Plan Review Details - Permit 07031054
Plan Review Stops For Permit 07031054
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-06-07 Cont ID  
Sent By jgomez Date 2007-06-07 Time 13:50 Rev Time 0.00
Received By jgomez Date 2007-06-07 Time 13:50 Sent To PC
Notes
2007-06-07 13:55:06BUILDING REVIEW APPROVED WITH PROVISO:
 1- ARCHITECT TO PROVIDE STRUCTURAL BUCK DETAIL FOR
 SWING DOOR.DETAIL SHOWN ON PLANS IS FOR SLIDING GLASS
 DOORS. ON THE OTHER HAND ARCHITECT TO SEE SWING DOOR
 PRODUCT APPROVAL FOR REQUIRED STRUCTURAL BUCK SIZE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-04-27 Cont ID  
Sent By jgomez Date 2007-04-27 Time 10:49 Rev Time 0.00
Received By jgomez Date 2007-04-27 Time 07:37 Sent To PC
Notes
2007-04-27 11:10:51BUILDING REVIEW CHECKLIST:
  
 1- ARCHITECT TO PROVIDE FIRM'S NUMBER IN THE TITLE
 BLOCK ASREQUIRED BY SEC. 61G1-16.004 FLORIDA
 ADMINISTRATIVE CODE.
  
 2- ROOM CALLED STORAGE IS A BEDROOM.BEDROOM WINDOW
 DOESN'T COMPLY WITH SECTION R310 OF 2004 FLORIDA
 RESIDENTIAL CODE. REVISE AS REQUIRED.
  
 3- AFTER PLANS ARE REVISED BRING THEM TO PALM BEACH
 COUNTY (2300 N. JOG RD (561)233-5115)TO VERIFY IF
 IMPACT FEES ARE DUE.BRING BACK STAMPED PLANS AND COPY
 OF PAID RECEIPT IF FEES ARE DUE.
  
 4- SEE PRODUCT APPROVAL FOR DOOR AND WINDOWS TO VERIFY
 SIZE OF STRUCTURAL BUCK REQUIRED AND PROVIDE STRUCTURAL
 BUCK DETAILS FOR EXTERIOR DOOR AND WINDOWS. SEE SEC.
 R613.6.2 OF 2004 FLORIDA RESIDENTIAL CODE FOR PROPER
 WAY OF INSTALLING THE BUCKS.
  
 5- SPECIFY WINDOW AND DOOR LINTELS. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 6- PROVIDE PRODUCT APPROVAL AS REQUIRED BY DCA RULE
 9B-72 FOR:
 A) PRECAST LINTELS (IF SPECIFIED ON PLANS).
  
 7-ARCHITECT TO REVIEW AND APPROVE IN WRITING (NOT
 SIGNING AND SEALING)ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 106.3.3 CITY AMENDMENTS TO FBC 2004.
  
 8- ENERGY CALCULATIONS:
 A) PROVIDE CURRENT AND REVISED FORM 600C-04 R.
  
 B) OWNER/AGENT TO SIGN AND DATE BOTTOM OF FORM TOO.
  
 9- WALL SECTION:
 A) SPECIFY FIREBLOCKING AS REQUIRED BY SEC. R602.1.2
 OF 2004 FLORIDA RESIDENTIAL CODE.
  
 B) HOW IS THE DRYWALL AND INSULATION INSTALLED.
 DETAIL SHOWN IS INCOMPLETE. SEC. 106.1.2 CITY
 AMENDMENTS TO FBC 2004.
  
 10- STORM SHUTTERS:
 A) DRAWINGS SUBMITTED DON'T CORRESPOND TO NOA
 #02-0826.07 AND ARE INCOMPLETE. PROVIDE CORRECT AND
 COMPLETE DRAWINGS.
  
 B) PROVIDE COMPLETE INSTALLATIONSCHEDULE AND MARK
 ON DRAWINGS SPECIFIC ANCHOR TYPE AND SPACING TO BE
 USED.SEE ATTACHED SAMPLE OF INSTALLATION SCHEDULE.
 SEC. 106.1.2 CITY AMENDMENTS TO FBC 2004.
  
 11- NEED RECORDED NOTICE OF COMMENCEMENT AS REQUIRED BY
 SEC. 713.13 FLORIDA STATUTE.
  
