Plan Review Details - Permit 07030525
Plan Review Stops For Permit 07030525
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-07-13 Cont ID  
Sent By mjacobs Date 2007-07-13 Time 06:23 Rev Time 0.00
Received By mjacobs Date 2007-07-13 Time 05:57 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2007-03-30 Cont ID  
Sent By mjacobs Date 2007-03-30 Time 15:46 Rev Time 0.00
Received By mjacobs Date 2007-03-30 Time 10:11 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2007-07-11 Cont ID  
Sent By btrobaug Date 2007-07-11 Time 17:14 Rev Time 0.00
Received By btrobaug Date 2007-07-11 Time 16:59 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-03-22 Cont ID  
Sent By btrobaug Date 2007-03-22 Time 07:33 Rev Time 1.00
Received By btrobaug Date 2007-03-22 Time 06:38 Sent To  
Notes
2007-03-22 07:33:36 
  
  
 PROVISO
  
 PER 2704.1, 2004 FBC, METAL FRAMING MEMBERS SHALL BE
 BONDED TO THE EQUIPMENT GROUNDING CONDUCTOR FOR THE
 CIRCUIT THAT MAY ENERGIZE THE FRAMING. PLEASE SEE
 ARTICLE.
  
 SEE 13-606.1.ABC.1.2.3 FBC FOR REQUIREMENTS FOR
 RECESSED LIGHTING FIXTURES INSTALLED IN CEILINGS THAT
 ABUT AN ATTIC SPACE.
  
 BILL TROBAUGH
 ELECTRICAL PLANS EXAMINER
 CITY OF WEST PALM BEACH

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status N Date 2007-03-30 Cont ID  
Sent By mawillia Date 2007-03-30 Time 14:13 Rev Time 0.00
Received By mawillia Date 2007-03-30 Time 14:10 Sent To  
Notes
2007-03-30 14:18:51*****NOT REQUIRED*****
  
  
 IT APPEARS THAT THE SCOPE OF WORK IS FOR A SINGLE
 RESIDENCE LOCATED IN THIS ONE WATERMARK BUILDING.
 UNLESS THE SCOPE OF WORK AFFECTS THE COMMON AREAS ON
 THIS FLOOR, NO FIRE PLAN REVIEW WILL BE REQUIRED.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-07-05 Cont ID  
Sent By adarroug Date 2007-07-05 Time 10:09 Rev Time 0.00
Received By adarroug Date 2007-07-05 Time 10:09 Sent To  
Notes
2007-07-10 13:44:43TO "BOB"#6
2007-07-05 10:10:50WAITING FOR "BOB"

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-06-29 Cont ID  
Sent By adarroug Date 2007-06-29 Time 09:15 Rev Time 0.00
Received By adarroug Date 2007-06-29 Time 09:15 Sent To M
Notes
2007-06-29 09:15:37TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-04-03 Cont ID  
Sent By spalmer Date 2007-04-03 Time 18:24 Rev Time 0.00
Received By spalmer Date 2007-04-03 Time 18:24 Sent To M
Notes
2007-04-03 18:24:38TO TOM GORDON

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-03-30 Time   Rev Time 0.00
Received By adarroug Date 2007-03-15 Time 14:05 Sent To  
Notes
2007-03-15 14:05:29TO "BOB"#2

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2007-06-29 Cont ID  
Sent By tgordon Date 2007-06-29 Time 15:59 Rev Time 0.25
Received By tgordon Date 2007-06-29 Time 15:59 Sent To  
Notes
2007-06-29 16:00:26REVISION TO MECH. PLANS PAGE M101.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2007-04-04 Cont ID  
Sent By tgordon Date 2007-04-04 Time 11:42 Rev Time 0.45
Received By tgordon Date 2007-04-04 Time 11:42 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2007-03-19 Cont ID  
Sent By tgordon Date 2007-03-19 Time 09:46 Rev Time 0.30
Received By tgordon Date 2007-03-19 Time 09:46 Sent To  
Notes
2007-03-19 09:53:06*** DENIED ***
 1) PLEASE PROVIDE RETURN AIR FOR BEDROOM 1 AND 2, SEE
 2004 FBC/R M1602.4.
  
 2) ARCHITECT RALPH CANTIN LICENSE EXPIRED 2-28-07,
 PLEASE CORRECT.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2007-03-17 Cont ID  
Sent By pschmitz Date 2007-03-17 Time 11:41 Rev Time 0.00
Received By pschmitz Date 2007-03-17 Time 11:22 Sent To  
Notes
2007-03-17 11:27:30 
 PROVISO:
 704.5 DEAD ENDS.
 IN THE INSTALLATION OR REMOVAL OF ANY PART OF A
 DRAINAGE SYSTEM, DEAD ENDS SHALL BE PROHIBITED.
 CLEANOUT EXTENSIONS AND APPROVED FUTURE FIXTURE
 DRAINAGE PIPING SHALL NOT BE CONSIDERED AS DEAD ENDS.


Account Summary | Usage Policy | Privacy Policy