| Plan Review Stops For Permit 07040033 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-07-18 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2007-07-18 |
Time |
|
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-07-18 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-07-18 |
Time |
07:20 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-07-18 |
Time |
07:20 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-07-11 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-07-11 |
Time |
06:27 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-07-11 |
Time |
05:55 |
Sent To |
PC |
|
| Notes |
| 2007-07-11 06:27:51 | BUILDING PLAN REVIEW | | | PERMIT:07040033 | | | ADD: 1830 EMBASSY DRIVE | | | CONT: STRATICON CONST SERVICES | | | TEL: (269)629-5915 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW: 2ND | | | ACTION: DENIED | | | | | | 1)61G1-16.004 TITLE BLOCK. | | | A TITLE BLOCK MUST APPEAR ON ALL ARCHITECTURAL OR | | | INTERIOR DESIGN DRAWINGS AND SPECIFICATION | | | IDENTIFICATION SHEETS. THE TITLE BLOCK MUST, AT A | | | MINIMUM, CONTAIN THE FOLLOWING INFORMATION: | | | (1) FIRM NAME, ADDRESS, AND TELEPHONE NUMBER. | | | (2) FIRM LICENSE NUMBER. | | | (3) NAME OR IDENTIFICATION OF PROJECT. | | | (4) DATE PREPARED. | | | (5) A SPACE FOR THE SIGNATURE AND DATED SEAL. | | | (6) A SPACE FOR THE PRINTED NAME OF THE PERSON SEALING | | | THE DOCUMENT. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-04-12 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-04-12 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-04-12 |
Time |
15:53 |
Sent To |
PC |
|
| Notes |
| 2007-04-12 15:34:42 | BUILDING PLAN REVIEW | | | PERMIT: 07040033 | | | ADD:1830 EMBASSY DR. | | | CONT: STRATICON CONSTRUCTION SERVICES | | | TEL: (954)464-9130 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 1ST | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2) 1008.1.1THE MINIMUM WIDTH OF EACH DOOR OPENING | | | SHALL BE SUFFICIENT FOR THE OCCUPANT LOAD THEREOF AND | | | SHALL PROVIDE A CLEAR WIDTH OF NOT LESS THAN 32 INCHES. | | | THE HEIGHT SHALL NOT BE LESS THAN 6' 8". | | | | | | 3)106.3.3* PRODUCT APPROVALS- 2004 | | | THOSE PRODUCTS THAT ARE RGULATED BY DCA | | | RULE 9B-72 SHALL BE REVIEWED AND | | | APPROVED IN WRITTING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. SUBMIT TWO COPIES OF PRODUCT | | | APPROVAL FOR THE NEW DOOR. | | | | | | 4)ALL PLANS SUBMITTED AFTER OCTOBER, 1, | | | 2004 SHALL BE DESIGNED TO THE 2004 | | | FLORIDA BUILDING CODE. | | | | | | 5)106.1.3* THE BUILDING OFFICIAL | | | MAY SET STANDARDS THROUGH DEPARTMENTAL | | | POLICY STANDARDS FOR PLANS AND SPRCIFICA | | | TIONS. "NO WHITE OUT" AND "NO HAND WRITING"ON THE | | | DRAWINGS. THE ONLY PERSON WHO CAN MAKE CHANGES TO THE | | | DRAWINGS IS THE DESIGNER OF RECORD AND THE CHANGES WILL | | | HAVE TO BE SIGNED AND DATED BY THAT PERSON. | | | | | | 6)61G1-16.004 TITLE BLOCK. | | | A TITLE BLOCK MUST APPEAR ON ALL ARCHITECTURAL OR | | | INTERIOR DESIGN DRAWINGS AND SPECIFICATION | | | IDENTIFICATION SHEETS. THE TITLE BLOCK MUST, AT A | | | MINIMUM, CONTAIN THE FOLLOWING INFORMATION: | | | (1) FIRM NAME, ADDRESS, AND TELEPHONE NUMBER. | | | (2) FIRM LICENSE NUMBER. | | | (3) NAME OR IDENTIFICATION OF PROJECT. | | | (4) DATE PREPARED. | | | (5) A SPACE FOR THE SIGNATURE AND DATED SEAL. | | | (6) A SPACE FOR THE PRINTED NAME OF THE PERSON SEALING | | | THE DOCUMENT. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-07-16 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-07-16 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-07-16 |
Time |
14:06 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-07-02 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-07-02 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-07-02 |
