| Plan Review Stops For Permit 07030885 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
3 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
F |
Date |
2007-05-23 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2007-05-23 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2007-05-23 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2007-05-23 13:41:44 | THE APPLICANT'S REPRESENTATIVE CLARIFIED , ON MAY 22, | | | THAT THE JOB LOCATION IS ATUNIT 206 - PHYSICIANS | | | WEIGHT LOSS -UNDER THE ADDRESS OF 8983 OKEECHOBEE | | | BLVD # 206 .PLEASE REVISE SITE PLANS AND APPLICATIONS | | | WITH THE CORRECT SITE ADDRESS. | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | OFFICE:822-1239 | | | FAX: 822-1249 | | | E-MAIL:[email protected] |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2007-04-11 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2007-04-11 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2007-04-11 |
Time |
10:39 |
Sent To |
|
|
| Notes |
| 2007-04-11 16:11:12 | SITE ADDRESS USED ON THE APPLICATION IS 8989 OKEECHOBEE | | | BLVD # 206 .THIS SITE ADDRESS IS USED FOR THE ENTIRE | | | PLAZA AS THE MAIN ADDRESS , HOWEVER THREE BUILDINGS | | | HAVING THREE UNIQUE ADDRESSES ARE LOCATED ON THIS | | | PARCEL WITH PCN = 74424320080030000.THEY ARE 8955 | | | OKEECHOBEE BLVD ,8983 OKEECHOBEE BLVDAND 8993 | | | OKEECHOBEE BLVD .PLEASE CLARIFY IN WHICH OF THESE | | | BUILDINGS UNIT 206 IS LOCATED. | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | OFFICE:822-1239 | | | FAX: 822-1249 | | | E-MAIL:[email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-06-16 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-06-16 |
Time |
07:01 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-06-16 |
Time |
06:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-05-29 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-05-29 |
Time |
06:44 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-05-25 |
Time |
14:21 |
Sent To |
PC |
|
| Notes |
| 2007-05-25 16:57:29 | BUILDING PLAN REVIEW | | | PERMIT:07030885 | | | ADD:8989 | | | CONT: | | | TEL: (561)###-#### | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2)THE VALUE IS LOW. IF IN THE OPINION OF THE BUILDING | | | OFFICIAL, THE CLAIMED VALUATION OF BUILDING, | | | ALTERATION, STRUCTURE, ELECTRICAL, GAS, MECHANICAL OR | | | PLUMBING SYSSTEMS APPEARS TO BE UNDERESTIMATED ON THE | | | APPLICATION, THE PERMIT SHALL BE DENIED, FOR PERMITTING | | | PURPOSES, INCLUDE THE TOTAL VALUE OF THE PROJECT | | | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC | | | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES | | | PER 108.3 FBC*. | | | | | | 3) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF | | | THE COURT. | | | NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS | | | NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE | | | RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: | | | 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT | | | THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-03-31 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-03-31 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-03-31 |
Time |
06:53 |
Sent To |
|
|
| Notes |
