Plan Review Details - Permit 07040008
| Plan Review Stops For Permit 07040008 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-04-16 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-04-16 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-04-16 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2007-04-16 11:05:57 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | 1.)A STRUCTURAL REPAIR DETAIL FOR THE ROOF IS | | | REQUIRED PER BUILDING INSPECTOR. | | | | | | 2.)A BUILDING PERMIT WILL BE REQUIRED IN ADDITION TO | | | THE ROOF PERMIT.YOU MAY ADD THIS TO THE SCOPE OF WORK | | | AND SIGN ON THE APPROPRIATE LINE ON THE PERMIT | | | APPLICATION.A NEW PERMIT NUMBER WILL BE GENERATED. | | | PLEASE DO THIS WHEN RESUBMITTING THROUGH THE FRONT | | | COUNTER. | | | | | | 3.)THE ASSEMBLIES YOU HAVE SELECTED REFER TO GENERAL | | | LIMITATION #9.ENHANCED FASTENING CANNOT BE USED, AND | | | THE SYSTEM IS LIMITED TO -45PSF.A DESIGN PRESSURE OF | | | -89 IS REQUIRED.A SYSTEM WITH GENERAL LIMITATION #7 | | | MUST BE SELECTED. | | | | | | 4.)SELECT ONLY ONE ASSEMBLY.IF YOU CHANGE THE | | | ASSEMBLY, YOU CAN APPLY FOR A REVISION. | | | | | | 5.)SPECIFY ENHANCED FASTENING FOR ZONES 2 AND 3. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-04-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-04-02 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-04-02 |
Time |
12:16 |
Sent To |
|
|
| Notes |
| 2007-04-02 12:19:05 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 | | | EXISTING BUILDING CODE | | | FBC*CITY OF WEST PALM BEACH | | | AMENDMENTS TO THE FBC2004 | | | | | | ROOFING PERMIT; ONLY CHECKED ITEMS APPLY | | | | | | ____1.)A NOTICE OF COMMENCEMENT MUST BE FILED WITH | | | THE CLERK OF COURTS PRIOR TO PERMIT PICKUP, FS713.13. | | | | | | ____2.)CONTRACTOR IS TO PROVIDE THE FOLLOWING | | | INFORMATION ON THE APPLICATION, SEE ATTACHED POLICY: | | | | | | MEAN ROOF HEIGHT | | | ROOF PITCH | | | ROOF DECK TYPE | | | AREA OF EACH ROOF TYPE | | | | | | _XX_3.)THE PRODUCT APPROVAL IS FOR REROOF, SHOULD | | | BE FOR RECOVER. | | | | | | _XX_4.)INDICATE WHICH FASTENER OPTION YOU ARE USING | | | IN THE ASSEMBLY YOU HAVE CHOSEN. | | | | | | _XX_5.)FOR THE FLAT DECK, SPECIFY THE ENHANCED | | | FASTENING FOR CORNER AND PERIMETER ZONES. | | | | | | ____ 6.)ON THE TILE PRODUCT APPROVAL, INDICATE WHICH | | | METHOD OF ATTACHMENT YOU ARE USING. | | | | | | ____ 7.)SEE PRODUCT LIMITATION #7.CALCULATIONS | | | PREPARED BY AN ARCHITECT, ENGINEER, OR REGISTERED ROOF | | | CONSULTANT REQUIRED FOR ENHANCED FASTENING. | | | | | | |
|
|
|