTS AND CLADDING DESIGN PRESSURES | | | REQUIRED, FBC1603.1.4. | | | | | | 31.SEE ATTACHED FS553.80(2)(B).A 4X PLAN REVIEW | | | WILL BE CHARGED IF COMMENTS ARE NOT PROPERLY ADDRESSED | | | A THIRD TIME.A FEE MAY BE ASSESSED AT THIS TIME AS | | | SOME COMMENTS ARE FROM THE FIRST LIST.A SET HAS BEEN | | | RETAINED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-09-18 |
|
|
Cont ID |
|
| Sent By |
jjohnsto |
Date |
2007-09-18 |
Time |
12:13 |
Rev Time |
3.50 |
| Received By |
jjohnsto |
Date |
2007-09-18 |
Time |
07:45 |
Sent To |
|
|
| Notes |
| 2007-09-18 12:12:53 | CONSTRUCTION SERVICES DEPARTMENT | | | 200 SECOND STREET, 3RD FLOOR, WEST PALM BEACH, | | | FLORIDA33401 | | | TEL:561-805-6713FAX: | | | 561-805-6731 | | | | | | JAMES JOHNSTON,CBO PERMIT NO 07040094 | | | BUILDING PLAN EXAMINERII PROJECT GRATITUDE | | | GUILD, INC. | | | E-MAIL:JJOHNSTON @WPB.ORG ADDRESS 1700 NORTH | | | DIXIE HIGHWAY CONTRACTOR FRED BLAU & | | | ASSOCIATES | | | DATE SEPTEMBER18, 2007 | | | | | | | | | STRUCTURALPLANREVIEW | | | | | | 1. NOTE CORRECTION SUBMITTAL | | | WHEN RE-SUBMITTING CORRECTED PLANS FOR PERMITTING, | | | PLEASE REMOVE AND REPLACE ANY SHEETS AS NECESSARY. | | | INCLUDE A TRANSMITTAL LETTER LISTING THE ORIGINAL | | | REVIEW COMMENT NUMBER WITH A DESCRIPTION OF THE | | | REVISION MADE. IDENTIFY THE SHEET OR SPECIFICATION PAGE | | | WHERE THE CHANGES CAN BE FOUND AND INCLUDE THE OLD | | | SHEETS IN THE RE-SUBMITTAL PACKAGE FOR THE PLAN | | | REVIEWER?S REFERENCE. | | | THIS SHALL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2. F.S.713.13NOTICE OF COMMENCEMENT | | | FILE NOTICE WITH THE CLERK OF COURT RECORDING DIVISION. | | | IF THE WORK DESCRIBED IN THE NOTICE IS NOT COMMENCED | | | WITHIN 90 DAYS OF FILING THE NOTICE WILL BECOME NULL | | | AND VOID. SUBMIT THE NOTICE AT THE TIME OF PERMIT | | | ISSUANCE AND POST A COPY AT THE JOB SITE BEFORE THE | | | FIRST INSPECTION. | | | | | | 3. NOTESSHEET 2.1 | | | | | | (A) CODES | | | FLORIDA BUILDING CODE2004 WITH 2005 AND 2006 | | | REVISIONS | | | FLORIDA BUILDING CODE EXISTING BUILDINGWITH 2005 AND | | | 2006 REVISIONS | | | WEST PALM BEACH AMENDMENTS | | | | | | (B) PROJECT INFORMATION?PLEASE COMPLETE ON PLAN | | | INFORMATION? | | | CONSTRUCTION TYPE | | | LEVEL OF ALTERATION III | | | OCCUPANCY M / ?IDENTIFY THE STORAGE SPACE | | | USING FBCCHPT. 311.1 | | | OCCUPANT LOAD | | | OCCUPANT LOAD | | | NUMBER OF FLOORS 2 | | | FIRST FLOOR S.F. | | | SECOND FLOOR S.F. | | | TOTAL EXISTING S.F. | | | | | | | | | | | | | | | FBC 501.2 PREMISES IDENTIFICATION. | | | APPROVED NUMBERS OR ADDRESSES SHALL BE PROVIDED FOR NEW | | | BUILDINGS IN SUCH A POSITION AS TO BE CLEARLY VISIBLE | | | AND LEGIBLE FROM THE STREET OR ROADWAY FRONTING THE | | | PROPERTY. LETTERS OR NUMBERS SHALL BE A MINIMUM 3 | | | INCHES (76 MM) IN HEIGHT AND STROKE OF MINIMUM 0.5 INCH | | | (12.7 MM) OF A CONTRASTING COLOR TO THE BACKGROUND | | | ITSELF. | | | | | | FBC 602.2 TYPES I AND II. | | | TYPE I AND II CONSTRUCTION ARE THOSE TYPES OF | | | CONSTRUCTION IN WHICH THE BUILDING ELEMENTS LISTED IN | | | TABLE 601 ARE OF NONCOMBUSTIBLE MATERIALS. | | | | | | | | | COMMENT3D) FBC 11-4.1.6 IIACCESSIBLE BUILDINGS - | | | ALTERATIONS | | | PLANS DO NOT INDICATE OR IDENTIFY THE ACCESSIBLE | | | ENTRANCE INTO THE BUILDING. PLANS INDICATE A 4? | | | DIFFERENCE IN ELEVATION AT ENTRANCES FROM PARKING AREA | | | TO UNIT SPACES. | | | FBC 11-4.2??.SPACE ALLOWANCE AND REACH RANGES FBC | | | 11-4.3.1?.ALL WALKS/HALLS/CORRIDORS SHALL BE | | | ACCESSIBLE | | | FBC11-4.3.8?CHANGES IN LEVELS ALONG ACCESSIBLE | | | ROUTE | | | FBC11-4.1.3 (10)DRINKING FOUNTAIN MUST COMPLY WITH | | | ACCESSIBILITY CODE | | | | | | COMMENT3E)FBC1210.1AND 1210.2 FLOORS / WALLS | | | URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH, HARD, | | | NON-ABSORBENT SURFACE | | | | | | COMMENTS 3 ) | | | B)USE AND OCCUPANCYCOMPLETE INFORMATION | | | C) TYPE OF CONSTRUCTION | | | E)SPRINKLER SYSTEM REQUIREMENT | | | | | | DEFINE STORAGE AREA TYPE S-1 OR S-2 | | | 311.1 STORAGE GROUP S. | | | STORAGE GROUP S OCCUPANCY INCLUDES, AMONG OTHERS, THE | | | USE OF A BUILDING OR STRUCTURE, OR A PORTION THEREOF, | | | FOR STORAGE THAT IS NOT CLASSIFIED AS A HAZARDOUS | | | OCCUPANCY. | | | 311.2 MODERATE-HAZARD STORAGE, GROUP S-1. | | | 311.3 LOW-HAZARD STORAGE, GROUP S-2. | | | | | | COMMENT 4)FBC EXISTING812.4.2 | | | HAZARD CATEGORIES IN REGARD TO HEIGHT AND AREA SHALL BE | | | IN ACCORDANCE WITH TABLE 812.4.2 . | | | SEE TABLE FOR CLASSIFICATIONS | | | | | | COMMENT 5) WALL INSULATION VALUES ON ENERGY | | | CALCULATIONS DOT NOT MATCH PLAN | | | ROOFING SYSTEM TAMKO, HIGHLIGHT SYSTEM USED | | | AND MATCH ENERGY CALCULATIONS FOR SPECIFIED MATERIALS | | | IN SYSTEM | | | | | | FBC 1609.1.4IMPACT PROTECTION FOR GLAZED OPENINGS | | | THIS WILL REQUIRE A SHUTTER PERMIT AND PRODUCT | | | APPROVALS SUBMITTED | | | | | | | | | F.S.713.13NOTICE OF COMMENCEMENT | | | FILE NOTICE WITH THE CLERK OF COURT RECORDING DIVISION. | | | IF THE WORK DESCRIBED IN THE NOTICE IS NOT COMMENCED | | | WITHIN 90 DAYS OF FILING THE NOTICE WILL BECOME NULL | | | AND VOID. SUBMIT THE NOTICE AT THE TIME OF PERMIT | | | ISSUANCE AND POST A COPY AT THE JOB SITE BEFORE THE | | | FIRST INSPECTION. | | | | | | | | | | | | | | | IMPACT FEES | | | BEFORE A PERMIT TO CONSTRUCT MAY BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. | | | THE PERMITTED SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | PALM BEACH COUNTY ASSESSMENT | | | PALM BEACH COUNTY IMPACT FEE ASSESSMENT HAS MOVED TO: | | | 2300 N JOG ROAD, SUITE 2 WPB 33411 | | | | | | COMMENT 5)WINDOWS / DOORS PRODUCT APPROVALS | | | WPB ADMINISTRATIVE CODE 106.3 REGULATED BY DCA RULE | | | 9B-72FLORIDA PRODUCT APPROVAL | | | SUBMIT TWO COPIES OF EACH APPROVAL WITH FLORIDA PRODUCT | | | APPROVAL COVER SHEET THE ARCHITECT?S / ENGINEER?S | | | SIGNATURE AS APPLICABLE, STATING ?TO THE BEST OF THEIR | | | KNOWLEDGE THE PRODUCT APPROVAL COMPLIES WITH THE PLANS | | | AND SPECIFICATIONS.SEE:WEB SITE | | | WWW.FLORIDABUILDING.COM | | | NOTE: SEE DIVISION FACTOR TO BE USED IN DESIGN PRESSURE | | | BY LEGACYFPA | | | | | | PRODUCT APPROVALS | | | OUT SWING STEEL DOOR FLORIDA PRODUCT APPROVAL | | | MANUFACTURER IS SUBMITTED AS JELD-WEN | | | MIAMI-DADE PRODUCT APPROVAL NOTICES DOOR- CRAFT THE | | | ENGINEER OF RECORD DID NOT STAMP HIS ACCEPTANCE ON THE | | | MIAMI-DADE PRODUCT APPROVAL | | | STORM PANEL PRODUCT APPROVAL ONLY ONE COPY SUBMITTED | | | ALSO IDENTIFY WHICH SHUTTER IS BEING USED | | | PLEASE REVIEW EACH PRODUCT APPROVAL, ACKNOWLEDGE EACH | | | PRODUCT APPROVAL AS BEING ACCEPTED FOR THIS PROJECT AND | | | IDENTIFY WHICH PRODUCT IS BEING USED | | | | | | DETAIL 3-3.1 IDENTIFIES THE FOOTING TO BE PLACED IN THE | | | EXISTING SLAB, HOW WILL THE EXISTING FOOTING BE | | | ATTACHED TO ITSELF AFTER IT IS ISOLATED BY THE NEW | | | FOOTING? | | | | | | FURNISH TRUSS ENGINEERED DRAWINGS FOR REVIEW |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-06-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-06-11 |
Time |
12:45 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2007-06-11 |
Time |
10:49 |
Sent To |
PC |
|
| Notes |
| 2007-06-11 16:25:16 | BUILDING PLAN REVIEW | | | PERMIT: 07040094 | | | ADD: 1700 N DIXIE HWY | | | CONT: FRED BLAU & ASSOC | | | TEL: (561)309-7638 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR | | | YOUR ANTICIPATED COOPERATION. | | | | | | 2 ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT.NOTE: 713.13(2)IF THE | | | WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3 ) 110.2* W. P. B. ADMINISTRATIVE | | | CODE, INFORMATION THAT IS REQUIRED FOR | | | RECORD KEEPING & FOR CERTIFICATE OF | | | OCCUPANCY: | | | A) THE EDITION OF THE CODE UNDER WHICH | | | THE PROJECT ISDESIGNED. | | | NOTE: THE 2004 FBC W/ 2006REVISIONS ALSO SEE 2006 | | | EXISTING BUILDING CODE, PROVIDE WHAT LEVEL OF | | | ALTERATION TO BE COMPLETED UNDER THIS PERMIT. | | | SEE CHAPTER 6 FOR LEVEL II ALTERATIONS | | | AND CHAPTER 8 FOR CHANGE IN OCCUPANCY. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | | WITH THE PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | | IN CHAPTER 6, TABLE 601. | | | NOTE THIS WILL BE FOR THE COMPLETE BUILDING | | | (FOOTPRINT) , CONSISTING OF A 7,061 SQ FT TWO STORY, | | | 1,973 SQ FT CONCRETE PASS THROUGH AND 11,245 SQ FT | | | RENOVATION TO BE | | | COMPLETED UNDER THIS PERMIT.SEE DEFINITION OF | | | BUILDING AREA, (FOOTPRINT). PROVIDE ANY AREA INCREASES | | | IF TAKEN, PROVIDE CALCULATIONS. | | | D) THE OCCUPANT LOAD, SEE 1004. | | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS | | | PROVIDED, WHETHER THE SPRINKLER SYSTEM | | | IS REQUIRED. | | | F) ANY SPECIAL STIPULATIONS & CONDITIONS | | | OF THE BUILDING PERMIT. | | | G)NUMBER OF FLOORS | | | H) SQ. FT. FOOTPRINT | | | | | | 3) SHEET A-2 | | | 3A) GENERAL NOTE# 2 PLANS INDICATE CODE SECTION | | | 3401.8.2.3. PLEASE CORRECT AND UPDATE. | | | | | | 3B) GENERAL NOTE# 3 DRAFT STOPPING PER 705.3.2 PLEASE | | | CORRECT AND UPDATE. | | | | | | 3C) IS THERE TO BE A NEW FLOOR SLAB POURED AS WORK | | | COMPLETED UNDER THIS PERMIT. | | | | | | 3D) PLANS DO NOT INDICATE OR IDENTIFY THE ACCESSIBLE | | | ENTRANCE INTO THE BUILDING. SHEET A-3 DETAIL C DOES | | | INDICATE FROM GRADE A 4" SLAB WITH NO ACCESSIBLE ROUTE | | | OR ENTRANCE.2006 EXISTING BUILDING CODE, 806.1 GENERAL. | | | ACCESSIBILITY IN PORTIONS OF BUILDINGS UNDERGOING A | | | CHANGE OF OCCUPANCY CLASSIFICATION SHALL COMPLY WITH | | | CHAPTER 11 OF THE FLORIDA BUILDING CODE, BUILDING | | | 11-4.1.2 ( 1)AT LEAST ONE ACCESSIBLE ROUTE COMPLYING | | | WITH SECTION 11-4.3 SHALL BE PROVIDED WITHIN THE | | | BOUNDARY OF THE SITE FROM PUBLIC TRANSPORTATION STOPS, | | | ACCESSIBLE PARKING SPACES, PASSENGER LOADING ZONES IF | | | PROVIDED, AND PUBLIC STREETS OR SIDEWALKS, TO AN | | | ACCESSIBLE BUILDING ENTRANCE. | | | (2)AT LEAST ONE ACCESSIBLE ROUTE COMPLYING WITH | | | SECTION 11-4.3 SHALL CONNECT ACCESSIBLE BUILDINGS, | | | ACCESSIBLE FACILITIES, ACCESSIBLE ELEMENTS, AND | | | ACCESSIBLE SPACES THAT ARE ON THE SAME SITE. | | | | | | 3E) CHANGING ROOM 11-4.35.2 CLEAR FLOOR SPACE. | | | A CLEAR FLOOR SPACE ALLOWING A PERSON USING A | | | WHEELCHAIR TO MAKE A 180-DEGREE TURN SHALL BE PROVIDED | | | IN EVERY ACCESSIBLE DRESSING ROOM ENTERED THROUGH A | | | SWINGING OR SLIDING DOOR. NO DOOR SHALL SWING INTO ANY | | | PART OF THE TURNING SPACE. TURNING SPACE SHALL NOT BE | | | REQUIRED IN A PRIVATE DRESSING ROOM ENTERED THROUGH A | | | CURTAINED OPENING AT LEAST 32 INCHES (815 MM) WIDE IF | | | CLEAR FLOOR SPACE COMPLYING WITH SECTION 11-4.2 RENDERS | | | THE DRESSING ROOM USABLE BY A PERSON USING A | | | WHEELCHAIR. | | | | | | 11-4.35.3 DOORS. | | | ALL DOORS TO ACCESSIBLE DRESSING ROOMS SHALL BE IN | | | COMPLIANCE WITH SECTION 11-4.13 . | | | | | | 11-4.35.4 BENCH. | | | EVERY ACCESSIBLE DRESSING ROOM SHALL HAVE A 24 INCHES | | | BY 48 INCHES (610 MM BY 1219 MM) BENCH FIXED TO THE | | | WALL ALONG THE LONGER DIMENSION. THE BENCH SHALL BE | | | MOUNTED 17 INCHES TO 19 INCHES (430 MM TO 485 MM) | | | ABOVE THE FINISH FLOOR. CLEAR FLOOR SPACE SHALL BE | | | PROVIDED ALONGSIDE THE BENCH TO ALLOW A PERSON USING A | | | WHEELCHAIR TO MAKE A PARALLEL TRANSFER ONTO THE BENCH. | | | THE STRUCTURAL STRENGTH OF THE BENCH AND ATTACHMENTS | | | SHALL COMPLY WITH SECTION 11-4.26.3 . WHERE INSTALLED | | | IN | | | CONJUNCTION WITH SHOWERS, SWIMMING POOLS, OR OTHER WET | | | LOCATIONS, WATER SHALL NOT ACCUMULATE UPON THE SURFACE | | | OF THE BENCH AND THE BENCH SHALL HAVE A SLIP-RESISTANT | | | SURFACE. | | | | | | 11-4.35.5 MIRROR. | | | WHERE MIRRORS ARE PROVIDED IN DRESSING ROOMS OF THE | | | SAME USE, THEN IN AN ACCESSIBLE DRESSING ROOM, A | | | FULL-LENGTH MIRROR, MEASURING AT LEAST 18 INCHES WIDE | | | BY 54 INCHES HIGH (460 MM BY 1370 MM), SHALL BE MOUNTED | | | IN A POSITION AFFORDING A VIEW TO A PERSON ON THE BENCH | | | AS WELL AS TO A PERSON IN A STANDING POSITION. | | | | | | 3E) NEW HANDICAPPED RESTROOM, WALL FINISHES:1210.1 IN | | | OTHER THAN DWELLING UNITS, TOILET AND BATHING ROOM | | | FLOORS SHALL HAVE A SMOOTH, HARD, NONABSORBENT SURFACE | | | THAT EXTENDS UPWARD ONTO THE WALLS AT LEAST 6 INCHES | | | (152 MM). | | | | | | 1210.2 WALLS. | | | WALLS WITHIN 2 FEET (610 MM) OF URINALS AND WATER | | | CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT | | | SURFACE, TO A HEIGHT OF 4 FEET (1219 MM) ABOVE THE | | | FLOOR, AND EXCEPT FOR STRUCTURAL ELEMENTS, THE | | | MATERIALS USED IN SUCH WALLS SHALL BE OF A TYPE THAT IS | | | NOT ADVERSELY AFFECTED BY MOISTURE. | | | | | | 3F) THE STORAGE AREA WITHIN THENEW THRIFT STORE | | | PLEASE DECLARE IF TYPE S1 OR S2?TABLE 302.3.2. | | | | | | 4)2006 FL EXISTING BUILDING CODE- 812.1 COMPLIANCE | | | WITH CHAPTER 7 . THE OCCUPANCY CLASSIFICATION OF AN | | | EXISTING BUILDING MAY BE CHANGED, PROVIDED THAT THE | | | BUILDING MEETS ALL OF THE REQUIREMENTS OF CHAPTER 7 | | | APPLIED THROUGHOUT THE BUILDING FOR THE NEW OCCUPANCY | | | GROUP AND COMPLIES WITH THE REQUIREMENTS OF SECTIONS | | | 802 THROUGH 812 . | | | 2006 FL EXISTING BUILDING CODE, CHAPTER 7 LEVEL III | | | ALTERATION 708.1 MINIMUM REQUIREMENTS. ALTERATIONS | | | SUBJECT TO THIS CHAPTER SHALL COMPLY WITH THE | | | REQUIREMENTS OF CHAPTER 13 OF THE FLORIDA BUILDING | | | CODE, BUILDING. SEE A-3 DETAILC DOESN'T INDICATE ANY | | | ROOF INSULATION. | | | | | | 5) ENERGY CALCS ARE MISSING THE DESIGN PROFESSIONAL | | | SEAL & SIGNATURE. | | | PLANS, SPECIFICATIONS, REPORTS OR | | | OTHER DOCUMENTS PREPARED BY THE DESIGN | | | PROFESSIONAL AND BEING FILED FOR PUBLIC | | | RECORD SHALL HAVE THE SIGNATURE AND | | | SEAL OF THE DESIGN PROFESSIONAL AFFIXED | | | TO THE DOCUMENT. | | | FL STATE STAT: 61G15-23.002 ENGINEERS | | | FL ATATE STAT: 61G16.003 ARCHITECTS | | | | | | 6)FL BLD CODE 1609.1.4: COMPONENTS & CLADDING, | | | PROVIDE 2 COPIES(3 IF THRESHOLD OR RESIDENT INSPECTOR) | | | OF PRODUCT TESTING REPORTS ,MISSING REPORTS ARE AS | | | FOLLOWS: | | | 6 A) JELD-WEN DOOR THE WRONG MIAMI-DADE WAS SUBMITTED | | | THAT TIES TO THE FL NUMBER | | | 6 B) STORM PANELS- ADDITIOAL INFORMATION REQUIRED: | | | PROVIDE STORM PANEL INFORMATION WITH INSTALLATION | | | SCHEDULE AND KEY PLAN WITH | | | SPECIFIC ANCHORS AND MOUNTING TO BE USED FOR ALL | | | NON-IMPACT GLAZING. | | | FBC 1606.1.4. | | | | | | FL BLD CODE 2004SECTION 103.6, | | | 1606.1.4, 1707.4 & 3401.7.2.4. | | | PROCEDURES: 1(B) A COMPLETE INSTALLATION | | | SCHEDULE SUMMARIZING & IDENTIFYING | | | OPENING SIZES, STORY HEIGHTS, UNIT MARK | | | NUMBERS, UNIT SPANS/WIDTHS, UNIT STORM | | | BAR REINFORCING REQUIREMENTS, WALL PRES- | | | SURE ZONES, SLAT TYPES, ETC., SHALL BE | | | SUBMITTED AT TIME OF PERMIT APPLICATION | | | TO FACILITATE PLAN REVIEW AND PERMIT | | | ISSUANCE. | | | | | | C) TAMKO ROOFING ) THIS ROOF IS MISSING OR NOT IN | | | COMPLIANCE WITH THE FOLLOW ITEMS: | | | | | | _X__ THE SYSTEM PROVIDED HAS A LOW | | | PRESSURE FOR ZONE _2&3__ . | | | | | | _X__ THE SYSTEM PROVIDED STATES | | | LIMITATION# 7, SHOULD THE FASTENER | | | RESISTANCE BE LESS THAN THAT | | | REQUIRED, AS DETERMINED BY THE | | | BUILDING OFFICIAL, A REVISED | | | FASTENER SPACING, PREPARED , SIGNED | | | AND SEALED BY A FLORIDA REGISTERED | | | PROFESSIONAL ENGINEER, REGISTERED | | | ARCHITECT OR REGISTERED ROOF | | | CONSULTANT MAY BE SUBMITTED. | | | | | | 7)BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL | | | INFORMATION REQUESTED ADDITIONAL COMMENTS MAY APPEAR | | | THAT WERE NOT PART OF THIS REVIEW. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2008-05-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2008-05-04 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2008-05-04 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2008-05-04 11:22:58 | ** DENIED 3RD REVIEW ** | | | | | | ** PLEASE SEE SOME ITEMS FROM PREVIOUS REVIEW ARE STILL | | | IN NEED OF ADDRESSING ALONG WITH NEW COMMENT(S) WHICH | | | ARE BASED ON NEW DOCUMENTS NOW SUBMITTED. | | | | | | 1) NOTE: PLEASE SEE 13-400.3.A AS THE VERSION OF THE | | | SUBMITTED ENERGY CALCULATIONS MAY NOT BE USED. | | | PLEASE KNOW VERSION 2.5 IS THE ADOPTED VERSION WHICH | | | INCORPORATES ENERGY GAUGE SUMMIT 3.0-3.14. THIS VERSION | | | IS STILL 2.5 AS ADOPTED. THIS HAS BEEN CONFIRMED WITH | | | THE DEPARTMENT OF COMMUNITY AFFAIRS/FLORIDA BUILDING | | | COMMISSION. | | | ** PLEASE ALSO SEE THAT THE CALCULATIONS SUBMITTED ARE | | | NOT COMPLETE. PLEASE SEE THE INPUT DATA REPORT WAS NOT | | | SUBMITTED WHICH IS ESSENTIAL TO THE REVIEW FOR CODE | | | COMPLIANCE. PLEASE SEE SHEET #2 ON THE SUMMARY SHEETS | | | WHICH SPECIFICALLY STATES THE INPUT DATA REPORT MUST | | | ACCOMPANY THE CALCULATIONS. | | | ** PLEASE BE SURE ALL COMPONENTS OF THE BUILDING IS | | | SHOWN ON THE IDR. PLEASE KNOW AS THIS BUILDING IS AN | | | EXISTING BUILDING THE ONLY WAY TO USE METHOD A IS ALL | | | COMPONENTS MUST MEET CURRENT CODES FOR INSULATIONS, | | | WINDOWS ETC. ALL MUST BE PLACED INTO THE CALCULATIONS. | | | PLEASE SEE 13-400.3.B, 13-101.1.3 AS THIS BUILDING DOES | | | FALL UNDER THE DEFINITION OF A RENOVATION. PLEASE SEE | | | THE CODE, AS A RENOVATION METHOD B OR C IS STATED. | | | ** THIS IS IMPORTANT, METHOD *A* MAY ONLY BE USED IF | | | ALL COMPONENTS ARE KNOWN AND MEET CURRENT CODE FOR | | | TRADE OFF ALLOWANCES FOR *WHOLE BUILDING* ETC. | | | THIS COMMENT IS FOR ALL TRADES WHETHER OR NOT COMMENT | | | IS MADE BY ANY OTHER REVIEWER(S). | | | PLEASE BE SURE TO SEE 13-415.2 FOR LIGHTING | | | PERFORMANCE. PLEASE SEE 13-415.2.ABC.1.1, .1.2 AND | | | .1.3. | | | THIS OFFICE CAN NOT EMPHASIZE ENOUGH TO PLEASE BE SURE | | | ALL LIGHTING AND OTHER COMPONENTS ON PLANS COORDINATE | | | WITH THE SUBMITTED ENERGY CALCULATIONS AND THE INPUT | | | DATA REPORT. | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | | | PLEASE BE SURE THE OWNER/AGENT HAS SIGNED THE | | | COMPLIANCE CERTIFICATION SHEETS. | | | | | | 2) NOTE: PLEASE SEE FPL STANDARDS OF METERING. PLEASE | | | VERIFY WITH A FPL SERVICE PLANNER THAT ALL METERING | | | DEVICES ARE GROUPED. AS THE RISER DOES NOT SHOW ANY | | | METERING FOR INDIVIDUAL MAINS THIS CAN NOT BE VERIFIED | | | AT THIS TIME. | | | | | | 3) NOTE: PLEASE SEE THE RISER HAS NOW INCLUDED | | | CONDUCTORS FROM GUTTER TO THE MAIN HOWEVER PLEASE SEE | | | THAT AN * EQUIPMENT GROUNDING CONDUCTOR* IS NOW BEING | | | SHOWN WHICH IS NOT PERMITTED PER 250.6, 250.24. | | | AS THE GROUNDED CONDUCTOR IS REQUIRED TO BE BONDED AT | | | THE FIRST MEANS OF DISCONNECT IF AN EQUIPMENT GROUNDING | | | CONDUCTOR WAS INSTALLED THIS WOULD PARALLEL THE NEUTRAL | | | WHICH CREATES *OBJECTIONABLE CURRENTS*. | | | PLEASE VERIFY ACTUAL FIRST MEANS OF DISCONNECT AND | | | ADJUST. | | | | | | ** THIS OFFICE EXPRESSES THAT IF THERE ARE ANY | | | COMMENTS, QUESTIONS OR CLARIFICATION NEEDED TO PLEASE | | | DO NOT HESITATE IN CONTACTING THIS OFFICE. | | | PLEASE SEE BELOW FOR CONTACT INFORMATION. | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE PICKED UP FOR | | | CORRECTIONS, PLEASE BE SURE TO COMPLETELY REMOVE ALL | | | OLD/VOIDED SHEETS AND ONLY INSERT NEW REVISED SHEETS | | | INTO TWO COMPLETE SETS FOR REVIEW AND STAMPING. DO NOT | | | LEAVE ANY OLD/VOIDED SHEETS IN SETS. | | | PLEASE DO NOT ATTACH SUPPORTING DOCUMENTS TO PLANS. ANY | | | ADDITIONAL DOCUMENTATION SUCH AS PRODUCT APPROVALS, | | | SPEC/CUT SHEETS, CALCULATIONS ETC SHOULD BE PLACED INTO | | | TWO SETS/FOLDERS/BINDERS ETC. | | | PLEASE KNOW ONLY ONE SET OF THE OLD/VOIDED SHEETS | | | SHOULD BE SUBMITTED FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND AVOID ANY | | | DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPARTMENT | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-08-29 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-08-29 |
Time |
19:51 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-08-29 |
Time |
19:10 |
Sent To |
|
|
| Notes |