| 2007-03-31 10:40:01 | BUILDING PLAN REVIEW | | | PERMIT: 07030885 | | | ADD: 8989 OKEECHOBEE BLVD | | | CONT: KULKA CONST. | | | TEL: (954)984-9293 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 1ST | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2)110.2* W. P. B. ADMINISTRATIVE | | | CODE, INFORMATION THAT IS REQUIRED FOR | | | RECORD KEEPING & FOR CERTIFICATE OF | | | OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH | | | THE PERMIT WAS ISSUED. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | | WITH THE PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | | IN CHAPTER 6, TABLE 601. | | | D) THE DESIGN OCCUPANT LOAD, SEE 1004. | | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS | | | PROVIDED, WHETHER THE SPRINKLER SYSTEM | | | IS REQUIRED. | | | OF THE BUILDING PERMIT. | | | ------------------------------------- | | | ) NUMBER OF UNITS | | | ) NUMBER OF FLOORS | | | ) NUMBER OF ROOMS | | | ) SQ. FT. FOOTPRINT | | | ) SQ. FT. UNDER ROOF (TOTAL) | | | ) OCCUPANT LOAD | | | | | | | | | 3)SEE 2004 FLORIDA EXISTING BUILDING CODE CH,3 AND | | | INDICATE THE TYPE OF ALTERATION BASE ON THE SCOPE OF | | | WORK. | | | | | | 4)THE VALUE IS LOW. IF IN THE OPINION OF THE BUILDING | | | OFFICIAL, THE CLAIMED VALUATION OF BUILDING ALTERATION, | | | STRUCTURE,ELECTRICAL, GAS, MECHANICAL OR PLUMBING | | | SYSTEMS APPEARS TO BE UNDERESTIMATED ON THE | | | APPLICATION, THE PERMIT SHALL BE DENIED. FOR PERMITTING | | | PURPOSES, INCLUDE THE TOTAL VALUE OF THE PROJECT | | | EXCLUDING LAND VALUE. OUR VALUATION REFERENCE IS ICC | | | (BVD), MARSHALL-SWIFT AND MEANS COST ANALYSIS SERVICES | | | PER 108.3 FBC* | | | | | | 5)FBC 11-7.2(2)COUNTERS THAT MAY NOT HAVE A CASH | | | REGISTER BUT AT WHICH GOODS OR SERVICES ARE SOLD OR | | | DISTRIBUTED EITHER (1) A PORTION OF THE MAIN COUNTER IS | | | A MINIMUM OF 36 INCHES IN LENGTH AND A MAXIMUM HEIGHT | | | OF 36 INCHES OR ONE OF THE OTHER OPTIONS MENTION IN | | | THIS SECTION. SHOW THE ELEVATION DETAIL COMPLYING WITH | | | THIS SECTION. | | | | | | 6)THE PARTITION LEGEND ON SHEET A-1.0DOES NOT | | | CORRESPOND WITHE THE FLOOR PLAN. THE LEGEND HAS WALL | | | TYPES 1 AND 2. HOWEVER, THE FLOOR PLAN SHOWS WALL TYPES | | | 1 AND 1A. INCATE CLEARLY ON THE DRAWINGS WHERE WALL | | | DETAIL #3 WILL BE CONSTRUCTED. | | | FBC.106.1.1CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE CODE AND RELEVANT LAWS,ORDINANCES, | | | RULES AND REGULATIONS DETERMINED BY THE BUILDING | | | OFFICIAL. | | | | | | 7) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF | | | THE COURT. | | | NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS | | | NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE | | | RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: | | | 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT | | | THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 8)WILL THE LOW WALLS BE ATTATCHED TO THE CEILING OR | | | WILL THEY BE FREE STANDING? | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-06-08 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-08 |
Time |
19:55 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-08 |
Time |
19:01 |
Sent To |
|
|
| Notes |
