| Plan Review Stops For Permit 07030665 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2007-04-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-04-20 |
Time |
18:40 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-04-20 |
Time |
18:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-05-09 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-05-09 |
Time |
10:37 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2007-05-09 |
Time |
10:32 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-03-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-03-28 |
Time |
07:55 |
Rev Time |
0.33 |
| Received By |
btrobaug |
Date |
2007-03-28 |
Time |
07:42 |
Sent To |
M |
|
| Notes |
| 2007-03-28 07:55:49 | | | | | | | | | | DENIED/INCOMPLETE INFORMATION. | | | | | | 1} PROVIDE A RISER DIAGRAM PER 215.5 | | | INCLUDING GENERATOR AND RELATED | | | EQUIPMENT. | | | | | | 2} PLEASE LOCATE ALL SERVICE AND GENERATOR EQUIPMENT ON | | | A SITE PLAN, NOT THE SURVEY, METER ENCLOSURE, | | | DISCONNECTS, ATS AND PANELS, SO THAT COMPLIANCE WITH | | | ARTICLES 225 AND 230 CAN BE REVIEWED. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLAN REVIEW | | | 561/805-6718 | | | [email protected] |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2007-05-10 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-05-10 |
Time |
08:03 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2007-05-10 |
Time |
08:03 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2007-04-11 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-04-11 |
Time |
09:06 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2007-04-11 |
Time |
09:06 |
Sent To |
B |
|
| Notes |
| 2007-04-11 10:37:28 | DENIED | | | REFERENCE: | | | ** FBC-2004 FUEL GAS. | | | ** THE CITY OF WEST PALM BEACH GAS AND GEN/RES PERMIT | | | APPLICATION REQUIREMENTS. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | | | | | | | THE FOLLOWING CORRECTIONS/INFORMATIONREQUIRED FOR GAS | | | PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | | AND CORRESPONDING LENGTHS PER FBC-2004 | | | FUEL GAS CODE. | | | NOTE: THE SUBMITTED DRAWING IS NOT AN ISOMETRIC, PLEASE | | | REFERENCE THE ATTACHED ISOMETRIC TO THE GAS COMMENTS | | | REFLECTING THE PROPOSED GAS SYSTEM. CORRESPONDING | | | LENGTHS OF ALL CUT SECTIONS OF PIPE MUST BE INDICATED | | | ON THE RESUBMITTED DRAWING. THE ONLY INDICATED PIPING | | | MEASUREMENT IS FOR THE UNDERGROUND 1/2" PE. WHAT ARE | | | THE CORRESPONDING LENGTHS OF THE ABOVE GROUND PIPING? | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | | NUMBER OF CORRUGATED STAINLESS STEEL | | | TUBING FOR EACH PIPE SIZE BEING USED. | | | NOTE: BOTH THE ABOVE AND UNDERGROUND PIPING MATERIALS | | | AND SIZES MUST BE INDICATED ON THE DRAWINGS. ON THE | | | SUBMITTED GAS CHECKLIST PIPE/TUBING SPECS. COPPER, PE, | | | AND GALV. ARE INDICATED AS PIPING MATERIAL BEING USED | | | BUT ON THE SUBMITTED DRAWING ONLY PE AND GALV. ARE | | | INDICATED AS BEING USED. PLEASE CORRELATE AND CORRECT | | | ON THE RESUBMITTAL | | | | | | 3. SUBMIT MANUFACTURE SPECIFICATION SHEETS FOR THE | | | GENERATOR THAT VERIFIES THE BTU LOAD OF GENERATOR AT | | | 100% RUNNING CAPACITY AND VERIFIES THE BTU LOAD OF | | | 229,000 INDICATED ON THE DRAWINGS. | | | | | | 4. PLEASE SUBMIT TWO COPIES OF THE ABOVE GROUND LP | | | TANK ANCHORING DETAIL FOR THE RESUBMITTAL. | | | | | | 5. CLEARLY SHOW THETYPE OF TANK (DOT | | | OR ASME), THE DISTANCE OF THE TANK FROM | | | THE BUILDING AND ADJACENT PROPERTY LINES | | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | | INGS, AND THE LOCATION OF ANY BUILDING | | | OPENINGS BELOW THE RELIEF VALVE OF THE | | | TANK PER NFPA 58. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-05-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-08 |
Time |
14:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-08 |
Time |
14:51 |
Sent To |
P |
|
| Notes |
| 2007-05-08 14:52:19 | TO "MPERSON" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-05-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-03 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-03 |
Time |
14:01 |
Sent To |
Z |
|
| Notes |
| 2007-05-03 14:01:32 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-03-24 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-24 |
Time |
12:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-24 |
Time |
12:17 |
Sent To |
E |
|
| Notes |
| 2007-03-24 12:17:59 | TO "GEN-RES" "E" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-21 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2007-03-21 15:56:54 | TO "Z" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2007-03-29 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-29 |
Time |
08:27 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-03-29 |
Time |
08:27 |
Sent To |
G |
|
| Notes |
| 2007-03-29 08:29:05 | *** PROVISO *** | | | 1) PER 2004 FBC, FUEL GAS - POWERED | | | EQUIPMENT - PERMANENTLY INSTALLED | | | EQUIPMENT POWERED BY INTERNAL COMBUSTION | | | ENGINES SHALL BE INSTALLED IN ACCORDANCE | | | WITH MANUFACTURER'S INSTALLATION | | | INSTRUCTIONS AND NFPA 37. | | | | | | NFPA 37 INSTALLATION & USE OF STATIONARY COMBUSTION | | | ENGINES & GAS TURBINES: | | | 4.1.4ENGINES (GENERATORS) LOCATED | | | OUTDOORS SHALL BE MINIMUM OF 5 FT FROM | | | OPENINGS IN WALLS & AT LEAST 5 FT FROM | | | STRUCTURES HAVING COMBUSTIBLE WALLS.A | | | MINIMUM CLEARANCE IS NOT REQUIRED WHEN | | | (1) THE ADJACENT WALL HAS A MINIMUM FIRE RESISTANCE | | | RATING OF 1 HOUR OR (2) THE WEATHERPROOF ENCLOSURE IS | | | CONSTRUCTED OF NON-COMBUSTIBLE MATERIALS, AND IT HAS | | | BEEN DEMONSTRATED THAT A FIRE WITHIN THE | | | ENCLOSURE WILL NOT IGNITE COMBUSTIBLE | | | MATERIALS OUTSIDE THE ENCLOSURE. | | | INFORMATIVE: A.8.2.3.1EXHAUST SYSTEMS | | | SHOULD NOT TERMINATE UNDER STRUCTURES OR | | | WHERE THE EXHAUST MIGHT BE DRAWN INTO | | | THE VENTILATION INTAKES. | | | | | | 2004 FMC 804.3.5 #3, WHERE THE | | | TERMINATION IS LOCATED BELOW AN ADJACENT | | | ROOF STRUCTURE, THE TERMINATION POINT | | | SHALL BE LOCATED AT LEAST 3 FT FROM THE | | | ROOF STRUCTURE. | | | | | | PLEASE NOTE, WHILE ZONING ALLOWS | | | MECHANICAL EQUIPMENT TO ENCROACH 4 FT | | | INTO THE REQUIRED SETBACK, GENERATORS | | | SHALL MAINTAIN THE REQUIRED ABOVE | | | MENTIONED CLEARANCES TO THE ADJACENT | | | PROPERTY STRUCTURES, I.E. FENCE, | | | BUILDING, WINDOWS, DOORS, OR OPENINGS. | | | | | | FOLLOW MANUFACTURER'S RECOMMENDED | | | CLEARANCES AROUND EQUIPMENT FOR | | | SERVICING,AND PROVIDE MANUFACTURER'S | | | INSTALLATION INSTRUCTIONS AT THE JOBSITE | | | FOR THE FIELD INSPECTOR. | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-05-07 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-05-07 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-05-04 |
Time |
14:18 |
Sent To |
I |
|
| Notes |
| 2007-05-07 14:19:07 | PER ERIC SCHNEIDER, PRINCIPAL PLANNER. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-03-22 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-03-22 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-03-22 |
Time |
12:09 |
Sent To |
I |
|
| Notes |
| 2007-03-22 15:21:45 | PLANNING AND ZONING DEPARTMENT | | | | | | ***FAILED*** | | | | | | 1.ONLY ONE (1) COPY OF THE SURVEY WAS SUBMITTED WITH | | | THIS PERMIT APPLICATION.NEED TO SUBMIT AN ADDITIONAL | | | COPY. | | | | | | 2.PROVIDE SETBACK DIMENSIONS FROM PROPERTY LINE TO | | | PROPOSED GENERATOR AND GAS TANKS ON BOTH COPIES OF | | | SURVEY. | | | | | | COMMENTS/QUESTIONS CONTACT ANDREINA DAVILA Q. OR ERIC | | | SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435. |
|
|