| 2007-08-29 19:51:55 | 2007-08-29 19:51:55 | | | | | | ** DENIED2ND REVIEW** | | | | | | 1) NOTE: PLEASE SEE THE PREVIOUS REVIEW NOTE #2 WHICH | | | SPECIFICALLY GAVE A *HEADS-UP* ON THE ENERGY | | | CALCULATIONS. | | | PLEASE BE SURE WHEN SUBMITTING THE INPUT DATA REPORT | | | THAT THE INFORMATION SHOWN ON THIS REPORT COORDINATES | | | WITH THE NUMBER OF FIXTURES ON PLANS, THE TOTAL WATTAGE | | | OF EACH FIXTURE AND THE METHOD FO CONTROLS. | | | PLEASE SEE THE LUMINARIES SHOWN ON THE PLANS DO NOT | | | MATCH WITH THE IDR. | | | PLEASE SEE THE TYPE OF INPUT FOR *HOTEL/MOTEL* WHICH IS | | | NOT POSSIBLE. | | | PLEASE SEE THE METHOD OF CONTROLS IS BEING SHOWN AS | | | *MANUAL ON/OFF* ON THE INPUT DATA REPORT HOWEVER | | | AUTOMATE CONTROLS ARE SHOWN ON PLANS. PLEASE COORDINATE | | | PLANS WITH THE CALCULATIONS. | | | PLEASE ALSO SEE THE NEW REVISED ENERGY CALCULATIONS | | | WHICH ARE NOT SIGNED, DATED AND SEALED AS REQUIRED PER | | | FBC 13-103.1.1.1, FS 471.025, FAC 61G15-23.002 | | | | | | 2) NOTE: PLEASE SEE MISSING LIGHT FIXTURE WHICH IS | | | REDLINED ON PLANS. | | | FBC 106.1.2 | | | | | | 3) NOTE: PLEASE INDICATE LOAD ON THE EXISTING GUTTER | | | FOR ADDING NEW LOADS. | | | NEC 220 | | | FBC 106.3.5.1.2 | | | | | | 4) NOTE: PLEASE SEE NO CONDUCTORS ARE BEING SHOWN FROM | | | GUTTER TO NEW MAIN. | | | 230, 310.16, 240.4, ETC | | | FBC 106.3.5.1.2 | | | | | | 5) NOTE: PLEASE SEE MISSING NEUTRAL TO THE MEANS OF | | | DISCONNECT AT THE DETACHED BUILDING. | | | 250.32 | | | EVEN AS A NEUTRAL IS NOT NEEDED FROM THE MAIN AT THE | | | DETACHED BUILDING TO THE TRANSFORMER FOR THE SEPARATELY | | | DERIVED SYSTEM, A NEUTRAL IS STILL REQUIRED TO THE | | | MAIN. | | | PLEASE SEE MISSING COLD WATER PIPE AT THE DETACHED | | | STRUCTURE PER 250.50 | | | PLEASE VERIFY THE GROUNDING ELECTRODE FOR THE | | | TRANSFORMER PER 250.58. | | | | | | AS STATED ON THE PREVIOUS REVIEW: | | | PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-04-16 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-04-16 |
Time |
07:37 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-04-15 |
Time |
19:59 |
Sent To |
|
|
| Notes |
| 2007-04-16 07:38:35 | ** UNSAT ** | | | | | | ** PLEASE SEE ANY REFERENCES IN PLAN REVIEW NOTES TO | | | CHAPTER 1 OF THE FBC ARE THAT WHICH IS ADOPTED BY THE | | | CITY OF WEST PALM BEACH. | | | | | | 1) NOTE: PLEASE KNOW THAT ANY PERMIT APPLICATIONS WHICH | | | ARE SUBMITTED AFTER DECEMBER 8TH, 2006 PLACES PROJECTS | | | UNDER THE NEW CODES ADOPTED BY THE STATE. | | | PLANS AT THIS TIME DO NOT INDICATE ANY CODES. | | | PLEASE SEE THAT THIS SHALL INCLUDE 2006 REVISIONS TO | | | THE 2004 FBC FOR ALL TRADES AND THE 2005 NFPA-70. | | | PLEASE KNOW THERE ARE CHANGES IN THE FBC WHICH MAY | | | AFFECT DESIGNS FOR ALL TRADES. | | | PLEASE LIST THE FOLLOWING ON ELECTRICAL SHEETS FOR THIS | | | REVIEWER AT A MINIMUM. | | | 2004 FBC W/ 2006 REVISIONS | | | 2005 NFPA-70 | | | 2003 NFPA-101 | | | | | | 2) NOTE: PLEASE COMPLETE THE ENERGY CALCULATIONS | | | SUBMITTED. 13-415.1.AB.1.1, 13-415.2 | | | PLEASE SEE THE SQ FT ON THE ENERGY CALCULATIONS DOES | | | NOT CORRELATE WITH PLANS. | | | PLEASE BE SURE TO SUBMIT THE *INPUT DATA REPORT* ALONG | | | WITH FRONT SHEET(S) FOR PROJECT SUMMARY. (NOTE: THE | | | CALCULATIONS ARE NOT VALID WITHOUT THE INPUT DATA | | | REPORT) | | | PLEASE BE SURE THE ENERGY CALCULATIONS ARE SIGNED, | | | DATED AND SEALED BY THE RESPONSIBLE DESIGNER OF | | | RECORD.13-103.1.1.1 | | | PLEASE BE SURE THAT ALL LIGHTING FIXTURES, WATTAGES ETC | | | COORDINATE WITH THE ELECTRICAL PLANS. | | | PLEASE THE BASED ON THE LIGHTING POWER DENSITIES NOTED | | | ON PLANS, THESE MENTION *X* WATTAGE PROVIDED, YET BASED | | | ON THE FIXTURE LEGEND AND THE FIXTURE WATTAGES, THE LPD | | | SEEMS TO BE HIGHER THAN THE AMOUNT SHOULD BE BASED ON | | | THE FIXTURES AND WATTAGES LISTED. | | | PLEASE SUBMIT A DETAIL ON LIGHTING CONTROL PANEL AS | | | NOTED ON PLANS. THE REQUIRED LOCATIONS OF OVER RIDES | | | FOR POINTS OF INGRESS AND EGRESS COULD NOT BE LOCATED | | | AT THESE DOORS. ONLY ONE TIMER TYPE WAS FOUND ON PLANS. | | | 13-415.1.ABC.1.1 | | | PLEASE INDICATE THE MAXIMUM AMOUNT OF TIME ON THE OC | | | TYPE DEVICES AS LISTED ON THE SYMBOL. | | | PLEASE SEE THE STORAGE AREA WHICH CONTAINS WALL MOUNTED | | | TYPE OCCUPANCY TYPE DEVICES ARE OK AS LONG AS COVERAGE | | | FOR THE AREA IS MET. IF THIS IS A STORAGE AREA, HOW | | | WILL A WALL MOUNTED DEVICE PROVIDE COVERAGE FOR THE | | | OCCUPANTS? ARE THESE COMBINATION TYPE DEVICES? | | | PLEASE KNOW THAT IN THE EVENT OF THE BUILDING BEING | | | OCCUPIED AFTER HOURS AND THE TIMER TYPE DEVICE TURNS | | | OFF, WHAT LIGHTING WILL AN OCCUPANT HAVE TO MAKE THEIR | | | WAY SAFETY TO TURN LIGHTING BACK ON? WILL THERE BE A | | | *NIGHT LIGHT* OR WILL AN OCCUPANCY TYPE DEVICE PROVIDE | | | THAT COVERAGE? ONLY ONE *NL* INDICATE IN THE FRONT PART | | | OF THE BUILDING IN RETAIL AREA. | | | PLEASE CONSIDER. | | | PLEASE SEE ALL OF THE NEW 2004 FBC W/2006 REVISIONS AS | | | THERE WERE CHANGES FORM THE PREVIOUS 05, 2004 FBC. | | | 13-415.1.ABC.1.1, .1.2 AND .1.3 | | | | | | 3) NOTE: PLEASE SEE THE PLANS SEEM TO INDICATE THE MAIN | | | SERVICE AND DISCONNECT LOCATED ON A DIFFERENT BUILDING. | | | WHERE IS THE GUTTER AND DISCONNECTS LOCATED? PLEASE SEE | | | 225.31-225.39 | | | | | | 4) NOTE: PLEASE SEE 250.32 FOR GROUNDING AT DETACHED | | | BUILDINGS. AS THE LOCATION OF THE SERVICE IS NOT CLEAR | | | AND THE MAIN SERVICE IS BEING SHOWN AT A DETACHED | | | BUILDING, PLEASE SUBMIT THE DETAIL ON RISER. | | | | | | 5) NOTE: PLEASE COMPLETE PANEL SCHEDULE FOR LIGHTING | | | AND RECEPTACLES. | | | PLEASE SEE THE FOLLOWING TEXT WHICH IS FROM THE 2005 | | | NEC 408.4. | | | **SECTION 408.4 WAS REVISED FOR THE 2005 CODE TO | | | REQUIRE THAT THE IDENTIFICATION FOR EVERY CIRCUIT | | | SUPPLIED BY A PANEL-BOARD OR SWITCHBOARD BE LEGIBLE AND | | | CLEARLY STATE THE SPECIFIC PURPOSE FOR WHICH THE | | | CIRCUIT IS USED. CIRCUITS USED FOR THE SAME PURPOSE | | | MUST BE IDENTIFIED AS TO THEIR LOCATION. FOR EXAMPLE, | | | SMALL APPLIANCE BRANCH CIRCUITS CAN SUPPLY OUTLETS IN | | | THE KITCHEN, DINING ROOM, AND KITCHEN COUNTERTOPS. | | | IDENTIFYING THE CIRCUITS AS SMALL APPLIANCE BRANCH | | | CIRCUITS IS NOT ACCEPTABLE; INSTEAD, THEY SHOULD BE | | | IDENTIFIED AS ``KITCHEN WALL RECEPTACLES,'' ``DINING | | | ROOM FLOOR RECEPTACLE,'' OR ``KITCHEN COUNTERTOP | | | RECEPTACLES LEFT OF SINK.'' CIRCUIT DIRECTORIES | | | CONTAINING MULTIPLE ENTRIES WITH ONLY ``LIGHTS'' OR | | | ``OUTLETS'' DO NOT PROVIDE THE SUFFICIENT DETAIL | | | REQUIRED BY THIS SECTION.* | | | 408.4, 310.16, 240.4 ETC | | | FBC 106.3.5..1.2 | | | | | | 6) NOTE: PLEASE SEE THE NOTES INDICATE WIRING FOR EM | | | AND EXTLTS TO BE PER 700.12F, YET THIS SHOULD BE | | | 700.12E. THE *F* SEEMS TO BE A MISPRINT). | | | | | | ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-04-16 07:04:08 | 2007-04-16 07:04:08 | | | IN REVIEW | | 2007-04-15 20:07:49 | 2007-04-15 20:07:49 | | | REVIEW TO CONTINUE ON 4/16 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2008-05-19 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-05-19 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-05-19 |
Time |
12:18 |
Sent To |
|
|
| Notes |