| 2007-06-08 19:55:38 | ** UNSAT 3RD REVIEW * | | | | | | ** PLEASE SEE SOME ITEMS FROM PREVIOUS REVIEWS STILL | | | NEED TO BE ADDRESSED. PLEASE SEE NEW COMMENTS BASED ON | | | PLANS SUBMITTED. | | | | | | 1) NOTE: PLEASE SEE COMPLIANCE WITH FBC 2004 CHAPTER | | | 13, 13-415.1.ABC.1.1, AND .1.2 HAS NOT BEEN MET. | | | PLEASE SEE NO TIMES ON DEVICES AS NOTED. | | | PLEASE SEE NO TIMES ON SYSTEM OR OVER RIDES AS TIMER | | | TYPE OF SYSTEM IS BEING NOTED AND SHOWN. | | | PLEASE SEE THAT A STRAIGHT 7-DAY DIGITAL TIMERS WITH | | | OUT OVER RIDE CONTROLS AND AUTOMATED SHUT OFF AT | | | SPECIFIC TIMES DOES NOT MEET CODE. | | | PLEASE SEE SPACES FOR DEVICES. | | | PLEASE SEE QUOTING ASHAE IN LIEU OF DETAIL FOR CODE | | | COMPLIANCE CAN NOT BE ACCEPTED. | | | PLEASE SEE THE CODES AS QUOTED FOR ASHAE, AS THE 2004 | | | FBC , W/2006 REVISIONS IS THE LATEST ADOPTED CODE. | | | | | | 2) NOTE: PLEASE SEE CODES AS QUOTED. PLANS INDICATE THE | | | 2005 NFPA-72 (MISPRINT, SHOULD READ 2002). | | | PLEASE SEE BOTH2002 AND 2005 NFPA-70 (NEC0 IS STATED | | | ON PLANS. | | | PLEASE ADJUST. | | | | | | 3) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO | | | REPEAT COMMENTS FOR CODE COMPLIANCE AS NOTED ABOVE IN | | | NOTE #1. | | | PLEASE SEE THE FLORIDA STATUTES REQUIRES A 4X FEE | | | ASSESSED FOR PLAN REVIEW WHEN CODE COMMENTS ARE | | | REPEATED. THIS FEE IS 30% OF THE BASE PERMIT FEE OF THE | | | PORTION ATTRIBUTED TO PLAN REVIEW. THIS 30% OF THE BASE | | | FEE OF $760 IS $228 TIMES FOUR, WHICH IS $912.00 IS DUE | | | BEFORE PLANS CAN BE RE-SUBMITTED FOR REVIEW. | | | PLEASE SEE THAT THE PHONE NUMBER AND E-MAIL ADDRESS HAS | | | BEEN ON PREVIOUS NOTES ON REVIEWS FOR QUESTIONS OR | | | COMMENTS. IT IS RECOMMENDED THAT IF THERE ARE ANY | | | QUESTIONS OR COMMENTS, TO PLEASE CALL TO GO OVER | | | PLANS. | | | | | | ** ONCE AGAIN, IF THERE ARE ANY QUESTIONS, COMMENTS OR | | | NOTES ARE NOT TYPED IN ANY MANOR WHICH IS UNCLEAR, TO | | | PLEASE CONTACT THIS OFFICE/REVIEWER. | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-05-07 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-05-07 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-05-07 |
Time |
15:07 |
Sent To |
|
|
| Notes |
| 2007-05-07 15:38:34 | * UNSAT 2ND REVIEW** | | | | | | ** PLEASE SEE SOME ITEMS FROM PREVIOUS REVIEW STILL | | | NEED TO BE ADDRESSED. | | | | | | | | | 1) NOTE: PLEASE SEE THE 2004 FBC W/ 2006 REVISION AS | | | THE NEW LIGHTING CONTROLS SHALL BE 13-415.1.ABC.1.1, | | | .1.2 AND .1.3. | | | PLEASE INDICATE SCHEDULING FOR THE NEW SYSTEM WHICH IS | | | BEING SHOWN. | | | PLEASE SEE THE PANEL SCHEDULE INDICATES NOTES FOR SOME | | | OCCUPANCY TYPE DEVICES, HOWEVER SYMBOL LEGEND DOES NOT | | | CONTAIN INFORMATION FOR THIS. | | | PLEASE SHOW THE LOCATION OF OVER RIDE DEVICE(S). PLEASE | | | SEE THAT 13-415.1.ABC.1.1, AND .1.2 REQUIRES THE DEVICE | | | TO BE LOCATED SO THAT THE OCCUPANT CAN SEE THE LIGHTING | | | IN WHICH IS BEING OVER RIDDEN OR CONTROLLED. | | | PLEASE SEE ROOMS AND AREAS WHICH CONTAIN FLOOR TO | | | CEILING HEIGHT PARTITIONS IS REQUIRED TO CONTAIN AN | | | OVER RIDE DEVICE OF SOME TYPE. | | | PLEASE BE SURE ALL DEVICES CONTAIN/LIST THE MAXIMUM | | | TIME PERMITTED ON OVER RIDE.