Plan Review Details - Permit 07030524
| Plan Review Stops For Permit 07030524 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-05-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-05-09 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-05-09 |
Time |
10:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-05-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-05-04 |
Time |
15:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-05-04 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2007-05-04 15:51:19 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FACFLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED, | | | FAC9B72, WWW.FLORIDABUILDING.ORG.AS DISCUSSED, THIS | | | IS IN ADDITION TO THE NOAS PROVIDED.THE FL "COVER | | | SHEET" SHOWS COMPLIANCE WITH RULE 9B72.PLEASE PROVIDE | | | TWO SETS AS REQUESTED. | | | | | | **NO RESUB FEE** | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-04-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-04-30 |
Time |
07:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-04-30 |
Time |
07:11 |
Sent To |
|
|
| Notes |
| 2007-04-30 07:18:59 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FBC2004 | | | FACFLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.)THE SHUTTER INSTALLATION SCHEDULE HAS TWO NUMBERS | | | FOR SPAN.THERE IS ONLY ONE SPAN.PLEASE REVISE. | | | | | | 2.)THE SHUTTER INSTALLATION SCHEDULE SPECIFIES 9" | | | ANCHOR SPACING, BUT THIS IS ONLY FOR OPENINGS UP TO 5.5 | | | FEET.CONFLICTING INFORMATION IS PROVIDED ON THE | | | INSTALLATION SCHEDULE, SPANS NOT CLEAR. | | | | | | 3.)TWO NUMBERS WERE PROVIDED FOR THE SHUTTER GLASS | | | SEPARATION.ONLY ONE NUMBER IS POSSIBLE. | | | | | | 4.)3" MINIMUM EDGE DISTANCE IS SPECIFIED, BUT YOU'VE | | | USED THE 2.5" EDGE DISTANCE CHART. | | | | | | 5.)TWO SETS OF ALL PERMIT DOCUMENTS REQUIRED. | | | | | | 6.)THREE DIFFERENT PRODUCT APPROVALS SUBMITTED FOR | | | JELD WEN.PLEASE SUBMIT ONLY THE PRODUCT YOU ARE | | | INSTALLING AND REMOVE THE UNNECESSARY PAPERWORK. | | | PROVIDE THIS PRODUCT APPROVAL ON STANDARD PAPER | | | (NEWSPRINT WAS PROVIDED, DOES NOT GO THROUGH THE | | | SCANNING MACHINE). | | | | | | 7.)FLORIDA STATE OR LOCAL PRODUCT APPROVAL REQUIRED | | | IN ADDITION TO THE NOAS SUBMITTED, FAC9B72. | | | WWW.FLORIDABUILDING.ORG |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-03-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-03-24 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-03-24 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2007-03-24 14:45:53 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBC FLORIDA BUILDING CODE 2004 | | | FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* CITY | | | OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | | | | 1.)COMPLETE THE ATTACHED INSTALLATION SCHEDULE OR | | | PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN | | | ANOTHER FORMAT. | | | | | | 2.)PROVIDE A FLOOR PLAN SHOWING WHERE THE SHUTTERS | | | WILL BE INSTALLED AND PANEL SIZES WHICH CORRELATES WITH | | | THE INSTALLATION SCHEDULE, ITEM 4 ABOVE. | | | | | | 3.)PROVIDE A FLOOR PLAN SHOWING: WINDOW LOCATIONS, | | | SIZES, WINDOW TYPE, ROOM DESIGNATIONS.NOTE EXISTING | | | CONDITIONS (TYPE OF WINDOW) AND OPENING SIZE FOR | | | BEDROOMS, FBC R310, FBC EB 505.1. | | | | | | 4.)PROVIDE COMPLETE PRODUCT APPROVALS FOR THE | | | SHUTTERS. | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-05-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-08 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-08 |
Time |
14:08 |
Sent To |
B |
|
| Notes |
| 2007-05-08 14:09:28 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-05-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-05-03 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-05-03 |
Time |
09:58 |
Sent To |
B |
|
| Notes |
| 2007-05-03 09:58:50 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-04-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-23 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-23 |
Time |
11:43 |
Sent To |
B |
|
| Notes |
| 2007-04-23 11:43:26 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-03-24 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-03-24 |
Time |
14:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-03-15 |
Time |
14:00 |
Sent To |
|
|
| Notes |
| 2007-03-15 14:01:07 | TO "MISC" BOX#1 |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |