Plan Review Details - Permit 07030930
| Plan Review Stops For Permit 07030930 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-04-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-04-26 |
Time |
14:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-04-26 |
Time |
14:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-04-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-04-18 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-04-18 |
Time |
14:28 |
Sent To |
|
|
| Notes |
| 2007-04-18 14:29:50 | CORRECTIONS | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | | FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | FROM PREVIOUS LIST, COMMENTS NOT ADDRESSED (SAME | | | PAPERWORK SUBMITTED) | | | | | | 4.)FOR THE FLAT DECK, SELECT THE APPROVED ASSEMBLY | | | YOU ARE USING.ALSO INDICATE WHICH FASTENER YOU ARE | | | USING IF THE OPTIONS HAVE DIFFERENT PRESSURE | | | LIMITATIONS. | | | | | | A TAB WAS PLACED ON ONE OF THE PAGES.THIS IS THE LIST | | | OF PRODUCTS, PAGE 2.THE APPROVED ASSEMBLIES START ON | | | PAGE 6. | | | | | | 5.)FOR THE FLAT DECK, SPECIFY THE ENHANCED FASTENING | | | FOR CORNER AND PERIMETER ZONES. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-04-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-04-10 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-04-10 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2007-04-10 15:12:37 | CORRECTIONS | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FACFLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | FROM PREVIOUS LIST, COMMENTS NOT ADDRESSED (SAME | | | PAPERWORK SUBMITTED) | | | | | | 1.)PRODUCT APPROVALS ARE TO BE APPROVED BY DESIGNER | | | OF RECORD, FBC*106.3.3. | | | | | | 2.)PROVIDE SQUARE FOOT AREA OF EACH TYPE OF ROOF; | | | FLAT AND SHINGLE. | | | | | | 3.).)FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED IN ADDITION TO THE EVALUATION REPORT | | | SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG | | | | | | 4.)FOR THE FLAT DECK, SELECT THE APPROVED ASSEMBLY | | | YOU ARE USING.ALSO INDICATE WHICH FASTENER YOU ARE | | | USING IF THE OPTIONS HAVE DIFFERENT PRESSURE | | | LIMITATIONS. | | | | | | 5.)FOR THE FLAT DECK, SPECIFY THE ENHANCED FASTENING | | | FOR CORNER AND PERIMETER ZONES. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-03-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-03-27 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-03-27 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2007-03-27 13:26:46 | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FBC2004 | | | FACFLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.)PRODUCT APPROVALS ARE TO BE APPROVED BY DESIGNER | | | OF RECORD, FBC*106.3.3. | | | | | | 2.)PROVIDE SQUARE FOOT AREA OF EACH TYPE OF ROOF; | | | FLAT AND SHINGLE. | | | | | | 3.).)FLORIDA STATE OR LOCAL PRODUCT APPROVAL | | | REQUIRED IN ADDITION TO THE EVALUATION REPORT | | | SUBMITTED, FAC9B72.WWW.FLORIDABUILDING.ORG | | | | | | 4.)FOR THE FLAT DECK, SELECT THE APPROVED ASSEMBLY | | | YOU ARE USING.ALSO INDICATE WHICH FASTENER YOU ARE | | | USING IF THE OPTIONS HAVE DIFFERENT PRESSURE | | | LIMITATIONS. | | | | | | 5.)FOR THE FLAT DECK, SPECIFY THE ENHANCED FASTENING | | | FOR CORNER AND PERIMETER ZONES. | | | |
|
|
|