(ALREADY INDICATED FOR MAIN | | | OVER-RIDE). | | | * PREVIOUS REVIEW NOTES ** | | | PLEASE SEE THIS IS REQUIRED EVEN IF THE LIGHTING | | | FIXTURES ARE BEING SHOWN AS EXISTING NEW WALLS/BUILD | | | OUT AND CONTROLS ARE BEING INSTALLED. | | | PLEASE SEE THAT DEPENDING ON THE TYPE OF CONTROL | | | DEVICES OR SYSTEM INSTALLED PLEASE INDICATE TIMES ON | | | DEVICES OF TIMERS, OC SENSORS, TYPES ETC. | | | | | | 2) NOTE: PLEASE SEE THE NOTES ON PREVIOUS REVIEW WHICH | | | REQUESTED ALL OLD/VOIDED SHEETS TO BE REMOVED FROM SETS | | | AND NEW REVISED SHEETS TO BE INSERTED INTO COMPLETE | | | SETS FOR REVIEW AND STAMPING. THIS WAS NOT DONE, NEW | | | SHEETS WERE SUBMITTED LOOSELY. | | | | | | 3) NOTE: PREVIOUS REVIEW REQUESTED NEW PERMIT | | | APPLICATION AS NOTED. THIS WAS NOT SUBMITTED. | | | PLEASE SUBMIT A NEW UPDATE PERMIT APPLICATION WHEN | | | PLANS ARE RE-SUBMITTED . PLEASE SEE THE PERMIT | | | APPLICATION SUBMITTED IS DATED FROM 2001. THIS HAS | | | SINCE BEEN REVISED. A NEW BLANK PERMIT APPLICATION IS | | | BEING ATTACHED TO NOTES AS WELL AS THIS CAN BE | | | DOWNLOADED FROM OUR ONLINE WEBSITE. | | | THIS IS REQUIRED. | | | | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-03-31 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-31 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-31 |
Time |
17:12 |
Sent To |
|
|
| Notes |
| 2007-03-31 17:31:57 | * UNSAT ** | | | | | | 1) NOTE: PLEASE KNOW THAT ANY PERMIT APPLICATIONS WHICH | | | ARE SUBMITTED AFTER DECEMBER 8TH, 2006 PLACES PROJECTS | | | UNDER THE NEW CODES ADOPTED BY THE STATE. | | | PLEASE SEE THAT THIS SHALL INCLUDE 2006 REVISIONS TO | | | THE 2004 FBC FOR ALL TRADES AND THE 2005 NFPA-70. | | | PLEASE KNOW THERE ARE CHANGES IN THE FBC WHICH MAY | | | AFFECT DESIGNS FOR ALL TRADES. | | | PLEASE LIST THE FOLLOWING ON ELECTRICAL SHEETS FOR THIS | | | REVIEWER AT A MINIMUM. | | | 2004 FBC W/ 2006 REVISIONS | | | 2005 NFPA-70 | | | 2002 NFPA-72 | | | 2003 NFPA-101 | | | | | | 2) NOTE: PLEASE SEE MISSING SIGN CIRCUIT PER 600.5, | | | PLEASE INDICATE MINIMUM LOADS REQUIRED. ADJUST LOAD | | | CALCULATIONS. | | | | | | 3) NOTE: PLEASE ALSO SEE 210.62 FOR MISSING WINDOW | | | RECEPTACLES LOADS PER 220.43. PLEASE SEE LOADS ARE | | | BASED ON THE 200VA PER LINEAR FOOT. | | | PLEASE ADJUST. | | | | | | 4) NOTE: PLEASE SEE THE 2004 FBC W/ 2006 REVISION AS | | | THE NEW LIGHTING CONTROLS SHALL BE 13-415.1.ABC.1.1, | | | .1.2 AND .1.3. | | | PLEASE SEE THIS IS REQUIRED EVEN IF THE LIGHTING | | | FIXTURES ARE BEING SHOWN AS EXISTING NEW WALLS/BUILD | | | OUT AND CONTROLS ARE BEING INSTALLED. | | | PLEASE SEE THAT DEPENDING ON THE TYPE OF CONTROL | | | DEVICESOR SYSTEM INSTALLED PLEASE INDICATE TIMES ON | | | DEVICES OF TIMERS, OC SENSORS, TYPES ETC. | | | | | | 5) NOTE: PLEASE SEE PLANS APPEAR TO SHOW THE EMERGENCY | | | AND EXIT LIGHTS BEING WIRED PER 700.12E, HOWEVER THE | | | PANEL SCHEDULE SHOWS THESE ON A DEDICATED CIRCUIT. | | | PLEASE COORDINATE CIRCUITING AND PANEL SCHEDULE. FBC | | | 106.1.2 | | | | | | 6) NOTE: PLEASE SEE RISER SHOWS PANEL AS 150AMP AND THE | | | PANEL SCHEDULE SHOWS THIS AS 200AMPS. | | | PLEASE CORRELATE. | | | FBC 106.1.2 | | | | | | 7) NOTE: PLEASE SUBMIT A NEW UPDATE PERMIT APPLICATION | | | WHEN PLANS ARE RESUBMITTED . PLEASE SEE THE PERMIT | | | APPLICATION SUBMITTED IS DATED FROM 2001. THIS HAS | | | SINCE BEEN REVISED. A NEW BLANK PERMIT APPLICATION IS | | | BEING ATTACHED TO NOTES AS WELL AS THIS CAN BE | | | DOWNLOADED FROM OUR ONLINE WEBSITE. | | | THIS IS REQUIRED. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-06-12 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-06-12 |
