| Plan Review Stops For Permit 07030982 |
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
N |
Date |
2007-08-07 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-08-07 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-08-07 |
Time |
15:01 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-04-26 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-04-26 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-04-26 |
Time |
10:29 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-04-19 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-04-19 |
Time |
11:40 |
Rev Time |
1.00 |
| Received By |
btrobaug |
Date |
2007-04-19 |
Time |
11:09 |
Sent To |
B |
|
| Notes |
| 2007-04-19 11:40:07 | | | | INCOMPLETE INFORMATION | | | | | | PROVIDE INFORMATION REGARDING SERVICE RATING, 1 OR 3 | | | PHASE, VOLTAGE AND AMPERAGE. PROVIDE A RISER PER 215.5, | | | OVERCURRENT PROTECTION FOR THE EQUIPMENT PER 240 AND | | | 430, ALL CONDUIT AND CONDUCTOR TYPES AND SIZES. ALL | | | DISCONNECT LOCATIONS AS REQUIRED PER 225. | | | | | | SUBMIT SPECIFICATIONS FOR THE GEAR BEING INSTALLED. | | | | | | THE PERSON TAKING RESPONSIBILITY FOR THE DESIGN MUST | | | PRINT AND SIGN THEIR NAME TO SAME PER 106.3.4.3. FBC. | | | IF AN ARCHITECT OR ENGINEER, COMPLY WITH 418 AND 417 | | | FS, RESPECTIVELY. THE CONTRACTOR OF RECORD MAY BE THE | | | DESIGN PROFESSIONAL IF EXEMPTIONS UNDER THOSE STATUTES | | | ARE APPLICABLE. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2007-12-17 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-12-17 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-12-17 |
Time |
10:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2007-08-15 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-08-15 |
Time |
11:45 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-08-15 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2007-08-15 11:45:40 | ***FAILED**** PLEASE PROVIDE THE FOLLOWING: | | | | | | 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI). | | | PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR | | | NOI. | | | YOU CAN GET NOI INFO FROM | | | WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/ | | | NOTICE OF INTENT DEP FORM 62-621.300(4)(B), | | | EFFECTIVE MAY 1, 2003 | | | 2. PLEASE SHOW ON DRAWINGSTHE LOCATION OF DUMPSTER & | | | ITS ENCLOSURE PER CITY OF WPB, LOCATION MUST BE | | | ACCESSIBLE FOR PICKUP TRUCK. | | | 3.PLEASE PROVIDECENTER LINE OF ROAD , SIDEWALK | | | ELEVATION & GRADE ELEVATION TO MEET FLOOD ZONE AREA, & | | | 5,10, 25, 100 YEAR FLOOD CRITERIA. PLEASE SHOW IN YOUR | | | STORM WATER QUALITY CALS. | | | 4. PLEASE PROVIDE TOTAL SITE AREA, PERVIOUS, IMPERVIOUS | | | AREA, PRE & POST.MAKE SURE THESE SITE AREAS SHOWN ON | | | DRAWINGS MUST MATCH WITH AREAS USED IN STORM WATER | | | QUALITY CALCULATIONS. | | | 5. PLEASE SHOW ON YOUR DRAWINGS ALL STORM WATER PIPES | | | AROUND YOUR SITE SO, WE CANSEE THE LAYOUT OF STORM | | | WATER PIPES.PLEASE SHOW DETAIL OF THE CONTROL | | | STRUCTURESWITH ELEVATIONS, NOTCHES, BLEEDING | | | ELEVATION, ETC ON DRAWINGS, DO YOU HAVE EXFILTRATION | | | TRENCHES. PLEASE SHOW DRY DETENTION/WET DETENTION | | | AREAS. | | | 6. PLEASE PROVIDE A COPY OF GEO-TECH REPORT AND A | | | LATESTEST COPY OF STORM STORM WATER QUALITY | | | CALCULATIONS, PLEASE RESUBMIT NPBCID COPY & SFWMD COPY | | | THAT YOU PROVIDED. | | | 7. PLEASE SHOW ON DRAWINGS THE POLLUTION PREVENTION | | | DETAILS,CLOTHES USED FOR SILT ETC., PLANS MUST SHOW | | | SILT FENCE AROUND THE WHOLE SITE ALONG THE GOLF COURSE | | | RESIDENTS LIVE& NOT ONLY ON CATCH BASINS & UPSTREAM | | | OF CULVERT .HEIGHT OF FENCE SHOULD BE HIGH ENOUGH PER | | | FDEP TO STOP DUST & PARTICLES. | | | 8. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH | | | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED. | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-12-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-12-14 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-12-14 |
Time |
14:39 |
Sent To |
ENG |
|
| Notes |
| 2007-12-14 14:39:37 | TO "ENG" BOX/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-07-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-28 |
Time |
13:14 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-28 |
Time |
13:14 |
Sent To |
E |
|
| Notes |
| 2007-07-28 13:14:59 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-04-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-23 |
Time |
13:55 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-23 |
Time |
13:55 |
Sent To |
E |
|
| Notes |
| 2007-04-23 13:55:35 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-04-23 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-04-19 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-03-28 |
Time |
17:23 |
Sent To |
|
|
| Notes |
| 2007-03-28 17:23:55 | TO PLUMBING BOX |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
N |
Date |
2007-08-10 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-08-10 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-08-10 |
Time |
14:33 |
Sent To |
ENG |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-05-01 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-05-01 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-05-01 |
Time |
08:44 |
Sent To |
PC |
|
| Notes |
| 2007-05-01 08:54:30 | ****************PROVISO**************** | | | NOTE: THIS PERMIT IS FOR THE SITE IRRIGATION ONLY. THE | | | PUMP HOUSE WITH THE CONTROLLER, RAIN SENSOR, AND | | | IRRIGATION PUMPS ARE UNDER A SEPERATE PERMIT. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-04-16 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-04-16 |
Time |
10:20 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2007-04-16 |
Time |
10:20 |
Sent To |
E |
|
| Notes |
| 2007-04-16 11:39:33 | DENIED PLAN REVIEW ONLY, NOT FOR PERMIT: REFERENCE: | | | ** FBC-2004 PLUMBING. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE. | | | ** FLORIDA STATUTES. | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. THE DESIGN PROFESSIONAL IS REQUIRED BY CHAPTER 481, | | | FLORIDA STATUTES PART 1, TO AFFIX HIS OR HER OFFICIAL | | | SEAL, SIGNATURE AND DATE TO SAID DRAWINGS. | | | | | | 2. THE ARCHITECTS FLORIDA REGESTERED LICENSE NUMBER | | | MUST BE ON THE TITLE BLOCK OF THE DRAWING. FLORIDA | | | STATUTES 63G-16.004. | | | | | | 3. PLEASE PROVIDE THE FOLLOWING INFORMATION ON THE | | | RESUBMITTED DRAWINGS. | | | A} AUTOMATIC IRRIGATION CONTROLLER: THE CONTROLLER | | | SHALL BE CAPABLE OF INCORPORATING A RAIN SHUT OFF | | | DEVICE TO OVERRIDE THE IRRIGATION CYCLE WHEN ADEQUATE | | | RAINFALL HAS OCCURED, AS REQUIRED BY FLORIDA STATUTES, | | | SECTION 373.62. | | | B} THE RAIN SWITCH SHALL BE PLACED ON A STATIONARY | | | STRUCTURE MINIMUM OF 5-FOOT (1524MM) CLEARANCE FROM | | | OTHER OUTDOOR EQUIPMENT, FREE AND CLEAR OF ANY TREE | | | CANOPY OR OTHER OVERHEAD OBSTRUCTIONS, AND ABOVE THE | | | HEIGHT OF THE SPRINKLER COVERAGE. | | | | | | 4. SHEET IRR 10 WET/WELL INTAKE FLUME DETAIL: PLEASE | | | INDICATE THE WATER SOURCE (LAKE OR CANNEL) FOR THE WET | | | WELL THROUGH THE 24" X 100' SDR 35 PVC INTAKE FLUME ON | | | THE RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 |
|
|