Plan Review Details - Permit 07031069
Plan Review Stops For Permit 07031069
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-04-19 Cont ID  
Sent By shill Date 2007-04-19 Time 17:18 Rev Time 0.00
Received By shill Date 2007-04-19 Time 17:18 Sent To  
Notes
2007-04-19 17:22:31****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC*
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
 FACFLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)SHOW ALL ROOM DIMENSIONS, FBC R 304.
  
 2.)DECLARE LEVEL OF ALTERATION, FBC EB CHAPTER 3.
  
 3.)SHOW COMPLIANCE WITH FBC R 317, DWELLING UNIT
 SEPARATION.
  
 4.)SHOW ALL PENETRATIONS AND PROVIDE A DETAIL IN
 COMPLIANCE WITH FBC R 317.3.
  
 5.)THE PERMIT APPLICATION DESCRIBES WORK NOT SHOWN ON
 THE PLAN.REVISE THE PLAN TO SHOW ALL WORK TO BE
 DONE.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-04-11 Cont ID  
Sent By dpalmer Date 2007-04-11 Time 10:38 Rev Time 0.00
Received By dpalmer Date 2007-04-11 Time 10:38 Sent To M
Notes
2007-04-11 10:39:33** UNSAT **
  
 1) NOTE: PLEASE SUBMIT PLANS WHICH INDICATE THE LEGAL
 CONVERSION BACK TO A SINGLE FAMILY RESIDENCE.
 PLEASE SEE THAT THIS BUILDING SEEMS TO HAVE BEEN
 CONVERTED TO A DUPLEX WITH OUT ELECTRICAL CODE
 COMPLIANCE.
 PLEASE SEE ZONING COMMENTS, AS THIS BUILDING MAY NOT BE
 CONVERTED TO A DUPLEX, PLEASE INDICATE
 AS BEING CONVERTED BACK TO A SFR.
  
 2) NOTE: PLEASE SUBMIT ELECTRICAL PLANS WHICH INDICATE
 EXISTING AND OR NEW ELECTRICAL WHICH MEETS CODE
 COMPLIANCE. AS WORK SEEMS TO HAVE BEEN DONE W/OUT THE
 CORRECT PERMITTING IT IS UNCLEAR WHAT IS CODE COMPLIANT
 THAT IS EXISTING.
 PLEASE SEE 210.8A FOR ALL LOCATIONS WHICH REQUIRE GFI
 PROTECTION.
 PLEASE SEE 210.52C FOR KITCHEN COUNTER RECEPTACLES
 WHICH IS ONLY TO BE FOR ONE KITCHEN.
 PLEASE SEE 210.52B1,210.11C, 220.53 FOR SMALL APPLIANCE
 CIRCUITS, BATH CIRCUITS, LAUNDRY ETC.
 PLEASE SEE ALL OF 220 FOR MINIMUM CIRCUITS REQUIRED
 ALONG WITH 210.52.
 PLEASE SHOW COMPLIANCE FOR ALL REQUIRED EGRESS LIGHTING
 INSIDE AND OUTSIDE THE DWELLING PER 210.70 AND LS 101
 7.8.
 PLEASE INDICATE NEW OR EXISTING SMOKE ALARMS PER
 NFPA-72 11.5.1.1, 11.8.3. (FBC R313)
 PLEASE SUBMIT A PANEL SCHEDULE SHOWING NEW OR EXISTING
 CIRCUITS MEETING CODE COMPLIANCE ALONG WITH CONDUCTOR
 SIZES. 408.4, 310.16, 240.4
 PLEASE SHOW THE SERVICE/PANEL LOCATION. INDICATE MAIN
 DISCONNECT, NEW OR EXISTING. 230.70, 230.71 ETC.
 PLEASE SEE NEC 2005 FOR MANY OF THE SECTIONS NOTED
 ABOVE.
 PLEASE ALSO SEE THE 2004 FBC W/ 2006 REVISIONS.
  
 * ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-04-19 Cont ID  
Sent By shill Date 2007-04-19 Time 17:22 Rev Time 0.00
Received By shill Date 2007-03-30 Time 17:26 Sent To  
Notes
2007-03-30 17:26:18TO ZONING

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-04-11 Cont ID  
Sent By tgordon Date 2007-04-11 Time 12:21 Rev Time 0.25
Received By tgordon Date 2007-04-11 Time 12:21 Sent To P
Notes
2007-04-11 12:26:24*** DENIED ***
 1) SEE ZONING REVIEW NOTES, PLEASE COMPLY.
  
 2) NO MECHANICAL PLANS WERE SUBMITTED FOR REVIEW.
 PLEASE SUBMIT MECHANICAL PLANS FOR REVIEW TO SHOW
 RETURN TO SINGLE FAMILY RESIDENCE.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-04-16 Cont ID  
Sent By mperson Date 2007-04-16 Time 14:56 Rev Time 0.33
Received By mperson Date 2007-04-16 Time 14:56 Sent To B
Notes
2007-04-16 15:11:15DENIED
 REFERENCE:
 ** FBC-2004 PLUMBING.
 ** FBC-2004 CHAPTER 1, THE CITY OF
 WEST PALM BEACH AMENDMENTS.
 ** FLORIDA ADMINISTRATIVE CODE.
 ** FLORIDA STATUTES.
  
 THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR
 PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE:
  
 1. SEE ZONING PLAN REVIEW COMMENTS AND PLEASE COMPLY.
  
 2. NO PLUMBING PLANS WERE SUBMITTED FOR REVIEW. PLEASE
 SUBMIT PLUMBING PLANS FOR REVIEW TO INDICATE THAT THE
 RESIDENCE HAS RETURNED TO A SINGLE FAMILY HOME. MORE
 INFORMATION IS REQUIRED. PLEASE INDICATE THE TYPE OF
 PLUMBING LEAKS BEING REPAIRED AS NOTED IN "NEW WORK"
  
 A} IF PLUMBING LAYOUT IS THE SAME
 WITH NO CHANGES, PLEASE INDICATE THIS ON
 THE DRAWING.
 B} IF PLUMBING LAYOUT IS THE
 SAME AND THE PLUMBING FIXTURES ARE TO BE
 CHANGED, PLEASE INDCATE ON THE DRAWING.
 "EXACT FIXTURE CHANGE OUT ONLY."
 C} IF THE NEW PROPOSED PLUMBING LAYOUT IS DIFFERENT
 FROM THE EXISTING PLEASE FOLLOW WHAT IS REQUIRED IN
 COMMENT #3
  
 3. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.4
 RESIDENTIAL (ONE AND TWO-FAMILY) PLEASE SUBMIT A
 PLUMBING SANITARY ISOMETRIC RISER DIAGRAM INDICATING
 ALL WASTE, VENTS, TRAPS AND SIZES WITH CLEANOUT
 LOCATIONS.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop Z ZONING
Rev No 1 Status F Date 2007-04-09 Cont ID  
Sent By adavila Date 2007-04-09 Time 19:51 Rev Time 0.00
Received By adavila Date 2007-04-09 Time 18:42 Sent To E
Notes
2007-04-09 19:51:52PLANNING AND ZONING DEPARTMENT
  
 ***FAILED***
  
 1. MAIN HOUSE MAY NOT BE CONVERTED INTO A DUPLEX AS IT
 DOES NOT MEET MINIMUM LOT SQUARE FOOTAGE REQUIRED.
  
 2. LOT AREA IS 5,010.5 SQUARE FEET.PER SECTION
 94-77(A)(1) OF THE ZONING AND LAND DEVELOPMENT
 REGULATIONS, MINIMUM LOT AREA REQUIRED FOR ONE OR TWO
 DWELLING UNITS IS 6,000 SQUARE FEET.
  
 COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.