 |
Plan Review Details - Permit 07030860
| Plan Review Stops For Permit 07030860 |
| Review Stop |
AD |
ADDRESSING |
| Rev No |
2 |
Status |
P |
Date |
2007-10-01 |
|
|
Cont ID |
|
| Sent By |
rbrown |
Date |
2007-10-01 |
Time |
16:51 |
Rev Time |
0.00 |
| Received By |
rbrown |
Date |
2007-10-01 |
Time |
16:51 |
Sent To |
|
|
| Notes |
| 2007-10-01 16:56:41 | APPLICANT CORRECTED THE OWNER INFORMATION ON THE | | | APPLICATION FORM. |
|
|
| Review Stop |
AD |
ADDRESSING |
| Rev No |
1 |
Status |
F |
Date |
2007-04-04 |
|
|
Cont ID |
|
| Sent By |
lursu |
Date |
2007-04-04 |
Time |
14:07 |
Rev Time |
0.00 |
| Received By |
lursu |
Date |
2007-04-04 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2007-04-04 14:05:06 | THE SITE ADDRESS ASSIGNED AS 9835 OKEECHOBEE BLVD WITH | | | PARCEL CONTROL NUMBER AS 74 42 43 19 11 002 0020 FOR | | | THIS PROJECT ( THE NEW MCDONALD'S FAST FOOD RESTAURANT | | | ) IS CORRECT . | | | HOWEVER ON THE PERMIT APPLICATION THE PROPERTY OWNER | | | INFORMATION "MCDONALD'S CORP" DOES NOT MATCH WITH THE | | | PROPERTY OWNER INFROMATION FOUND ON THEPROPERTY | | | APPRAISER'S OFFICE WEBSITE .IF THE PROPERTY OWNER | | | INFORMATION ON THE PERMIT APPLICATION IS CORRECT | | | ,PLEASE PROVIDE PROOF OF OWNERSHIP . | | | | | | LACRAMIOARA URSU | | | MIS - GIS SUPPORT SPECIALIST | | | CITY OF WEST PALM BEACH | | | OFFICE:822-1239 | | | FAX: 822-1249 | | | E-MAIL:[email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
9 |
Status |
P |
Date |
2007-12-11 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-12-11 |
Time |
08:28 |
Rev Time |
1.33 |
| Received By |
jwitmer |
Date |
2007-12-11 |
Time |
08:28 |
Sent To |
|
|
| Notes |
| 2007-12-11 08:28:48 | REVISION# 5 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
8 |
Status |
P |
Date |
2007-11-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-11-16 |
Time |
12:29 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-11-16 |
Time |
12:29 |
Sent To |
PC |
|
| Notes |
| 2007-11-16 12:30:42 | REVISION: TRASH CORRAL |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
7 |
Status |
P |
Date |
2007-11-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-11-14 |
Time |
08:32 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2007-11-14 |
Time |
08:32 |
Sent To |
PC |
|
| Notes |
| 2007-11-14 08:33:16 | SHOP DRAWINGS FOR STOREFRONT GLAZING ARCH 3000 SERIES | | | LMI |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2007-11-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-11-01 |
Time |
13:37 |
Rev Time |
0.88 |
| Received By |
jwitmer |
Date |
2007-11-01 |
Time |
11:55 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2007-10-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-10-12 |
Time |
14:06 |
Rev Time |
1.55 |
| Received By |
jwitmer |
Date |
2007-10-12 |
Time |
14:06 |
Sent To |
PC |
|
| Notes |
| 2007-10-12 14:09:14 | LIGHT GAUGE METAL TRUSS SHOP DRAWINGS |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-10-01 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-10-01 |
Time |
16:21 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2007-10-01 |
Time |
16:18 |
Sent To |
|
|
| Notes |
| 2007-10-01 16:26:56 | | | | *** ISSUED PERMIT*** | | | -PLAN REVIEW HISTORY- | | | | | | PERMIT# 07030860 | | | ADDRESS: 9835 OKEECHOBEE BLVD | | | CONT: GIL HYATTCONSTRUCTION INC. | | | TELL # (954)772-2066 | | | | | | THE ATTACHED COMMENTS ARE PART OF THE | | | PERMIT AND PLAN REVIEW PACKAGE AND ARE | | | NOT TO BE REMOVED FROM THE ISSUED SET OF PLANS.106.1.1 | | | ADMINISTRATIVE CODE/ 06. | | | | | | 1) ROOFING SUBPERMIT STRUCK 07030868,FLAT ROOF DECK | | | FL 5754 / MIAMI-DADE NOA 06-0626.09 WITH C-BUCK | | | ENGINEERING REPORT (COPY, NOT SEALED) WAS SUBMITTED FOR | | | SUB-SYSTEM | | | "D-1" WHEN RESEARCHING THE NOA | | | | | | 2) BUILDING PROVISO: 109.3.10* IMPACT OF CONSTRUCTION. | | | ALL CONSTRUCTION ACTIVITY REGULATED BY THIS CODE SHALL | | | BE PERFORMED IN A MANNER SO AS NOT TO ADVERSELY IMPACT | | | THE CONDITION OF ADJACENT PROPERTY, UNLESS SUCH | | | ACTIVITY IS PERMITTED TO AFFECT SAID PROPERTY PURSUANT | | | TO A CONSENT BY THE APPLICABLE PROPERTY OWNER, UNDER | | | TERMS & CONDITIONS AGREEABLE TO THE APPLICABLE PROPERTY | | | OWNER. THIS INCLUDES | | | BUT IS NOT LIMITED TO THE CONTROL OF DUST, NOISE, WATER | | | OR DRAINAGE RUN-OFF, DEBRIS, AND THE STORAGE OF | | | CONSTRUCTION MATERIALS. NEW CONSTRUCTION ACTIVITY SHALL | | | NOT ADVERSELY IMPACT HISTORIC SURFACE WATER DRAINAGE | | | FLOWS SERVING ADJACENT PROPERTIES, & MAY REQUIRE | | | SPECIAL DRAINAGE DESIGN COMPLYING WITH ENGINEERING | | | STANDARDS TO PRESERVE THE POSITIVE PATTERNS OF THE | | | AFFECTED SITES. ACCORDINGLY, DEVELOPERS, CONTRACTORS, | | | AND OWNERS OF ALL NEW RESIDENTIAL DEVELOPMENT, | | | INCLUDING ADDITIONS, POOLS, PATIOS, DRIVEWAYS, DECKS, | | | OR SIMILAR ITEMS, ON EXISTING PROPERTIES RESULTING IN A | | | DECREASE IN EXCESS OF 800SQ FT OF PERMEABLE LAND AREA | | | ON ANY PARCEL SHALL AS A PERMIT CONDITION, PROVIDE A | | | PROFESSIONALLY PREPARED DRAINAGE PLAN CLEARLY | | | INDICATING COMPLIANCE WITH THIS PARAGRAPH. UPON | | | COMPLETION OF THE IMPROVEMENT, A CERTIFICATION FROM A | | | LICENSED ENGINEER SHALL BE SUBMITTED TO THE INSPECTOR | | | IN ORDER TO RECEIVE APPROVAL OF THE FINAL INSPECTION. | | | | | | 3) BUILDING PROVISO: 109.3.10.1 HURRICANE PROTECTION. | | | IT SHALL BE UNLAWFUL FOR ANY PERSON TO ALLOW | | | CONSTRUCTION RELATED MATERIALS EQUIPMENT AND DEBRIS TO | | | REMAIN LOOSE OR OTHERWISE UNSECURED AT A CONSTRUCTION | | | SITE FROM 24 HRS. AFTER A HURRICANE WATCH HAS BEEN | | | ISSUED UNTIL THE HURRICANE WATCH OR WARNING HAS BEEN | | | LIFTED. ALL SUCH CONSTRUCTION MATERIALS, | | | EQUIPMENT AND DEBRIS SHALL BE EITHER REMOVED FROM THE | | | CONSTRUCTION SITE OR SECURED IN SUCH A MANNER AS TO | | | MINIMIZE THE DANGER OF SUCH CONSTRUCTION MATERIALS, | | | EQUIPMENT AND DEBRIS CAUSING DAMAGE TO PERSONS OR | | | PROPERTY FROM HIGH WINDS. ANY PERSONS WHO FAILS TO | | | COMPLY TO REMOVE OR SECURE THE CONSTRUCTION MATERIALS | | | EQUIPMENT AND DEBRIS WITHIN | | | 24 HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE | | | SUBJECT TO A FINE NOT TO EXCEED $500.00. IN ADDITION | | | TO THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS | | | SECTION | | | SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO SECTION 113 | | | OF THIS CHAPTER. | | | | | | 4) BUILDING PROVISO: BILCO (ROOF HATCHES) IS CURRENTLY | | | UNDER GOING TESTING WITH MIAMI-DADE AND REPORTS WILL BE | | | OUT THE SECOND HALF OF 2007. THE CONTRACTOR WILL BE | | | REQUIRED TO SUBMIT PRODUCT APPROVALS THAT HAVE | | | ACCEPTANCE TO THIS OFFICE BEFORE A CERTIFICATE OF | | | OCCUPANCY WILL BE ISSUED. IF AT TIME OF C.O. EITHER AN | | | APPROVAL FROM A STATE LISTED AGENCY WILL BE REQUIRED OR | | | THE CONTRACTOR SHALL APPLY FOR A LOCAL PRODUCT APPROVAL | | | WITH THE CITY OF WEST PALM BEACH WITH THE SAME 10 | | | CRITERIA AS THE STATE APPROVALS BEFORE A CERTIFICATE OF | | | OCCUPANCY WILL BE ISSUED. STATE REQUIREMENTS FOR | | | STRUCTURAL COMPONENTS AS PER RULE 9B-72.010(28), | | | FLORIDA ADMINISTRATIVE CODE AND IS SUBJECT TO THE | | | REQUIREMENTS FOR PRODUCT APPROVAL. | | | | | | 102.1* WHERE, IN ANY SPECIFIC CASE, DIFFERENT SECTIONS | | | OF THIS CODE SPECIFY DIFFERENT MATERIALS, METHODS OF | | | CONSTRUCTION OR OTHER REQUIREMENTS, THE MOST | | | RESTRICTIVE SHALL GOVERN. WHERE THERE IS A CONFLICT | | | BETWEEN A GENERAL REQUIREMENT AND A SPECIFIC | | | REQUIREMENT, THE SPECIFIC REQUIREMENT SHALL BE | | | APPLICABLE. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | BUILDING PLAN REVIEW II | | | | | | | | | | | | | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-09-24 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-09-24 |
Time |
08:17 |
Rev Time |
1.11 |
| Received By |
jwitmer |
Date |
2007-09-24 |
Time |
08:17 |
Sent To |
|
|
| Notes |
| 2007-09-24 08:18:50 | MC DONALD?S 9835 OKEECHOBEE BLVD | | | 3RD REVIEW | | | SEPT 21,2007 | | | | | | BUILDING PLAN REVIEW | | | PERMIT: 07030860 | | | ADD: 9835 OKEECHOBEE BLVD | | | CONT: GIL HYATT CONSTRUCTION | | | TEL: (954)772-2066 | | | ? | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 3RDREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. PLEASE REMOVE | | | VOID SHEETS FROM PLAN AND LOOSELY LAY THEM ON TOP OF | | | THE SET OF PLANS MARKED VOID. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | 2 ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT. | | | NOTE: 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENTIS NOT ACTUALLYCOMMENCED WITHIN 90 DAYS | | | AFTER THE RECORDING THEREOF,SUCH NOTICE IS NULL & | | | VOID. NOTE: 713.13(6)THE POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | 3) PLEASE PROVIDE (2) REPORTS WITH ORIGINAL SIGNATURES | | | NOT COPIED SIGNATURES WITH EMBOSSED SEAL. | | | FBC 1802.2.1 QUESTIONABLE SOILS, WHERE THE | | | SAFE-SUSTAINING POWER OF THE SOIL | | | IS IN DOUBT, OR WHERE A LOAD-BEARING VALUE SUPERIOR TO | | | THAT SPECIFIED IN THIS CODE ISCLAIMED, THE BUILDING | | | OFFICIAL SHALL REQUIRE THAT THE NECESSARY INVESTIGATION | | | BE MADE. SUCH INVESTIGATION SHALL COMPLY WITH THE | | | PROVISIONS OF SECTIONS 1802.4 THROUGH 1802.6 . | | | | | | 4) BUILDING PROVISO:PROVIDE FLOOD ZONE ELEVATION | | | CERTIFICATE FOR NEW CONSTRUCTION WITH BASE FLOOD | | | ELEVATION, CITY CODE REQUIRES | | | AN ADDITIONAL 6". LOCATED IN A A-O) FLOOD ZONE. | | | | | | 5) COMPLIED. | | | | | | 6)COMPLIED. | | | | | | 7)BUILDING PROVISO: BILCO (ROOF HATCHES) IS CURRENTLY | | | UNDER GOING TESTING WITH MIAMI-DADE AND REPORTS WILL BE | | | OUT THE SECOND HALF OF 2007. THE CONTRACTOR WILL BE | | | REQUIRED TO SUBMIT PRODUCT APPROVALS THAT HAVE | | | ACCEPTANCE TO THIS OFFICE BEFORE A CERTIFICATE OF | | | OCCUPANCY WILL BE ISSUED. IF AT TIME OF C.O. EITHER AN | | | APPROVAL FROM A STATE LISTED AGENCY WILL BE REQUIRED OR | | | THE CONTRACTOR SHALL APPLY FOR A LOCAL PRODUCT APPROVAL | | | WITH THE CITY OF WEST PALM BEACH WITH THE SAME 10 | | | CRITERIA AS THE STATE APPROVALS BEFORE A CERTIFICATE OF | | | OCCUPANCY WILL BE ISSUED. STATE REQUIREMENTS FOR | | | STRUCTURAL COMPONENTS AS PER RULE | | | 9B-72.010(28), FLORIDA ADMINISTRATIVE CODE AND IS | | | SUBJECT TO THE REQUIREMENTS FOR PRODUCT APPROVAL.. | | | | | | 8-14) COMPLIED. | | | | | | 15A) THE PRODUCT APPROVALS SUBMITTED ARE UNDER THE 2001 | | | FBC PLEASE PROVIDE THE APPROVALS THAT ARE CURRENTLY | | | UNDER THE 2004 FBC. FL BLD CODE 1609.1.4: COMPONENTS | | | & CLADDING, PROVIDE 2 COPIES(3 IF THRESHOLD OR RESIDENT | | | INSPECTOR) OF PRODUCT TESTING REPORTS, MISSING REPORTS | | | ARE AS FOLLOWS: | | | A) FIXED WINDOWS MISSING THE FL COVER SHEET NOA | | | 05-0906.05 | | | B) DRIVE THROUGH WINDOW- MISSING THE FL COVER SHEET NOA | | | 07-0503.09 | | | C) GLAZED DOORS- MISSING FL COVER SHEET NOA 05-0829.08 | | | D) EXTERIOR HOLLOW METAL DOORS- NO FL COVER SHEET NOR | | | REPORT SUBMITTED | | | E) ROOF HATCH WILL BE A BUILDING PROVISO | | | F) TRUSS ANCHORS ? OK FL COVERSHEET AND REPORTS | | | G) ROOF ASSEMBLIES: | | | FLAT ROOF ? NO FL COVER | | | SHEET NOR REPORT SUBMITTED, HIGHLIGHT | | | | | | SUBSYSTEM TO BE USED ON PROJECT. | | | ROOF TILE-POLYGLASS | | | NOA 06-0505.01 REQUIRES FL COVERSHEET | | | | | | 16)PRODUCT APPROVALS SUBMITTED WITH PERMIT | | | APPLICATION AFTER OCTOBER 1, 2003 ARE REQUIRED TO | | | COMPLY WITH THE FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH STATEWIDE | | | APPROVAL ARE REQUIRED TO BE SUBMITTED WITH A COVER | | | SHEET THAT LISTS THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, | | | SUBMIT AN APPLICATION FOR LOCAL PRODUCT APPROVAL OR | | | SITE SPECIFIC FORM PER RULE 9B-72. | | | WWW.FLORIDABUILDING.ORG | | | | | | 17) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 18-22) COMPLIED. | | | | | | 23)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, | | | IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. THE | | | ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 24 ) BUILDING PROVISO: 109.3.10* IMPACT OF | | | CONSTRUCTION. ALL CONSTRUCTION ACTIVITY REGULATED BY | | | THIS CODE SHALL BE PERFORMED IN A MANNER SO AS NOT TO | | | ADVERSELY IMPACT THE CONDITION OF ADJACENT PROPERTY, | | | UNLESS SUCH ACTIVITY IS PERMITTED TO AFFECT SAID | | | PROPERTY PURSUANT TO A CONSENT BY | | | THE APPLICABLE PROPERTY OWNER, UNDER TERMS & CONDITIONS | | | AGREEABLE TO THE APPLICABLE PROPERTY OWNER. THIS | | | INCLUDESBUT IS NOT LIMITED TO THE CONTROL OF DUST, | | | NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND THE | | | STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION | | | ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE | | | WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY | | | REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE POSITIVE PATTERNS | | | OF THE AFFECTED SITES. ACCORDINGLY, DEVELOPERS, | | | CONTRACTORS, AND OWNERS OF ALL NEW RESIDENTIAL | | | DEVELOPMENT, INCLUDING ADDITIONS, POOLS, | | | PATIOS, DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ | | | FT OF PERMEABLE LAND AREA ON ANY PARCEL SHALL AS A | | | PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED | | | DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS | | | PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A | | | CERTIFICATE FROM A LICENSED ENGINEER SHALL BE SUBMITTED | | | TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL OF THE | | | FINAL INSPECTION. | | | | | | 25) BUILDING PROVISO:109.3.10.1 HURRICANE PROTECTION. | | | IT SHALL BE UNLAWFUL FOR ANY PERSON TO ALLOW | | | CONSTRUCTION RELATED MATERIALS EQUIPMENT AND DEBRIS TO | | | REMAIN LOOSE OR OTHERWISE UNSECURED AT A CONSTRUCTION | | | SITE FROM 24 HRS. AFTER A HURRICANE WATCH HAS BEEN | | | ISSUED UNTIL THE HURRICANE WATCH OR WARNING HAS BEEN | | | LIFTED. ALL SUCH CONSTRUCTION MATERIALS, | | | EQUIPMENT AND DEBRIS SHALL BE EITHER REMOVED FROM THE | | | CONSTRUCTION SITE OR SECURED IN SUCH A MANNER AS TO | | | MINIMIZE THE DANGER OF SUCH CONSTRUCTION MATERIALS, | | | EQUIPMENT AND DEBRIS CAUSING DAMAGE TO PERSONS OR | | | PROPERTY FROM HIGH WINDS. ANY PERSONS WHO FAILS TO | | | COMPLY TO REMOVE OR SECURE THE CONSTRUCTION MATERIALS | | | EQUIPMENT AND DEBRIS WITHIN | | | 24 HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE | | | SUBJECT TO A FINE NOT TO EXCEED $500.00. IN ADDITION | | | TO THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS | | | SECTION | | | SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO SECTION 113 | | | OF THIS CHAPTER. | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-08-18 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-08-18 |
Time |
14:26 |
Rev Time |
4.00 |
| Received By |
jwitmer |
Date |
2007-08-18 |
Time |
10:56 |
Sent To |
PC |
|
| Notes |
| 2007-08-18 14:46:33 | | | | | | | | | | MC DONALD?S 9835 OKEECHOBEE BLVD | | | 2ND REVIEW | | | | | | BUILDING PLAN REVIEW | | | PERMIT: 07030860 | | | ADD: 9835 OKEECHOBEE BLVD | | | CONT: GIL HYATT CONSTRUCTION | | | TEL: (954)772-2066 | | | ?THE CAPITAL CITY OF THE PALM BEACHES? | | | | | | | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND WILL HELP TO EXPEDITE YOUR PERMIT. PLEASE REMOVE | | | VOID SHEETS FROM PLAN AND LOOSELY LAY THEM ON TOP OF | | | THE SET OF PLANS MARKED VOID. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | 2 ) FL S S 713.13NOTICE OF COMMENCEMENT, TO BE FILED | | | WITH THE CLERK OF THE COURT. | | | NOTE: 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENTIS NOT ACTUALLYCOMMENCED WITHIN 90 DAYS | | | AFTER THE RECORDING THEREOF,SUCH NOTICE IS NULL & | | | VOID. NOTE: 713.13(6)THE POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | 3)FBC 1802.2.1 QUESTIONABLE SOILS, WHERE THE | | | SAFE-SUSTAINING POWER OF THE SOIL | | | IS IN DOUBT, OR WHERE A LOAD-BEARING VALUE SUPERIOR TO | | | THAT SPECIFIED IN THIS CODE ISCLAIMED, THE BUILDING | | | OFFICIAL SHALL REQUIRE THAT THE NECESSARY INVESTIGATION | | | BE MADE. SUCH INVESTIGATION SHALL COMPLY WITH THE | | | PROVISIONS OF SECTIONS 1802.4 THROUGH 1802.6 . | | | | | | 4) BUILDING PROVISO:PROVIDE FLOOD ZONE ELEVATION | | | CERTIFICATE FOR NEW CONSTRUCTION WITH BASE FLOOD | | | ELEVATION, CITY CODE REQUIRES | | | AN ADDITIONAL 6". LOCATED IN A A-O) FLOOD ZONE. | | | | | | 5) COMPLIED. | | | | | | 6)COMPLIED. | | | | | | 7)BUILDING PROVISO: BILCO (ROOF HATCHES) IS CURRENTLY | | | UNDER GOING TESTING WITH MIAMI-DADE AND REPORTS WILL BE | | | OUT THE SECOND HALF OF 2007. THE CONTRACTOR WILL BE | | | REQUIRED TO SUBMIT PRODUCT APPROVALS THAT HAVE | | | ACCEPTANCE TO THIS OFFICE BEFORE A CERTIFICATE OF | | | OCCUPANCY WILL BE ISSUED. IF AT TIME OF C.O. EITHER AN | | | APPROVAL FROM A STATE LISTED AGENCY WILL BE REQUIRED OR | | | THE CONTRACTOR SHALL APPLY FOR A LOCAL PRODUCT APPROVAL | | | WITH THE CITY OF WEST PALM BEACH WITH THE SAME 10 | | | CRITERIA AS THE STATE APPROVALS BEFORE A CERTIFICATE OF | | | OCCUPANCY WILL BE ISSUED. STATE REQUIREMENTS FOR | | | STRUCTURAL COMPONENTS AS PER RULE | | | 9B-72.010(28), FLORIDA ADMINISTRATIVE CODE AND IS | | | SUBJECT TO THE REQUIREMENTS FOR PRODUCT APPROVAL.. | | | | | | 8) COMPLIED. | | | | | | 9) 2ND REQUEST, SHEET A5.0- A5.3 ALL SHOW VARIOUS | | | DETAILS INDICATING AN ASSEMBLY TYPE 1 OR 2.SOME OF | | | THESE WALLS ARE BUILT OUT BUT THE FOUNDATIONS ARE NOT | | | NOR IS THERE AN INSPECTION AREA LEFT OPEN. | | | IN ORDER TO PROVIDE FOR INSPECTION FOR TERMITE | | | INFESTATION, CLEARANCE BETWEEN EXTERIOR WALL COVERINGS | | | AND FINAL EARTH GRADE ON THE EXTERIOR OF A BUILDING | | | SHALL NOT BE LESS THAN 6 INCHES (152 MM). EXCEPTIONS: | | | 1.PAINT OR DECORATIVE CEMENTITIOUS FINISH LESS | | | THAN 5 / 8 INCH (17.1 MM) THICK ADHERED DIRECTLY TO THE | | | MASONRY FOUNDATION SIDEWALL. | | | 2.ACCESS OR VEHICLE RAMPS WHICH RISE TO THE | | | INTERIOR FINISH FLOOR ELEVATION FOR THE WIDTH OF SUCH | | | RAMPS ONLY. | | | 3.A 4-INCH (102 MM) INSPECTION SPACE ABOVE PATIO | | | AND GARAGE SLABS AND ENTRY AREAS. | | | 4.IF THE PATIO HAS BEEN SOIL TREATED FOR TERMITES | | | , THE FINISH ELEVATION MAY MATCH THE BUILDING INTERIOR | | | FINISH FLOOR ELEVATIONS ON MASONRY CONSTRUCTION ONLY. | | | 5.MASONRY VENEERS. | | | | | | DETAIL 2 SHEET A5.3 DOESN?T SHOW A SIDEWALK IN PLACE, | | | PLEASE PROVIDE THE DETAIL OF A SIDEWALK AND THE 6? | | | SPACE FOR TERMITE INSPECTIONS. | | | | | | 10) COMPLIED WITH PREVIOUS COMMENT. SHEET A5.0 WALL | | | SYSTEM 2 INDICATES THE USE OF EXTERIOR PLYWOOD,PLEASE | | | REMEMBER THE 6? AIR SPACE REQUIRED FOR THE TERMITE | | | INSPECTION, AND THE REQUIREMENT FOR PRESSURE TREATED | | | SHEATHING WITHIN 6? OF GRADE.2304.11.2.5 CLEARANCE | | | BETWEEN WOOD SIDING AND EARTH ON THE EXTERIOR OF A | | | BUILDING SHALL NOT BE LESS THAN 6 INCHES (152 MM) | | | EXCEPT WHERE SIDING, SHEATHING AND WALL FRAMING ARE OF | | | NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. | | | | | | 11) COMPLIED. | | | | | | 12)2ND REQUEST, RESPONSE COMMENCE INDICATE THERE WERE | | | PRODUCT APPROVALS SUBMITTED FOR REFRIGERATORS AND | | | FREEZERS, COULD NOT LOCATE? | | | A4.1 PLANS INDICATE THERE SHALL BE INSTALLED A WALK IN | | | COOLER AND FREEZER, NO INFORMATION WAS | | | SUBMITTED.2603.4.1.3 WALK-IN COOLERS. | | | IN NON-SPRINKLED BUILDINGS, FOAM PLASTIC HAVING A | | | THICKNESS THAT DOES NOT EXCEED 4 INCHES (102 MM) AND A | | | MAXIMUM FLAME SPREAD INDEX OF 75 IS PERMITTED IN | | | WALK-IN COOLERS OR FREEZER UNITS WHERE THE AGGREGATE | | | FLOOR AREA DOES NOT EXCEED 400 SQUARE FEET (37 M 2 ) | | | AND THE FOAM PLASTIC IS COVERED BY A METAL FACING NOT | | | LESS THAN 0.032-INCH-THICK (0.81 MM) ALUMINUM OR | | | CORROSION-RESISTANT STEEL HAVING A MINIMUM BASE METAL | | | THICKNESS OF 0.016 INCH (0.41 MM). A THICKNESS OF UP TO | | | 10 INCHES (254 MM) IS PERMITTED WHERE PROTECTED BY A | | | THERMAL BARRIER. | | | | | | 13-14) COMPLIED. | | | | | | 15A) THE PRODUCT APPROVALS SUBMITTED ARE UNDER THE 2001 | | | FBC PLEASE PROVIDE THE APPROVALS THAT ARE CURRENTLY | | | UNDER THE 2004 FBC. FL BLD CODE 1609.1.4: COMPONENTS | | | & CLADDING, PROVIDE 2 COPIES(3 IF THRESHOLD OR RESIDENT | | | INSPECTOR) OF PRODUCT TESTING REPORTS, MISSING REPORTS | | | ARE AS FOLLOWS: | | | A) OK-FIXED WINDOWS, STOREFRONT- PROVIDE SHUTTER | | | REPORT MEETS COMPLIANCE | | | B) OK-MULLIONS PROVIDED SHUTTER REPORTS MEETS | | | COMPLIANCE | | | C) OK- PASS THROUGH WINDOW | | | D)OK-GLAZED DOORS PROVIDED SHUTTER REPORTS MEETS | | | COMPLIANCE | | | E)OK- HOLLOW CORE METAL DOORS | | | F)BILCO ROOF HATCH SEE TECHNICAL ADVISORY FROM BCAB | | | ? BUILDING PROVISO | | | G) TRUSS ANCHORS DID NOT SEE REPORT | | | H) STORM SHUTTERS WILL NEED ADDITIONAL INFORMATION | | | LISTED BELOW | | | I) ROOF ASSEMBLIES : FLAT ROOF ?OK | | | ROOF TILE- SEE | | | COMMENT# 20 | | | UNDERLAYMENT FOR ROOF | | | TILE- NOT SUBMITTED | | | J) PRE-MANUFACTURED A/C STANDS- NOT SUBMITTED SHEET | | | M-2 BEVERAGE SYSTEMS CONDENSING | | | UNIT | | | K)OK- EFIS SYSTEMS WALL SYSTEMS, NOTHING FOR MOLDINGS | | | | | | 15B) THE CONTRACTOR HAS ELECTED TO USE NON-IMPACT | | | GLAZING IN THE EXTERIOR DOORS AND WINDOWS.SHEET A4.1 | | | AND 5.0 DO NOT INDICATE OR HAVE BACKING TO SUPPORT | | | STORM PANELS | | | THE CONTRACTOR ELECTED TO USE. NOTE THE PRODUCT | | | APPROVAL TECHNICAL SHEETS (TYPES OF WALL) | | | CONFIGURATIONS THAT STORM PANELS WERE TESTED TO UNDER | | | THE LARGE MISSILE TESTING. BOTH THE PRODUCT APPROVAL | | | AND WALL DETAILS WILL NEED TO BE CORRELATED, HIGHLIGHT | | | THE PRODUCT APPROVAL WALL SECTIONS TO BE USED AND | | | PROVIDE WALL DETAILS ON THE ARCHITECTURAL SHEETS THAT | | | WILL REFLECT THESE SAME DETAILS. NOTE IF WOOD BACKING | | | IS USED THE SHEETS 9-12 DEAL WITH WOOD TYPE BACKED | | | STRUCTURES. A NOTE OF CAUTION, NONE OF THE PRODUCT | | | APPROVALS WERE TESTED WITH A CRUSHABLE INSULATION | | | BACKING! | | | | | | PROVIDE STORM PANEL INFORMATION WITH INSTALLATION | | | SCHEDULE AND KEY PLAN WITH | | | SPECIFIC ANCHORS AND MOUNTING TO BE USED FOR ALL | | | NON-IMPACT GLAZING. FBC 1606.1.4. | | | | | | FL BLD CODE 2001 SECTION 103.6, 1606.1.4, 1707.4 & | | | 3401.7.2.4.PROCEDURES: 1(B) A COMPLETE INSTALLATION | | | SCHEDULE SUMMARIZING & IDENTIFYING | | | OPENING SIZES, STORY HEIGHTS, UNIT MARK NUMBERS, UNIT | | | SPANS/WIDTHS, UNIT STORM BAR REINFORCING REQUIREMENTS, | | | WALL PRESSURE ZONES, SLAT TYPES, ETC., SHALL BE | | | SUBMITTED AT TIME OF PERMIT APPLICATIONTO FACILITATE | | | PLAN REVIEW AND PERMIT ISSUANCE. | | | | | | INDICATE ON THE FLOOR PLAN THE LOCATION WHERE STORM | | | SHUTTERS WILL BE SECURED & STORED. 