| 2008-05-19 12:43:34 | *****DENIED***** | | | | | | * THE FOLLOWING COMMENTS TAKEN FROM THE PREVIOUS FIRE | | | PLAN REVIEWS STILL NEED TO BE ADDRESSED: | | | | | | | | | 7.SPECIFY THE INTERIOR WALL AND CEILING FINISH | | | MATERIAL AS CLASS A, CLASS B, OR CLASS C FOR EXITS, | | | EXIT ACCESS CORRIDORS, AND ALL OTHER AREAS.PLEASE | | | ADDRESS ON THE APPROPIATE PLAN SHEET | | | | | | * NEW COMMENTS | | | | | | C.PROVIDE A LAYOUT OF THE SPRINKLER SYSTEM FOR | | | STRUCTURE.PLEASE BE ADVISED THAT SEPARATE PLANS AND | | | PERMIT WILL BE REQUIRED FOR SPRINKLER INSTALLATION | | | AND/OR REMODEL. | | | | | | D. DOES THE STRUCTURE HAVE OR WILL HAVE A FIRE ALARM | | | SYSTEM.IF SO, PROVIDE A LAYOUT OF THE FIRE ALARM | | | SYSTEM.PLEASE BE ADVISED THAT SEPARATE PLANS AND | | | PERMIT WILL BE REQUIRED FOR ITS INSTALLATION AND/OR | | | REMODEL. | | | | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH COMMENT WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2007-09-25 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-09-25 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-09-25 |
Time |
09:14 |
Sent To |
|
|
| Notes |
| 2007-09-25 10:46:41 | *****DENIED***** | | | | | | * THE FOLLOWING COMMENTS TAKEN FROM THE PREVIOUS FIRE | | | PLAN REVIEW STILL NEED TO BE ADDRESSED: | | | | | | 4.THE DEMOLITION AND/OR THE STOCKING OF NEW BUILDING | | | MATERIALS & SUPPLIES SHALL NOT INTERFERE WITH EMERGENCY | | | RESPONSE ACCESS TO THE PROPERTY OR THE VICINITY THEREOF | | | (INCLUDING STREETS, ALLEYS, FIRE LANES).AMEND | | | SPELLING TO READ FIRE LANES, NOT FINE LINES AS | | | INDICATED ON SHEET 2.1 | | | | | | 5.PLEASE DECLARE THE OCCUPANCY CLASSIFICATION FOR | | | THIS/THESE STRUCTURE(S).NOT SHOWN IN THE PROJECT DATA | | | ON SHEET 2.1 | | | | | | 7.SPECIFY THE INTERIOR WALL AND CEILING FINISH | | | MATERIAL AS CLASS A, CLASS B, OR CLASS C FOR EXITS, | | | EXIT ACCESS CORRIDORS, AND ALL OTHER AREAS.PLEASE | | | ADDRESS ON THE APPROPIATE PLAN SHEET | | | | | | * NEW COMMENTS | | | | | | A.DECLARE WHAT IS TO BE STORED IN THE NEW STORAGE | | | STRUCTURE AND ITS HAZARD CONTENTS IN TERMS OF LOW, | | | MODERATE, OR HIGH. | | | | | | B.NO EMERGENCY LIGHTS NOTED IN THE NEW STORAGE | | | STRUCTURE.PLEASE EXPLAIN OR AMEND. | | | | | | C.PROVIDE A LAYOUT OF THE SPRINKLER SYSTEM FOR | | | STRUCTURE.PLEASE BE ADVISED THAT SEPARATE PLANS AND | | | PERMIT WILL BE REQUIRED FOR SPRINKLER INSTALLATION | | | AND/OR REMODEL. | | | | | | D. DOES THE STRUCTURE HAVE OR WILL HAVE A FIRE ALARM | | | SYSTEM.IF SO, PROVIDE A LAYOUT OF THE FIRE ALARM | | | SYSTEM.PLEASE BE ADVISED THAT SEPARATE PLANS AND | | | PERMIT WILL BE REQUIRED FOR ITS INSTALLATION AND/OR | | | REMODEL. | | | | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH COMMENT WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-05-30 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-05-30 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-05-30 |
Time |
15:37 |
Sent To |
|
|
| Notes |
| 2007-05-30 16:31:55 | *****DENIED***** | | | | | | | | | 1.PROVIDE A SITE PLAN WHICH WOULD RELAY THE LOCATION | | | OF BUILDING TO SURROUNDING STREETS, ROADS, ETC | | | | | | 2.NFPA 101, THE LIFE SAFETY CODE, 2003 EDITION SHALL | | | BE REFERENCED. | | | | | | 3.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 4.THE DEMOLITION AND/OR THE STOCKING OF NEW BUILDING | | | MATERIALS & SUPPLIES SHALL NOT INTERFERE WITH EMERGENCY | | | RESPONSE ACCESS TO THE PROPERTY OR THE VICINITY THEREOF | | | (INCLUDING STREETS, ALLEYS, FIRE LANES). | | | | | | 5.PLEASE DECLARE THE OCCUPANCY CLASSIFICATION FOR | | | THIS/THESE STRUCTURE(S). | | | | | | 6.PLEASE PROVIDE OCCUPANT LOAD/EGRESS REQUIREMENTS | | | | | | 7.SPECIFY THE INTERIOR WALL AND CEILING FINISH | | | MATERIAL AS CLASS A, CLASS B, OR CLASS C FOR EXITS, | | | EXIT ACCESS CORRIDORS, AND ALL OTHER AREAS. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH COMMENT WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2008-04-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-22 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-22 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2008-04-22 10:04:45 | TO "COMM" BD#62 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-08-06 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-06 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-06 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2007-08-29 14:50:35 | TO "COMM" BD#24 | | 2007-08-06 16:25:54 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-06-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-06-11 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2007-04-03 |
Time |
17:51 |
Sent To |
|
|
| Notes |
| 2007-04-04 18:01:01 | TO COMM BOARD # 13 | | 2007-04-03 17:51:49 | WAITING FOR COMM BOARD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2008-05-01 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2008-05-01 |
Time |
08:32 |
Rev Time |
1.00 |
| Received By |
tgordon |
Date |
2008-05-01 |
Time |
08:32 |
Sent To |
|
|
| Notes |
| 2008-05-01 08:32:45 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2005, 2006 REVISIONS, AND CHAPTER | | | 1 CITY OF WEST PALM BEACH AMENDMENTS. | | | | | | *** DENIED *** | | | 1) THE SIGNATURE OF THE PREPARER ON THE ENERGY | | | CALCULATIONS CAN NOT BE READ TO DETERMINE WHO'S SIGNED. | | | AS NOTED IN LAST TWO REVIEWS 5-1-07 NOTE #3 AND 8-20-07 | | | NOTE #1. ENERGY CALCULATIONS "PREPARED BY" NEED TO BE | | | SIGNED AND SEALED BY AN ARCHITECT OR ENGINEER, SEE 2004 | | | FBC 13-103.1.1.1 EXCEPTION. | | | | | | *** 2004 FBC 13-103.1.1.1 ENERGY CALCULATIONS | | | COMMERCIAL APPLICATIONS. COMPLETION OF PROCEDURES | | | DEMONSTRATING COMPLIANCE WITH THIS CODE FOR COMMERCIAL | | | BUILDINGS SHALL BE SIGNED AND SEALED BY AN ARCHITECT OR | | | ENGINEER LICENSED TO PRACTICE IN THE STATE OF FLORIDA, | | | WITH THE EXCEPTION OF BUILDINGS EXCLUDED BY SECTION | | | 481.229, FLORIDA STATUTES , OR SECTION 471.003, FLORIDA | | | STATUTES. CALCULATIONS FOR BUILDINGS FALLING WITHIN THE | | | EXCEPTION OF SECTION 471.003, FLORIDA STATUTES , MAY BE | | | PERFORMED BY AIR CONDITIONING OR MECHANICAL CONTRACTORS | | | LICENSED IN ACCORDANCE WITH CHAPTER 489, FLORIDA | | | STATUTES , OR BY STATE OF FLORIDA CERTIFIED COMMERCIAL | | | BUILDING ENERGY RATERS. | | | DESIGN PROFESSIONALS RESPONSIBLE UNDER FLORIDA LAW FOR | | | THE DESIGN OF LIGHTING, ELECTRICAL, MECHANICAL, AND | | | PLUMBING SYSTEMS AND THE BUILDING SHELL, SHALL CERTIFY | | | COMPLIANCE OF THOSE BUILDING SYSTEMS WITH THE CODE BY | | | SIGNING AND PROVIDING THEIR PROFESSIONAL REGISTRATION | | | NUMBER ON THE ENERGY CODE FORM PROVIDED AS PART OF THE | | | PLANS AND SPECIFICATIONS TO THE BUILDING DEPARTMENT. | | | EXCEPTION: TYPED NAMES AND REGISTRATION NUMBERS MAY BE | | | PROVIDED IN LIEU OF A SIGNATURE WHERE ALL RELEVANT | | | INFORMATION HAS BEEN INCLUDED ON SIGNED AND SEALED | | | PLANS. | | | | | | 2) AS NOTED IN LAST TWO REVIEWS 5-1-07 NOTE #4 AND | | | 8-20-07 NOTE #2. ENERGY CALCULATIONS