Plan Review Details - Permit 07040060
Plan Review Stops For Permit 07040060
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-07-26 Cont ID  
Sent By shill Date 2007-07-26 Time 18:34 Rev Time 0.00
Received By shill Date 2007-07-26 Time 18:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-06-12 Cont ID  
Sent By shill Date 2007-06-12 Time 16:26 Rev Time 0.00
Received By shill Date 2007-06-12 Time 16:26 Sent To  
Notes
2007-06-12 16:29:08****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
  
 FROM PREVIOUS LIST:
  
 1.)SEE BOTH PRODUCT APPROVALS, ANCHOR SCHEDULES (I
 HAVE PLACED A POST IT NOTE ON THIS SHEET).THE 12"
 SPACING YOU HAVE SPECIFIED ON THE INSTALLATION SCHEDULE
 DOES NOT APPEAR TO BE COMPLIANT FOR ANY OF THE
 DIFFERENT ANCHOR TYPES."MAXISET" WAS SPECIFIED ON THE
 SCHEDULE, BUT NONE OF THE ANCHORS ARE CALLED BY THAT
 NAME.PLEASE REVISE TO BE CONSISTENT WITH THE PRODUCT
 APPROVAL.
  
 2ND REVIEW - NOT ADDRESSED.THE SCHEDULE STILL STATES
 "MAXISET", OTHER ANCHORS CIRCLED ON THE PRODUCT
 APPROVALS.12" ANCHOR SPACING IS NOT COMPLIANT FOR THE
 BAHAMA SHUTTERS.REVISE ANCHOR SPACING AND ANCHOR, OR
 PROVIDE ENGINEERING FOR THE ANCHOR YOU WISH TO USE AS
 AN ALTERNATE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-05-03 Cont ID  
Sent By shill Date 2007-05-03 Time 16:03 Rev Time 0.00
Received By shill Date 2007-05-03 Time 16:03 Sent To  
Notes
2007-05-03 16:06:31****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 1.)SEE BOTH PRODUCT APPROVALS, ANCHOR SCHEDULES (I
 HAVE PLACED A POST IT NOTE ON THIS SHEET).THE 12"
 SPACING YOU HAVE SPECIFIED ON THE INSTALLATION SCHEDULE
 DOES NOT APPEAR TO BE COMPLIANT FOR ANY OF THE
 DIFFERENT ANCHOR TYPES."MAXISET" WAS SPECIFIED ON THE
 SCHEDULE, BUT NONE OF THE ANCHORS ARE CALLED BY THAT
 NAME.PLEASE REVISE TO BE CONSISTENT WITH THE PRODUCT
 APPROVAL.
  
 2.)SOME DETAILS WERE HIGHLIGHTED WHICH ARE NOT
 CORRECT.FOR INSTANCE, INCORRECT MINIMUM GLASS
 SEPARATION WAS HIGHLIGHTED, BUT IS CORRECT ON THE
 PRODUCT APPROVAL.DETAILS SPECIFIC TO THE JOB SHOULD
 BE CIRCLED IN INK IF IT IS HELPFUL FOR PLAN REVIEW AND
 INSPECTIONS AND SHOULD BE CORRECT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-04-07 Cont ID  
Sent By shill Date 2007-04-07 Time 13:45 Rev Time 0.00
Received By shill Date 2007-04-07 Time 13:45 Sent To  
Notes
2007-04-07 13:45:48****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
 ____1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH
 THE CLERK OF COURTS BEFORE A PERMIT CAN BE ISSUED,
 FS713.13.
  
 ____2.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN
 PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE
 DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY A
 DESIGN PROFESSIONAL. DOCUMENTS PREPARED BY AN ENGINEER
 AND SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED
 ORIGINALS FAC61G15-23.002.
  
 ____3.PROVIDE A COPY OF THE CONDO ASSOCIATION
 APPROVAL.
  
 _XX_4.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT.
  
 ____5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.
  
 ____6.ON THE PRODUCT APPROVAL, MARK WHICH DETAILS
 APPLY TO THIS JOB.PLEASE USE INK RATHER THAN A
 HIGHLIGHTER.
  
 ____7.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC
 R310.
  
 ____8.PROVIDE A FLOOR PLAN SHOWING WHERE THE
 SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH
 CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 4
 ABOVE.
  
 ____9.REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2),
 FBC R301.2.1.4.NOTE THAT THE DEFINITION FOR EXPOSURE
 C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC
 R301.2.1.4.
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-07-13 Cont ID  
Sent By adarroug Date 2007-07-13 Time 11:05 Rev Time 0.00
Received By adarroug Date 2007-07-13 Time 11:05 Sent To B
Notes
2007-07-13 11:06:07TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-06-06 Cont ID  
Sent By adarroug Date 2007-06-06 Time 10:53 Rev Time 0.00
Received By adarroug Date 2007-06-06 Time 10:53 Sent To B
Notes
2007-06-06 10:54:17TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-05-02 Cont ID  
Sent By adarroug Date 2007-05-02 Time 11:05 Rev Time 0.00
Received By adarroug Date 2007-05-02 Time 11:05 Sent To B
Notes
2007-05-02 11:05:50TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-05-03 Cont ID  
Sent By adarroug Date 2007-05-03 Time 10:53 Rev Time 0.00
Received By adarroug Date 2007-04-03 Time 17:30 Sent To  
Notes
2007-04-03 17:31:14SENT TO MISC BOX # 1