106.1.2* | | | | | | | | | | | | | | | 16)PRODUCT APPROVALS SUBMITTED WITH PERMIT | | | APPLICATION AFTER OCTOBER 1, 2003 ARE REQUIRED TO | | | COMPLY WITH THE FLORIDA PRODUCT APPROVAL SYSTEM. FOR | | | INFORMATION PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH STATEWIDE | | | APPROVAL ARE REQUIRED TO BE SUBMITTED WITH A COVER | | | SHEET THAT LISTS THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE STATEWIDE APPROVAL, | | | SUBMIT AN APPLICATION FOR LOCAL PRODUCT APPROVAL OR | | | SITE SPECIFIC FORM PER RULE 9B-72. | | | WWW.FLORIDABUILDING.ORG | | | | | | 17) WPB ADMIN CODE 106.3* PRODUCT APPROVALS. THOSE | | | PRODUCT WHICH ARE REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | | | | 18-19) COMPLIED. | | | | | | 20) 2ND REQUEST, FOR THE MISSION "S" ROOF TILE PLEASE | | | CIRCLE WHICH FASTENING METHOD WILL BE USED TO CHECK | | | UPLIFT FACTORS. | | | | | | 21) PLEASE PROVIDE HIP AND RIDGE ATTACHMENT FOR THE | | | MISSION "S" CONCRETE RIDGE TILE AND TYPE OF HIP OR | | | RIDGE BOARD TO BE USED AND THE TYPE OF FASTENERS FOR | | | THE HIP BOARD. 1507.3.7 ATTACHMENT. | | | CLAY AND CONCRETE ROOF TILES SHALL BE FASTENED IN | | | ACCORDANCE WITH SECTION 1609 OR IN ACCORDANCE WITH FRSA | | | /RTI INSTALLATION MANUAL. | | | 1507.3.8 APPLICATION. | | | TILE SHALL BE APPLIED ACCORDING TO THE MANUFACTURER?S | | | INSTALLATION INSTRUCTIONS OR RECOMMENDATIONS OF THE | | | FRSA /RTI 07320-05. | | | | | | 22) 2ND REQUEST PLEASE PROVIDE EFIS MOLDING SYSTEM | | | INFORMATION FOR ADHERING MOLDING TO THE WALL. 106.1.2 | | | ADDITIONAL INFORMATION REQUIRED. | | | | | | 23)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, | | | IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. THE | | | ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 24 ) 109.3.10* IMPACT OF CONSTRUCTION. ALL CONSTRUCTION | | | ACTIVITY REGULATED BY THIS CODE SHALL BE PERFORMED IN A | | | MANNER SO AS NOT TO ADVERSELY IMPACT THE CONDITION OF | | | ADJACENT PROPERTY, UNLESS SUCH ACTIVITY IS PERMITTED TO | | | AFFECT SAID PROPERTY PURSUANT TO A CONSENT BY | | | THE APPLICABLE PROPERTY OWNER, UNDER TERMS & CONDITIONS | | | AGREEABLE TO THE APPLICABLE PROPERTY OWNER. THIS | | | INCLUDESBUT IS NOT LIMITED TO THE CONTROL OF DUST, | | | NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND THE | | | STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION | | | ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE | | | WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY | | | REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE POSITIVE PATTERNS | | | OF THE AFFECTED SITES. ACCORDINGLY, DEVELOPERS, | | | CONTRACTORS, AND OWNERS OF ALL NEW RESIDENTIAL | | | DEVELOPMENT, INCLUDING ADDITIONS, POOLS, | | | PATIOS, DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ | | | FT OF PERMEABLE LAND AREA ON ANY PARCEL SHALL AS A | | | PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED | | | DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS | | | PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A | | | CERTIFICATE FROM A LICENSED ENGINEER SHALL BE SUBMITTED | | | TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL OF THE | | | FINAL INSPECTION. | | | | | | 25)109.3.10.1 HURRICANE PROTECTION. IT SHALL BE | | | UNLAWFUL FOR ANY PERSON TO ALLOW CONSTRUCTION RELATED | | | MATERIALS EQUIPMENT AND DEBRIS TO REMAIN LOOSE OR | | | OTHERWISE UNSECURED AT A CONSTRUCTION SITE FROM 24 HRS. | | | AFTER A HURRICANE WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN LIFTED. ALL SUCH | | | CONSTRUCTION MATERIALS, | | | EQUIPMENT AND DEBRIS SHALL BE EITHER REMOVED FROM THE | | | CONSTRUCTION SITE OR SECURED IN SUCH A MANNER AS TO | | | MINIMIZE THE DANGER OF SUCH CONSTRUCTION MATERIALS, | | | EQUIPMENT AND DEBRIS CAUSING DAMAGE TO PERSONS OR | | | PROPERTY FROM HIGH WINDS. ANY PERSONS WHO FAILS TO | | | COMPLY TO REMOVE OR SECURE THE CONSTRUCTION MATERIALS | | | EQUIPMENT AND DEBRIS WITHIN | | | 24 HRS AFTER A HURRICANE WATCH HAS BEEN ISSUED SHALL BE | | | SUBJECT TO A FINE NOT TO EXCEED $500.00. IN ADDITION | | | TO THE ABOVE, A LICENSED CONTRACTOR WHO VIOLATES THIS | | | SECTION | | | SHALL BE SUBJECT TO DISCIPLINE PURSUANT TO SECTION 113 | | | OF THIS CHAPTER. | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-05-08 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-05-08 |
Time |
16:20 |
Rev Time |
5.55 |
| Received By |
jwitmer |
Date |
2007-05-08 |
Time |
16:20 |
Sent To |
FIRE |
|
| Notes |
| 2007-05-08 16:55:19 | | | | | | | BUILDING PLAN REVIEW | | | PERMIT: 07030860 | | | ADD: 9835 OKEECHOBEE BLVD | | | CONT: GIL HYATT CONSTRUCTION | | | TEL: (954)772-2066 | | | | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER, | | | WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICATION | | | PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT.PLEASE REMOVE VOID | | | SHEETS FROM PLAN AND LOOSLEY LAY THEM ON TOP OF THE SET | | | OF PLANS MARKED VOID. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2 ) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF | | | THE COURT. | | | NOTE: 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT | | | IS NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE | | | RECORDING THEREOF, | | | SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)THE | | | POSTING OF THE NOTICE | | | OF COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE | | | FIRST INSPECTION. | | | | | | 3)FBC 1802.2.1 QUESTIONABLE SOILS, | | | 1802.2.1 QUESTIONABLE SOIL. WHERE THE SAFE-SUSTAINING | | | POWER OF THE SOIL | | | IS IN DOUBT, OR WHERE A LOAD-BEARING VALUE SUPERIOR TO | | | THAT SPECIFIED IN | | | THIS CODE IS CLAIMED, THE BUILDING OFFICIAL SHALL | | | REQUIRE THAT THE NECESSARY | | | INVESTIGATION BE MADE. SUCH INVESTIGATION SHALL COMPLY | | | WITH THE PROVISIONS | | | OF SECTIONS 1802.4 THROUGH 1802.6 . | | | | | | 4)PROVIDE FLOOD ZONE ELEVATION | | | CERTIFICATE FOR NEW CONSTRUTION WITH | | | BASE FLOOD ELEVATION, CITY CODE REQUIRES | | | AN ADDITIONAL 6". LOCATED IN A A-) FLOOD ZONE. | | | | | | 5) SHEET C-5INDICATES AN ASSUMED LEASE LINE, SINCE | | | LOCATED THIS WAY THIS WILL ALSO BE THE ASSUMED PROPERTY | | | LINE BETWEEN THE TWO BUILDINGS. PLEASE PROVIDE THE | | | ACTUAL DISTANCE BOTH BUILDINGS ARE LOCATED FROM THE | | | ASSUMED LEASE LINE FOR TABLE 602 & TABLE 704.8. | | | | | | 6)SHEET A1.4 NOTE# 5 REFERENCES ROOF TOP MECHANICAL | | | EQUIPMENT REQUIREMENTS THE WRONG FLORIDA CODE IS | | | REFERENCED AND TABLE OR ARTICLE NUMBER, PLEASE | | | CORRECT. | | | | | | 7) SHEET A1.4 INDICATES THE USE OF A BILCO ROOF HATCH, | | | CURRENTLY THERE IS NO PRODUCTS ON THE MARKET THAT MEET | | | THE STATE REQUIREMENTS FOR STRUCTURAL COMPONENTSAS PER | | | RULE 9B-72.010(28), FLORIDA ADMINISTRATIVE CODE AND IS | | | SUBJECT TO THE REQUIREMENTS FOR PRODUCT APPROVAL. SEE | | | ATTACHMENT. | | | | | | 8) SHEET A2.0 & A2.1THE PLAN INDICATES A DESIGN | | | OPENING PRESSURE SCHEDULE FOR OPENINGS, ALL PRESSURES | | | ARE LOW FOR POSITIVE AND NEGATIVE VALUES FOR A "B" | | | ZONE | | | | | | LOCATION. SEE TABLE 1609.6.2.1(2) SEE BLUE SHEETS OR | | | 2006 CODE REVISIONS!!! | | | | | | 9)SHEET A5.0- A5.3 ALL SHOW VARIOUS DETAILS | | | INDICATING AN ASSEMBLY TYPE 1 OR 2.SOME OF THESE | | | WALLS ARE BUILT OUT BUT THE FOUNDATIONS ARE NOT NOR IS | | | THERE AN INSPECTION AREA LEFT OPEN. | | | IN ORDER TO PROVIDE FOR INSPECTION FOR TERMITE | | | INFESTATION, CLEARANCE BETWEEN EXTERIOR WALL COVERINGS | | | AND FINAL EARTH GRADE ON THE EXTERIOR OF A BUILDING | | | SHALL NOT BE LESS THAN 6 INCHES (152 MM). EXCEPTIONS: | | | 1.PAINT OR DECORATIVE CEMENTITIOUS FINISH LESS | | | THAN 5 / 8 INCH (17.1 MM) THICK ADHERED DIRECTLY TO THE | | | MASONRY FOUNDATION SIDEWALL. | | | 2.ACCESS OR VEHICLE RAMPS WHICH RISE TO THE | | | INTERIOR FINISH FLOOR ELEVATION FOR THE WIDTH OF SUCH | | | RAMPS ONLY. | | | 3.A 4-INCH (102 MM) INSPECTION SPACE ABOVE PATIO | | | AND GARAGE SLABS AND ENTRY AREAS. | | | 4.IF THE PATIO HAS BEEN SOIL TREATED FOR TERMITES | | | , THE FINISH ELEVATION MAY MATCH THE BUILDING INTERIOR | | | FINISH FLOOR ELEVATIONS ON MASONRY CONSTRUCTION ONLY. | | | 5.MASONRY VENEERS. | | | | | | 10) SHEET A5.0 WALL ASSEMBLY# 2 ALSO INDICATES THAT | | | ALUCOBOND MAY ALSO BE USED, PLEASE PROVIDE THE PRODUCT | | | APPROVAL FOR SAID PRODUCT. THE BACKING OF SAID WALLS | | | INDICATES FOAM.2603.4.1.4 EXTERIOR WALLS?ONE-STORY | | | BUILDINGS. | | | FOR ONE-STORY BUILDINGS, FOAM PLASTIC HAVING A FLAME | | | SPREAD INDEX OF 25 OR LESS, AND A SMOKE-DEVELOPED INDEX | | | OF NOT MORE THAN 450, SHALL BE PERMITTED WITHOUT | | | THERMAL BARRIERS IN OR ON EXTERIOR WALLS IN A THICKNESS | | | NOT MORE THAN 4 INCHES (102 MM) WHERE THE FOAM PLASTIC | | | IS COVERED BY A THICKNESS OF NOT LESS THAN | | | 0.032-INCH-THICK (0.81 MM) ALUMINUM OR | | | CORROSION-RESISTANT STEEL HAVING A BASE METAL THICKNESS | | | OF 0.0160 INCH (0.41 MM) AND THE BUILDING IS EQUIPPED | | | THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN | | | ACCORDANCE WITH SECTION 903.3.1.1 . | | | | | | | | | | | | 11)NOTE: SHEET A2.0 & A2.1 BOTH INDICATE THE USE OF | | | METAL AWNINGS, PLANS INDICATE THEY ARE TO BE UNDER | | | SEPERATE PERMIT, TO BE REVIEWED UNDER A SEPERATE | | | PERMIT. | | | | | | 12) A4.1 PLANS INDICATE THERE SHALL BE INSTALLED A WALK | | | IN COOLER AND FREEZER, NO INFORMATION WAS | | | SUBMITTED.2603.4.1.3 WALK-IN COOLERS. | | | IN NONSPRINKLERED BUILDINGS, FOAM PLASTIC HAVING A | | | THICKNESS THAT DOES NOT EXCEED 4 INCHES (102 MM) AND A | | | MAXIMUM FLAME SPREAD INDEX OF 75 IS PERMITTED IN | | | WALK-IN COOLERS OR FREEZER UNITS WHERE THE AGGREGATE | | | FLOOR AREA DOES NOT EXCEED 400 SQUARE FEET (37 M 2 ) | | | AND THE FOAM PLASTIC IS COVERED BY A METAL FACING NOT | | | LESS THAN 0.032-INCH-THICK (0.81 MM) ALUMINUM OR | | | CORROSION-RESISTANT STEEL HAVING A MINIMUM BASE METAL | | | THICKNESS OF 0.016 INCH (0.41 MM). A THICKNESS OF UP TO | | | 10 INCHES (254 MM) IS PERMITTED WHERE PROTECTED BY A | | | THERMAL BARRIER. | | | | | | 13)S0.1 GOVERNING CODE NOTEA FLORIDA 2004 FBC WITH | | | 2006 REVISIONS, PLEASE CORRECT. | | | | | | 14) S0.2 WIND PRESSURES ARE LOW IN WALL ZONE (4) | | | NEGATIVE PRESSURES) SEE BLUE SHEETS 2005 REVISIONS. | | | TABLE 1609.6.2.1(2) | | | | | | 15) THE PRODUCT APPROVALS SUBMITTED ARE UNDER THE 2001 | | | FBC PLEASE PROVIDE THE APPROVALS THAT ARE CURRENTLY | | | UNDER THE 2004 FBC. FL BLD CODE 1609.1.4: COMPONENTS | | | & CLADDING, PROVIDE 2 COPIES(3 IF THRESHOLD OR RESIDENT | | | INSPECTOR) OF PRODUCT TESTING REPORTS,MISSING REPORTS | | | ARE AS FOLLOWS: | | | A) FIXED WINDOWS, STOREFRONT | | | B) MULLIONS | | | C) OPERABLE WINDOWS | | | D) GLAZED DOORS PASS THROUGHS | | | E)HOLLOW CORE METAL DOORS | | | F)BILCO ROOF HATCH SEE TECHNICAL ADVISORY FROM BCAB | | | G) TRUSS ANCHORS | | | H) STORM SHUTTERS (POSSIBLY) | | | I) ROOF ASSEMBLIES | | | J) PRE-MANUFACTURED A/C STANDS | | | K) EFIS SYSTEMS | | | | | | 16)PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 17) | | | ) WPB ADMIN CODE 106.3* PRODUCT | | | APPROVALS. THOSE PRODUCT WHICH ARE | | | REGULATED BY DCA RULE 9B-72 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | | FOR JURISDICTIONAL APPROVAL. | | | | | | 18)1707.4.5.2 MULLIONS SHALL BE DESIGN- | | | ED TO TRANSFER THE DESIGN PRESSURE LOADS | | | APPLIED BY THE WINDOW OR DOOR ASSEMBLIES | | | TO THE ROUGH OPENING SUBTRATE. | | | | | | 19)) THIS ROOF IS MISSING OR NOT IN | | | COMPLIANCE WITH THE FOLLOW ITEMS: | | | _X__ CONTRACTOR DID NOT PROVIDE THE MEAN | | | ROOF HEIGHT. | | | | | | ___ CONTRACTOR DID NOT INDICATE THE ROOF | | | PITCH. | | | | | | _X__ CONTRACTOR FAILED TO INDICATE WHICH | | | SYSTEM TO BE USED. | | | | | | _X__ THE SYSTEM PROVIDED HAS A LOW | | | PRESSURE FOR ZONE 2& 3___ . | | | | | | _X__ THE SYSTEM PROVIDED STATES | | | LIMITATION# 7, SHOULD THE FASTENER | | | RESISTANCE BE LESS THAN THAT | | | REQUIRED, AS DETERMINED BY THE | | | BUILDING OFFICIAL, A REVISED | | | FASTENER SPACING, PLEASE PROVIDE | | | THE RAS 117 CALCULATION. | | | | | | _X__THE SYSTEM PROVIDED INDICATES | | | LIMITATION# 9, NO ENHANCED | | | FASTENING ALLOWED. | | | | | | 20)FOR THE MISSION "S" ROOF TILE PLEASE CIRCLE WHICH | | | FASTENING METHOD WILL BE USED | | | TO CHECK UPLIFT FACTORS. | | | | | | 21) PLEASE PROVIDE HIP AND RIDGE ATTACHMENT FOR THE | | | MISSION "S" CONCRETE RIDGE TILE AND TYPE OF HIP OR | | | RIDGE BOARD TO BE USED AND THE TYPE OF FASTENERS FOR | | | THE HIP BOAAD. 1507.3.7 ATTACHMENT. | | | CLAY AND CONCRETE ROOF TILES SHALL BE FASTENED IN | | | ACCORDANCE WITH SECTION 1609 OR IN ACCORDANCE WITH FRSA | | | /RTI INSTALLATION MANUAL. | | | 1507.3.8 APPLICATION. | | | TILE SHALL BE APPLIED ACCORDING TO THE MANUFACTURER?S | | | INSTALLATION INSTRUCTIONS OR RECOMMENDATIONS OF THE | | | FRSA /RTI 07320-05. | | | | | | 22)PLEASE PROVIDE EFIS MOLDING SYSTEM INFORMATION FOR | | | ADHERRING MOLDING TO THE WALL. 106.1.2 ADDITIONAL | | | INFORMATION REQUIRED. | | | | | | 23)BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 24 ) 109.3.10* IMPACT OF CONSTRUCTION. | | | ALL CONSTRUCTION ACTIVITY REGULATED BY | | | THIS CODE SHALL BE PERMORMED IN A MANNER | | | SO AS NOT TO ADVERSELY IMPACT THE | | | CONDITION OF ADJACENT PROPERTY, UNLESS | | | SUCH ACTIVITY IS PERMITTED TO AFFECT | | | SAID PROPERTY PURSUANT TO A CONSENT BY | | | THE APPLICABLE PROPERTY OWNER, UNDER | | | TERMS & CONDITIONS AGREEABLE TO THE | | | APPLICABLE PROPERTY OWNER.THIS INCLUDES | | | BUT IS NOT LIMITED TO THE CONTROL OF | | | DUST, NOISE, WATER OR DRAINAGE RUN-OFF, | | | DEBRIS, AND THE STORAGE OF CONSTRUCTION | | | MATERIALS. NEW CONSTRUCTION ACTIVITY | | | SHALL NOT ADVERSELY IMPACT HISTORIC | | | SURFACE WATER DRAINAGE FLOWS SERVING | | | ADJACENT PROPERTIES, & MAY REQUIRE | | | SPECIAL DRAINAGE DESIGN COMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE | | | POSITIVE PATTERNS OF THE AFFECTED SITES. ACCORDINGLY, | | | DEVELOPERS, CONTRACTORS, | | | AND OWNERS OF ALL NEW RESIDENTIAL | | | DEVELOPMENT, INCLUDING ADDITIONS, POOLS, | | | PATIOS, DRIVEWAYS, DECKS, OR SIMILAR | | | ITEMS, ON EXISTING PROPERTIES RESULTING | | | IN A DECREASE IN EXCESS OF 800SQ FT OF | | | PERMEABLE LAND AREA ON ANY PARCELL SHALL | | | AS A PERMIT CONDITION, PROVIDE A | | | PROFESSIONALLY PREPARED DRAINAGE PLAN | | | CLEARLY INDICATING COMPLIANCE WITH THIS | | | PARAGRAPH. UPON COMPLETION OF THE | | | IMPROVEMENT, A CERTIFICATE FROM A | | | LICENSED ENGINEER SHALL BE SUBMITTED TO | | | THE INSPECTOR IN ORDER TO RECEIVE | | | APPROVAL OF THE FINAL INSPECTION. | | | | | | 25)109.3.10.1 HURICANE PROTECTION. | | | IT SHALL BE UNLAWFUL FOR ANY PERSON TO | | | ALLOW CONSTRUCTION RELATED MATERIALS | | | EQUIPMENT AND DEBRIS TO REMAIN LOOSE OR | | | OTHERWISE UNSECURED AT A CONSTRUCTION | | | SITE FROM 24 HRS. AFTER A HURRICANE | | | WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN | | | LIFTED. ALL SUCH CONSTRUCTION MATERIALS, | | | EQUIPMENT AND DEBRIS SHALL BE EITHER | | | REMOVED FROM THE CONSTRUCTION SITE OR | | | SECURED IN SUCH A MANNER AS TO MINIMIZE | | | THE DANGER OF SUCH CONSTRUCTION | | | MATERIALS, EQUIPMENT AND DEBRIS CAUSING | | | DAMAGE TO PERSONS OR PROPERTY FROM HIGH | | | WINDS. | | | ANY PERSONS WHO FAILS TO COMPLY TO | | | REMOVE OR SECURE THE CONSTRUCTION | | | MATERIALS EQUIPMENT AND DEBRIS WITHIN | | | 24 HRS AFTER A HURRICANE WATCH HAS BEEN | | | ISSUED SHALL BE SUBJECT TO A FINE NOT TO | | | EXCEED $500.00. | | | IN ADDITION TO THE ABOVE, A LICENSED | | | CONTRACTOR WHO VIOLATES THIS SECTION | | | SHALL BE SUBJECT TO DISCIPLINE PURSUANT | | | TO SECTION 113 OF THIS CHAPTER. | | | | | | A THOROUGH REVIEW CAN NOT BE MADE AT THIS TIME, AS A | | | RESULT OF THE ADDITIONAL INFORMATION REQUESTED | | | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF | | | THIS REVIEW. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-10-26 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-10-26 |
Time |
12:14 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-10-26 |
Time |
12:14 |
Sent To |
|
|
| Notes |
| 2007-10-26 12:17:13 | REV FOR ELEC E1, E-2, E-3, E-7 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-09-18 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-09-18 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-09-18 |
Time |
14:44 |
Sent To |
I |
|
| Notes |
| 2007-09-18 14:46:30 | ***PLANS WERE REMOVED FROM INCOMING DUE TO THE DATED | | | ORDER IN WHICH ELECTRICAL REVIEW IS UP TO. | | | **PLANS WERE ROUTED BACK TO INCOMING/TABLE WAITING FOR | | | COMM BOARD SPACE. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-07-04 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-07-04 |
Time |
12:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-07-04 |
Time |
10:43 |
Sent To |
I |
|
| Notes |
| 2007-07-04 12:32:03 | 2007-07-04 12:32:03 | | | ** UNSAT 2ND REVIEW ** | | | | | | ** PLEASE SEE SOME COMMENTS FROM PREVIOUS REVIEW ARE | | | STILL IN NEED OF ADDRESSING. | | | | | | | | | PROPOSED MCDONALDS | | | 9835 OKEECHOBEE BLVD. | | | | | | 1) NOTE: PLEASE SEE THE RESPONSE LETTER FROM THE | | | ENGINEER DOES NOT CORRELATE WITH THE REVIEW NOTES AS | | | PREVIOUSLY GIVEN AND THEREFORE SOME OF THE RESPONSES | | | AND NOTES DO NOT COORDINATE WITH THE ACTUAL NOTES | | | PREVIOUSLY TYPED AND GIVEN BY THIS REVIEWER. PLEASE SEE | | | FOR EXAMPLE, NOTE #5, NOTE #6, NOTE #7 ETC. | | | | | | 2) NOTE: 2ND TIME NOTED. | | | PLEASE SEE THE ENERGY CALCULATIONS AS SUBMITTED DO NOT | | | CORRELATE WITH PLANS. | | | PLEASE SEE THE ADDRESS AS LISTED ON ALL SHEETS OF THE | | | ENERGY CALCULATIONS INCLUDING SUMMARY SHEETS INDICATES | | | 2721 OKEECHOBEE BLVD WHICH IS NOT THE ADDRESS OF THE | | | BUILDING BEING PROPOSED. | | | PLEASE SEE THE SUMMARY SHEETS FOR EXTERIOR LIGHTING | | | WHICH INDICATES A TOTAL OF 0 FOR DESIGN WATTAGE AND 0 | | | FOR ALLOWANCE?HOW IS THIS POSSIBLE WHEN THERE ARE | | | FIXTURES IN DESIGN OF PROJECT? | | | PLEASE SEE THE INPUT DATA REPORT WHICH DOES NOT | | | COORDINATE WITH THE LIGHTING AS SHOWN ON PLANS. PLEASE | | | SEE THE EXTERIOR LIGHTING INPUT DATA, AS THE NUMBER OF | | | FIXTURES, THE WATTAGE AND THE TYPES DO NOT CORRELATE | | | WITH PLANS. | | | PLEASE SEE THE INPUT DATA REPORT FOR INTERIOR LIGHTING | | | AS THIS ALSO NEEDS TO CORRELATE WITH THE PLANS AND | | | FIXTURE LEGEND AS SUBMITTED. PLEASE COORDINATE THE | | | TYPES OF LUMINARIES, THE NUMBER OF LUMINARIES UNDER | | | EACH AND THE WATTAGE OF EACH WITH THE FIXTURE LEGEND | | | AND PLANS. | | | ** PLEASE BE SURE THE CERTIFICATION SHEET IS SIGNED, | | | DATED AND SEALED AS REQUIRED. | | | PLEASE SEE 13-415.1.A | | | 13-103.1.1.1 | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE 2004 FBC W/ 2006 REVISION FOR CHAPTER 13. | | | PLEASE SEE 13-415.1.AB.1.1, 13-415.2 AS THE ENERGY | | | CALCULATIONS DO NOT COORDINATE WITH THE ELECTRICAL | | | PLANS FOR THE FIXTURES, AMOUNT OF FIXTURES, ETC. PLEASE | | | SEE PLANS INDICATE OVER 100PLUS FIXTURES, AND | | | CALCULATIONS ONLY INDICATE 30? | | | PLEASE SEE NO INFORMATION ENTERED FOR EXTERIOR | | | LIGHTING, YET PLANS INDICATE NUMEROUS EXTERIOR LIGHTS? | | | PLEASE SEE THE WATTAGE AND FIXTURES DO NOT CORRELATE. | | | ** THERE ARE SEVERAL ITEMS NOT LISTED AND A COMPLETE | | | REVIEW FOR CODE COMPLIANCE CAN NOT BE DONE AT THIS | | | TIME. | | | | | | 3) NOTE: CHECK ALL EQUIPMENT AND OVER CURRENT | | | PROTECTION AS NOTED ON EQUIPMENT SCHEDULE WITH THAT OF | | | THE OVER CURRENT PROTECTION ON PANEL SCHEDULES. PLEASE | | | ALSO CHECK FOR GFI PROTECTION. | | | EXAMPLE: PLEASE SEE CIRCUITS AP1 9 AND 11, INDICATES | | | 20AMP, YET EQUIPMENT SCHEDULE SHOWS 15AMP. | | | PLEASE BE SURE TO INDICATE 210.8B2 | | | | | | ** PREVIOUS REVIEW NOTE** | | | PLEASE SEE 2005 NEC 210.8B2 FOR ALL 15/20AMP, 120V | | | RECEPTACLES IN KITCHEN/FOOD PREPARATION AREAS TO BE | | | GFI/GFI PROTECTED. | | | PLEASE SEE THE SECTION OF CODE NOTED ON PLANS IS NOT | | | COMPLETE WITH THE SECTION AS NOTED. | | | PLEASE ALSO SEE THAT NOT ALL CIRCUITS AS REQUIRED | | | INDICATE THE PROTECTION. | | | PLEASE SEE SOME CIRCUITS INDICATE PROTECTION WHERE NOT | | | REQUIRED? | | | PLEASE COORDINATE. | | | | | | 4) NOTE:THIS COMMENT REMAINS AS NO CHANGES WERE MADE | | | TO PERMIT APPLICATION OR SCOPE. NO RESPONSE WAS MADE?? | | | PLEASE SEE THE VALUE FOR COMPLETE SCOPE OF WORK APPLIED | | | FOR SHALL INCLUDE ALL LABOR, MATERIALS, PERMANENTLY | | | INSTALLED EQUIPMENT, DESIGN COST ETC EVEN IF ANY OF | | | THESE ITEMS ARE OWNER SUPPLIED. FBC ADMIN SECTION | | | 108.3 | | | | | | ** PREVIOUS REVIEW NOTE**PLEASE SEE THE VALUE FOR THE | | | COMPLETE SCOPE OF WORK FOR THIS NEW BUILDING SHALL | | | INCLUDE ALL LABOR AND MATERIALS. PLEASE KNOW THAT EVEN | | | EQUIPMENT SUCH AS KITCHEN, A/C ETC WHICH MAY BE OWNER | | | SUPPLIED IS TO BE INCLUDED IN VALUE. | | | FBC 108.3. | | | | | | 5) NOTE: PLEASE SEE PREVIOUS NOTE #7. THE EXCEPTION IN | | | THE NEC UNDER 700.12F FOR ALLOWANCE OF CIRCUITING AS | | | SHOWN MENTIONS 3 OR MORE CIRCUITS IN ANY SEPARATE AND | | | UN-INTERRUPTED LOCATION. PLEASE SEE THE RESPONSE | | | MENTIONS COMMENTS WITH RESPECT TO THE *INTENT* OF THE | | | CODE WHICH IS UNDERSTOOD HOWEVER THE NUMBER OF CIRCUITS | | | AND THE UN-INTERRUPTED SPACES IS NOT PRESENT ON PLANS | | | IN SOME OF THESE AREAS. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE COMPLETE CIRCUITING ON PLANS FOR ALL EMERGENCY | | | LIGHTS AND EXIT LIGHTS. | | | PLEASE SEE 700.12F AS THE EM/EXT LIGHTS SHALL BE | | | CIRCUITED TO THE LOCAL LIGHTING IN ANY ONE AREA. PLEASE | | | COMPLETE ON PLANS. | | | THE NOTE ON E-3 FOR EMERGENCY NOTES #1 DOES NOT MEET | | | THE CODE AND SECTION AS NOTED. | | | PLEASE ADJUST PLANS AND NOTES. | | | | | | 6) NOTE: PLEASE SEE PREVIOUS NOTE #8 WHICH REQUESTED | | | ADJUSTMENT FOR WATER HEATER. PLEASE SEE THE RESPONSE | | | MENTIONS THE BRANCH CIRCUIT IS SIZED FOR 125% (TYPED AS | | | 12% IN RESPONSE)(MISPRINT). PLEASE SEE THE NEC CHANGED | | | AND THIS INCLUDE THE LOADS IN LOAD CALCULATIONS TO ALSO | | | BE SHOWN AND FIGURED AT 125%. THE WATER HEATER LOAD IS | | | SHOWN AS 18KW, (ENERGY CALCULATIONS DOES NOT CORRELATE) | | | AND THE LOAD SUMMARY DOES NOT INDICATE IF THIS IS THE | | | 125%. PLEASE SEE FOLLOWING TEXT WHICH HAS BEEN | | | EXTRACTED FROM THE NEC COMMENTARY. | | | **THE REVISION TO 422.13 SPECIFICALLY IDENTIFIES AN | | | ELECTRIC WATER HEATER WITH A STORAGE CAPACITY OF 120 | | | GAL OR LESS AS A CONTINUOUS LOAD. THIS REVISION | | | REQUIRES THE BRANCH CIRCUIT OVERCURRENT DEVICE AND | | | CONDUCTORS TO BE SIZED BASED ON 125 PERCENT OF THE | | | WATER HEATER NAMEPLATE RATING UNLESS THE OVERCURRENT | | | DEVICE AND THE ASSEMBLY IT IS INSTALLED IN ARE LISTED | | | TO BE USED AT 100 PERCENT OF ITS CONTINUOUS CURRENT | | | RATING. IN ADDITION, FEEDERS AND SERVICES THAT SUPPLY | | | WATER HEATER BRANCH CIRCUITS ARE ALSO IMPACTED BY THE | | | FACT THAT THIS TYPE OF EQUIPMENT IS CONSIDERED TO BE A | | | CONTINUOUS LOAD.** | | | | | | PLEASE 422.13 AS THE CHANGES IN THE 2005 NEC REQUIRES | | | THE WATER HEATER LOAD TO BE FIGURED IN THE CALCULATIONS | | | AT 125%. | | | PLEASE ADJUST CALCULATIONS. | | | | | | 7) NOTE:THIS NOTE REMAINS AS LOADS AND INFORMATION | | | FOR NOTES ABOVE WILL NEED TO BE ADJUSTED. | | | PLEASE SEE NO LOAD SUMMARY WAS SUBMITTED INDICATING HOW | | | LOADS WERE DERIVED. | | | EX: 12 RECEPTS AT 180VA ETC | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE PROVIDE MORE DETAIL ON THE LOAD SUMMARY FOR THE | | | LOAD CALCULATIONS. | | | PLEASE SEE NOTE ABOVE AS THIS WILL ALSO AFFECT THE | | | LOAD. | | | PLEASE KNOW AT THIS TIME THE LOADS ARE NOT CLEAR AS NOT | | | ALL LOADS ARE FIGURED IN WITH KITCHEN EQUIPMENT AND NOT | | | SURE WHERE AND HOW THE OTHER LOADS ARE BEING DONE OR | | | FIGURED. | | | FBC 106.1.3.5.1.2, 106.1.2. NEC 220. | | | | | | 8) NOTE:SAME NOTE AS NOTE #10 ON PREVIOUS REVIEW. NO | | | RESPONSE TO THIS NOTE OR CHANGES TO NOTES ON | | | PLANS/PANEL SCHEDULES. | | | | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE KNOW THAT ANY LOCK ON/OFF DEVICES WILL BE | | | REQUIRED TO HAVE THE DEVICE BE AN INTEGRAL PART OF THE | | | BREAKER. THE DEVICES WHICH *SNAP/CLIP* ON TO BREAKERS | | | AND ARE READILY REMOVED OR FALL OF WHEN PANEL COVERS | | | ARE REMOVED ARE NOT APPROVED BY THIS AHJ. PLEASE ADJUST | | | NOTE TO STATE *THE DEVICE SHALL BE AN INTEGRAL PART OF | | | THE BREAKER* OR WORDS TO THAT AFFECT. 110.3, 90.4. | | | | | | 9) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO | | | REPEAT COMMENTS. THIS IS ONLY A NOTICE GIVEN AT THIS | | | TIME. | | | ONE SET OF ELECTRICAL PLANS AND ENERGY CALCULATIONS ARE | | | BEING RETAINED. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | ** PLEASE BE SURE TO SEE ANY COMMENTS FROM OTHER TRADES | | | WHICH MAY AFFECT ELECTRICAL PLANS AND DESIGN CHANGES. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-07-04 10:44:44 | 2007-07-04 10:44:44 | | | PLANS REMOVED FROM INCOMING. PLANS WILL BE RETURNED TO | | | INCOMING WAITING FOR COMM BOARD ONCE ELECTRICLA REVIEW | | | IS COMPLETED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-04-03 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-04-03 |
Time |
10:31 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-04-02 |
Time |
14:58 |
Sent To |
|
|
| Notes |
| 2007-04-03 10:32:24 | ** UNSAT** | | | | | | PROPOSED MCDONALDS | | | 9835 OKEECHOBEE BLVD. | | | | | | 1) NOTE: PLEASE BE SURE ONCE THE ADDRESSED IS VERIFIED | | | THAT THE TITLE BLOCKS ON PLANS ARE CORRECTED TO INCLUDE | | | THE ADDRESS LOCATION. AT THIS TIME THE ADDRESS IN OUR | | | SYSTEM IS BEING SHOWN AS 9835 OKEECHOBEE. ONE ANY SHEET | | | OF PLANS WHICH DOES NOT HAVE TO HAVE CORRECTIONS MADE, | | | THEN THE ADDRESS CAN BE ADDED TO THE EXISTING SHEET. | | | THIS WOULD ONLY BE FOR ANY SHEETS WHICH DO NOT NEED TO | | | BE CHANGED OR CORRECTED. | | | 61G1-16.004, 61G15-23.002 | | | | | | 2) NOTE: PLEASE SEE THAT AS OF DECEMBER 8TH, 2006 THE | | | STATE OF FLORIDA ADOPTED NEW CODES AS FOLLOWS. 2004 FBC | | | W/2006 REVISIONS. | | | 2005 NFPA-70 | | | OTHER CODES RELEVANT AND TO BE PLACED ON PLANS. 2003 | | | NFPA-101 | | | 2002 NFPA-72 | | | | | | ** PLEASE SEE PLANS AS THERE ARE LOCATIONS WHICH LIST A | | | 2004 ELECTRICAL CODE. | | | PLEASE SEE NUMEROUS LOCATIONS ON PLANS WHICH INDICATE | | | THE 2002 NEC/NFPA-70. | | | PLEASE SEE SEVERAL CODE SECTIONS AS REFLECTED ON PLANS | | | FOR ARTICLES FROM THE 2002 NEC, WHERE THE CODE SECTIONS | | | HAVE CHANGED IN THE 2005 NEC. | | | *EXAMPLE, SEE LOAD CALCULATIONS, GROUNDING DETAILS, | | | ETC. | | | | | | 3) NOTE: PLEASE SEE THE CERTIFICATE OF AUTHORIZATION | | | NUMBER FOR ENGINEERING FIRM *DIAMONDBACK ENGINEERING* | | | IS CURRENTLY DELINQUENT WITH THE STATE OF FLORIDA. THIS | | | HAS BEEN PRINTED AND IS ATTACHED TO NOTES AS OF | | | 4/2/07. | | | PLEASE KNOW THIS IS ALSO KNOWN AS THE EB/ ENGINEERING | | | BUSINESS LICENSE NUMBER. | | | FS 471.023, FAC 61G15-23.002 | | | | | | 4) NOTE: PLEASE SEE 2004 FBC W/ 2006 REVISION FOR | | | CHAPTER 13. PLEASE SEE 13-415.1.AB.1.1, 13-415.2 AS THE | | | ENERGY CALCULATIONS DO NOT COORDINATE WITH THE | | | ELECTRICAL PLANS FOR THE FIXTURES, AMOUNT OF FIXTURES, | | | ETC. | | | PLEASE SEE PLANS INDICATE OVER 100PLUS FIXTURES, AND | | | CALCULATIONS ONLY INDICATE 30? | | | PLEASE SEE NO INFORMATION ENTERED FOR EXTERIOR | | | LIGHTING, YET PLANS INDICATE NUMEROUS EXTERIOR LIGHTS? | | | PLEASE SEE THE WATTAGE AND FIXTURES DO NOT CORRELATE. | | | ** THERE ARE SEVERAL ITEMS NOT LISTED AND A COMPLETE | | | REVIEW FOR CODE COMPLIANCE CAN NOT BE DONE AT THIS | | | TIME. | | | | | | 5) NOTE: PLEASE SEE 2005 NEC 210.8B3 FOR ALL 15/20AMP, | | | 120V RECEPTACLES IN KITCHEN/FOOD PREPARATION AREAS TO | | | BE GFI/GFI PROTECTED. | | | PLEASE SEE THE SECTION OF CODE NOTED ON PLANS IS NOT | | | COMPLETE WITH THE SECTION AS NOTED. | | | PLEASE ALSO SEE THAT NOT ALL CIRCUITS AS REQUIRED | | | INDICATE THE PROTECTION. | | | PLEASE SEE SOME CIRCUITS INDICATE PROTECTION WHERE NOT | | | REQUIRED? | | | PLEASE COORDINATE. | | | | | | 6) NOTE: PLEASE SEE THE VALUE FOR THE COMPLETE SCOPE OF | | | WORK FOR THIS NEW BUILDING SHALL INCLUDE ALL LABOR AND | | | MATERIALS. PLEASE KNOW THAT EVEN EQUIPMENT SUCH AS | | | KITCHEN, A/C ETC WHICH MAY BE OWNER SUPPLIED IS TO BE | | | INCLUDED IN VALUE. | | | FBC 108.3. | | | | | | 7) NOTE: PLEASE COMPLETE CIRCUITING ON PLANS FOR ALL | | | EMERGENCY LIGHTS AND EXIT LIGHTS. | | | PLEASE SEE 700.12E AS THE EM/EXT LIGHTS SHALL BE | | | CIRCUITED TO THE LOCAL LIGHTING IN ANY ONE AREA. PLEASE | | | COMPLETE ON PLANS. | | | THE NOTE ON E-3 FOR EMERGENCY NOTES #1 DOES NOT MEET | | | THE CODE AND SECTION AS NOTED. | | | PLEASE ADJUST PLANS AND NOTES. | | | | | | 8) NOTE: PLEASE 422.13 AS THE CHANGES IN THE 2005 NEC | | | REQUIRES THE WATER HEATER LOAD TO BE FIGURED IN THE | | | CALCULATIONS AT 125%. | | | PLEASE ADJUST CALCULATIONS. | | | | | | 9) NOTE: PLEASE PROVIDE MORE DETAIL ON THE LOAD SUMMARY | | | FOR THE LOAD CALCULATIONS. | | | PLEASE SEE NOTE ABOVE AS THIS WILL ALSO AFFECT THE | | | LOAD. | | | PLEASE KNOW AT THIS TIME THE LOADS ARE NOT CLEAR AS NOT | | | ALL LOADS ARE FIGURED IN WITH KITCHEN EQUIPMENT AND NOT | | | SURE WHERE AND HOW THE OTHER LOADS ARE BEING DONE OR | | | FIGURED. | | | FBC 106.1.3.5.1.2, 106.1.2. NEC 220. | | | | | | 10) NOTE: PLEASE KNOW THAT ANY LOCK ON/OFF DEVICES WILL | | | BE REQUIRED TO HAVE THE DEVICE BE AN INTEGRAL PART OF | | | THE BREAKER. THE DEVICES WHICH *SNAP/CLIP* ON TO | | | BREAKERS AND ARE READILY REMOVED OR FALL OF WHEN PANEL | | | COVERS ARE REMOVED ARE NOT APPROVED BY THIS AHJ. PLEASE | | | ADJUST NOTE TO STATE *THE DEVICE SHALL BE AN INTEGRAL | | | PART OF THE BREAKER* OR WORDS TO THAT AFFECT. 110.3, | | | 90.4. | | | | | | 11) NOTE: PLEASE CLARIFY THE PHASING AS SHOWN ON PANEL | | | SCHEDULES. SOME SHOW A AND C PHASE ONLY YET PANEL IS A | | | THREE PHASE PANEL? SOME ONLY SHOW A AND C PHASES WITH A | | | BLANK FOR B PHASEYET CIRCUITS ARE SHOWN ON THIS | | | PHASE? | | | PLEASE CLARIFY THE PANELS. | | | FBC 106.1.2, 106.3.5.1.2 | | | | | | 12) NOTE: PLEASE SEE THE ADA STALLS WILL BE REQUIRED TO | | | CONTAIN A BATTERY BACK UP FIXTURE OF SOME TYPE IF WALLS | | | ARE ALL THE WAY UP TO THE CEILING. | | | PLEASE SEE LS 101 7.8, 7.9. | | | | | | | | | *** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
5 |
Status |
P |
Date |
2007-11-16 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-11-16 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-11-16 |
Time |
11:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
P |
Date |
2007-09-26 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-09-26 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-09-26 |
Time |
13:03 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
F |
Date |
2007-09-21 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-09-21 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-09-21 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2007-09-21 11:11:08 | ***FAILED**** PLEASE PROVIDE THE FOLLOWING: | | | | | | 1.YOUR SFWMD ENVIRONMENTAL RESOURCE PERMIT | | | MODIFICATION NO. 50-03926-PWAS ISSUED IN SEPT 10, | | | 1998.ON FRONT PAGE, IN PERIOD DURATION IT SAYS THAT | | | MAXIMUM TIME LIMIT IS 5 YEARS FROM ISSUE.THIS YEAR | | | ISSEPT2007. THIS IS EXPIRED PERMIT. | | | | | | 2. PLEASE SHOW IN YOUR WATER QUALITY CALS WHAT CRITERIA | | | DID YOU USE SPECIFICALLY 1" OVER ENTIRE SITE OR2.5" % | | | OF IMPERVIOUS AREA CRITERIA??YOUR CALCULATION DO NOT | | | SHOW THESE CRITERIA.PLEASE SHOW ON DRAWINGTHIS SITE | | | AREA, YOU ARE DEVELOPING FORTHIS PROJECT . | | | PLEASE ALSO SHOW TOTAL PERVIOUS,& IMPERVIOUS AREA FOR | | | THIS PROJECT, LAKE, GREEN, SIDEWALK, PARKING, BUILDING | | | AREA ETC. MAKE SURE THESE AREAS SHOWN ON DRAWINGS MUST | | | MATCH WITH AND USED IN STORM WATER QUALITY | | | CALCULATIONS. | | | | | | 3. PLEASE SHOW IN YOUR CALS, HOW DID YOU DETERMINE THE | | | FIRST FLOOR ELEVATION?MAKE SURE YOU MEETYOUR FLOOD | | | ZONE AREA, & 5,10, 25, 100 YEAR FLOOD CRITERIATO | | | DETERMINE THE FIRST FLOOR ELEVATION, CENTER LINE OF THE | | | ROAD(CROWN OF THE ROAD),PLEASE SHOWALL OF THESE IN | | | YOUR WATER QUALITY CALCULATIONS. | | | | | | 4. PLEASE SHOW DETAIL OF THE CONTROL STRUCTURESWITH | | | ELEVATIONS, NOTCHES, BLEEDING ELEVATION, ETC ON | | | DRAWINGS, CALCULATION FOR EXFILTRATION TRENCHES, PLEASE | | | SHOW DRY DETENTION/WET DETENTION SITE AREAS IN STORM | | | WATER CALS. | | | | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2007-07-23 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-07-23 |
Time |
15:45 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-07-23 |
Time |
15:34 |
Sent To |
|
|
| Notes |