Time |
17:42 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-06-12 |
Time |
17:23 |
Sent To |
|
|
| Notes |
| 2007-06-12 17:39:12 | *****APPROVED***** | | | | | | ALL COMMENTS FROM THE PREVIOUS PLAN REVIEW HAVE BEEN | | | ADDRESSED, HOWEVER, THE APPROPIATE PLAN SHEET(S) WILL | | | BE STAMPED WHEN ALL OTHER PLAN REVIEWERS HAVE BEEN | | | SATISFIED. | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2007-05-10 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-05-10 |
Time |
12:20 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-05-10 |
Time |
12:11 |
Sent To |
|
|
| Notes |
| 2007-05-10 12:20:43 | *****DENIED***** | | | | | | THE FOLLWING COMMENTS TAKEN FROM THE PREVIOUS PLAN | | | REVIEW STILL NEED TO BE ADDRESSED: | | | | | | | | | | | | 1.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | | | | 2.THE DEMOLITION OF EXISTING AND/OR THE STOCKING OF | | | NEW BUILDING SUPPLIES & MATERIALS SHALL NOT INTERFERE | | | OR HINDER WITH ACCESS TO OR EGRESS FROM THE PROPERTY OR | | | VICINITY THEREOF (INCLUDING STREETS, ROADS, AND FIRE | | | LANES). | | | | | | 3.WILL THE INSTALLATION OF THE NEW PARTITION WALLS | | | AND DOORS IMPACT THE DISTRIBUTION PATTERN OF THE FIRE | | | SPRINKLER HEADS?IF SO, SEPARATE PLANS AND PERMIT WILL | | | BE REQUIRED FOR THE FIRE SPRINKLER REMODEL. | | | | | | 4.WHEN/IF IT IS NECESSARY TO SHUT DOWN THE FIRE | | | PROTECTION SYSTEM, THE FIRE DEPARTMENT WILL BE NOTIFIED | | | WHEN IT IS SHUT DOWN AND WHEN IT IS RETURNED TO | | | SERVICE. | | | | | | 5.INDICATE THE INTERIOR FINISH CLASSIFICATION FOR THE | | | NEW WALLS AND CEILING TILES AS CLASS A, CLASS B, OR | | | CLASS C.BE SPECIFIC | | | | | | 6.ALL REQUIRED EXIT COMPONENTS WITHIN THE STRUCTURE | | | SHALL BE MAINTAINED. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE (ON THE PLANS) EACH ITEM | | | WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-04-04 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-04-04 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-04-04 |
Time |
15:18 |
Sent To |
|
|
| Notes |
| 2007-04-04 16:08:42 | *****DENIED***** | | | | | | | | | | | | 1.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | | | | 2.THE DEMOLITION OF EXISTING AND/OR THE STOCKING OF | | | NEW BUILDING SUPPLIES & MATERIALS SHALL NOT INTERFERE | | | OR HINDER WITH ACCESS TO OR EGRESS FROM THE PROPERTY OR | | | VICINITY THEREOF (INCLUDING STREETS, ROADS, AND FIRE | | | LANES). | | | | | | 3.WILL THE INSTALLATION OF THE NEW PARTITION WALLS | | | AND DOORS IMPACT THE DISTRIBUTION PATTERN OF THE FIRE | | | SPRINKLER HEADS?IF SO, SEPARATE PLANS AND PERMIT WILL | | | BE REQUIRED FOR THE FIRE SPRINKLER REMODEL. | | | | | | 4.WHEN/IF IT IS NECESSARY TO SHUT DOWN THE FIRE | | | PROTECTION SYSTEM, THE FIRE DEPARTMENT WILL BE NOTIFIED | | | WHEN IT IS SHUT DOWN AND WHEN IT IS RETURNED TO | | | SERVICE. | | | | | | 5.INDICATE THE INTERIOR FINISH CLASSIFICATION FOR THE | | | NEW WALLS AND CEILING TILES AS CLASS A, CLASS B, OR | | | CLASS C.BE SPECIFIC | | | | | | 6.ALL REQUIRED EXIT COMPONENTS WITHIN THE STRUCTURE | | | SHALL BE MAINTAINED. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE (ON THE PLANS) EACH ITEM | | | WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-06-05 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-05 |
Time |
11:23 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-05 |
Time |
11:23 |
Sent To |
|
|
| Notes |
| 2007-06-05 11:23:41 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-05-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-05-03 |
Time |
13:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-05-03 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2007-05-07 13:09:10 | TO "BOB"#1 | | 2007-05-03 13:24:37 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-04-04 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-04-04 |
Time |
15:18 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-03-26 |
Time |
17:12 |
Sent To |
|
|
| Notes |
| 2007-03-31 17:12:57 | TO BOB BOARD #17 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2007-06-12 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-06-12 |
Time |
15:16 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-06-12 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2007-06-12 15:20:34 | MECHANICAL PLAN HAS PASSED REVIEW BUT AS IT IS ON THE | | | SAME PAGE AS THE ELECTRICAL PLAN THAT NEEDS CORRECTIONS | | | MECHANICAL WILL BE STAMPED WHEN THEY PASS ELECTRICAL | | | REVIEW. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-05-08 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-05-08 |
Time |
09:28 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-05-08 |
Time |
09:28 |
Sent To |
|
|
| Notes |
| 2007-05-08 09:38:01 | *** DENIED *** | | | 1) 12"RETURN AIR TRANSFER DUCTS FROM WAITING ROOM NEEDS | | | TO BE 14" AND 12" RETURN AIR TRANSFER DUCT FROM MANAGER | | | OFFICE NEEDS TO BE 16", SEE 2004 FBC/M 601.4 (A), | | | PLEASE CORRECT. | | | | | | *** 2004 FBC/M 601.4. BALANCED RETURN AIR MAY BE | | | ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND ONE HALF TIMES | | | THE CROSS SECTIONAL AREA (SQUARE INCHES) OF THE SUPPLY | | | DUCT ENTERING THE ROOM OR SPACE IT'S SERVING AND THE | | | DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE PROPER RETURN | | | AIR BALANCE. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-03-29 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-29 |
Time |
12:05 |
Rev Time |
0.35 |
| Received By |
tgordon |
Date |
2007-03-29 |
Time |
12:05 |
Sent To |
|
|
| Notes |
| 2007-03-29 12:10:16 | *** DENIED *** | | | 1) SEE MECHANICAL PLANS PAGE A-2.0. NEED TO PROVIDE FOR | | | RETURN AIR TO THE MANAGER'S OFFICE, CONSULT ROOM #1 AND | | | 2, AND THE WAITING ROOM, SEE 2004 FBC/M 601.4. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2007-03-31 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-03-31 |
Time |
06:27 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-03-31 |
Time |
06:27 |
Sent To |
|
|
| Notes |
| 2007-03-31 06:28:03 | NO PLUMBING SHOWN ON PLANS |
|
|