Plan Review Details - Permit 07030627
| Plan Review Stops For Permit 07030627 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-05-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-05-22 |
Time |
11:32 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-05-22 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2007-05-22 11:32:59 | REVISION TO USE SELF-ADHERING UNDERLAYMENT. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-04-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-04-10 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-04-10 |
Time |
06:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-03-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-03-26 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-03-26 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2007-03-26 13:33:08 | DENIED BY BUILDING | | | | | | 1)THE NOA FOR THE JOHNS MANVILLE BUILT-UP ROOF SYSTEM | | | SPECIFIES A MAXIMUM DESIGN PRESSURE OF -52.5 PSF FOR | | | THE SELECTED SYSTEM, WHICH IS TO LOW FOR ROOF ZONES 2 | | | AND 3. ENHANCED FASTENING IS ALLOWED IN ORDER TO | | | INCREASE THE DESIGN PRESSURES IN THESE AREAS PER | | | GENERAL LIMITATION NUMBER 7 ON PAGE 19 OF THE NOA. | | | HOWEVER, GENERAL LIMITATION NUMBER 7 REQUIRES THAT RAS | | | 117 CALCULATIONS PREPARED, SIGNED AND SEALED BY A | | | FLORIDA REGISTERED ENGINEER, ARCHITECT OR REGISTERED | | | ROOF CONSULTANT. SUBMIT SIGNED AND SEALED RAS 117 | | | CALCULATIONS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-03-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-03-16 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-03-16 |
Time |
17:03 |
Sent To |
|
|
| Notes |
| 2007-03-16 17:22:13 | DENIED BY BUILDING | | | | | | 1)PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. | | | | | | 2) THE NOA FOR THE METAL ROOF IS MISSING THE FIRST PAGE | | | AND THE FLORIDA COVER SHEET WAS NOT SUBMITTED. | | | | | | 3) THE INFORMATION SUBMITTED FOR THE FLAT ROOF IS NOT | | | COMPLETE. SUBMIT THE FL COVER SHEET. SUBMIT A CURRENT | | | EVALUATION REPORT OR NOA THAT SPECIFIES THE DESIGN | | | PRESSURE. SPECIFY THE FASTENING OPTION , THE | | | INSULATION, THE DESIGN PRESSURE, ETC. THAT WILL BE | | | USED. CIRCLE THE APPROPRIATE ITEMS ON THE PRODUCT | | | APPROVALS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-04-09 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-09 |
Time |
13:40 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-09 |
Time |
13:40 |
Sent To |
B |
|
| Notes |
| 2007-04-09 13:40:39 | TO "RMCDOUGAL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-03-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-03-26 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-03-24 |
Time |
14:54 |
Sent To |
|
|
| Notes |
| 2007-03-24 14:54:55 | TO "RMCDOUGAL" DESK/RESUB |
|
|
|