| 2007-07-23 15:44:59 | ***FAILED**** PLEASE PROVIDE THE FOLLOWING: | | | | | | 1. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI). | | | PLEASE APPLY AT FDEP, NPDES STORMWATER SECTION FOR | | | NOI. | | | YOU CAN GET NOI INFO FROM | | | WWW.DEP.STATE.FL.US/WATER/STORMWATER/NPDES/ | | | NOTICE OF INTENT DEP FORM 62-621.300(4)(B), | | | EFFECTIVE MAY 1, 2003 | | | 2. FIRST FLOOR ELEVATION, CENTER LINE OF ROAD , | | | SIDEWALK ELEVATION MUST MEET FLOOD ZONE AREA, & 5,10, | | | 25, 100 YEAR FLOOD CRITERIATO DETERMINE THE FIRST | | | FLOOR ELEVATION, MUST MEET THESE MINIMUM REQUIREMENTS. | | | PLEASE SHOW IN YOUR STORM WATER CALS. PLEASE PROVODE A | | | COPY OFSTORM WATER QUALITY CALCULATIONS. | | | 3. MAKE SURE THESE SITE AREAS SHOWN ON DRAWINGS MUST | | | MATCH WITH AREAS USED IN STORM WATER QUALITY | | | CALCULATIONS. | | | 4. PLEASE SHOW ON YOUR DRAWINGS ALL STORM WATER PIPES | | | AROUND YOUR SITE SO, WE CANSEE THE LAYOUT OF STORM | | | WATER PIPES.PLEASE SHOW DETAIL OF THE CONTROL | | | STRUCTURESWITH ELEVATIONS, NOTCHES, BLEEDING | | | ELEVATION, ETC ON DRAWINGS, POND ETC | | | 5. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST AROUND | | | YOUR SITE EVENTHOUGH THEY ARE NOT IN YOUR SITE. | | | 6.WE DID NOT FIND A COPIES OF SFWMD PERMIT & A GEO-TECH | | | REPORT COPY IN YOUR PACKAGE.PLEASE PROVIDE A COPY OF | | | SFWMD PERMIT,, A COPY OF GEO-TECH REPORT AND A | | | LATESTEST COPY OF STORM STORM WATER QUALITY | | | CALCULATIONS. | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2007-04-26 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-04-26 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-04-26 |
Time |
13:57 |
Sent To |
|
|
| Notes |
| 2007-04-26 14:19:23 | PLEASE PROVIDE FOLLOWING INFO: | | | | | | 1. PLEASE SHOW STANDARDS NOTES OF CITY OF WPB ON | | | DRAWINGSFOR SIDEWALK WIDTH , ITS SLOPE, DRIVEWAY, | | | PARKING, HANDICAP PARKING, PAINTING DETAILS FOR PARKING | | | PER CITY CODES ETC.,, MUST MEET PER ADA,,ETC.,YOU CAN | | | GET STANDARD NOTES OF CITY OFWPB IN A C.D. FROM 1000 | | | 45TH STREET. ENG DEPT.WE SHOULD HAVE THOSE NOTES ON | | | YOUR DRAWINGS. | | | 2. PLEASE SHOW ON DRAWINGSDUMPSTER & ITS ENCLOSURE | | | DETAILS PER CITY OF WPB, &LOCATION ON DWG, LOCATION | | | MUST BE ACCESSIBLE FOR PICKUP TRUCK. | | | 3. FIRST FLOOR ELEVATION, CENTER LINE OF ROAD , | | | SIDEWALK ELEVATION MUST MEET FLOOD ZONE AREA, 10, 25, | | | 100 YEAR FLOOD CRITERIA &FL BUILDING CODE, FIRST | | | FLOOR ELEVATION MUST MEET THESE MINIMUM REQUIREMENTS. | | | 4. PLEASE PROVIDE A COPY OF SFWMD PERMIT,, GEO-TECH | | | REPORT AND SHOW CALCULATION FOR LENGTH OF EXFILTRATION | | | TRENCH, & SAFETY FACTOR YOU USED IN CALCULATION OF | | | EXFILTRATION LENGTH. | | | 5.PLEASE SHOW STORM WATER QUALITY CALCULATIONS, WHAT | | | CRITERIA YOU ASSUMEDFOR RUNOFF CAL.,, LIKE 1" OVER | | | ENTIRE SITE OR2.5"CRITERIA, ETC? | | | 6. WHAT IS THE SITE AREA, YOU ARE DEVELOPING FOR THIS | | | PROJECT ONLY ?ALSO, WHAT IS TOTAL PERVIOUS,& IMPERVIOUS | | | AREA FOR THIS PROJECT. | | | 7. HOW YOU CONNECT TO THE STORM WATER PIPES IN YOUR | | | SITE? ITS DETAILS.PLEASE SHOW ALL STORM WATER PIPES | | | AROUND YOUR SITE SO, WE CANSEE THE BEST PIPE TO | | | CONNECT WITH THE STORM WATERFROM ALL OTHER STORM | | | WATER PIPES. PLEASE SHOW DETAIL OF THE CONTROL | | | STRUCTURES WITH ELEVATIONS, NOTCHES, BLEEDING | | | ELEVATION, ETC DID YOU USE EXFILTRATION TRENCH ? | | | 8. POLLUTION PREVENTION DETAILS,CLOTHES USED FOR SILT | | | ETC., PLANS SHOWING SILT FENCE AROUND THE SITE & CATCH | | | BASINS.HEIGHT OF FENCE SHOULD BE HIGH ENOUGH PER FDEP | | | TO STOP DUST & PARTICLES. | | | 9. WATER & SEWER PLANS MUST BE APPROVED FROM 45TH | | | STREET (MANNY G.), UTILITY DEPT BEFORE WE APPROVED | | | 10. ALSO PLEASE SHOW ALL CATCH BASINS NEAREST,AROUND | | | YOUR SITE FOR STORM WATER DRAIN. | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2007-10-31 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-10-31 |
Time |
15:46 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-10-31 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2007-10-31 15:46:19 | *****APPROVED REVISION OF 09/14/07***** | | | | | | REVIEWED REVISED SET OF PLAN SHEETS;AFFECTED REVISED | | | PLAN SHEET E3 STAMPED, INITIALED, AND DATED. | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2007-09-19 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-09-19 |
Time |
18:51 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-09-19 |
Time |
18:18 |
Sent To |
|
|
| Notes |
| 2007-09-19 18:37:35 | *****APPROVED***** | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEW HAVE | | | BEEN ADDRESSED;PLAN SHEETS C-7, A2.0, AND E3 WERE | | | STAMPED, INITIALED, AND DATED. | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2007-07-26 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-07-26 |
Time |
15:28 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-07-26 |
Time |
14:47 |
Sent To |
|
|
| Notes |
| 2007-07-26 15:27:08 | *****DENIED***** | | | | | | THE FOLLOWIING COMMENTS TAKEN FROM THE PREVIOUS FIRE | | | PLAN REVIEW STILL NEED TO BE ADDRESSED: | | | | | | 01.THE ACTUAL NUMERICAL ADDRESS OF THE PROJECT SITE | | | SHALL BE IN TITLE BLOCK OF EACH SUBMITTED PLAN SHEET. | | | NO ADDRESS SHOWN SHEET L-1, IR-1, IR-2, C-1, 1, 2, | | | K1.0 | | | | | | 04.PLEASE SHOW LOCATION OF THE NEAREST FIRE | | | HYDRANT(S) TO THIS PROJECT.PLEASE ACKNOWLEDGE | | | | | | 05.THE ADDRESS AS SHOWN ON SHEET A2.0 IS ACCEPTABLE, | | | HOWEVER IT IS HIGHLY RECOMMENDED THAT THE PLACEMENT OF | | | THOSE NUMBERS BE ON THEBUILDING STRUCTURE ITSELF AS | | | TO PROVIDE BETTER CONTRAST/VISIBILITY AND PREVENTS THE | | | POSSIBILITY OF THE ADDRESS BEING COVERED BY THE | | | INSTALLATION OF HURRICANE AND OR SECURITY SHUTTERS | | | | | | 08.SEPARATE PLANS AND PERMIT WILL BE REQUIRED FOR THE | | | INSTALLATION OF THE COOKING HOOD AND THE COOKING HOOD'S | | | SUPPRESSION SYSTEM.PLEASE ACKNOWLEDGE ON THE | | | APPROPIATE PLAN SHEET(S) | | | | | | 09.SHOW LOCATION OF THE 2A:10BC RATED FIRE | | | EXTINGUISHER(S) WHICH SATISFIES THE 75' TRAVEL | | | DISTANCE.PLEASE SHOW EXTINGUISHER LOCATIONS ON SHEET | | | A1.6 | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-05-21 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-05-21 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-05-21 |
Time |
15:12 |
Sent To |
|
|
| Notes |
| 2007-05-21 16:46:54 | *****DENIED***** | | | | | | | | | 01.THE ACTUAL NUMERICAL ADDRESS OF THE PROJECT SITE | | | SHALL BE IN TITLE BLOCK OF EACH SUBMITTED PLAN SHEET. | | | | | | 02.NFPA 101, 2003 EDITION AND THE FLORIDA FIRE | | | PREVENTION CODE 2004 EDITION SHALL BE REFERENCED. | | | | | | 03.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 04.PLEASE SHOW LOCATION OF THE NEAREST FIRE | | | HYDRANT(S) TO THIS PROJECT. | | | | | | 05.ON THE APPROPIATE EXTERIOR ELEVATION (SHEET A2.0}, | | | DISPLAY THE NUMERICAL ADDRESS.AS PER WEST PALM BEACH | | | CODE, ADDRESS NUMBERS SHALL BE NO LESS THAN 6" IN | | | HEIGHT AND NO LESS THAN 1" IN WIDTH. | | | | | | 06.BASED UPON THE NEW ASSEMBLY OCCUPANCY | | | CLASSIFICATION, DECLARE THE INTERIOR FINISH MATERIAL | | | CLASSIFICATION FOR WALLS AND CEILINGS IN THE EXITS, | | | EXIT ACCESS CORRIDORS, AND ALL OTHER AREAS.BE | | | SPECIFIC AS TO CLASS A, CLASS B, OR CLASS C. | | | | | | 07.COOKING EQUIPMENT SHALL BE PROTECTED IN ACCORDANCE | | | WITH NFPA 96 2001 EDITION. | | | | | | 08.SEPARATE PLANS AND PERMIT WILL BE REQUIRED FOR THE | | | INSTALLATION OF THE COOKING HOOD AND THE COOKING HOOD'S | | | SUPPRESSION SYSTEM. | | | | | | 09.SHOW LOCATION OF THE 2A:10BC RATED FIRE | | | EXTINGUISHER(S) WHICH SATISFIES THE 75' TRAVEL | | | DISTANCE. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
9 |
Status |
N |
Date |
2007-11-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-30 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-30 |
Time |
15:16 |
Sent To |
M |
|
| Notes |
| 2007-11-30 15:17:09 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
8 |
Status |
N |
Date |
2007-11-15 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-15 |
Time |
08:29 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-15 |
Time |
08:29 |
Sent To |
|
|
| Notes |
| 2007-11-27 14:35:35 | TO "COMM" BD#1 | | 2007-11-15 08:30:13 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2007-11-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-11-09 |
Time |
08:37 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-11-09 |
Time |
08:37 |
Sent To |
B |
|
| Notes |
| 2007-11-09 08:37:34 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-10-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-22 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-22 |
Time |
09:56 |
Sent To |
|
|
| Notes |
| 2007-11-05 11:29:02 | TO "COMM" BD#30 | | 2007-10-22 09:57:04 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-10-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-12 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-12 |
Time |
10:34 |
Sent To |
B |
|
| Notes |
| 2007-10-12 10:34:19 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-10-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-03 |
Time |
12:15 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-03 |
Time |
12:15 |
Sent To |
|
|
| Notes |
| 2007-10-25 15:30:09 | TO "COMM" BD#44 | | 2007-10-03 12:15:31 | WAITING FOR "COMM" BD-REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-08-28 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-28 |
Time |
10:12 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-28 |
Time |
10:12 |
Sent To |
|
|
| Notes |
| 2007-09-20 17:06:58 | TO "COMM" BD#37 | | 2007-08-28 10:13:04 | WAITING FOR "COMM" BD-NEW "MECH" SHEET SUBMITTED |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-06-25 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-06-25 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-06-25 |
Time |
09:53 |
Sent To |
|
|
| Notes |
| 2007-07-09 15:23:43 | TO "COMM" BD#40 | | 2007-06-25 09:54:05 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-05-21 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-05-21 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-03-26 |
Time |
18:14 |
Sent To |
|
|
| Notes |
| 2007-03-27 17:58:27 | TO COMM BOARD # 51 PLANS ON RACK | | 2007-03-26 18:14:38 | WAITING FOR COMM BOARD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-12-04 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-12-04 |
Time |
14:45 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-12-04 |
Time |
14:20 |
Sent To |
PC |
|
| Notes |
| 2007-12-04 14:45:41 | REV.3 PG M1.0 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2007-11-26 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-11-15 |
Time |
17:23 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-11-13 |
Time |
18:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-09-20 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-09-20 |
Time |
17:42 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-09-20 |
Time |
17:38 |
Sent To |
|
|
| Notes |