NEED A "MECHANICAL | | | DESIGNER" WHO IS A ENGINEER, OR AN ARCHITECT, AIR | | | CONDITIONING CONTRACTOR, OR MECHANICAL CONTRACTOR IF | | | APPLICABLE, SEE 2004 FBC 13-103.1.1.1 AND F.S. 471.003 | | | (H). (NOT NELSON MARIN). | | | | | | 3) AS NOTED IN LAST TWO REVIEWS 5-1-07 NOTE #5 AND | | | 4-20-07 NOTE #3. SEE MECHANICAL PLANS, TITLE BLOCK, | | | (NELSON MARIN) IF NOT A LICENSE ENGINEER MAY NOT DO | | | COMMERCIAL MECHANICAL PLANS, SEE F.S. 471.003. IF A | | | LICENSE ENGINEER THEN HE NEEDS TO PUT HIS INFORMATION | | | IN THE TITLE BLOCK, SEE FAC 61G15-23.002. LICENSE | | | #CAC055529 BELONGS TO JERONIMO MARIN (NOT NELSON MARIN) | | | PLEASE HAVE JERONIMO MARIN SIGN MECHANICAL PLANS. | | | | | | 4) AS NOTED IN LAST TWO REVIEWS 5-1-07 NOTE #6 AND | | | 8-20-07 NOTE #4. THE COMMERCIAL MECHANICAL PLANS NEED | | | TO BE DONE BY AN ENGINEER, OR A/C CONTRACTOR, | | | MECHANICAL CONTRACTOR IF APPLICABLE, SEE F.S. 471.003. | | | (NOT NELSON MARIN) PLEASE HAVE JERONIMO MARIN SIGN | | | MECHANICAL PLANS. | | | | | | 5) AS NOTED IN LAST TWO REVIEWS 5-1-07 NOTE #2 AND | | | 8-20-07 NOTE #5. PLEASE PROVIDE OUTDOOR AIR | | | CALCULATIONS, AND OUTDOOR AIR, SEE 2004 FBC/M 403.1. | | | (NEED TO SHOW THE CALCULATIONS ON THE MECHANICAL PLAN | | | NOT JUST SHOW A FRESH AIR VENT). | | | | | | 6) AS NOTED IN LAST REVIEW 8-20-07 NOTE #8.PLEASE | | | SUBMIT COOLING LOAD CALCULATIONS, SEE 2004 FBC | | | 13-407.1.ABC.1. | | | | | | 7)ENERGY CALCULATIONS NEED TO BE SIGNED BY | | | OWNER/AGENT ALSO, PER 2004 FBC 13-103.3. | | | | | | 8) INPUT REPORT PRINT-OUT IS MISSING FROM THE ENERGY | | | CALCULATIONS (SHOWING THE WALL INSULATION) PLEASE | | | CORRECT. | | | | | | 9) ONLY ONE SET OF PLANS HAVE A MECHANICAL PLAN PAGE | | | M-1 IN THEM BOTH SETS NEED TO HAVE A MECHANICAL PLAN | | | WITH THEM, SEE 2004 FBC 106.3.5. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL: [email protected]. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-08-20 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-08-20 |
Time |
08:47 |
Rev Time |
0.45 |
| Received By |
tgordon |
Date |
2007-08-20 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2007-08-20 15:51:05 | RETURNED TO INCOMING WAITING TO GET ON COMM. BOARD. | | 2007-08-20 08:57:07 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 2005, 2006 REVISIONS, AND CHAPTER | | | 1 CITY OF WEST PALM BEACH AMENDMENTS. | | | | | | *** DENIED *** | | | 1) AS NOTED IN LAST REVIEW 5-1-07NOTE #3. ENERGY | | | CALCULATIONS "PREPARED BY" NEED TO BE SIGNED AND SEALED | | | BY AN ARCHITECT OR ENGINEER, SEE 2004 FBC 13-103.1.1.1. | | | (NOT NELSON MARIN). | | | | | | 2) AS NOTED IN LAST REVIEW 5-1-07 NOTE #4. ENERGY | | | CALCULATIONS NEED A "MECHANICAL DESIGNER" WHO IS A | | | ENGINEER, OR AN ARCHITECT, AIR CONDITIONING CONTRACTOR, | | | OR MECHANICAL CONTRACTOR IF APPLICABLE, SEE 2004 FBC | | | 13-103.1.1.1 AND F.S. 471.003 (H). (NOT NELSON MARIN). | | | | | | *** 2004 FBC 13-103.1.1.1 COMMERCIAL APPLICATIONS. | | | COMPLETION OF PROCEDURES DEMONSTRATING COMPLIANCE WITH | | | THIS CODE FOR COMMERCIAL BUILDINGS SHALL BE SIGNED AND | | | SEALED BY AN ARCHITECT OR ENGINEER LICENSED TO PRACTICE | | | IN THE STATE OF FLORIDA, WITH THE EXCEPTION OF | | | BUILDINGS EXCLUDED BY SECTION 481.229, FLORIDA STATUTES | | | , OR SECTION 471.003, FLORIDA STATUTES. CALCULATIONS | | | FOR BUILDINGS FALLING WITHIN THE EXCEPTION OF SECTION | | | 471.003, FLORIDA STATUTES , MAY BE PERFORMED BY AIR | | | CONDITIONING OR MECHANICAL CONTRACTORS LICENSED IN | | | ACCORDANCE WITH CHAPTER 489, FLORIDA STATUTES , OR BY | | | STATE OF FLORIDA CERTIFIED COMMERCIAL BUILDING ENERGY | | | RATERS. | | | DESIGN PROFESSIONALS RESPONSIBLE UNDER FLORIDA LAW FOR | | | THE DESIGN OF LIGHTING, ELECTRICAL, MECHANICAL, AND | | | PLUMBING SYSTEMS AND THE BUILDING SHELL, SHALL CERTIFY | | | COMPLIANCE OF THOSE BUILDING SYSTEMS WITH THE CODE BY | | | SIGNING AND PROVIDING THEIR PROFESSIONAL REGISTRATION | | | NUMBER ON THE ENERGY CODE FORM PROVIDED AS PART OF THE | | | PLANS AND SPECIFICATIONS TO THE BUILDING DEPARTMENT. | | | EXCEPTION: TYPED NAMES AND REGISTRATION NUMBERS MAY BE | | | PROVIDED IN LIEU OF A SIGNATURE WHERE ALL RELEVANT | | | INFORMATION HAS BEEN INCLUDED ON SIGNED AND SEALED | | | PLANS. | | | | | | 3) AS NOTED IN LAST REVIEW 5-1-07 NOTE #5. SEE | | | MECHANICAL PLANS, TITLE BLOCK,(NELSON MARIN) IF NOT A | | | LICENSE ENGINEER MAY NOT DO COMMERCIAL MECHANICAL | | | PLANS, SEE F.S. 471.003. IF A LICENSE ENGINEER THEN HE | | | NEEDS TO PUT HIS INFORMATION IN THE TITLE BLOCK, SEE | | | FAC 61G15-23.002. LICENSE #CAC055529 BELONGS TO | | | JERONIMO MARIN (NOT NELSON MARIN). | | | | | | 4) AS NOTED IN LAST REVIEW 5-1-07 NOTE #6. THE | | | COMMERCIAL MECHANICAL PLANS NEED TO BE DONE BY AN | | | ENGINEER, OR A/C CONTRACTOR, MECHANICAL CONTRACTOR IF | | | APPLICABLE, SEE F.S. 471.003. (NOT NELSON MARIN). | | | | | | 5) AS NOTED IN LAST REVIEW 5-1-07 NOTE #2. PLEASE | | | PROVIDE OUTDOOR AIR CALCULATIONS, AND OUTDOOR AIR, SEE | | | 2004 FBC/M 403.1. (NEED TO SHOW THE CALCULATIONS ON THE | | | MECHANICAL PLAN NOT JUST SHOW A FRESH AIR VENT). | | | | | | 6)SEE ATTACHED NOTICE FS 553.80 (2) (B) REGARDING | | | FOUR TIMES THE FEE. | | | | | | 7) PLEASE BE ADVISED A COPY OF THE MECHANICAL PLANS AND | | | ENERGY CALCULATIONS ARE BEING RETAINED AND MAY BE SENT | | | TO THE DEPARTMENT OF BUSINESS AND PROFESSIONAL | | | REGULATIONS. | | | | | | 8) PLEASE SUBMIT COOLING LOAD CALCULATIONS, SEE 2004 | | | FBC 13-407.1.ABC.1. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL: [email protected]. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-05-01 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-05-01 |
Time |
14:22 |
Rev Time |
1.00 |
| Received By |
tgordon |
Date |
2007-05-01 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2007-05-01 14:29:37 | *** DENIED *** | | | 1) THE BATHROOM WILL REQUIRE AN EXHAUST FAN, SEE 2004 | | | FBC/M 403.3, PLEASE CORRECT. | | | | | | 2) PLEASE PROVIDE OUTDOOR AIR CALCULATIONS, AND OUTDOOR | | | AIR, SEE 2004 FBC/M 403.1. | | | | | | 3)ENERGY CALCULATIONS "PREPARED BY" NEED TO BE SIGNED | | | AND SEALED BY AN ARCHITECT OR ENGINEER, SEE 2004 FBC | | | 13-103.1.1.1. | | | | | | 4) ENERGY CALCULATIONS NEED A "MECHANICAL DESIGNER" WHO | | | IS A ENGINEER, OR AN ARCHITECT, AIR CONDITIONING | | | CONTRACTOR, OR MECHANICAL CONTRACTOR IF APPLICABLE, SEE | | | 2004 FBC 13-103.1.1.1 AND F.S. 471.003 (H). | | | | | | *** 2004 FBC 13-103.1.1.1 COMMERCIAL APPLICATIONS. | | | COMPLETION OF PROCEDURES DEMONSTRATING COMPLIANCE WITH | | | THIS CODE FOR COMMERCIAL BUILDINGS SHALL BE SIGNED AND | | | SEALED BY AN ARCHITECT OR ENGINEER LICENSED TO PRACTICE | | | IN THE STATE OF FLORIDA, WITH THE EXCEPTION OF | | | BUILDINGS EXCLUDED BY SECTION 481.229, FLORIDA STATUTES | | | , OR SECTION 471.003, FLORIDA STATUTES. CALCULATIONS | | | FOR BUILDINGS FALLING WITHIN THE EXCEPTION OF SECTION | | | 471.003, FLORIDA STATUTES , MAY BE PERFORMED BY AIR | | | CONDITIONING OR MECHANICAL CONTRACTORS LICENSED IN | | | ACCORDANCE WITH CHAPTER 489, FLORIDA STATUTES , OR BY | | | STATE OF FLORIDA CERTIFIED COMMERCIAL BUILDING ENERGY | | | RATERS. | | | DESIGN PROFESSIONALS RESPONSIBLE UNDER FLORIDA LAW FOR | | | THE DESIGN OF LIGHTING, ELECTRICAL, MECHANICAL, AND | | | PLUMBING SYSTEMS AND THE BUILDING SHELL, SHALL CERTIFY | | | COMPLIANCE OF THOSE BUILDING SYSTEMS WITH THE CODE BY | | | SIGNING AND PROVIDING THEIR PROFESSIONAL REGISTRATION | | | NUMBER ON THE ENERGY CODE FORM PROVIDED AS PART OF THE | | | PLANS AND SPECIFICATIONS TO THE BUILDING DEPARTMENT. | | | EXCEPTION: TYPED NAMES AND REGISTRATION NUMBERS MAY BE | | | PROVIDED IN LIEU OF A SIGNATURE WHERE ALL RELEVANT | | | INFORMATION HAS BEEN INCLUDED ON SIGNED AND SEALED | | | PLANS. | | | | | | 5) SEE MECHANICAL PLANS, TITLE BLOCK,(NELSON MARIN) | | | IF NOT A LICENSE ENGINEER MAY NOT DO COMMERCIAL | | | MECHANICAL PLANS, SEE F.S. 471.003. IF A LICENSE | | | ENGINEER THEN HE NEEDS TO PUT HIS INFORMATION IN THE | | | TITLE BLOCK, SEE FAC 61G15-23.002. | | | | | | 6) THE COMMERCIAL MECHANICAL PLANS NEED TO BE DONE BY | | | AN ENGINEER, OR A/C CONTRACTOR, MECHANICAL CONTRACTOR | | | IF APPLICABLE, SEE F.S. 471.003. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2008-04-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-04-28 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-04-28 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2008-04-28 15:52:42 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 BUILDING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | ******FROM PREVIOUS REVIEWS: | | | | | | | | | 1. OK | | | | | | 2. PER TABLE 403.1 A DRINKING FOUNTAIN AND A SERVICE | | | SINK ARE REQUIRED. PLEASE SHOW THE LOCATION OF EACH ON | | | THE FLOOR PLAN. | | | ****DRINKING FOUNTAIN NOTED, BUT NO SERVICE SINK | | | INDICATED. | | | ******NO RESPONSE, COMMENT NOT ADDRESSED. SERVICE SINK | | | NOT SHOWN. | | | | | | 3. SHT A-3 INDICATES NEW PARAPET WALLS HAVE BEEN ADDED. | | | SUBMIT A ROOF PLAN DETAIL SHOWING THE LOCATION OF ALL | | | PRIMARY & SECONDARY ROOF DRAINS. SUBMIT CALCULATIONS | | | FOR PRIMARY & SECONDARY ROOF DRAINS. SHOW THE SQUARE | | | FOOTAGE OF EACH AREA BEING DRAIN BY EACH ROOF DRAIN AS | | | WELL AS 1/2 AREA OF ALL VERTICAL WALLS, INCLUDING | | | PARAPETS ADDED TO THE ROOF AREA OF EACH DRAIN SHOWING | | | THE TOTAL AREA. SHOW THE ELEVATION OF THE ROOF & THE | | | ELEVATION OF THE PARAPET WALLS. SHOW THE NORTH AND THE | | | SOUTH BUILDING ELEVATIONS. SECTIONS 106.1.2, 1106 & | | | 1107 AS WELL AS TABLE 1106.3. | | | ****ROOF PLAN INDICATED ON SHT 5.1. THE LOCATION OF THE | | | SECONDARY ROOF DRAINS ARE NOT INDICATED. PLEASE SHOW | | | THE LOCATION OF ALL SECONDARY ROOF DRAINS. CALCULATIONS | | | INDICATE 6 RWL'S, BUT ROOF PLAN ONLY SHOWS 4. IF THERE | | | ARE ONLY 4 RD'S THEN 4" RD'S AND PIPING WILL BE | | | REQUIRED PER TABLE 1106.3. PLEASE CLARIFY. INDICATE THE | | | SLOPE OF THE ROOF TO THE ROOF DRAINS. THE EXISTING | | | CONCRETE PASS THROUGH ROOF APPEARS TO BE ABOVE THE TWO | | | STORY SECTION OF THE BUILDING. PLEASE INDICATE IF ANY | | | OF THIS ROOF DRAINS ON TO THE ROOF BELOW. ALSO INDICATE | | | THE HEIGHT & WIDTH DIMENSIONS OF THE VERTICAL WALL | | | ADJACENT TO THE LOWER ROOF ATTACHED TO THE PASS THROUGH | | | ROOF. 1/2 THE AREA OF THIS WALL SHALL BE ADDED TO THE | | | CALCULATIONS ALONG WITH THE PARAPET WALLS. | | | ******NO COMMENT RESPONSE. THE SQUARE FOOTAGE OF EACH | | | AREA IS NOT INDICATED. THE PARAPETS ARE INDICATED AS | | | 350.66 IN LENGHT WITH AN AVERAGE HEIGHT OF 2'0". 1/2 OF | | | THAT AREA WOULD BE 350.66SF NOT 293.80SF. NO RESPONSE | | | TO THE QUESTION CONCERNING THE EXISTING CONCRETE PASS | | | THROUGH ROOF, NOR IS THERE ANY RESPONSE TO THE HEIGHT | | | OF THE WALLL TO THE WEST SIDE OF THE NEW ROOF.-- | | | SHT 5.1 DETAIL FOR THE PARAPET WALL, PLEASE INDICATE | | | THE ELEVATION TO THE TOP OF THE PARAPET, AS WELL AS THE | | | ELEVATION OF THE ROOF AT THE PARAPET.--SUBMIT A | | | SECTION FROM THE EAST SIDE OF THE NEW ROOF THRU THE | | | PASS THRU ROOF SHOWING ALL ELVATIONS FOR THE ROOFS AND | | | PARAPETS.--SUBMIT A DETAIL FOR THE EMERGENC | | | OVERFLOW SCUPPERS SHOWING COMPLIANCE WITH SECTION | | | 1503.4.3. | | | | | | 4. SUBMIT A DETAIL FOR THE REQUIRED DRINKING FOUNTAIN | | | SHOWING COMPLIANCE WITH SECTION 11-4.15 WITH ALL | | | SUBSECTIONS AS WELL SECTION 11-4.1.3(10)(A) PROVISIONS | | | FOR THOSE WHO HAVE DIFFICULTY BENDING OR STOOPING. | | | ****DETAIL NOTED, BUT THE PROVISIONS FOR THOSE WHO HAVE | | | DIFFICULTY BENDING OR STOOPING HAS NOT BEEN ADDRESSED. | | | ******DETAIL NOTED, BUT THE PROVISIONS FOR THOSE WHO | | | HAVE DIFFICULTY BENDING OR STOOPING HAS NOT BEEN | | | ADDRESSED. | | | | | | 5. OK | | | 6. OK | | | 7. OK - (DELETED) | | | 8. OK | | | | | | **********NEW COMMENT********** | | | | | | 1B. OK | | | 2B. OK | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID | | | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY | | | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | ******NO RESPONSE, NOT ADDRESSED. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-09-19 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-09-19 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-09-19 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2007-09-19 17:36:55 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 BUILDING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | | | | ****FROM PREVIOUS REVIEW: | | | | | | | | | 1. OK | | | | | | 2. PER TABLE 403.1 A DRINKING FOUNTAIN AND A SERVICE | | | SINK ARE REQUIRED. PLEASE SHOW THE LOCATION OF EACH ON | | | THE FLOOR PLAN. | | | ****DRINKING FOUNTAIN NOTED, BUT NO SERVICE SINK | | | INDICATED. | | | | | | 3. SHT A-3 INDICATES NEW PARAPET WALLS HAVE BEEN ADDED. | | | SUBMIT A ROOF PLAN DETAIL SHOWING THE LOCATION OF ALL | | | PRIMARY & SECONDARY ROOF DRAINS. SUBMIT CALCULATIONS | | | FOR PRIMARY & SECONDARY ROOF DRAINS. SHOW THE SQUARE | | | FOOTAGE OF EACH AREA BEING DRAIN BY EACH ROOF DRAIN AS | | | WELL AS 1/2 AREA OF ALL VERTICAL WALLS, INCLUDING | | | PARAPETS ADDED TO THE ROOF AREA OF EACH DRAIN SHOWING | | | THE TOTAL AREA. SHOW THE ELEVATION OF THE ROOF & THE | | | ELEVATION OF THE PARAPET WALLS. SHOW THE NORTH AND THE | | | SOUTH BUILDING ELEVATIONS. SECTIONS 106.1.2, 1106 & | | | 1107 AS WELL AS TABLE 1106.3. | | | ****ROOF PLAN INDICATED ON SHT 5.1. THE LOCATION OF THE | | | SECONDARY ROOF DRAINS ARE NOT INDICATED. PLEASE SHOW | | | THE LOCATION OF ALL SECONDARY ROOF DRAINS. CALCULATIONS | | | INDICATE 6 RWL'S, BUT ROOF PLAN ONLY SHOWS 4. IF THERE | | | ARE ONLY 4 RD'S THEN 4" RD'S AND