 JULIO GOMEZ
 BUILDING PLANS EXAMINER
 (561)805-6712

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-05-31 Cont ID  
Sent By btrobaug Date 2007-05-31 Time 11:08 Rev Time 0.50
Received By btrobaug Date 2007-05-31 Time 08:26 Sent To M
Notes
2007-05-31 11:08:24 
  
 R313.1.1 SMOKE ALARMS SHALL BE LOCATED AS REQUIRED IN
 NEW DWELLINGS WHEN REPAIRS OR ADDITIONS REQUIRING A
 PERMIT OCCUR. SEE ARTICLE FOR COMPLETE TEXT.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2007-04-27 Cont ID  
Sent By btrobaug Date 2007-04-12 Time 13:14 Rev Time 0.33
Received By btrobaug Date 2007-04-12 Time 13:14 Sent To M
Notes
2007-04-27 10:04:38 
  
  
 DENIED
  
 PER DEFINITION 13-2 FBC, THE AREA DESIGNATED "STORAGE"
 ON THE PLAN, IS A BEDROOM. INSTALL SMOKE ALARMS PER
 313.1.1 FBC ON THE PLAN AND REFERENCE AFCI PROTECTION
 PER 210.12 NEC 2005.
  
 IF THERE ARE ANY QUESTIONS PLEASE CALL.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH
 561/805-6718
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-05-25 Cont ID  
Sent By adarroug Date 2007-05-25 Time 16:05 Rev Time 0.00
Received By adarroug Date 2007-05-25 Time 16:05 Sent To E
Notes
2007-05-25 16:05:53TO "BTROBAUGH" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-05-22 Cont ID  
Sent By adarroug Date 2007-05-22 Time 10:08 Rev Time 0.00
Received By adarroug Date 2007-05-22 Time 10:08 Sent To Z
Notes
2007-05-22 10:08:36TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-04-10 Cont ID  
Sent By adarroug Date 2007-04-10 Time 11:45 Rev Time 0.00
Received By adarroug Date 2007-04-10 Time 11:45 Sent To E
Notes
2007-04-10 11:45:44TO "SFR" "E"

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-04-27 Cont ID  
Sent By jgomez Date 2007-04-27 Time 11:11 Rev Time 0.00
Received By jgomez Date 2007-03-30 Time 17:28 Sent To  
Notes
2007-03-30 17:28:44TO ZONING

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2007-05-31 Cont ID  
Sent By tgordon Date 2007-05-31 Time 11:34 Rev Time 0.15
Received By tgordon Date 2007-05-31 Time 11:34 Sent To B
Notes
2007-05-31 11:37:10NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-04-13 Cont ID  
Sent By btrobaug Date 2007-04-27 Time 10:21 Rev Time 0.20
Received By tgordon Date 2007-04-13 Time 10:31 Sent To P
Notes
2007-04-13 10:36:38*** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE ON FORM 600C-04R
 (SHORT FORM), PER 2004 FBC 13-600.3.C (12-8-06
 REVISION).
  
 2) PLEASE HAVE REVISED ENERGY CALCULATIONS SIGNED BY
 OWNER/AGENT ALSO, PER 2004 FBC 13-600.3.ABC.2.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2007-04-24 Cont ID  
Sent By jleech Date 2007-04-24 Time 09:23 Rev Time 0.00
Received By jleech Date 2007-04-24 Time 09:23 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2007-05-24 Cont ID  
Sent By adavila Date 2007-05-24 Time 17:13 Rev Time 0.00
Received By adavila Date 2007-05-23 Time 15:39 Sent To I
Notes
2007-05-24 17:13:18PER ERIC SCHNEIDER, PRINCIPAL PLANNER.

Review Stop Z ZONING
Rev No 1 Status F Date 2007-04-09 Cont ID  
Sent By adavila Date 2007-04-09 Time 19:44 Rev Time 0.00
Received By adavila Date 2007-04-09 Time 14:42 Sent To I
Notes
2007-04-09 19:45:04PLANNING AND ZONING DEPARTMENT
  
 ***FAILED***
  
 1. BUILDING STRUCTURE IS ENCROACHING INTO THE REQUIRED
 REAR SETBACK.THUS, THE WINDOW AIR-CONDITIONING UNIT
 MAY NOT ENCROACH FURTHER INTO THE SETBACK.
  
 2. A/C UNIT SHALL BE RELOCATED ELSEWHERE IN THE
 BUILDING.PLEASE NOTE THAT PER SECTION 94-305(A)(4),
 WINDOW AIR-CONDITIONING UNITS MAY NOT PROJECT MORE THAN
 18 INCHES INTO ANY REQUIRED SIDE SETBACK.
  
 COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.