Time |
12:27 |
Sent To |
M |
|
| Notes |
| 2007-07-02 12:32:23 | | | | | | | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW | | | | | | THE ENGINEER WHOSE NAME APPEARS ON THE TITLE BLOCK MUST | | | SIGN, DATE AND SEAL THE DOCUMENT. 61G15-23.002 FAC. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] | | | FAX/:561/805-6676 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-04-12 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-04-12 |
Time |
10:09 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-04-12 |
Time |
08:00 |
Sent To |
M |
|
| Notes |
| 2007-04-12 10:09:39 | | | | | | | NONCOMPLIANT | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1} THE ENGINEER OF RECORD SHALL INDICATE THE | | | CERTIFICATE OF AUTHORIZATIONNUMBER ALONG WITH OTHER | | | INFORMATION REQUIRED BY 61G15-23.002FLORIDA | | | ADMINISTRATIVE CODE. | | | | | | 2} THERE IS A NOTE ON THE PLAN THAT THE EXISTING FIRE | | | PUMP DISCONNECT IS TO BE DEMOLISHED. PLEASE EXPOUND ON | | | THIS COMMENT IF IT IS WITHIN THE SCOPE OF THIS PERMIT. | | | IF IT IS NOT, PLEASE REMOVE, AND SUBMIT PLANS WITH | | | INFORMATION PERTINENT TO THE SCOPE. | | | | | | 3} PLEASE NOTE THAT HAND DRAWN CHANGES TO THE PLAN ARE | | | NOT ACCEPTABLE AS THEY CANNOT BE VERIFIED AS BEING MADE | | | BY THE DESIGNER OF RECORD AS REQUIRED BY FS 471 OR 481, | | | AS APPLICABLE. | | | | | | 4}INDICATE PANEL DESIGNATION AND CIRCUIT NUMBERS FOR | | | DEVICES OR EQUUIPMENT BEING INSTALLED UNDER THIS | | | PERMIT. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-06-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-25 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-25 |
Time |
11:05 |
Sent To |
E |
|
| Notes |
| 2007-06-25 11:05:54 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2007-04-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-04-02 |
Time |
17:49 |
Sent To |
E |
|
| Notes |
| 2007-04-02 17:49:46 | TO ELEC BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-07-16 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-16 |
Time |
15:51 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-07-16 |
Time |
15:51 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-07-03 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-07-03 |
Time |
09:26 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-07-03 |
Time |
09:26 |
Sent To |
B |
|
| Notes |
| 2007-07-03 09:31:45 | *** DENIED *** | | | 1) THE ENGINEER'S SEAL IS MISSING FROM THE PLANS. | | | PLEASE CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-04-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-04-12 |
Time |
11:59 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-04-12 |
Time |
11:58 |
Sent To |
B |
|
| Notes |
| 2007-04-12 12:15:24 | *** DENIED *** | | | 1) LASTAYO PADILLA AND ASSOCIATES, INC. MUST SHOW THEIR | | | CORRECT COMPANY NAME AND LICENSE NUMBER IN THE TITLE | | | BLOCK, SEE ATTACHED LICENSE INFORMATION, PLEASE | | | CORRECT,PER FAC 61G1-16.004. | | | | | | 2) THE JOB ADDRESS NEEDS TO BE IN THE TITLE BLOCK, SEE | | | 2004 FBC CITY OF WPB AMEND. 106.1.3, PLEASE CORRECT. | | | | | | 3) INFORMATION MISSING FROM TITLE BLOCK FOR ENGINEER. | | | SEE FAC 61G15-23.002 (2)A TITLE BLOCK ON EACH SHEET | | | CONTAINING THE PRINTED NAME, ADDRESS, AND LICENSE | | | NUMBER OF THE ENGINEER OR IF APPLICABLE, THE NAME AND | | | LICENSE NUMBER OF THE ENGINEER, AND THE NAME, ADDRESS | | | AND CERTIFICATE OF AUTHORIZATION NUMBER OF THE | | | ENGINEERING BUSINESS WILL SATISFY THIS REQUIREMENT. | | | | | | 4) SEE PLANE (GENERAL H>V>A>C> NOTES) #1 STATES 2001 | | | FBC, THE 2004 FBC IS PRESENTLY BEING USED, PLEASE | | | CORRECT. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|