PIPING WILL BE | | | REQUIRED PER TABLE 1106.3. PLEASE CLARIFY. INDICATE THE | | | SLOPE OF THE ROOF TO THE ROOF DRAINS. THE EXISTING | | | CONCRETE PASS THROUGH ROOF APPEARS TO BE ABOVE THE TWO | | | STORY SECTION OF THE BUILDING. PLEASE INDICATE IF ANY | | | OF THIS ROOF DRAINS ON TO THE ROOF BELOW. ALSO INDICATE | | | THE HEIGHT & WIDTH DIMENSIONS OF THE VERTICAL WALL | | | ADJACENT TO THE LOWER ROOF ATTACHED TO THE PASS THROUGH | | | ROOF. 1/2 THE AREA OF THIS WALL SHALL BE ADDED TO THE | | | CALCULATIONS ALONG WITH THE PARAPET WALLS. | | | | | | 4. SUBMIT A DETAIL FOR THE REQUIRED DRINKING FOUNTAIN | | | SHOWING COMPLIANCE WITH SECTION 11-4.15 WITH ALL | | | SUBSECTIONS AS WELL SECTION 11-4.1.3(10)(A) PROVISIONS | | | FOR THOSE WHO HAVE DIFFICULTY BENDING OR STOOPING. | | | ****DETAIL NOTED, BUT THE PROVISIONS FOR THOSE WHO HAVE | | | DIFFICULTY BENDING OR STOOPING HAS NOT BEEN ADDRESSED. | | | | | | 5. SHT A-3 SHOW COMPLIANCE WITH THE FOLLOW: | | | ___FOR THE W/C: | | | A. 11-4.16.5 FLUSH CONTROLS | | | ****DETAIL SHOWS THE FLUSH CONTROLS ON THE WRONG SIDE | | | OF THE TANK. | | | ___FOR THE LAV: | | | A. OK | | | | | | 6. OK | | | 7. OK - (DELETED) | | | 8. OK | | | | | | **********NEW COMMENT********** | | | | | | 1B. SHT 6.1 THE SANITARY PLUMBING ISOMETRIC RISER | | | DIAGRAM DOES NOT MEET CODE REQUIREMENTS FOR SECTION | | | 901.2.1. A VENT IS REQUIRED FOR THE DRINKING FOUNTAIN. | | | ALSO HORIZONTAL DRY VENTS ARE NOT APPROVED PER SECTIONS | | | 905.3 & 905.4. THE VENTS BETWEEN THE LAVS ARE NOT | | | REQUIRED AND ARE HORIZONTAL DRY VENTS. DELETE FROM | | | FLOOR PLAN AND RISER DIAGRAM. VENT AT EACH LAV WILL BE | | | SUFFICIENT. | | | | | | 2B. FLORIDA ENERGY CALCULATIONS INDICATE NO WATER | | | HEATER, BUT THE FLOOR PLAN AND THE RISER DIAGRAM SHOW A | | | WATER HEATER. PLEASE CORRELATE THE INFORMATION ON THE | | | ENERGY CALCULATIONS WITH THE FLOOR PLAN. SECTION | | | 13-103. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID | | | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY | | | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-06-08 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-06-08 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-06-08 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2007-06-08 16:12:32 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 BUILDING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | | | | 1. PER TABLES 1004.1.2 & 403.1 SEPARATE FACILITIES ARE | | | REQUIRED FOR THE MEN & WOMEN AND AS STATED IN SECTION | | | 403.2 UNLESS AN EXCEPTION TO THIS SECTION IS INDICATED | | | ON THE PLANS AND APPROVED. | | | | | | 2. PER TABLE 403.1 A DRINKING FOUNTAIN AND A SERVICE | | | SINK ARE REQUIRED. PLEASE SHOW THE LOCATION OF EACH ON | | | THE FLOOR PLAN. | | | | | | 3. SHT A-3 INDICATES NEW PARAPET WALLS HAVE BEEN ADDED. | | | SUBMIT A ROOF PLAN DETAIL SHOWING THE LOCATION OF ALL | | | PRIMARY & SECONDARY ROOF DRAINS. SUBMIT CALCULATIONS | | | FOR PRIMARY & SECONDARY ROOF DRAINS. SHOW THE SQUARE | | | FOOTAGE OF EACH AREA BEING DRAIN BY EACH ROOF DRAIN AS | | | WELL AS 1/2 AREA OF ALL VERTICAL WALLS, INCLUDING | | | PARAPETS ADDED TO THE ROOF AREA OF EACH DRAIN SHOWING | | | THE TOTAL AREA. SHOW THE ELEVATION OF THE ROOF & THE | | | ELEVATION OF THE PARAPET WALLS. SHOW THE NORTH AND THE | | | SOUTH BUILDING ELEVATIONS. SECTIONS 106.1.2, 1106 & | | | 1107 AS WELL AS TABLE 1106.3. | | | | | | 4. SUBMIT A DETAIL FOR THE REQUIRED DRINKING FOUNTAIN | | | SHOWING COMPLIANCE WITH SECTION 11-4.15 WITH ALL | | | SUBSECTIONS AS WELL SECTION 11-4.1.3(10)(A) PROVISIONS | | | FOR THOSE WHO HAVE DIFFICULTY BENDING OR STOOPING. | | | | | | 5. SHT A-3 SHOW COMPLIANCE WITH THE FOLLOW: | | | ___FOR THE W/C: | | | A. 11-4.16.5 FLUSH CONTROLS | | | ___FOR THE LAV: | | | A. 11-4.19.3 CLEAR FLOOR SPACE | | | | | | 6. SUBMIT A WATER RISER DIAGRAM SHOWING ALL PIPE SIZES, | | | VAVES ETC. SECTION 106.3.5.1.3(3)(10)(13). | | | | | | 7. PER SECTION 11-4.35.4 A BENCH IS REQUIRED IN THE | | | CHANGING ROOM. | | | | | | 8. AN RPZV BACKFLOW IS REQUIRED ON THE WATER SERVICE TO | | | THE BUILDING. SECTION 608.13.2. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. REMOVE ALL VOID | | | SHEETS FROM ALL PLANS AND PLACE ONE SET OF THEM LOOSELY | | | ON TOP OF THE COLLATED PLANS TO BE REVIEWED. THANK YOU | | | FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2008-04-25 |
|
|
Cont ID |
|
| Sent By |
kdfreema |
Date |
2008-04-25 |
Time |
10:10 |
Rev Time |
0.00 |
| Received By |
kdfreema |
Date |
2008-04-25 |
Time |
10:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-09-10 |
|
|
Cont ID |
|
| Sent By |
bpowell |
Date |
2007-09-10 |
Time |
18:07 |
Rev Time |
0.00 |
| Received By |
bpowell |
Date |
2007-09-10 |
Time |
17:53 |
Sent To |
|
|
| Notes |
| 2007-09-10 18:05:08 | 1. AN INFORMAL SITE PLAN REVIEW WILL BE REQUIRED PER | | | SEC. 94-35 OF THE CITY'S ZONING AND LAND DEVELOPMENT | | | REGULATIONS. | | | | | | THE FOLLOWING COMMENTS ARE GENERAL COMMENTS PROVIDED | | | FOR GUIDANCE, THE PLANNING DEPARTMNET RESERVES THE | | | RIGHT TO MAKE ADDITONAL COMMENTS UPON SUBMITTAL OF A | | | SITE PLAN. | | | | | | A. THE LANDSCAPING SHALL BE BROUGHT INTO COMPLIANCE PER | | | SEC. 94-443 OF THE CITY'S ZONING AND LAND DEVELOPMENT | | | REGULATIONS. | | | | | | B.ALL PARKING SHALL BE DOUBLE STRIPPED, AT LEAST ONE | | | (1) DISABLED SPACE SHALL BE PROVIDED FOR EACH 25 | | | PARKING SPACES OR FRACTION THEREOF. | | | | | | C.IT IS RECOMMENDED THAT THE APPLICANT SCHEDULE AN | | | APPOINTMENT WITH MYSELF OR ANOTHER PLANNER BEFORE | | | SUBMITTING FOR THE INFORMAL SITE PLAN REVIEW. | | | | | | FOR QUESTIONS OR COMMENTS CONTACT BOBBY POWELL JR., | | | PLANNER, CITYOFWPB.ORG, (561) 822-1435 |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-04-13 |
|
|
Cont ID |
|
| Sent By |
bpowell |
Date |
2007-04-13 |
Time |
11:55 |
Rev Time |
0.00 |
| Received By |
bpowell |
Date |
2007-04-13 |
Time |
11:35 |
Sent To |
|
|
| Notes |
| 2007-04-13 11:44:43 | 1. AN INFORMAL SITE PLAN REVIEW WILL BE REQUIRED PER | | | SEC.94-35 OF THE CITY'S ZONING AND LAND DEVELOPMENT | | | REGULATIONS. | | | | | | THE FOLLOWING COMMENTS ARE GENERAL COMMENTS PROVIDED | | | FOR GUIDANCE, THE PLANNING DEPARTMENT RESERVES THE | | | RIGHT TO MAKE ADDITIONAL COMMENTS UPON SUBMITTAL OF A | | | SITE PLAN. | | | | | | A. ADDITIONAL PARKING WILL BE REQUIRED TO REPLACE THE | | | PARKING THAT WILL BE TAKEN AWAY, AND FOR THE USE OF THE | | | NEW BUILDING PER SEC. 94-486 OF THE CITY'S ZONING AND | | | LAND DEVELOPMENT REGULATIONS. | | | | | | B. THE LANDSCAPING SHALL BE BROUGHT INTO COMPLIANCE PER | | | SEC. 94-443 OS THE CITY'S ZONING AND LAND DEVELOPMENT | | | REGULATIONS. | | | | | | BOBBY POWELL, PLANNER, | | | [email protected] | | | (561) 822-1435 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |