Plan Review Details - Permit 07030591
Plan Review Stops For Permit 07030591
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-04-04 Cont ID  
Sent By mjacobs Date 2007-04-04 Time 06:14 Rev Time 0.00
Received By mjacobs Date 2007-04-04 Time 06:01 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-03-31 Cont ID  
Sent By mjacobs Date 2007-03-31 Time 15:55 Rev Time 0.00
Received By mjacobs Date 2007-03-31 Time 14:49 Sent To  
Notes
2007-03-31 15:49:22PROVISOR:
 WPB ADMIN105.9* IF ASBESTOS IS FOUND IN THE
 BUILDING, FOLLOW THESE PRE-CAUTIONS
 FL.S.S 469. THIS AGENCY IS THE LOCAL ASBESTOS
 AUTHORITY, AND SHOULD RECEIVE ALL NOTIFICATIONS FOR
 BUILDING DEMOLITION OR RENOVATION PROJECTS. CONTACT
 THEM FOR GENERAL INFORMATION ON ASBESTOS ISSUES
 INCLUDING REGULATIONS, CONTRACTORS OR CONSULTANTS.FL SS
 469.003 PALM BEACH COUNTY PUBLIC HEALTH UNIT (DIVISION
 OF ENVIROMENTAL SCIENCE & ENGINEERING AIR POLLUTION
 CONTROL SECTION) 901 EVERNIA STREET WEST PALM BEACH, FL
 33401 (561)366-3070

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-03-22 Cont ID  
Sent By kconrad Date 2007-03-22 Time 16:04 Rev Time 0.00
Received By kconrad Date 2007-03-22 Time 16:04 Sent To I
Notes
2007-03-22 16:05:31REQUIRE PLANS FOR REVIEW.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-03-31 Cont ID  
Sent By dpalmer Date 2007-03-31 Time 09:38 Rev Time 0.00
Received By dpalmer Date 2007-03-31 Time 09:34 Sent To  
Notes
2007-03-31 09:38:40ELECTRICAL DEMO PERMIT REQUIRED BEFORE ANY DEMO WORK
 INVOLVING ELECTRICAL/ELECTRICAL WIRING IS DONE.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2007-04-03 Cont ID  
Sent By mawillia Date 2007-04-03 Time 18:02 Rev Time 0.00
Received By mawillia Date 2007-04-03 Time 17:50 Sent To B
Notes
2007-04-03 17:52:48*****APPROVED W/PROVISO*****
  
 PLAN SHEET A-1 STAMPED, INITIALED, AND DATED.
  
  
 1.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR
 DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241.
  
 2.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL
 BE REMOVED FROM THE SITE AT THE END OF EACH SHIFT OR
 MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION.
  
 3.DEMOLITION OPERATIONS INVOLVING THE USE OF CUTTING
 AND WELDING SHALL BE DONE IN ACCORDANCE WITH NFPA 51B
  
 4.IF THE BUILDING IS PROTECTED BY FIRE PROTECTINON
 SYSTEMS, SUCH SYSTEMS SHALL BE MAINTAINED OPERATIONAL
 AT ALL TIMES DURING ALTERATION.IN THE EVENT THAT IT
 IS NECESSARY TO SHUT DOWN THE SYSTEM, THE FIRE
 DEPARTMENT WILL BE NOTIFIED WHEN IT IS SHUT DOWN AND
 WHEN IT IS RETURNED TO SERVICE.
  
 5.ALL REQUIRED EXIT COMPONENTS SHALL BE MAINTAINED.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-03-29 Cont ID  
Sent By dpalmer Date 2007-03-29 Time 19:56 Rev Time 0.00
Received By dpalmer Date 2007-03-29 Time 19:56 Sent To  
Notes
2007-03-29 19:59:44TO BOB BOARD #18

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-03-29 Cont ID  
Sent By dpalmer Date 2007-03-22 Time 19:57 Rev Time 0.00
Received By dpalmer Date 2007-03-29 Time 19:57 Sent To  
Notes
2007-03-29 19:57:55FAILED BY KC.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2007-03-30 Cont ID  
Sent By tgordon Date 2007-03-30 Time 10:04 Rev Time 0.15
Received By tgordon Date 2007-03-30 Time 10:04 Sent To  
Notes
2007-03-30 10:04:53DEMO.

Review Stop P PLUMBING
Rev No 1 Status N Date 2007-03-31 Cont ID  
Sent By jleech Date 2007-03-31 Time 12:38 Rev Time 0.00
Received By jleech Date 2007-03-31 Time 12:38 Sent To  
Notes
2007-03-31 12:39:04NO PLUMBING WORK SHOWN ON DEMO PLAN