| Plan Review Stops For Permit 07031054 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-06-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-06-07 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-06-07 |
Time |
13:50 |
Sent To |
PC |
|
| Notes |
| 2007-06-07 13:55:06 | BUILDING REVIEW APPROVED WITH PROVISO: | | | 1- ARCHITECT TO PROVIDE STRUCTURAL BUCK DETAIL FOR | | | SWING DOOR.DETAIL SHOWN ON PLANS IS FOR SLIDING GLASS | | | DOORS. ON THE OTHER HAND ARCHITECT TO SEE SWING DOOR | | | PRODUCT APPROVAL FOR REQUIRED STRUCTURAL BUCK SIZE. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-04-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-04-27 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-04-27 |
Time |
07:37 |
Sent To |
PC |
|
| Notes |
| 2007-04-27 11:10:51 | BUILDING REVIEW CHECKLIST: | | | | | | 1- ARCHITECT TO PROVIDE FIRM'S NUMBER IN THE TITLE | | | BLOCK ASREQUIRED BY SEC. 61G1-16.004 FLORIDA | | | ADMINISTRATIVE CODE. | | | | | | 2- ROOM CALLED STORAGE IS A BEDROOM.BEDROOM WINDOW | | | DOESN'T COMPLY WITH SECTION R310 OF 2004 FLORIDA | | | RESIDENTIAL CODE. REVISE AS REQUIRED. | | | | | | 3- AFTER PLANS ARE REVISED BRING THEM TO PALM BEACH | | | COUNTY (2300 N. JOG RD (561)233-5115)TO VERIFY IF | | | IMPACT FEES ARE DUE.BRING BACK STAMPED PLANS AND COPY | | | OF PAID RECEIPT IF FEES ARE DUE. | | | | | | 4- SEE PRODUCT APPROVAL FOR DOOR AND WINDOWS TO VERIFY | | | SIZE OF STRUCTURAL BUCK REQUIRED AND PROVIDE STRUCTURAL | | | BUCK DETAILS FOR EXTERIOR DOOR AND WINDOWS. SEE SEC. | | | R613.6.2 OF 2004 FLORIDA RESIDENTIAL CODE FOR PROPER | | | WAY OF INSTALLING THE BUCKS. | | | | | | 5- SPECIFY WINDOW AND DOOR LINTELS. SEC. 106.1.2 CITY | | | AMENDMENTS TO FBC 2004. | | | | | | 6- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE | | | 9B-72 FOR: | | | A) PRECAST LINTELS (IF SPECIFIED ON PLANS). | | | | | | 7-ARCHITECT TO REVIEW AND APPROVE IN WRITING (NOT | | | SIGNING AND SEALING)ALL PRODUCT APPROVALS AS | | | REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004. | | | | | | 8- ENERGY CALCULATIONS: | | | A) PROVIDE CURRENT AND REVISED FORM 600C-04 R. | | | | | | B) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM TOO. | | | | | | 9- WALL SECTION: | | | A) SPECIFY FIREBLOCKING AS REQUIRED BY SEC. R602.1.2 | | | OF 2004 FLORIDA RESIDENTIAL CODE. | | | | | | B) HOW IS THE DRYWALL AND INSULATION INSTALLED. | | | DETAIL SHOWN IS INCOMPLETE. SEC. 106.1.2 CITY | | | AMENDMENTS TO FBC 2004. | | | | | | 10- STORM SHUTTERS: | | | A) DRAWINGS SUBMITTED DON'T CORRESPOND TO NOA | | | #02-0826.07 AND ARE INCOMPLETE. PROVIDE CORRECT AND | | | COMPLETE DRAWINGS. | | | | | | B) PROVIDE COMPLETE INSTALLATIONSCHEDULE AND MARK | | | ON DRAWINGS SPECIFIC ANCHOR TYPE AND SPACING TO BE | | | USED.SEE ATTACHED SAMPLE OF INSTALLATION SCHEDULE. | | | SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004. | | | | | | 11- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY | | | SEC. 713.13 FLORIDA STATUTE. | | | | | | JULIO GOMEZ | | | BUILDING PLANS EXAMINER | | | (561)805-6712 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-05-31 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-05-31 |
Time |
11:08 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-05-31 |
Time |
08:26 |
Sent To |
M |
|
| Notes |
| 2007-05-31 11:08:24 | | | | | | | R313.1.1 SMOKE ALARMS SHALL BE LOCATED AS REQUIRED IN | | | NEW DWELLINGS WHEN REPAIRS OR ADDITIONS REQUIRING A | | | PERMIT OCCUR. SEE ARTICLE FOR COMPLETE TEXT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-04-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-04-12 |
Time |
13:14 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2007-04-12 |
Time |
13:14 |
Sent To |
M |
|
| Notes |
| 2007-04-27 10:04:38 | | | | | | | | | | DENIED | | | | | | PER DEFINITION 13-2 FBC, THE AREA DESIGNATED "STORAGE" | | | ON THE PLAN, IS A BEDROOM. INSTALL SMOKE ALARMS PER | | | 313.1.1 FBC ON THE PLAN AND REFERENCE AFCI PROTECTION | | | PER 210.12 NEC 2005. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-05-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-25 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-25 |
Time |
16:05 |
Sent To |
E |
|
| Notes |
| 2007-05-25 16:05:53 | TO "BTROBAUGH" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-05-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-22 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-22 |
Time |
10:08 |
Sent To |
Z |
|
| Notes |
| 2007-05-22 10:08:36 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-04-10 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-10 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-10 |
Time |
11:45 |
Sent To |
E |
|
| Notes |
| 2007-04-10 11:45:44 | TO "SFR" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-04-27 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2007-04-27 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2007-03-30 |
Time |
17:28 |
Sent To |
|
|
| Notes |
| 2007-03-30 17:28:44 | TO ZONING |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
N |
Date |
2007-05-31 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-05-31 |
Time |
11:34 |
Rev Time |
0.15 |
| Received By |
tgordon |
Date |
2007-05-31 |
Time |
11:34 |
Sent To |
B |
|
| Notes |
| 2007-05-31 11:37:10 | NO MECHANICAL PLANS SUBMITTED, AND NO | | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | | THIS TIME. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-04-13 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-04-27 |
Time |
10:21 |
Rev Time |
0.20 |
| Received By |
tgordon |
Date |
2007-04-13 |
Time |
10:31 |
Sent To |
P |
|
| Notes |
| 2007-04-13 10:36:38 | *** DENIED *** | | | 1) ENERGY CALCULATIONS NEED TO BE ON FORM 600C-04R | | | (SHORT FORM), PER 2004 FBC 13-600.3.C (12-8-06 | | | REVISION). | | | | | | 2) PLEASE HAVE REVISED ENERGY CALCULATIONS SIGNED BY | | | OWNER/AGENT ALSO, PER 2004 FBC 13-600.3.ABC.2. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2007-04-24 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-04-24 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-04-24 |
Time |
09:23 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-05-24 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-05-24 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-05-23 |
Time |
15:39 |
Sent To |
I |
|
| Notes |
| 2007-05-24 17:13:18 | PER ERIC SCHNEIDER, PRINCIPAL PLANNER. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-04-09 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-04-09 |
Time |
19:44 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-04-09 |
Time |
14:42 |
Sent To |
I |
|
| Notes |
| 2007-04-09 19:45:04 | PLANNING AND ZONING DEPARTMENT | | | | | | ***FAILED*** | | | | | | 1. BUILDING STRUCTURE IS ENCROACHING INTO THE REQUIRED | | | REAR SETBACK.THUS, THE WINDOW AIR-CONDITIONING UNIT | | | MAY NOT ENCROACH FURTHER INTO THE SETBACK. | | | | | | 2. A/C UNIT SHALL BE RELOCATED ELSEWHERE IN THE | | | BUILDING.PLEASE NOTE THAT PER SECTION 94-305(A)(4), | | | WINDOW AIR-CONDITIONING UNITS MAY NOT PROJECT MORE THAN | | | 18 INCHES INTO ANY REQUIRED SIDE SETBACK. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|