| 2007-09-20 17:43:00 | M4.0 RESTAMPED. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2007-07-26 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-07-26 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-07-26 |
Time |
10:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-04-21 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-04-21 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-04-20 |
Time |
08:56 |
Sent To |
|
|
| Notes |
| 2007-04-21 09:28:00 | -----------------DENIED------------------- | | | | | | FBC 2004 CODE FAMILY W/2006 REVISIONS. | | | FBC 2004 CH 1 AS AMENDED BY THE CITY OF WEST PALM | | | BEACH | | | | | | THE FOLLOWING COMMENTS ARE ORGANIZED BY PAGE # FOR | | | REFERENCE. AREAS RELATED TO REVIEW COMMENTS HAVE BEEN | | | MARKED ON PLAN (1 SET) WHEN PRACTICAL. | | | | | | 1. A1.4 NOTE #5: PLEASE REFERENCE CORRECT CODE BODY, | | | FBC 2004, AND CODE SECTION, 1509.7. | | | | | | 2. A5.4 DETAIL #13: DETAIL SHOWS TOP OF KITCHEN EXHAUST | | | FAN MIN. 40" ABOVE LOW SIDE OF PITCHED ROOF. THIS WOULD | | | MEAN THE ELEVATION COULD BE LESS THAN 40" FROM THE HIGH | | | SIDE OF THE ROOF. PLEASE SHOW MIN. 40" FROM THE HIGH | | | SIDE TO SHOW COMPLIANCE WITH FBC,M 506.3.12.1. | | | | | | 3. A5.4 DETAIL #13: EXHAUST OUTLETS SHALL BE LOCATED | | | NOT LESS THAN 10' HORIZONTALLY FROM PARTS OF THE SAME | | | OR CONTIGUOUS BUILDINGS PER FBC,M 506.3.12.3. THE | | | EXCEPTION UNDER 506.5.5 ALLOWS THE FAN TO BE WITHIN 2' | | | OF PARAPET TYPE WALLS IF THE WALL IS NOT HIGHER THAN | | | THE DISCHARGE OPENING. | | | | | | 4. M1.0 NOTE #2 AND MECH. GENERAL NOTE #22 (M3.0) AND | | | CEILING DIFFUSER RUNOUT DETAIL (M3.0) ARE IN CONFLICT | | | WITH MECH. GENERAL NOTE #18. PLEASE COORDINATE | | | DRAWINGS. FBC 106.1.1. | | | | | | 5. M3.0 MECH. GENERAL NOTE #17: PLEASE PROVIDE DETAIL | | | FOR SUPPORT OF DIFFUSERS, REGISTERS AND GRILLS IF THEY | | | ARE NOT TO BE SUPPORTED BY CEILING AS SHOWN IN THE | | | DIFFUSER RUNOUT DETAIL ON SAME PAGE. | | | | | | 6. M3.0 MECH. GENERAL NOTE #19: DOES THIS NOTE APPLY TO | | | THE MAIN BRANCHES FROM SUPPLY PLENUMS ON RTU-1 AND | | | RTU-3? | | | | | | 7. M3.0 ROOFTOP A/C UNIT NOTE #3: HOW WILL A 12" TALL | | | FACTORY ROOF CURB ALL FOR MIN. *" ABOVE FINISHED ROOF | | | WITH A BUILT-UP ROOF SYSTEM EXCEEDING 4" THICK AS | | | INDICATED BY NOTES ON PG A1.4? | | | | | | 8. ARCHITECTURAL AND STRUCTURAL PLANS CONTAIN DIFFERENT | | | DETAIL DRAWINGS FOR SECURING ROOFTOP EQUIPMENT AND | | | CURBS. PLEASE COORDINATE DRAWINGS. PLEASE HAVE THE | | | DESIGNER RESPONSIBLE FOR STRUCTURAL DESIGN SHOW | | | COMPLIANCE WITH FBC,M 301.13 AND FBC CH 16, SHOWING | | | ROOFTOP EQUIPMENT ATTACHMENTS TO BE DESIGNED TO MEET | | | 140 MPH WIND LOADS. | | | | | | NOTE: SEPARATE PERMITS ARE REQUIRED FOR HOODS, HOOD | | | SUPPRESSION SYSTEMS AND WALK-IN COOLERS/FREEZERS. | | | | | | REVIEWED BY: | | | RONALD J REGUEIRO | | | 561.805-6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2007-11-30 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-11-30 |
Time |
16:19 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-11-30 |
Time |
16:19 |
Sent To |
PC |
|
| Notes |
| 2007-11-30 16:21:07 | REVISIONS: "OK" SHEETS P1.0, P2.0, P4.0 AND P5.0. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-10-01 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-10-01 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-10-01 |
Time |
14:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2007-09-28 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-09-28 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-09-28 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2007-09-28 17:32:51 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | WEST PALM BEACH MUNICIPAL CODE | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | ****FROM PREVIOUS REVIEW**** | | | ******FROM PREVIOUS REVIEWS | | | | | | 1. OK | | | | | | 2. SHT 2 OF 2 SHALL BE SIGNED, SEALED, & DATED PER | | | SECTION 106.1 AND FS 472.025. | | | ****NO RESPONSE/NOT ADDRESSED. | | | ******RESPONSE NOTED, BUT I HAVE NO RECOLLECTION OF A | | | CONVERSATION INDICATING THAT SHT 2 OF 2 DID NOT HAVE TO | | | BE SIGNED, SEALED & DATED. SEE ATTACHED SHEET FROM THE | | | FLORIDA STATUTES THAT INDICATES THIS REQUIREMENT. | | | | | | 3. OK | | | | | | 4. OK | | | 5. OK | | | 6. OK | | | 7. OK | | | 8. OK | | | 9, OK | | | | | | 10. ROUTE PLANS TO THE DEPT. OF BUSINESS REGULATION, | | | HOTEL AND RESTURANT DIVISION FOR REVIEW PRIOR TO | | | RESUBMITTING TO THE CITY. ATTACH THE TWO PAGE | | | "WORKSHEET" TO EACH SET OF PLANS STAMPED BY DBPR. PHONE | | | NUMBER (850)487-1395. SECTION 102.2.1. ****RESPONSE | | | NOTED, BUT THE TWO PAGE "WORKSHEETS" HAVE NOT BEEN | | | ATTACHED TO THE STAMPED SHEET ON EACH SET OF PLAN AS | | | REQUIRED. | | | ******RESPONSE NOTED, BUT THE TWO PAGE "WORKSHEETS" | | | HAVE NOT BEEN ATTACHED TO THE STAMPED SHEET. | | | | | | 11. OK | | | 12. OK | | | 13. OK | | | 14. OK | | | 15. OK | | | 16. OK | | | 17. OK | | | 18. OK | | | 19. OK | | | 20. OK | | | 21. OK | | | 22. OK | | | 23. OK | | | 24. OK | | | 25, OK | | | 26. OK | | | 27. OK | | | 28. OK | | | 29. OK | | | | | | **********NEW COMMENT********** | | | | | | 1B. SEE ATTACHED COPY OF FS 553.80(2)(B) CONCERNING THE | | | DESIGN PROFESSIONAL AND REPEAT COMMENTS. THIS IS GIVEN | | | AS A NOTICE ONLY AT THIS TIME. | | | | | | **********NEW COMMENT********** | | | | | | 1C. SHEETS C-10A & C-10B HAVE NOT BEEN SIGNED, SEALED, | | | DATED AS REQUIRED. FAC 61G15-23.002(2) & FS 471.025. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | AND RESUBMITTING 1 SET OF PLANS FROM THE | | | PREVIOUS REVIEW WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-07-18 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-07-18 |
Time |
06:16 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-07-17 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2007-07-18 06:36:06 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | WEST PALM BEACH MUNICIPAL CODE | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | ****FROM PREVIOUS REVIEW**** | | | | | | 1. SHT 1 OF 1 SHALL BE SIGNED, SEALED, & DATED PER | | | SECTION 106.1 AND SHALL COMPLY WITH FAC 61G1-16.004 AS | | | WELL AS FS 481.219 & 481.2055. | | | ****NO RESPONSE/NOT ADDRESSED. | | | | | | 2. SHT 2 OF 2 SHALL BE SIGNED, SEALED, & DATED PER | | | SECTION 106.1 AND FS 472.025. | | | ****NO RESPONSE/NOT ADDRESSED. | | | | | | 3. SHT C-1 THE BUSINESS NUMBER IS REQUIRED IN THE TITLE | | | BLOCK OF THE DESIGN PROFESSIONAL. (SEE ATTACHED SHEET). | | | FAC 61G15-23.002 & FS 471.025. | | | ****NO RESPONSE/NOT ADDRESSED. | | | | | | 4. SHT C-1 SHEET INDEX INDICATES SHTS C-10, L-1, L-2, | | | IRR-1 & S-3. THESE SHEETS HAVE NOT BEEN SUBMITTED. | | | PLEASE CORRELATE THE SHEET INDEX WITH THE SHEETS | | | SUBMITTED. | | | ****RESPONSE NOTED, BUT SHEETS L-2, S-3 & C-11 WERE NOT | | | FOUND AND SHEET IRR-2 IS NOT SHOWN ON THE SHEET INDEX. | | | PLEASE CORRELATE INFORMATION ON THE SHEET INDEX AND | | | SHEETS SUBMITTED. | | | | | | 5. SHTS C-1 THRU C-9B. THE ADDRESS IN THE TITLE BLOCK | | | DOES NOT REFLECT THE ADDRESS OF RECORD ON FILE IN THE | | | STATE DBPR WEBSITE. PLEASE UPDATE THE DBPR WEBSITE OR | | | THE TITLE BLOCK. FAC 61G1-16.004(1). (SEE ATTACHED | | | SHEET). | | | ****NO RESPONSE/NOT ADDRESSED. - ALL C-SHTS SHALL HAVE | | | AN ADDRESS THAT REFLECTS THE DBPR WEBSITE ADDRESS OF | | | RECORD. | | | | | | 6. SHT C-7 2-WAY CLEANOUTS ARE REQUIRED PRIOR TO, | | | BETWEEN & AT THE EXIT OF EACH GREASE INTERCEPTOR. | | | UTILITY STANDARD. (SEE ATTACHED SHEET). | | | ****NO RESPONSE/NOT ADDRESSED. | | | | | | 7.OK | | | | | | 8. SHTS C-1 THRU C-7 THE SIGNATURE OF THE ENGINEER OF | | | RECORD IS REQUIRED ON EACH SHEET. IT APPEARS THAT | | | INITIALS HAVE BEEN USED. IF THIS IS INDEED THE LEGAL | | | SIGNATURE OF THE ENGINEER, A SIGNED, SEALED, DATED, | | | NOTORIZED LETTER SHALL BE SUBMITTED INDICATING THE | | | LEGAL SIGNATURE OF THE ENGINEER FOR OUR FILE. FAC | | | 61G1-15.02(1)(2) & FS 471.025. | | | ****NO RESPONSE/NOT ADDRESSED. | | | | | | 9, OK | | | | | | 10. ROUTE PLANS TO THE DEPT. OF BUSINESS REGULATION, | | | HOTEL AND RESTURANT DIVISION FOR REVIEW PRIOR TO | | | RESUBMITTING TO THE CITY. ATTACH THE TWO PAGE | | | "WORKSHEET" TO EACH SET OF PLANS STAMPED BY DBPR. PHONE | | | NUMBER (850)487-1395. SECTION 102.2.1. ****RESPONSE | | | NOTED, BUT THE TWO PAGE "WORKSHEETS" HAVE NOT BEEN | | | ATTACHED TO THE STAMPED SHEET ON EACH SET OF PLAN AS | | | REQUIRED. | | | | | | 11. THE GREASE INTERCEPTOR SHALL BE SIZED BY THE | | | ENVIRONMENTAL COMPLIANCE MANAGER. PLEASE CONTACT RODNEY | | | COMPO (561) 822-2272 OR CALVIN WILLIAMS (561) 822-2284. | | | THEIR FAX NUMBER IS (561) 822-2287 AND THEIR E-MAILS | | | ARE [email protected], OR [email protected]. | | | ****NO RESPONSE. I HAVE SENT AN E-MAIL TO ENVIRONMENTAL | | | COMPLIANCE TO GET DETERMINATION OF INTERCEPTOR SIZE | | | REQUIRED. | | | | | | 12. OK | | | 13. OK | | | 14. OK | | | 15. OK | | | | | | 16. SHT P2.0 INDICATES A FILTERED WATER SYSTEM. THE | | | WATER FILTER SHALL COMPLY WITH SECTION 611.1 AND NSF | | | 42. PLEASE SUBMIT MANUF. SPECIFICATION SHEETS SHOWING | | | COMPLIANCE. | | | ****RESPONSE NOTED, BUT MANUF. SPECS NOT SUBMITTED. | | | | | | 17. SHT P2.0 PLUMBING KEY NOTES #12. MORE INFORMATION | | | IS REQUIRED. SECTION 106.1.2. PLEASE INDICATE HOW THE | | | COLD WATER WILL BE TREATED. SUBMIT MANUF. SPECIFICATION | | | SHEETS FOR THE PROCESS & SHOW COMPLIANCE WITH NSF. ALL | | | POTABLE WATER LINES SHALL BE INSTALLED BY A LICENSED | | | PLUMBER. | | | ****RESPONSE NOTED, BUT MANUF. SPECS NOT SUBMITTED. | | | | | | 18. OK | | | 19. OK | | | 20. OK | | | 21. OK | | | 22. OK | | | 23. OK | | | 24. OK | | | | | | 25, SUBMIT A STORM PIPING RISER DIAGRAM IN ISOMETRIC | | | FORM. SECTION 106..3.5.1.3(7)(13). | | | ****RESPONSE NOTED, BUT MINIMUM 5" PIPE IS REQUIRED FOR | | | 1738SF, (DOWNSTREAM OF FIRST TWO ROOF DRAINS). TABLE | | | 1106.3. | | | | | | 26. OK | | | 27. OK | | | 28. OK | | | 29. OK | | | | | | **********NEW COMMENT********** | | | | | | 1B. SEE ATTACHED COPY OF FS 553.80(2)(B) CONCERNING THE | | | DESIGN PROFESSIONAL AND REPEAT COMMENTS. THIS IS GIVEN | | | AS A NOTICE ONLY AT THIS TIME. | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | AND RESUBMITTING 1 SET OF PLANS FROM THE | | | PREVIOUS REVIEW WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-05-04 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-05-04 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-05-04 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2007-05-04 16:58:08 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | WEST PALM BEACH MUNICIPAL CODE | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. SHT 1 OF 1 SHALL BE SIGNED, SEALED, & DATED PER | | | SECTION 106.1 AND SHALL COMPLY WITH FAC 61G1-16.004 AS | | | WELL AS FS 481.219 & 481.2055. | | | | | | 2. SHT 2 OF 2 SHALL BE SIGNED, SEALED, & DATED PER | | | SECTION 106.1 AND FS 472.025. | | | | | | 3. SHT C-1 THE BUSINESS NUMBER IS REQUIRED IN THE TITLE | | | BLOCK OF THE DESIGN PROFESSIONAL. (SEE ATTACHED SHEET). | | | FAC 61G15-23.002 & FS 471.025. | | | | | | 4. SHT C-1 SHEET INDEX INDICATES SHTS C-10, L-1, L-2, | | | IRR-1 & S-3. THESE SHEETS HAVE NOT BEEN SUBMITTED. | | | PLEASE CORRELATE THE SHEET INDEX WITH THE SHEETS | | | SUBMITTED. | | | | | | 5. SHTS C-1 THRU C-9B. THE ADDRESS IN THE TITLE BLOCK | | | DOES NOT REFLECT THE ADDRESS OF RECORD ON FILE IN THE | | | STATE DBPR WEBSITE. PLEASE UPDATE THE DBPR WEBSITE OR | | | THE TITLE BLOCK. FAC 61G1-16.004(1). (SEE ATTACHED | | | SHEET). | | | | | | 6. SHT C-7 2-WAY CLEANOUTS ARE REQUIRED PRIOR TO, | | | BETWEEN & AT THE EXIT OF EACH GREASE INTERCEPTOR. | | | UTILITY STANDARD. (SEE ATTACHED SHEET). | | | | | | 7.SHTS C-8, C-9, C-9A & C-9B ARE NOT SIGNED & SEALED. | | | THE DATE THAT THE SEAL AND SIGNATURE ARE AFFIXED TO THE | | | SHEETS SHALL BE ENTERED BELOW THE SIGNATURE. FAC | | | 61G1-15.002(1)(2) & FS 471.025. | | | | | | 8. SHTS C-1 THRU C-7 THE SIGNATURE OF THE ENGINEER OF | | | RECORD IS REQUIRED ON EACH SHEET. IT APPEARS THAT | | | INITIALS HAVE BEEN USED. IF THIS IS INDEED THE LEGAL | | | SIGNATURE OF THE ENGINEER, A SIGNED, SEALED, DATED, | | | NOTORIZED LETTER SHALL BE SUBMITTED INDICATING THE | | | LEGAL SIGNATURE OF THE ENGINEER FOR OUR FILE. FAC | | | 61G1-15.02(1)(2) & FS 471.025. | | | | | | 9, SHT A1.4 SUBMIT CALCULATIONS FOR PRIMARY AND | | | SECONDARY ROOF DRAINS PER SECTIONS 1106 & 1107 WITH ALL | | | SUBSECTIONS & TABLES. SHOW THE SQUARE FOOTAGE OF EACH | | | AREA TO BE DRAINED WITH 1/2 AREA OF ALL VERTICAL WALLS | | | INCLUDING PARAPETS AS WELL AS ANY ROOF AREA THAT WILL | | | BE DRAINED ON TO THE ROOF AREA FROM ABOVE. | | | | | | 10. ROUTE PLANS TO THE DEPT. OF BUSINESS REGULATION, | | | HOTEL AND RESTURANT DIVISION FOR REVIEW PRIOR TO | | | RESUBMITTING TO THE CITY. ATTACH THE TWO PAGE | | | "WORKSHEET" TO EACH SET OF PLANS STAMPED BY DBPR. PHONE | | | NUMBER (850)487-1395. SECTION 102.2.1. | | | | | | 11. THE GREASE INTERCEPTOR SHALL BE SIZED BY THE | | | ENVIRONMENTAL COMPLIANCE MANAGER. PLEASE CONTACT RODNEY | | | COMPO (561) 822-2272 OR CALVIN WILLIAMS (561) 822-2284. | | | THEIR FAX NUMBER IS (561) 822-2287 AND THEIR E-MAILS | | | ARE [email protected], OR [email protected]. | | | | | | 12. SHT A4.0 DETAIL #6 INDICATES THE TOILET PAPER | | | DISPENSER AT 15" MINIMUM. THE MINIMUM TO THE CENTERLINE | | | OF THE DISPENSER IS 19" PLEASE INDICATE ON THE PLAN. | | | SEE FIG. 11-29B. | | | | | | 13. SHT A4.0 THE LAV CALLS FOR A COMBINATION FAUCET. | | | MORE INFORMATION IS REQUIRED. PLEASE SUBMIT MANUF. | | | SPECIFICATION SHEETS FOR THE FAUCET SHOWING COMPLIANCE | | | WITH SECTION 11-4.19.5. | | | | | | 14. SHT P1.0PLUMBING KEY NOTE #8. CHANGE FROM FLOOR | | | DRAIN TO FLOOR SINK. FLOOR DRAINS ARE NOT APPROVED | | | INDIRECT WASTE RECEPTORS. SECTION 802.3. | | | | | | 15. ALL MECHANICAL & PLUMBING SHEETS. THE SIGNATURE OF | | | THE ENGINEER OF RECORD IS REQUIRED ON EACH SHEET. IT | | | APPEARS THAT INITIALS HAVE BEEN USED. IF THIS IS INDEED | | | THE LEGAL SIGNATURE OF THE ENGINEER, A SIGNED, SEALED, | | | DATED, NOTORIZED LETTER SHALL BE SUBMITTED INDICATING | | | THE LEGAL SIGNATURE OF THE ENGINEER FOR OUR FILE. FAC | | | 61G1-15.02(1)(2) & FS 471.025. | | | | | | 16. SHT P2.0 INDICATES A FILTERED WATER SYSTEM. THE | | | WATER FILTER SHALL COMPLY WITH SECTION 611.1 AND NSF | | | 42. PLEASE SUBMIT MANUF. SPECIFICATION SHEETS SHOWING | | | COMPLIANCE. | | | | | | 17. SHT P2.0 PLUMBING KEY NOTES #12. MORE INFORMATION | | | IS REQUIRED. SECTION 106.1.2. PLEASE INDICATE HOW THE | | | COLD WATER WILL BE TREATED. SUBMIT MANUF. SPECIFICATION | | | SHEETS FOR THE PROCESS & SHOW COMPLIANCE WITH NSF. ALL | | | POTABLE WATER LINES SHALL BE INSTALLED BY A LICENSED | | | PLUMBER. | | | | | | 18. SHT P2.0 AIR CHAMBERS ARE NOT APPROVED. DELETE | | | REFERENCE. SECTION 604.9 & PDI-WH 210. | | | | | | 19. SHT P4.0 THREE FD-1 FIXTURES ARE NOT APPROVED AS | | | INDIRECT WASTE RECEPTORS SECTION 802.3. FLOOR SINKS | | | SHALL BE USED FOR ALL EXCEPT A HUB DRAIN CAN BE USED | | | FOR THE CONDENSATE DRAIN FOR THE FREEZER PER SECTION | | | 802.3.2. | | | | | | 20. SHT P5.0 AIR CHAMBERS ARE NOT APPROVED. DELETE FROM | | | THE RISER DIAGRAM. SECTION 604.9 & PDI-WH 201. WATER | | | HAMMER ARRESTORS ARE REQUIRED AT QUICK CLOSING VALVES, | | | (ICE MACHINE, DISH WASHER, WASH MACHINE). WATER HAMMER | | | ARRESTORS SHALL BE LOCATED NEAR THE FIXTURE IN AN | | | "EFFECTIVE RANGE" NOT IN THE CEILING. PDI-WH 201 AND | | | MANUF. INSTALLATION INSTRUCTIONS. | | | | | | 21. SHT P5.0 A FULL OPEN VALVE IS REQUIRED ON THE WATER | | | SUPPLY PIPE TO THE WATER HEATER. SECTION 606.1(7). | | | | | | 22. SHT P5.0 RISER DIAGRAM. PLEASE IDENTIFY THE SYMBOLS | | | ON THE WATER SUPPLY LINES TO THE TRASH AREA AND TO THE | | | HOSE BIBB ON THE ROOF. THE SYMBOL IS NOT INDICATED ON | | | THE PLUMBING LEGEND SHT P1.0. SECTION 106.1.1. | | | | | | 23. SHT P5.0 THE 2" WATER MAIN IS SHOWN REDUCED TO 1/2" | | | AT THE TOP OF THE FIRST RISER DOWNSTREAM OF THE | | | SUB-METER. PLEASE CLARIFY. SECTION 106.1.1. | | | | | | 24. SHT P6.1 PLUMBING FIXTURE & PIPE SIZING SCHEDULE. | | | FD-1 FUNNEL FLOOR DRAINS ARE NOT APPROVED FOR INDIRECT | | | WASTE. PLEASE DELETE FROM THE SCHEDULE. SECTION 802.3. | | | | | | 25, SUBMIT A STORM PIPING RISER DIAGRAM IN ISOMETRIC | | | FORM. SECTION 106..3.5.1.3(7)(13). | | | | | | 26. SHT P7.0 FLOOR SINK DETAIL. THE TOP OF THE FLOOR | | | SINK SHALL BE 1" ABOVE FINISH FLOOR TO PREVENT THE | | | FLOOR SINK BEING USED AS A FLOOR DRAIN. | | | | | | 27. SHT P8.0 SEE ATTACHED SHEET FOR AN APPROVED UTILITY | | | STANDARD FOR THE GREASE INTERCEPTOR. | | | | | | 28. SHT P8.0 NOTE #1 CONCRETE GREASE INTERCEPTORS ARE | | | REQUIRED. POLYETHYLENE TANKS ARE NOT APPROVED. CITY | | | CODE SECTION 90-124(7)(F). | | | | | | 29. SUBMIT A PLUMBING ROOF PLAN SHOWING ALL VENT | | | LOCATIONS ON THE ROOF. SECTION 106.2.1 | | | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | AND RESUBMITTING 1 SET OF PLANS FROM THE | | | PREVIOUS REVIEW WILL HELP TO EXPEDITE YOUR | | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
5 |
Status |
P |
Date |
2007-11-15 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-11-15 |
Time |
10:46 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-11-15 |
Time |
10:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2007-11-14 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-11-14 |
Time |
15:26 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-11-14 |
Time |
15:26 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-08-31 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-08-31 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-08-31 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2007-08-31 13:41:14 | ***PASSED WITH PROVISO*** | | | | | | 1) PRIOR TO THE INSTALLATION OF ANY LANDSCAPING, A | | | REVISION SHALL BE SUBMITTED PROVIDING THAT THE | | | LANDSCAPE PLANS MATCH THE APPROVED SITE PLAN (I.E. | | | LOCATION OF THE SIGN, ETC.). | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-08-13 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-08-13 |
Time |
21:14 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-08-13 |
Time |
21:14 |
Sent To |
|
|
| Notes |
| 2007-08-13 21:19:41 | ***FAILED*** | | | | | | 1) THE LOCATION OF THE MONUMENT SIGN ON SHEET C-5 DOES | | | NOT MATCH THE APPROVED SITE PLAN, NOR DOES IT MATCH THE | | | MASTER SIGN PROGRAM APPROVED BY THE CITY COMMISSION. | | | IN ORDER TO CHANGE THE LOCATION OF THE SIGN FROM WHAT | | | WAS PREVIOUSLY APPROVED, A MINOR AMENDMENT TO THE | | | BAYWINDS RESIDENTIAL PLANNED DEVELOPMENT (RPD) SHALL BE | | | SUBMITTED TO AND APPROVED BY THE PLANNING DEPARTMENT. | | | FYI...THE MONUMENT SIGN SHALL BE PERMITTED UNDER A | | | SEPARATE PERMIT. | | | | | | 2) PLEASE CLARIFY WHY CURBS/GUTTERS ARE BEING SHOWN | | | BETWEEN THE LANDSCAPE ISLANDS AND THE BUFFER ALONG THE | | | EDGE OF THE PARKING.STAFF DID NOT UNDERSTAND THE | | | CONTRACTOR'S RESPONSE. | | | | | | 3) THE PHOTOMETRIC PLAN SUBMITTED SHALL BE MODIFIED. | | | LEVELS SHALL NOT EXCEED 1.0 FOOTCANDLES WHEN MEASURED | | | AT THE OKEECHOBEE BOULEVARD ROW AND SHALL NOT EXCEED | | | 0.5 FOOTCANDLES WHEN MEASURED AT THE RESIDENTIAL | | | PROPERTY LINES. | | | | | | 4) THE PARKING DETAIL ON SHEET C-8 SHALL CONFORM TO THE | | | MINIMUM STANDARDS WITHIN THE CITY'S ZONING AND LAND | | | DEVELOPMENT REGULATIONS (I.E. DOUBLE-STRIPING, ETC.). | | | PLEASE SEE ATTACHED DETAIL FOR REFERENCE. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-04-06 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-04-06 |
Time |
17:19 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-04-06 |
Time |
17:19 |
Sent To |
|
|
| Notes |
| 2007-04-06 17:32:07 | ***FAILED*** | | | | | | 1) IS THE GENERAL OFFICE/RETAIL SITE AND/OR BUILDING | | | BEING CONSTRUCTED AS PART OF THIS PERMIT?IF NOT, | | | PLEASE REMOVE FROM THE PLANS, OR INDICATE WHAT WILL BE | | | UNDER THIS PERMIT OR UNDER A SEPARATE PERMIT. | | | | | | 2) PLEASE CLARIFY WHICH DUMPSTER ENCLOSURE WILL BE | | | USED.DETAILS ARE SHOWN ON SHEET 1 OF 1 AND ON SHEET | | | A0.0.THE DETAIL ON SHEET A0.0 DOES NOT MATCH ANY OF | | | THE SITE PLANS.PLEASE REMOVE OF CROSS OUT WHAT IS NOT | | | BEING PROPOSED. | | | | | | 3) DUMPSTER OPENINGS SHALL BE A MINIMUM OF 12 FEET 6 | | | INCHES IN CLEAR WIDTH. | | | | | | 4) THE LANDSCAPE BUFFER ALONG THE EAST PROPERTY LINE | | | SHALL BE A MINIMUM OF 5 FEET IN WIDTH. | | | | | | 5) THE ZONING AND FUTURE LAND USE DESIGNATIONS SHOWN IN | | | THE SITE DATA TABLE ON SHEET C-5 IS INCORRECT. | | | | | | 6) THE SITE ACREAGE SHOWN ON SHEET C-5 DOES NOT MATCH | | | SHEET 1 OF 1, NOR THE SURVEY. | | | | | | 7) THE BIKE RACK SHOWN ON SHEET 1 OF 1 IS NOT SHOWN ON | | | SHEET C-5...AND IT APPEARS THAT IT MAY CONFLICT WITH | | | THE FLAG POLE. | | | | | | 8) THE LOCATION OF THE MONUMENT SIGN ON SHEET C-5 DOES | | | NOT MATCH SHEET 1 OF 1. | | | | | | 9) PLEASE CLARIFY WHY CURBS/GUTTERS ARE BEING SHOWN | | | BETWEEN THE LANDSCAPE ISLANDS AND THE BUFFER ALONG THE | | | EDGE OF THE PARKING LOT. | | | | | | 10) A PHOTOMETRIC PLAN SHALL BE PROVIDED. | | | | | | 11) A DETAIL OF THE PARKING LOT LIGHTING SHALL BE | | | PROVIDED AND SHALL MATCH THE ADJACENT COMMERCIAL | | | PARCELS. | | | | | | 12) PLEASE PROVIDE A DETAIL OF THE FLAG POLE (I.E. | | | HEIGHT). | | | | | | 13) THE "M" SYMBOL/LOGO IS CONSIDERED SIGNAGE, AND | | | SHALL NOT BE PERMITTED ON THE ENTRANCE/EXIT SIGNS | | | (SHEET C-8), NOR ON THE GATEWAY CLEARANCE BAR, CANOPY, | | | ETC. | | | | | | 14) LANDSCAPE PLAN SHALL BE PROVIDED. | | | | | | 15) THE DIMENSIONS OF THE ANGLED PARKING SHALL CONFORM | | | TO THE CITY'S ZONING AND LAND DEVELOPMENT REGULATIONS. | | | PLEASE CONTACT ME REGARDING THIS ISSUE!!! | | | | | | NOTE: PLEASE ENSURE THAT ALL PLANS ARE CONSISTENT.IT | | | IS RECOMMENDED THAT ONLY ONE (1) SITE PLAN BE PROVIDED | | | AND UTILIZED, AND THAT ALL PLANS BE CONSISTENT WITH | | | THAT ONE. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |