Plan Review Details - Permit 07030491
| Plan Review Stops For Permit 07030491 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
6 |
Status |
P |
Date |
2008-07-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-07-25 |
Time |
08:15 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2008-07-25 |
Time |
08:15 |
Sent To |
PC |
|
| Notes |
| 2008-07-25 08:16:41 | BILCO HATCH APPROVAL FOR A S-20 ROOF HATCH |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2008-05-12 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2008-05-12 |
Time |
15:57 |
Rev Time |
0.77 |
| Received By |
jwitmer |
Date |
2008-05-12 |
Time |
15:57 |
Sent To |
|
|
| Notes |
| 2008-05-12 15:58:05 | REV# 2 REVISED CONDENSING UNIT CURB |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-11-19 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-11-19 |
Time |
16:41 |
Rev Time |
2.22 |
| Received By |
jwitmer |
Date |
2007-11-19 |
Time |
16:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-09-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-09-21 |
Time |
17:07 |
Rev Time |
3.33 |
| Received By |
jwitmer |
Date |
2007-09-21 |
Time |
17:07 |
Sent To |
|
|
| Notes |
| 2007-09-21 17:10:06 | WALGREENS STORE # 7265 | | | | | | BUILDING PLAN REVIEW | | | PERMIT: 07030491 | | | ADD: 9921 OKEECHOBEE BLVD | | | CONT: ROCKWELL DEVELOPMENT | | | TEL: (561)278-3100 | | | | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 3RDREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | 2) SECOND REQUEST FOR A NOTICE OF COMMENCEMENT, | | | RESPONSE INDICATED A NOC WAS SUBMITTED, ONLY DOCUMENT | | | SIMILAR IN FORM FOUND WAS A WARRANTY DEED. FL S S | | | 713.13NOTICE OF COMMENCEMENT, TO BE FILED WITH THE | | | CLERK OF THE COURT.NOTE: 713.13(2) IF THE WORK | | | DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3-18) COMPLIED | | | | | | 19A) THIRD REQUEST,, NO PERMIT SHALL BE ISSUED WITHOUT | | | COMPLYING WITH THESE PROVISIONS, PROVIDE FIRE SPRINKLER | | | PLANS, 903.2.6 GROUP M. | | | AN AUTOMATIC SPRINKLER SYSTEM SHALL BE PROVIDED | | | THROUGHOUT BUILDINGS CONTAINING A GROUP M OCCUPANCY | | | WHERE ONE OF THE FOLLOWING CONDITIONS EXISTS: | | | 1.WHERE A GROUP M FIRE AREA EXCEEDS 12,000 SQUARE | | | FEET (1115 M 2 ). | | | TABLE 503 AND 504.2. | | | | | | 19B) 106.3.5 MINIMUM PLAN REVIEW CRITERIA FOR | | | BUILDINGS(5) FIRE SUPRESSION SYSTEMS SHALL INCLUDE | | | PREENGINEERED SYSTEMS , FIRE SPRINKLER SYSTEMS. | | | | | | 19C) NOTE!!! SEE ATTACHED FL S S 553.80(2)(B) LOCAL | | | GOVERNMENT SHALL IMPOSE EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION A | | | FEE OF FOUR TIMES THE AMOUNT OF THE PORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLAN REVIEW. | | | | | | 20)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, | | | IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. THE | | | ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | EL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-06-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-06-29 |
Time |
10:57 |
Rev Time |
4.00 |
| Received By |
jwitmer |
Date |
2007-06-29 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2007-06-29 10:59:04 | WALGREENS STORE # 7265 | | | | | | BUILDING PLAN REVIEW | | | PERMIT: 07030491 | | | ADD: 9921 OKEECHOBEE BLVD | | | CONT: ROCKWELL DEVELOPMENT | | | TEL: (561)278-3100 | | | | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | 2NDREVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & | | | REMOVE & REPLACE ANY PAGES AS NECESSARY. A TRANSMITTAL | | | LETTER LISTING THE ORIGINAL REVIEW COMMENT NUMBER, WITH | | | A DESCRIPTION OF THE REVISION MADE, IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGES CAN BE | | | FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | 2) SECOND REQUEST FOR A NOTICE OF COMMENCEMENT, | | | RESPONSE INDICATED A NOC WAS SUBMITTED, ONLY DOCUMENT | | | SIMILAR IN FORM FOUND WAS A WARRANTY DEED. FL S S | | | 713.13NOTICE OF COMMENCEMENT, TO BE FILED WITH THE | | | CLERK OF THE COURT.NOTE: 713.13(2) IF THE WORK | | | DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS NOT | | | ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE RECORDING | | | THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6) | | | THE POSTING OF THE NOTICE OF COMMENCEMENT AT THE | | | CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3) SECOND REQUEST, IS FOR SOILS REPORT, SUBMITTED IS | | | COPIESNOT ORIGINAL SIGNED AND SEALED DOCUMENTS. SHEET | | | S5.1 SITE WORK# 2 ALSO REQUIRES A SOILS INVESTIGATIVE | | | REPORT BY A LICENSED GEOTECHNICAL ENGINEER.1802.2.1 | | | QUESTIONABLE SOIL. | | | WHERE THE SAFE-SUSTAINING POWER OF THE SOIL IS IN | | | DOUBT, OR WHERE A LOAD-BEARING VALUE SUPERIOR TO THAT | | | SPECIFIED IN THIS CODE IS CLAIMED, THE BUILDING | | | OFFICIAL SHALL REQUIRE THAT THE NECESSARY INVESTIGATION | | | BE MADE. SUCH INVESTIGATION SHALL COMPLY WITH THE | | | PROVISIONS OF SECTIONS 1802.4 THROUGH 1802.6 . | | | | | | 4) COMPLIED. | | | | | | 5) BUILDING PROVISO: 109.3.10* IMPACT OF CONSTRUCTION. | | | ALL CONSTRUCTION ACTIVITY REGULATED BY THIS CODE SHALL | | | BE PERFORMED IN A MANNER SO AS NOT TO ADVERSELY IMPACT | | | THE CONDITION OF ADJACENTPROPERTY, UNLESS SUCH | | | ACTIVITY IS PERMITTED TO AFFECT SAID PROPERTY PURSUANT | | | TO A CONSENT BY THE APPLICABLE PROPERTY OWNER, UNDER | | | TERMS & CONDITIONS AGREEABLE TO THE APPLICABLE PROPERTY | | | OWNER. THIS INCLUDES BUT IS NOT LIMITED TO THE CONTROL | | | OF DUST, NOISE, WATER OR DRAINAGE RUN-OFF, DEBRIS, AND | | | THE STORAGE OF CONSTRUCTION MATERIALS. NEW CONSTRUCTION | | | ACTIVITY SHALL NOT ADVERSELY IMPACT HISTORIC SURFACE | | | WATER DRAINAGE FLOWS SERVING ADJACENT PROPERTIES, & MAY | | | REQUIRE SPECIAL DRAINAGE DESIGN COMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE POSITIVE PATTERNS | | | OF THE AFFECTED SITES. ACCORDINGLY, DEVELOPERS, | | | CONTRACTORS, AND OWNERS OF ALL NEW RESIDENTIAL | | | DEVELOPMENT, INCLUDING ADDITIONS, POOLS, PATIOS, | | | DRIVEWAYS, DECKS, OR SIMILAR ITEMS, ON EXISTING | | | PROPERTIES RESULTING IN A DECREASE IN EXCESS OF 800SQ | | | FT OF PERMEABLE LAND AREA ON ANY PARCEL SHALL AS A | | | PERMIT CONDITION, PROVIDE A PROFESSIONALLY PREPARED | | | DRAINAGE PLAN CLEARLY INDICATING COMPLIANCE WITH THIS | | | PARAGRAPH. UPON COMPLETION OF THE IMPROVEMENT, A | | | CERTIFICATE FROM A LICENSED ENGINEER SHALL BE SUBMITTED | | | TO THE INSPECTOR IN ORDER TO RECEIVE APPROVAL OF THE | | | FINAL INSPECTION. | | | | | | 6) BUILDING PROVISO:109.3.10.1 HURRICANE PROTECTION. | | | IT SHALL BE UNLAWFUL FOR ANY PERSON TO | | | ALLOW CONSTRUCTION RELATED MATERIALS EQUIPMENT AND | | | DEBRIS TO REMAIN LOOSE OR OTHERWISE UNSECURED AT A | | | CONSTRUCTION SITE FROM 24 HRS. AFTER A HURRICANE WATCH | | | HAS BEEN ISSUED UNTIL THE HURRICANE WATCH OR WARNING | | | HAS BEEN LIFTED. ALL SUCH CONSTRUCTION MATERIALS, | | | EQUIPMENT AND DEBRIS SHALL BE EITHER REMOVED FROM THE | | | CONSTRUCTION SITE OR SECURED IN SUCH A MANNER AS TO | | | MINIMIZE THE DANGER OF SUCH CONSTRUCTION MATERIALS, | | | EQUIPMENT AND DEBRIS CAUSING DAMAGE TO PERSONS OR | | | PROPERTY FROM HIGH WINDS. ANY PERSONS WHO FAILS TO | | | COMPLY TO REMOVE OR SECURE THE CONSTRUCTION MATERIALS | | | EQUIPMENT AND DEBRIS WITHIN 24 HRS AFTER A HURRICANE | | | WATCH HAS BEEN ISSUED SHALL BE SUBJECT TO A FINE NOT TO | | | EXCEED $500.00. IN ADDITION TO THE ABOVE, A LICENSED | | | CONTRACTOR WHO VIOLATES THIS SECTION SHALL BE SUBJECT | | | TO DISCIPLINE PURSUANT TO SECTION 113 OF THIS CHAPTER. | | | | | | 7-10 COMPLIED. | | | | | | 11) SECOND REQUEST, IT APPEARS THAT THE CONTRACTOR IS | | | TRYING TO COMPLY WITH THIS REQUEST FOR PRODUCT | | | APPROVALS REQUIRED BY RULE 9B-72, THE CONTRACTOR DID | | | SUPPLY THE FLORIDA COVER SHEETS THAT INDICATE TESTING | | | WAS COMPLETED AND COMPLIES WITH THE STANDARD. WE ALSO | | | NEED THE TEST REPORTS WITH THE TECHNICAL DRAWINGS (NOT | | | SHOP DRAWINGS) THAT WERE ALSO SUBMITTED TO THE STATE | | | FOR APPROVAL. THE PRODUCT APPROVALS WILL PROVIDE TO | | | WHAT PRESSURES THE COMPONENTS WERE TESTED TO, WHAT | | | LIMITATIONS ARE IMPOSED, AND THE CALCULATIONS WILL | | | DETERMINE TO WHICH CODE THE TEST WAS COMPLETED TO. | | | PLEASE SUBMIT THE TEST REPORTS, MOST WILL BE A | | | MIAMI-DADE APPROVAL BUT NOT NECESSARILY SO. AS LONG AS | | | YOU TAKE THE ATTACHED PDF FILE FROM THE FLORIDA | | | WEBSITE!!!! FLORIDABUILDING.ORG. | | | FL BLD CODE 1609.1.4: COMPONENTS & | | | CLADDING, PROVIDE 2 COPIES (3 IF THRESHOLD OR RESIDENT | | | INSPECTOR) OF PRODUCT TESTING REPORTS ,MISSING REPORTS | | | ARE AS FOLLOWS: | | | A) EXTERIOR HOLLOW METAL SWING DOORS | | | B) OVERHEAD COIL DOORS | | | C) AUTOMATIC SLIDING DOORS | | | D) ROOF HATCHES | | | E) WINDOWS- STOREFRONT | | | F) WINDOWS- PASS THROUGH | | | G) ROOF ASSEMBLIES: FLAT ROOF AND SLOPED TILE ROOF H) | | | PRE-MANUFACTURED A/C STANDS | | | ***SHEET A4.5 STILL INDICATES SLEEPERS, SEE 1509.7 | | | & TABLE 1509.7*** | | | I ) WOOD OR TRUSS TIE DOWN ANCHORS | | | | | | 12) SECOND REQUEST,ADMIN CODE 106.3* PRODUCT | | | APPROVALS. THOSE PRODUCT WHICH ARE REGULATED BY DCA | | | RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN WRITING BY | | | THE DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | 13) SEMI- COMPLIED, THE CONTRACTOR HAS MEET THIS | | | REQUIREMENT BUT NEEDS TO SUPPLY THE BACK UP | | | DOCUMENTATION. | | | | | | 14)2ND REQUEST,) THIS ROOF IS MISSING OR NOT IN | | | COMPLIANCE WITH THE FOLLOW ITEMS: | | | | | | ___ CONTRACTOR DID NOT PROVIDE THE MEAN ROOF HEIGHT. | | | | | | ___ CONTRACTOR DID NOT INDICATE THE ROOF PITCH. | | | | | | _XX__ CONTRACTOR FAILED TO INDICATE WHICH SYSTEM TO BE | | | USED. | | | | | | _XX__ THE SYSTEM PROVIDED HAS A LOW PRESSURE FOR ZONE | | | _2&3__ . | | | | | | _XX__ THE SYSTEM PROVIDED STATES LIMITATION# 7, SHOULD | | | THE FASTENER RESISTANCE BE LESS THAN THAT | | | REQUIRED, AS DETERMINED BY THE BUILDING OFFICIAL, A | | | REVISED FASTENER SPACING, PREPARED , SIGNED | | | AND SEALED BY A FLORIDA REGISTERED PROFESSIONAL | | | ENGINEER, REGISTERED ARCHITECT OR REGISTERED ROOF | | | CONSULTANT MAY BE SUBMITTED. | | | | | | ___THE SYSTEM PROVIDED INDICATES LIMITATION# 9, NO | | | ENHANCED FASTENING ALLOWED. | | | | | | 15) COMPLIED. | | | | | | 16) COMPLIED. | | | | | | 17) SHEET A2.4 HAS BEEN REVISED FOR THE CANOPY CEILING | | | INSTALLATION TO SHOW THE USE OF WIRE LATH, | | | TYPE OF WIRE LATH IS NOT SPECIFIED, PLEASE SEE 2510.3 | | | INSTALLATION FOR STUCCO REFERS TO ASTM C 1063. ASTM C | | | 1063 TABLE 3 PROVIDES TYPES OF LATH, THE WEIGHT OF | | | LATH, VERTICAL AND HORIZONTAL | | | APPLICATIONS AND THE SPACING OF SUPPORTS. THE STANDARD | | | ALSO PROVIDES THE LENGTH OF FASTENER REQUIREMENTS | | | PLEASE PROVIDE. | | | | | | 18) 2ND REQUEST, THE REQUIREMENT FOR ATTIC VENTILATION | | | STILL REMAINS,1203.2 ATTIC SPACES. | | | ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE | | | CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF | | | FRAMING MEMBERS SHALL HAVE CROSS VENTILATION FOR EACH | | | SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED | | | AGAINST THE ENTRANCE OF RAIN. BLOCKING AND BRIDGING | | | SHALL BE ARRANGED SO AS NOT TO INTERFERE WITH THE | | | MOVEMENT OF AIR. A MINIMUM OF 1 INCH (25 MM) OF | | | AIRSPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND | | | THE ROOF SHEATHING. THE NET FREE VENTILATING AREA SHALL | | | NOT BE LESS THAN 1 / 150 OF THE AREA OF THE SPACE | | | VENTILATED, WITH 50 PERCENT OF THE REQUIRED VENTILATING | | | AREA PROVIDED BY VENTILATORS LOCATED IN THE UPPER | | | PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3 FEET | | | (914 MM) ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE | | | OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE | | | VENTS. | | | | | | 19) SECOND REQUEST, PROVIDE FIRE SPRINKLER PLANS, | | | 903.2.6 GROUP M. | | | AN AUTOMATIC SPRINKLER SYSTEM SHALL BE PROVIDED | | | THROUGHOUT BUILDINGS CONTAINING A GROUP M OCCUPANCY | | | WHERE ONE OF THE FOLLOWING CONDITIONS EXISTS: | | | 1.WHERE A GROUP M FIRE AREA EXCEEDS 12,000 SQUARE | | | FEET (1115 M 2 ). | | | TABLE 503 AND 504.2. | | | | | | 20)BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, | | | IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. THE | | | ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | BUILDING PLAN REVIEW II | | | JIM WITMER C. B. O. | | | EL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-04-13 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2007-04-13 |
Time |
15:22 |
Rev Time |
12.55 |
| Received By |
jwitmer |
Date |
2007-04-13 |
Time |
15:22 |
Sent To |
FIRE |
|
| Notes |
| 2007-04-13 15:26:25 | BUILDING PLAN REVIEW | | | PERMIT: 07030491 | | | ADD: 9921 OKEECHOBEE BLVD | | | CONT: ROCKWELL DEVELOPMENT | | | TEL: (561)278-3100 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2 ) FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF | | | THE COURT. | | | NOTE: 713.13(2) IF THE WORK DESCRIBED IN THE NOTICE OF | | | COMMENCEMENT | | | IS NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE | | | RECORDING THEREOF, | | | SUCH NOTICE IS NULL & VOID. NOTE: 713.13(6)THE | | | POSTING OF THE NOTICE OF | | | COMMENCEMENT AT THE CONSTRUCTION SITE BEFORE THE FIRST | | | INSPECTION. | | | | | | 3) FBC 1802.2.1 QUESTIONABLE SOILS, | | | 1802.2.1 QUESTIONABLE SOIL. WHERE THE SAFE-SUSTAINING | | | POWER OF THE SOIL IS | | | IN DOUBT, OR WHERE A LOAD-BEARING VALUE SUPERIOR TO | | | THAT SPECIFIED IN THIS CODE | | | IS CLAIMED, THE BUILDING OFFICIAL SHALL REQUIRE THAT | | | THE NECESSARY INVESTIGATION BE | | | MADE. SUCH INVESTIGATION SHALL COMPLY WITH THE | | | PROVISIONS OF | | | SECTIONS 1802.4 THROUGH 1802.6 . | | | | | | 4)106.1.2 * ADDITIONAL INFORMATION REQUIRED, PLANS | | | FAIL TO PROVIDE AN INDEX INDICATING | | | ON WHICH SHEET ANY CERTAIN DOCUMENT WILL BE FOUND. THIS | | | WOULD GREATLY INCREASE PRODUCTIVITY | | | IN THE AMOUNT OF TIME IT TAKES TO DO A REVIEW OF YOUR | | | PROJECT!!!! | | | | | | 5) 109.3.10* IMPACT OF CONSTRUCTION. | | | ALL CONSTRUCTION ACTIVITY REGULATED BY | | | THIS CODE SHALL BE PERMORMED IN A MANNER | | | SO AS NOT TO ADVERSELY IMPACT THE | | | CONDITION OF ADJACENT PROPERTY, UNLESS | | | SUCH ACTIVITY IS PERMITTED TO AFFECT | | | SAID PROPERTY PURSUANT TO A CONSENT BY | | | THE APPLICABLE PROPERTY OWNER, UNDER | | | TERMS & CONDITIONS AGREEABLE TO THE | | | APPLICABLE PROPERTY OWNER.THIS INCLUDES | | | BUT IS NOT LIMITED TO THE CONTROL OF | | | DUST, NOISE, WATER OR DRAINAGE RUN-OFF, | | | DEBRIS, AND THE STORAGE OF CONSTRUCTION | | | MATERIALS. NEW CONSTRUCTION ACTIVITY | | | SHALL NOT ADVERSELY IMPACT HISTORIC | | | SURFACE WATER DRAINAGE FLOWS SERVING | | | ADJACENT PROPERTIES, & MAY REQUIRE | | | SPECIAL DRAINAGE DESIGN COMPLYING WITH | | | ENGINEERING STANDARDS TO PRESERVE THE | | | POSITIVE PATTERNS OF THE AFFECTED SITES. ACCORDINGLY, | | | DEVELOPERS, CONTRACTORS, | | | AND OWNERS OF ALL NEW RESIDENTIAL | | | DEVELOPMENT, INCLUDING ADDITIONS, POOLS, | | | PATIOS, DRIVEWAYS, DECKS, OR SIMILAR | | | ITEMS, ON EXISTING PROPERTIES RESULTING | | | IN A DECREASE IN EXCESS OF 800SQ FT OF | | | PERMEABLE LAND AREA ON ANY PARCELL SHALL | | | AS A PERMIT CONDITION, PROVIDE A | | | PROFESSIONALLY PREPARED DRAINAGE PLAN | | | CLEARLY INDICATING COMPLIANCE WITH THIS | | | PARAGRAPH. UPON COMPLETION OF THE | | | IMPROVEMENT, A CERTIFICATE FROM A | | | LICENSED ENGINEER SHALL BE SUBMITTED TO | | | THE INSPECTOR IN ORDER TO RECEIVE | | | APPROVAL OF THE FINAL INSPECTION. | | | | | | 6) 109.3.10.1 HURICANE PROTECTION. | | | IT SHALL BE UNLAWFUL FOR ANY PERSON TO | | | ALLOW CONSTRUCTION RELATED MATERIALS | | | EQUIPMENT AND DEBRIS TO REMAIN LOOSE OR | | | OTHERWISE UNSECURED AT A CONSTRUCTION | | | SITE FROM 24 HRS. AFTER A HURRICANE | | | WATCH HAS BEEN ISSUED UNTIL THE | | | HURRICANE WATCH OR WARNING HAS BEEN | | | LIFTED. ALL SUCH CONSTRUCTION MATERIALS, | | | EQUIPMENT AND DEBRIS SHALL BE EITHER | | | REMOVED FROM THE CONSTRUCTION SITE OR | | | SECURED IN SUCH A MANNER AS TO MINIMIZE | | | THE DANGER OF SUCH CONSTRUCTION | | | MATERIALS, EQUIPMENT AND DEBRIS CAUSING | | | DAMAGE TO PERSONS OR PROPERTY FROM HIGH | | | WINDS. | | | ANY PERSONS WHO FAILS TO COMPLY TO | | | REMOVE OR SECURE THE CONSTRUCTION | | | MATERIALS EQUIPMENT AND DEBRIS WITHIN | | | 24 HRS AFTER A HURRICANE WATCH HAS BEEN | | | ISSUED SHALL BE SUBJECT TO A FINE NOT TO | | | EXCEED $500.00. | | | IN ADDITION TO THE ABOVE, A LICENSED | | | CONTRACTOR WHO VIOLATES THIS SECTION | | | SHALL BE SUBJECT TO DISCIPLINE PURSUANT | | | TO SECTION 113 OF THIS CHAPTER. | | | | | | 7)SHEET A0.1 INDICATES THE PLANS WERE DESINED TO THE | | | 2004 FBC. PLANAS SUBMITTED AFTER DEC.8, 2006 ARE TO BE | | | DESIGNED TO THE 2004FBC WITH THE 2006 AMENDMENTS. | | | | | | 8)SHEET A0.2 SITE PLAN INDICATES WHAT APPEARS TO BE A | | | PROPERTY LINE AROUND THE NEW PROPOSED STORE, BUT THERE | | | ALSO APPEARS TO BE A SECOND PROPERTY LINE AT THE FRONT | | | OF THE STORE? WHAT AREA IS THE LEASABLE AREA OR | | | PROPERTY LINE ? IS THERE ONLY 38 PARKING SPACES IN THIS | | | PROJECT OR IS THERE 87 PARKING SPACES? IF THERE ARE 87 | | | PARKING SPACES THEN 11-4.1.2(5)(A)INDICATES THERE | | | SHOULD BE (4) SPACES FOR THE PHYSICLLY DISABLED . | | | | | | 9) SURVEY BY CRAIG S. PUSEY IS A RAISED SEAL BUT PHOT | | | COPIED SIGNATURE. | | | | | | 10)) SHEET A0.2 ALSO SHOULD SHOW THE ACCESSABLE ROUTE | | | TO THE PUBLIC WAY. 11-4.1.2(1) . | | | | | | 11)FL BLD CODE 1609.1.4: COMPONENTS & CLADDING, | | | PROVIDE 2 COPIES(3 IF THRESHOLD OR RESIDENT INSPECTOR) | | | OF PRODUCT | | | TESTING REPORTS,MISSING REPORTS ARE AS FOLLOWS:A) | | | EXTERIOR HOLLOW METAL SWING DOORS | | | B)OVERHEAD COIL DOORS | | | C) AUTOMATIC SLIDING DOORS | | | D) ROOF HATCHES | | | E) WINDOWS- STOREFRONT | | | F) WINDOWS PASS THROUGH | | | G) ROOF ASSEMBLIES, BASE SHEETS, TILE AND FASTENER | | | TYPES | | | H) PRE-MANUFACTURED A/C STANDSSHEET A4.5INDICATES | | | SLEEPERS, 1509.7/ TABLE 1509.7. | | | I) WOOD TRUSS TIE DOWN ANCHORS | | | | | | 12)PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. | | | | | | | | | 13) PRODUCTS WITH STATEWIDE APPROVAL ARE REQUIRED TO | | | BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. IF THE PRODUCT DOES NOT HAVE | | | STATEWIDE APPROVAL, SUBMIT AN APPLICA- | | | TION FOR LOCAL PRODUCT APPROVAL OR SITE | | | SPECIFIC FORM PER RULE 9B-72. SEE | | | ATTACHMENT. WWW.FLORIDABUILDING.ORG | | | | | | 14) THIS ROOF IS MISSING OR NOT IN | | | COMPLIANCE WITH THE FOLLOW ITEMS: | | | ROOF TILE : | | | _X__ CONTRACTOR DID NOT PROVIDE THE MEAN | | | | | | ROOF HEIGHT. | | | | | | ___ CONTRACTOR DID NOT INDICATE THE ROOF | | | PITCH. | | | | | | _X__ CONTRACTOR FAILED TO INDICATE WHICH | | | SYSTEM TO BE USED. | | | | | | __X_ THE SYSTEM PROVIDED HAS A LOW | | | PRESSURE FOR ZONE _2&3__ . | | | | | | __X_ THE SYSTEM PROVIDED STATES | | | LIMITATION# 7, SHOULD THE FASTENER | | | RESISTANCE BE LESS THAN THAT | | | REQUIRED, AS DETERMINED BY THE | | | BUILDING OFFICIAL, A REVISED | | | FASTENER SPACING, PREPARED , SIGNED | | | AND SEALED BY A FLORIDA REGISTERED | | | PROFESSIONAL ENGINEER, REGISTERED | | | ARCHITECT OR REGISTERED ROOF | | | CONSULTANT MAY BE SUBMITTED. | | | | | | _X__THE SYSTEM PROVIDED INDICATES | | | LIMITATION# 9, NO ENHANCED | | | FASTENING ALLOWED. | | | | | | __X__- PROVIDE TYPE OF RIDGE AND HIP BOARD TO BE USED | | | AND TYPE OF ATACHMENT. | | | CONCRETE TILE / CLAY TILEATTACHMENTSHALL BE | | | FASTENED IN ACCORDANCE WITH 1609 OR IN ACCORDANCE WITH | | | FRSA/TRI 07320-04 INSTALLATION MANUAL. | | | | | | 15) SHEET S2.1 TRUSS TIE DOWNANCHORS, THE DESIGNER OF | | | RECORD HASN,T GIVEN THE VALUES REQUIRED FOR THE HOLD | | | DOWN FASTENERS.PLEASE PROVIDE GRAVITY LOADS, LATERAL | | | LOADS & UPLIFT LOADS TO BE RESISTED.THE ANCHORS ARE | | | PART OF THE MAIN FORCE RESISTING SYSTEM1609.1.1. PLEASE | | | PROVIDE VALUES TO BE RESISTED.T1 & T2 ARE NOT LOCATED | | | ON PLAN. | | | | | | 16)FRONT ENTRY HORIZONTAL SLIDING DOORS: 1008.1.3.3 | | | HORIZONTAL SLIDING DOORS. | | | IN OTHER THAN GROUP H OCCUPANCIES, HORIZONTAL SLIDING | | | DOORS PERMITTED TO BE A COMPONENT OF A MEANS OF EGRESS | | | IN ACCORDANCE WITH EXCEPTION 5 TO SECTION 1008.1.2 | | | SHALL COMPLY WITH ALL OF THE FOLLOWING CRITERIA: 1. | | | THE DOORS SHALL BE POWER OPERATED AND SHALL BE CAPABLE | | | OF BEING OPERATED MANUALLY IN THE EVENT OF POWER | | | FAILURE. | | | 2.THE DOORS SHALL BE OPENABLE BY A SIMPLE METHOD | | | FROM BOTH SIDES WITHOUT SPECIAL KNOWLEDGE OR EFFORT. 3. | | | THE FORCE REQUIRED TO OPERA TE THE DOOR SHALL NOT | | | EXCEED 30 POUNDS (133 N) TO SET THE DOOR IN MOTION AND | | | 15 POUNDS (67 N) TO CLOSE THE DOOR OR OPEN IT TO THE | | | MINIMUM REQUIRED WIDTH. | | | 4.THE DOOR SHALL BE OPENABLE WITH A FORCE NOT TO | | | EXCEED 15 POUNDS (67 N) WHEN A FORCE OF 250 POUNDS | | | (1100 N) IS APPLIED PERPENDICULAR TO THE DOOR ADJACENT | | | TO THE OPERATING DEVICE. | | | 5.THE DOOR ASSEMBLY SHALL COMPLY WITH THE | | | APPLICABLE FIRE PROTECTION RATING AND, WHERE RATED, | | | SHALL BE SELF-CLOSING OR AUTOMATIC-CLOSING BY SMOKE | | | DETECTION, SHALL BE INSTALLED IN ACCORDANCE WITH NFPA | | | 80 AND SHALL COMPLY WITH SECTION 715 . | | | 6.THE DOOR ASSEMBLY SHALL HAVE AN INTEGRATED | | | STANDBY POWER SUPPLY. | | | 7.THE DOOR ASSEMBLY POWER SUPPLY SHALL BE | | | ELECTRICALLY SUPERVISED. | | | 8.THE DOOR SHALL OPEN TO THE MINIMUM REQUIRED | | | WIDTH WITHIN 10 SECONDS AFTER ACTIVATION OF THE | | | OPERATING DEVICE. | | | 9.IN APARTMENT BUILDINGS, HOTELS AND DORMITORIES, | | | HORIZONTAL SLIDING DOORS SHALL NOT BE USED ACROSS | | | CORRIDORS. | | | | | | 17)A2.4 INDICATES THE USE OF HI-RIB LATH ON THE UNDER | | | SIDE (HORIZONTAL FRAMING MEMBERS) OF THE CANOPY, PLEASE | | | PROVIDE THE NAILING REQUIREMENTS FOR LATH. TABLE | | | 2511.1/ ASTM | | | C-1063. 2504.2.2 INSTALLATION OF EXTERIOR | | | LATHING AND FRAMING SHALL COMPLY WITH | | | ASTM C-1063. | | | | | | 18)SHEET A2.4 INDICATES THE USE OF EAVE ANDTHE | | | MONIER LIFETILE ATTIC VENT, PLEAS PROVIDE THE | | | CALCULATIONS AS PER 1203.2, PLEASE ALSO PROVIDE THE | | | PRODUCT APPROVAL | | | FOR THE LIFETILE ATTIC VENT, RULE 9-B-72. | | | | | | 19)PLEASE PROVIDE THE FIRE SPRINKLER PLANS SHEET A0.1 | | | PROJECT INFORMATION INDICATES TAKING AREA INCREASES FOR | | | A FIRE SPRINKLERED BUILDING, PLEASE PROVIDETHE | | | REQUIREDAUTOMATIC SPRINKLER PLANS PER, TABLE 503, | | | 504.2 & 903.1.1 | | | | | | 20)BEFORE A PERMIT TO CONSTRUCT, MAY | | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | | SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT | | | ATTACHED TO THE PERMIT APPLICATION. | | | PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | BUILDING PLAN REVIEW | | | JIM WITMER C. B. O. | | | | | | TEL: (561)805-6715 | | | FAX: (561)659-8026 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-09-11 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-09-11 |
Time |
17:29 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-09-11 |
Time |
17:29 |
Sent To |
|
|
| Notes |
| 2007-09-11 17:30:07 | 2007-09-11 17:30:07 | | | | | | ELEC OK, STAMPED PLANS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2007-06-22 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-06-22 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-06-22 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2007-06-22 14:16:15 | *** UNSAT2ND REVIEW *** | | | | | | ** PLEASE SEE THERE ARE STILL SOME NOTES FROM PREVIOUS | | | REVIEW WHICH ARE STILL IN NEED OF ADDRESSING. | | | | | | | | | * PLEASE KNOW THAT ANY REFERENCE TO THE FBC CHAPTER 1 | | | WILL BE FROM THE ADMINISTRATIVE SECTION OF THE CODE AS | | | ADOPTED BY THE CITY OF WEST PALM BEACH. | | | | | | 1) NOTE:SAME NOTE FROM PREVIOUS REVIEW. THE RESPONSE | | | LETTER FROM ARCHITECT MENTIONS THIS WILL BE ADDRESSED | | | BY THE CONTRACTOR HOWEVER THIS IS NOT THE | | | RESPONSIBILITY OF THE CONTRACTOR. IT IS THE | | | RESPONSIBILITY OF THE DESIGNER OR FIRM AS NOTED. | | | PLEASE ALSO SEE SOME *L* SHEETS IN SETS WHICH ARE NOTE | | | SIGNED, DATED OR SEALED. | | | PLEASE SEE MISSING LICENSE NUMBER FOR THE LANDSCAPE | | | FIRM AS LISTED ON THE TITLE BLOCKS FOR *L* SHEETS. THIS | | | IS ALSO KNOWN AS THE CERTIFICATE OF AUTHORIZATION | | | NUMBER. | | | PLEASE SEE 481.219, FAC 61G1-16.004 | | | THIS IS REQUIRED WHETHER OR NOT COMMENT IS MADE BY | | | OTHER TRADES. | | | | | | 2) NOTE:SAME NOTE AS PREVIOUS REVIEW. THE RESPONSE | | | LETTER FROM ARCHITECT MENTIONS THIS WILL BE ADDRESSED | | | BY THE CONTRACTOR HOWEVER THIS IS NOT THE | | | RESPONSIBILITY OF THE CONTRACTOR. IT IS THE | | | RESPONSIBILITY OF THE DESIGNER OR FIRM AS NOTED PLEASE | | | SEE THE MISSING LICENSE NUMBER FOR THE SURVEY FIRM AS | | | REQUIRED PER FS 472.021. 61G17 | | | ALSO KNOWN AS THE CERTIFICATE OF AUTHORIZATION NUMBER. | | | | | | 3) NOTE:PLEASE SEE THIS COMMENT REMAINS AS THE PLANS | | | NOW INDICATE A 2005 NFPA-72 WHICH IS NOT YET ADOPTED BY | | | THE STATE OF FLORIDA. PLEASE SEE THE PREVIOUS REVIEW | | | NOTES BELOW WHICH GIVE THE CODES TO BE ON PLANS. PLEASE | | | SEE THERE ARE STILL LOCATIONS ON PLANS ON SHEETS WHICH | | | WERE NOTE CHANGED OUT WHICH REFLECT THE *STANDARD | | | BUILDING CODE*. | | | ** PREVIOUS REVIEW NOTE* | | | PLEASE SEE THAT ALL OF THE CODES WHICH PLANS ARE UNDER | | | DESIGN AND RECORD SHALL BE STATED ON PLANS AS FOLLOWS. | | | PLEASE SEE THAT THERE ARE SEVERAL LOCATIONS WHICH CODES | | | FROM OLDER ADOPTED CODES ARE STATED ON PLANS. PLEASE | | | ALSO SEE THAT THE PLANS ALSO CONTAIN STATEMENTS IN | | | DIFFERENT LOCATIONS FOR THE *STANDARD BUILDING *. | | | PLEASE KNOW THAT THE STANDARD BUILDING CODE WAS NO | | | LONGER IN AFFECT AS OF MARCH 1ST, 2002 WHEN THE STATE | | | OF FLORIDA ADOPTED THE 2001 FBC. | | | PLEASE KNOW THAT AS OF DECEMBER 8TH, 2006 THE FOLLOWING | | | CODE(S) WERE ADOPTED. PLEASE LIST THE FOLLOWING AT A | | | MINIMUM FOR THIS REVIEWER. | | | 2004 FBC W/ 2006 REVISIONS. | | | 2005 NFPA-70 | | | 2003 NFPA-101 | | | 2002 NFPA-72 | | | | | | ** THESE ARE REQUIRED FOR THIS REVIEWER AT A MINIMUM | | | AND OTHER CODES WILL BE REQUIRED FOR OTHER TRADES. | | | | | | 4) NOTE: PLEASE SEE THE ADDRESS FOR THIS PROJECT IS | | | 9921 OKEECHOBEE BLVD. PLEASE INCLUDE THIS INFORMATION | | | AS REQUIRED ON TITLE BLOCKS. PLEASE SEE NUMEROUS SHEETS | | | FROM PREVIOUS REVIEW NOT ONLY FOR ELECTRICAL BUT FOR | | | OTHER TRADE SHEETS AS WELL DO NOT SHOW THE ADDRESS. THE | | | LOCATION AS NOTED TO THE NEAREST MAIN INTERSECTION IS | | | NOT ACCEPTABLE. | | | THIS IS TO BE CORRECTED ON ALL SHEETS EVEN IF COMMENT | | | IS NOT MADE BY OTHER TRADE(S). PLEASE KNOW THAT SHEETS | | | WHICH MAY ALREADY CONTAIN STAMPS FROM REVIEWERS MAY | | | HAVE THE CORRECT ADDRESS PLACED ON SHEETS BY PERMANENT | | | MEANS. (PRINTED, STAMPED ETC) | | | FAC 61G1-16.004, FAC 61G15-23.002 | | | | | | 5) NOTE: PLEASE SEE 2004 FBC W/2006 REVISIONS FOR | | | CHAPTER 13. PLEASE SEE RESPONSE MENTIONS TO SEE TIMES | | | FOR OVER RIDE DEVICES ON SHEETS AND 4.1 YET THESE TIMES | | | FOR OCCUPANCY TYPE DEVICE COULD NOT BE LOCATED ON | | | PLANS. | | | PLEASE SEE THE ENERGY CALCULATION AS SUBMITTED STILL DO | | | NOT CORRELATE WITH THE FIXTURE LEGEND AND FIXTURE NOTES | | | ON THE SAME SHEET AS FIXTURE LEGEND. PLEASE SEE THE | | | NUMBER OF FIXTURE, TYPES AND WATTAGES NEED TO | | | COORDINATE WITH THE ENERGY CALCULATIONS. | | | KEYED NOTE #4 ON LIGHTING SHEETS MENTIONS TO SEE NOTE | | | #111 ON E4.1, HOWEVER THE NOTE ON E4.1 DOES NOT | | | ELABORATE ON DEVICE TIMES? | | | LIGHTING CASES? | | | 13-415.1.ABC1.1, .1.2, .1.3. | | | ** PLEASE SEE THAT THE OWNER AGENT IS NOT SIGNED ON | | | ENERGY CALCULATIONS. | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE 13-415.1.ABC.1.1, .1.2 AND .1.3.PLEASE SEE | | | SOME LOCATIONS WHICH DO NOT INDICATE ANY LIGHTING | | | CONTROLS UNDER AN AUTOMATED MEANS. PLEASE SEE THAT | | | THESE DEVICES NEED TO BE SHOWN AS SOME OF THE DEVICES | | | SHOWN SEEM TO BE NORMAL CONTROL SWITCHES AND SOME AREAS | | | DO NOT SEEM TO INDICATE OCCUPANCY TYPE DEVICES. PLEASE | | | SEE THE COOLER, FREEZER, DRIVE THRU SWITCH, TOWER | | | SWITCH, PHOTO-LAB ETC. PLEASE VERIFY ALL LOCATIONS. | | | PLEASE INDICATE THE MAXIMUM OVER RIDE TIMES, AND TIMES | | | FOR ALL DEVICES. THE PLANS DO CONTAIN SOME NOTES WHICH | | | STATE 2HRS HOWEVER NOT FOR ALL. | | | PLEASE SEE OUTSIDE LIGHTING IS REQUIRED TO BE ON AN | | | ASTRONOMICAL TIME CLOCK WITH CONTROLS TO SHUT LIGHTING | | | OFF WHEN SUFFICIENT DAY LIGHT IS PRESENT. | | | PLEASE SEE 13-415.1.ABC.3 FOR TANDEM WIRING. PLEASE SEE | | | THE LIGHTING FIXTURE LEGEND DOES NOT CORRELATE WITH THE | | | ENERGY CALCULATIONS SUBMITTED. PLEASE ALSO SEE THE | | | TOTAL WATTAGE AND MAXIMUM LIGHTING POWER DENSITIES AS | | | SHOWN CAN NOT BE VERIFIED. PLEASE SEE THAT THE LIGHTING | | | ENERGY CALCULATIONS DO NOT INDICATE THE EXTERNAL AND | | | EXTERIOR LIGHTING AS SHOWN ON PLANS. | | | PLEASE SEE THAT THE ENERGY CALCULATIONS SUBMITTED | | | INDICATES *MANUAL ON/OFF* FOR ALL LIGHTING? PLEASE SEE | | | THAT THIS IS NOT POSSIBLE WHEN THE LIGHTING IS | | | AUTOMATED. | | | PLEASE SEE THE SHEET #3 NEEDS TO CONTAIN THE | | | INFORMATION AS NEEDED FOR PRINTED INFORMATION FOR THE | | | DESIGNER OF RECORD, SIGNED, DATED AND SEAL.PLEASE BE | | | SURE ALL TO SEE 13-103.1.1.1 | | | | | | 6) NOTE:PLEASE SEE THE RESPONSE TO THIS COMMENT | | | MENTIONS TO SEE SHEETS E1.1 AND E2.1A HOWEVER PLEASE | | | CLARIFY AND SHOW AS NOTED ON PREVIOUS REVIEW WHERE | | | THESE ARE FIGURED INTO THE LOAD CALCULATIONS PER NEC | | | SECTIONS AS GIVEN. | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE MISSING SHOW WINDOW/DISPLAY WINDOW AREAS | | | WHICH WILL REQUIRE RECEPTACLES LOCATED ABOVE THE WINDOW | | | AREAS AND PORTIONS THEREOF.PLEASE SEE THE LOADS FOR | | | THE SHOW WINDOWS SHALL COMPLY WITH 220.43A FOR FEEDER | | | CALCULATIONS. THE CALCULATION OF 200 VOLT-AMPERES FOR | | | EACH LINEAR FOOT OF A SHOW WINDOW IS REQUIRED TO | | | DETERMINE THE FEEDER LOAD. SEE THE COMMENTARY FOLLOWING | | | 220.14(G) FOR LOAD CALCULATIONS FOR BRANCH CIRCUITS IN | | | SHOW WINDOWS. | | | AS NO LOAD CALCULATIONS WERE SUBMITTED, REVIEW OF THIS | | | FOR CODE COMPLIANCE CAN NOT BE DONE AT THIS TIME. | | | | | | 7) NOTE:PLEASE SEE THE PREVIOUS NOTE REQUESTED A | | | SIGNED, DATED, SEALED AND NOTARIZED LETTER FROM THE | | | DESIGNER O RECORD FOR SIGNATURE. PLEASE SEE A LETTER | | | WAS SUBMITTED HOWEVER PLEASE SEE THIS LETTER IS NOT | | | ORIGINAL, AND IT WAS NOT SEALED. | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE PLANS APPEAR TO BE SIGNED WITH INITIALS, IF | | | THIS IS INDEED THE LEGAL SIGNATURE PLEASE SUBMIT A | | | SIGNED, DATED AND SEALED NOTARIZED LETTER. FS 471.025 | | | THIS WILL BE PLACED IN OUR SIGNATURE FILE FOR ANY | | | FUTURE REFERENCE. | | | PLEASE ALSO BE SURE THE LETTER IS ORIGINAL AND IS | | | PROPERLY NOTARIZED PER FS 117.05. | | | | | | 8) NOTE: PLEASE SEE NO INFORMATION WAS SUBMITTED FOR | | | THE MINIMUM COMPLIANCE FOR ADA PER FBC AS PREVIOUSLY | | | STATED. RESPONSE MENTIONS THIS WILL BE COMPLIED WITH, | | | HOWEVER COULD NOT LOCATE THIS AND RESPONSE IS UNCLEAR. | | | ** PREVIOUS REVIEW NOTE ** | | | PLEASE SEE THAT PLANS MENTIONS FIRE ALARM SYSTEM AND | | | SECURITY ALARM SYSTEM. | | | PLEASE KNOW BASED ON THIS BUILDING AND IT BEING | | | SPRINKLED AND FIRE ALARM PROTECTED, PLEASE SEE FIRE | | | REVIEW COMMENTS WHICH WILL REQUIRED FIRE SPRINKLER | | | LAYOUT AND PLEASE SHOW FA DEVICES ON BASED BUILDING | | | PLANS. PLEASE KNOW THAT EVEN THOUGH ANY FIRE ALARM AND | | | FIRE SPRINKLER WORK WILL BE DONE UNDER A SEPARATE | | | PERMIT, THE BASE PLANS ARE REQUIRED TO SHOW | | | PROTECTION. | | | PLEASE BE SURE ALL DEVICES AS REQUIRED IN FBC | | | 11-4.28.1, .2 AND .3(4) AS SHOWN WITH MINIMUM LEVELS | | | FOR ADA COMPLIANCE. | | | FBC 106.1.2, 106.3.5.1.2 | | | | | | 9) NOTE: PLEASE SUBMIT THE MANUFACTURES SPECS/CUT | | | SHEETS FOR THE UPS SYSTEM EQUIPMENT. | | | 110.3, 90.7 | | | | | | 10) NOTE: PLEASE DO NOT ATTACH ALL OF THE RESPONSES, | | | LETTERS REPORTS, PRODUCT APPROVALS, AND OTHER | | | SUPPORTING DOCUMENTS DOWN THE LEFT SIDE OF PLANS. THIS | | | SHOULD BE ATTACHED, MADE INTO TWO SEPARATE SETS OF | | | SUPPORTING DOCUMENTS. (FOLDERS, SPIRAL BOUND, TABBED | | | ETC. | | | THESE DOCUMENTS WERE REMOVED FROM ONE SET FOR EASE OF | | | REVIEW. | | | FBC ADMIN SECTION 106.3 | | | | | | 11) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO | | | REPEAT COMMENTS. THIS IS ONLY A NOTICE GIVEN AT THIS | | | TIME. | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | | | | | ** PLEASE SEE ANY POSSIBLE COMMENTS FROM OTHER TRADES | | | WHICH MAY AFFECT ELECTRICAL PLANS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-03-20 |
|
|
Cont ID |
|
| Sent By |
dpalmer |
Date |
2007-03-20 |
Time |
18:30 |
Rev Time |
0.00 |
| Received By |
dpalmer |
Date |
2007-03-19 |
Time |
19:55 |
Sent To |
|
|
| Notes |
| 2007-03-20 18:31:26 | ** UNSAT ** | | | | | | * PLEASE KNOW THAT ANY REFERENCE TO THE FBC CHAPTER 1 | | | WILL BE FROM THE ADMINISTRATIVE SECTION OF THE CODE AS | | | ADOPTED BY THE CITY OF WEST PALM BEACH. | | | | | | 1) NOTE: PLEASE SEE MISSING LICENSE NUMBER FOR THE | | | LANDSCAPE FIRM AS LISTED ON THE TITLE BLOCKS FOR *L* | | | SHEETS. THIS IS ALSO KNOWN AS THE CERTIFICATE OF | | | AUTHORIZATION NUMBER. | | | PLEASE SEE 481.219, FAC 61G1-16.004 | | | THIS IS REQUIRED WHETHER OR NOT COMMENT IS MADE BY | | | OTHER TRADES. | | | | | | 2) NOTE: PLEASE SEE THE MISSING LICENSE NUMBER FOR THE | | | SURVEY FIRM AS REQUIRED PER FS 472.021. 61G17 | | | ALSO KNOWN AS THE CERTIFICATE OF AUTHORIZATION NUMBER. | | | | | | PLEASE ALSO SEE THAT THE SIGNATURE MUST BE ORIGINAL AS | | | REQUIRED PER FS 472.025 | | | PLEASE SEE THE PLANS EVEN CONTAIN THE STATEMENT THIS IS | | | REQUIRED, HOWEVER PLANS CONTAIN A RAISED SEAL OVER A | | | *PHOTO-COPIED SIGNATURE*. | | | THIS COMMENT IS REQUIRED WHETHER OR NOT COMMENT IS MADE | | | BY OTHER TRADES. | | | | | | 3) NOTE: PLEASE SEE THAT ALL OF THE CODES WHICH PLANS | | | ARE UNDER DESIGN AND RECORD SHALL BE STATED ON PLANS AS | | | FOLLOWS. PLEASE SEE THAT THERE ARE SEVERAL LOCATIONS | | | WHICH CODES FROM OLDER ADOPTED CODES ARE STATED ON | | | PLANS. PLEASE ALSO SEE THAT THE PLANS ALSO CONTAIN | | | STATEMENTS IN DIFFERENT LOCATIONS FOR THE *STANDARD | | | BUILDING *. | | | PLEASE KNOW THAT THE STANDARD BUILDING CODE WAS NO | | | LONGER IN AFFECT AS OF MARCH 1ST, 2002 WHEN THE STATE | | | OF FLORIDA ADOPTED THE 2001 FBC. | | | PLEASE KNOW THAT AS OF DECEMBER 8TH, 2006 THE FOLLOWING | | | CODE(S) WERE ADOPTED. PLEASE LIST THE FOLLOWING AT A | | | MINIMUM FOR THIS REVIEWER. | | | 2004 FBC W/ 2006 REVISIONS. | | | 2005 NFPA-70 | | | 2003 NFPA-101 | | | 2002 NFPA-72 | | | | | | ** THESE ARE REQUIRED FOR THIS REVIEWER AT A MINIMUM | | | AND OTHER CODES WILL BE REQUIRED FOR OTHER TRADES. | | | | | | 4) NOTE: ALL SIGNS, FIRE ALARM, FIRE SPRINKLER, | | | BURGLAR/SECURITY PERMITS WILL BE UNDER SEPARATE PERMITS | | | WITH SEPARATE PLANS AND PERMIT FEES. | | | | | | 5) NOTE: PLEASE SEE THE VALUE SHALL INCLUDE ALL LABOR | | | AND MATERIALS EVEN IF ANY EQUIPMENT OR MATERIALS ARE | | | OWNER SUPPLIED.PLEASE SEE THE TOTAL VALUE IS TO | | | INCLUDE ALL LIGHTING, EQUIPMENT, LOW VOLTAGE ETC. THIS | | | WILL BE VERIFIED FOR BASE BUILDING AND BASE PME FROM | | | THE TABLES AS SET-FORTH IN THE FBC. | | | FBC ADMIN SECTION 108.3 | | | | | | 6) NOTE: PLEASE SEE THAT PLANS E0.1 AND E0.1A INDICATE | | | TWO DIFFERENT TYPES OF SITE LIGHTING POLES EVEN FOR THE | | | SAME SYMBOL. EACH OF THESE SHEETS ARE DONE BY A | | | DIFFERENT DESIGNER. PLEASE CORRELATE. | | | PLEASE SEE ONE SHEET WHICH MENTIONS WIND LOAD RATINGS | | | TO BE 150MPH AND BELOW. IT CAN BE UNDERSTOOD IF THIS | | | STATEMENT SAID 150 OR ABOVE, HOWEVER HOW COULD THIS BE | | | BELOW? | | | PLEASE SEE THE NEXT LEVEL DOWN STATES 120MPH AND BELOW | | | AND SO ON. PLEASE KNOW THAT ALL LIGHTING SHALL MEET | | | THIS AREA FOR WIND LOADSAT 140MPH. | | | PLEASE SUBMIT THE ENGINEERING ON POLES WITH LIGHTING | | | FIXTURES WHICH INDICATES THE EFFECTIVE PROJECTED AREA | | | OF FIXTURES ETC. THE ACTUAL CALCULATIONS WILL BE | | | REVIEWED BY THE BUILDING REVIEWER ONCE SUBMITTED. | | | PLEASE SEE THAT THE SITE PLANS INDICATE LIGHTING POLES | | | LOCATED OFF SITE AND NOT ON THIS PROPERTY/LEGAL | | | ADDRESS. PLEASE KNOW THAT THESE WILL BE REQUIRED UNDER | | | A SEPARATE PERMIT AND MAY NOT BE INCLUDED ON THESE | | | PLANS. | | | | | | 7) NOTE: PLEASE SEE THE ADDRESS FOR THIS PROJECT IS | | | 9921 OKEECHOBEE BLVD. PLEASE INCLUDE THIS INFORMATION | | | AS REQUIRED ON TITLE BLOCKS. | | | FAC 61G1-16.004, FAC 61G15-23.002 | | | | | | 8) NOTE: PLEASE SEE THAT A VOLTAGE DROP SUMMARY WAS | | | SUBMITTED FOR PANELS AND SOME ITEMS HOWEVER NOT | | | SUBMITTED FOR SITE LIGHTING AND OTHER WORST CASE | | | SCENARIOS PER FBC 13-413.1ABC.1 | | | | | | 9) NOTE: PLEASE SEE THE LOCATION OF THE MAIN SERVICE | | | MEANS OF DISCONNECT IS NOT APPROVED AT THIS TIME PER | | | THIS AHJ. | | | PLEASE SEE THAT THE LOCATION SHALL BE READILY | | | ACCESSIBLE AT THE NEAREST POINT OF ENTRANCE INTO THE | | | BUILDING IF THE MAIN IS GOING TO BE LOCATED INSIDE THE | | | BUILDING. AS SHOWN ON PLANS, THIS MAIN IS ONLY OBTAINED | | | IN THE CASE OF AN EMERGENCY BY FIRE DEPARTMENT | | | PERSONNEL BY TRAVERSING THROUGH AT LEAST FOUR LOCKED | | | DOORS AND A SUBSTANTIAL NOT RATED PATH OF TRAVEL INTO | | | THE BUILDING. | | | PLEASE KNOW THAT THIS HAS BEEN GONE OVER WITH THE FIRE | | | MARSHAL CHIEF AND LOCATION IS ALSO NOT ACCEPTED. ** | | | PLEASE CALL TO GO OVER OTHER LOCALS IF NEED BE. (LOCATE | | | MAIN OUTSIDE, DOOR FROM OUTSIDE INTO THE MAIN | | | ELECTRICAL FIRE RATED (1HR MINIMUM) ROOM? ETC) 230.70, | | | 230.71, 90.4 NEC. | | | FBC ADMIN SECTION 104.6 | | | | | | 10) NOTE: PLEASE SEE PLANS APPEAR TO INDICATE SOME SORT | | | OF *OUTLET* TAPPED FROM THE WATER HEATER SHOWN ON | | | PLANS? PLEASE CLARIFY THIS. | | | FBC 106.1.2. | | | | | | 11) NOTE: PLEASE KNOW THAT ANY (LOCK ON/LOCK OFF | | | DEVICES WHICH ARE BEING INSTALLED ONLY IN THE ATTEMPT | | | TO BE USED AS THE DISCONNECTING MEANS OF EQUIPMENT OR | | | APPLIANCES SHALL HAVE THE DEVICE PERMANENTLY AFFIXED TO | | | BREAKER SO THAT THE DEVICE CAN NOT BE READILY REMOVED | | | UNLESS THE BREAKER IS REMOVED. | | | PLEASE KNOW IF NONE OF THE DEVICES AS NOTED ON PLANS | | | ARE FOR THIS PURPOSE AND ONLY BEING USED FOR LOCKING ON | | | THE CIRCUITS THEN PLEASE STATE DEVICE(S). | | | PLEASE KNOW THAT A NOTE WILL BE REQUIRED ON PLANS IN | | | ADDITION TO THE *LOCK-OFF* NOTE WHICH STATES THAT THE | | | DEVICE MUST BE AN INTEGRAL PART OF THE BREAKER OR WORDS | | | TO THAT AFFECT. | | | 110.3, 90.4. | | | | | | 12) NOTE: PLEASE SEE 2004 FBC W/2006 REVISIONS FOR | | | CHAPTER 13. | | | PLEASE SEE 13-415.1.ABC.1.1, .1.2 AND .1.3.PLEASE SEE | | | SOME LOCATIONS WHICH DO NOT INDICATE ANY LIGHTING | | | CONTROLS UNDER AN AUTOMATED MEANS. PLEASE SEE THAT | | | THESE DEVICES NEED TO BE SHOWN AS SOME OF THE DEVICES | | | SHOWN SEEM TO BE NORMAL CONTROL SWITCHES AND SOME AREAS | | | DO NOT SEEM TO INDICATE OCCUPANCY TYPE DEVICES. PLEASE | | | SEE THE COOLER, FREEZER, DRIVE THRU SWITCH, TOWER | | | SWITCH, PHOTO-LAB ETC. PLEASE VERIFY ALL LOCATIONS. | | | PLEASE INDICATE THE MAXIMUM OVER RIDE TIMES, AND TIMES | | | FOR ALL DEVICES. THE PLANS DO CONTAIN SOME NOTES WHICH | | | STATE 2HRS HOWEVER NOT FOR ALL. | | | PLEASE SEE OUTSIDE LIGHTING IS REQUIRED TO BE ON AN | | | ASTRONOMICAL TIME CLOCK WITH CONTROLS TO SHUT LIGHTING | | | OFF WHEN SUFFICIENT DAY LIGHT IS PRESENT. | | | PLEASE SEE 13-415.1.ABC.3 FOR TANDEM WIRING. PLEASE SEE | | | THE LIGHTING FIXTURE LEGEND DOES NOT CORRELATE WITH THE | | | ENERGY CALCULATIONS SUBMITTED. PLEASE ALSO SEE THE | | | TOTAL WATTAGE AND MAXIMUM LIGHTING POWER DENSITIES AS | | | SHOWN CAN NOT BE VERIFIED. PLEASE SEE THAT THE LIGHTING | | | ENERGY CALCULATIONS DO NOT INDICATE THE EXTERNAL AND | | | EXTERIOR LIGHTING AS SHOWN ON PLANS. | | | PLEASE SEE THAT THE ENERGY CALCULATIONS SUBMITTED | | | INDICATES *MANUAL ON/OFF* FOR ALL LIGHTING? PLEASE SEE | | | THAT THIS IS NOT POSSIBLE WHEN THE LIGHTING IS | | | AUTOMATED. | | | PLEASE SEE THE SHEET #3 NEEDS TO CONTAIN THE | | | INFORMATION AS NEEDED FOR PRINTED INFORMATION FOR THE | | | DESIGNER OF RECORD, SIGNED, DATED AND SEAL.PLEASE BE | | | SURE ALL TO SEE 13-103.1.1.1 | | | | | | 13) NOTE: PLEASE SEE SOME OF THE DEVICES AS NOTED FOR | | | OCCUPANCY DEVICES ARE ONLY 180 DEGREE DEVICES, WHICH | | | WHEN AN OCCUPANT IS LOCATED IN SOME AREAS ON THE PLANS | | | THIS DEVICE AND THE DIRECTION AS NOTED WOULD NOT PICK | | | UP ON THE OCCUPANT AND THERE FORE TURNING LIGHTING OFF | | | AND MAY CREATE A HAZARD. | | | PLEASE SEE SOME REDLINED AREAS ON PLANS WHICH ARE OF | | | CONCERN. IF THESE DEVICES ARE COMBO DEVICES WHICH | | | PROVIDE ULTRASONIC SENSING THEN THIS MAY NOT BE AN | | | ISSUE. PLEASE VERIFY ALL LOCATIONS AND TYPES OF DEVICES | | | FOR FULL COVERAGE. | | | LS 101 7.8, 7.9 | | | | | | 14) NOTE: PLEASE SEE MISSING SHOW WINDOW/DISPLAY WINDOW | | | AREAS WHICH WILL REQUIRE RECEPTACLES LOCATED ABOVE THE | | | WINDOW AREAS AND PORTIONS THEREOF.PLEASE SEE THE | | | LOADS FOR THE SHOW WINDOWS SHALL COMPLY WITH 220.43A | | | FOR FEEDER CALCULATIONS. THE CALCULATION OF 200 | | | VOLT-AMPERES FOR EACH LINEAR FOOT OF A SHOW WINDOW IS | | | REQUIRED TO DETERMINE THE FEEDER LOAD. SEE THE | | | COMMENTARY FOLLOWING 220.14(G) FOR LOAD CALCULATIONS | | | FOR BRANCH CIRCUITS IN SHOW WINDOWS. | | | AS NO LOAD CALCULATIONS WERE SUBMITTED, REVIEW OF THIS | | | FOR CODE COMPLIANCE CAN NOT BE DONE AT THIS TIME. | | | | | | 15) NOTE: PLEASE SEE MISSING SIGN CIRCUIT ON PLANS AND | | | PANEL SCHEDULE FOR THE MINIMUM LOADS AS INDICATED IN | | | THE NEC. THIS CIRCUIT IS TO BE LOCATED AT A MINIMUM AT | | | THE LOCATION OF THE FRONT ENTRANCE AS REQUIRED PER | | | 600.5. | | | | | | 16) NOTE: PLEASE SEE PLANS APPEAR TO BE SIGNED WITH | | | INITIALS, IF THIS IS INDEED THE LEGAL SIGNATURE PLEASE | | | SUBMIT A SIGNED, DATED AND SEALED NOTARIZED LETTER. FS | | | 471.025 | | | THIS WILL BE PLACED IN OUR SIGNATURE FILE FOR ANY | | | FUTURE REFERENCE. | | | PLEASE ALSO BE SURE THE LETTER IS ORIGINAL AND IS | | | PROPERLY NOTARIZED PER FS 117.05. | | | | | | 17) NOTE: PLEASE SEE THAT PLANS MENTIONS FIRE ALARM | | | SYSTEM AND SECURITY ALARM SYSTEM. | | | PLEASE KNOW BASED ON THIS BUILDING AND IT BEING | | | SPRINKLED AND FIRE ALARM PROTECTED, PLEASE SEE FIRE | | | REVIEW COMMENTS WHICH WILL REQUIRED FIRE SPRINKLER | | | LAYOUT AND PLEASE SHOW FA DEVICES ON BASED BUILDING | | | PLANS. PLEASE KNOW THAT EVEN THOUGH ANY FIRE ALARM AND | | | FIRE SPRINKLER WORK WILL BE DONE UNDER A SEPARATE | | | PERMIT, THE BASE PLANS ARE REQUIRED TO SHOW | | | PROTECTION. | | | PLEASE BE SURE ALL DEVICES AS REQUIRED IN FBC | | | 11-4.28.1, .2 AND .3(4) AS SHOWN WITH MINIMUM LEVELS | | | FOR ADA COMPLIANCE. | | | FBC 106.1.2, 106.3.5.1.2 | | | | | | 18) NOTE: PLEASE SEE AS NOTED ABOVE FOR CODES; PLEASE | | | SEE THAT THE LOAD CALCULATIONS INDICATE SECTIONS OF THE | | | CODE WHICH ARE FROM PREVIOUS CODES NO LONGER IN | | | EFFECT. | | | 220.11, 220.13. | | | | | | 19) NOTE: PLEASE CLARIFY AND SHOW THE BRANCH CIRCUITS | | | CONDUCTOR SIZES FOR ALL. CAN BE DONE IN A TYPICAL | | | DIAGRAM IF THIS IS INDEED THAT CASE, HOWEVER PLEASE SEE | | | AREAS WITH VOLTAGE DROP WHICH MAY BE AFFECTED TO SHOW A | | | LARGER CONDUCTOR ON A BRANCH CIRCUIT WITH SMALLER OCP. | | | 240.4, 310.16 | | | | | | 20) NOTE: PLEASE SUBMIT THE MANUFACTURES SPECS/CUT | | | SHEETS FOR THE UPS SYSTEM EQUIPMENT. | | | 110.3, 90.7 | | | | | | * ** IMPORTANT** | | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | | PICKED UP FOR CORRECTIONS, PLEASE BE | | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | | SHEETS AND ONLY INSERT NEW REVISED | | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | | AND STAMPING. DO NOT LEAVE ANY | | | OLD/VOIDED SHEETS IN SETS. | | | PLEASE KNOW ONLY ONE SET OF THE | | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | | FOR REFERENCE. | | | THIS WILL HELP IN THE REVIEW PROCESS AND | | | AVOID ANY DELAYS. | | | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | | REVIEWER. | | | | | | | | | DEWEY PALMER | | | ELECTRICAL PLAN REVIEW II | | | CONSTRUCTION SERVICES DEPT. | | | CITY OF WEST PALM BEACH | | | 561-805-6717 | | | [email protected] | | 2007-03-20 07:02:06 | 2007-03-20 07:02:06 | | | REVIEW IN PROGRESS | | 2007-03-19 20:08:58 | 2007-03-19 20:08:58 | | | IN ELEC FOR REVIEW, NOTES TO FOLLOW ONCE REVIEW IS | | | COMPLETE. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
4 |
Status |
P |
Date |
2007-11-09 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-11-09 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-11-09 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2007-11-09 13:50:13 | PASSED BASED ON THE FOLLOWING BASES: | | | | | | 1.RECEIVED STORM WATER APPROVAL E-MAIL FROM DANIEL | | | ROBERAGE ON 10/19/07. | | | | | | 2. RECEIVED WATER/SEWER APPROVAL E-MAIL FROM MANNY | | | GONZALEZ ON 11/08/07. | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
F |
Date |
2007-10-03 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-10-03 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-10-03 |
Time |
13:13 |
Sent To |
|
|
| Notes |
| 2007-10-03 13:38:28 | ****FAILED**** | | | | | | 1. CIVIL DWG SHEET 2 OF 10 NOT SEALED & SIGNED | | | 2. WATER QUALITY CALS MUST BE APPROVED FROM 100045TH | | | STREET, ENGINEERING SERVICES DEPT.MR. BRAMLEY | | | 3. WATER & SEWER MUST BE APPROVED FROM MANNY OR EMRERY | | | 100045TH STREET. ENGINEERING | | | | | | ONCE YOU MEET ABOVE INFO, PLEASE RESUBMIT ALL YOU | | | SUBMITTED THIS TIME FOR OUR STAMP & APPROVAL. | | | | | | RASIKCHOKSHI805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2007-07-05 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-07-05 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-07-05 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2007-07-05 14:02:11 | **FAILED** FOR FOLLOWING REASONS: | | | | | | 1. SHEETS 2 OF 9, & 5 OF 9 OF SIMMON & WHITE, HAVE | | | RUBBER STAMP PE BY MR. BOLEN AND METAL SEAL BY | | | DIFFERENT PE, THAT IS NOT ALLOWED BY FBPE | | | 2. PLEASE PROVIDE A COPY OF NOTICE OF INTENT (NOI) FROM | | | FDEP. YOU NEED TO APPLY AT FDEP FOR NOI. | | | 3. PLEASE SHOW STANDARDS NOTES OF CITY OF WPB ON | | | DRAWINGSFOR SIDEWALK WIDTH , ITS SLOPE, DRIVEWAY, | | | PARKING, HANDICAP PARKING, PAINTING DETAILS FOR PARKING | | | PER CITY CODES ETC.,, MUST MEET PER ADA,,ETC.,YOU CAN | | | GET STANDARD NOTES OF CITY OFWPB IN A C.D. FROM 1000 | | | 45TH STREET. ENG DEPT.WE SHOULD HAVE THOSE NOTES ON | | | YOUR DRAWINGS. | | | 4. DO YOU HAVE DUMPSTER? IF YOU DO, PLEASE SHOW ON | | | DRAWINGSDUMPSTER & ITS ENCLOSURE DETAILS PER CITY OF | | | WPB, &LOCATION ON DWG, LOCATION MUST BE ACCESSIBLE | | | FOR PICKUP TRUCK. | | | 5. FIRST FLOOR ELEVATION, CENTER LINE OF ROAD , | | | SIDEWALK ELEVATION MUST MEET FLOOD ZONE AREA, & 5,10, | | | 25, 100 YEAR FLOOD CRITERIATO DETERMINE THE FIRST | | | FLOOR ELEVATION, MUST MEET MINIMUM REQUIREMENTS, PLEASE | | | SHOW IN THE CALCULATION. | | | 6.PLEASE SHOW STORM WATER QUALITY CALCULATIONS, WHAT | | | CRITERIA YOU ASSUMEDFOR RUNOFF CAL.,, LIKE 1" OVER | | | ENTIRE SITE OR2.5"CRITERIA, ETC, ? PLEASE SHOW IN | | | THE CALCULATIONS. | | | 7. HOW YOU CONNECT TO THE STORM WATER PIPES IN YOUR | | | SITE? PLEASE SHOW ALL STORM WATER PIPES AROUND YOUR | | | SITE SO, WE CANSEE THE BEST PIPE TO CONNECT WITH THE | | | STORM WATER FROM ALL OTHER STORM WATER PIPES. | | | 8. PLEASE SHOW POLLUTION PREVENTION DETAILS,CLOTHES | | | USED FOR SILT ETC., PLANS SHOWING SILT FENCE AROUND THE | | | SITE & CATCH BASINS.HEIGHT OF FENCE SHOULD BE HIGH | | | ENOUGH PER FDEP TO STOP DUST & PARTICLES. | | | | | | PLEASE RESPOND EACH ITEM IN DETAIL TO EXPEDITE YOUR | | | PERMITTING PROCESS | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2007-03-22 |
|
|
Cont ID |
|
| Sent By |
rchokshi |
Date |
2007-03-22 |
Time |
13:47 |
Rev Time |
0.00 |
| Received By |
rchokshi |
Date |
2007-03-22 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2007-03-22 13:47:11 | PLEASE SUBMIT THE CIVIL DRAWINGS, STORM WATER | | | CALCULATIONS,PERVIOUS, IMPERVIOUS AREA,GEOTECH | | | REPORT, , A COPY OF SFWMD PERMIT,ETC. FOR REVIEW. | | | | | | RASIK CHOKSHI805-6723 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
4 |
Status |
P |
Date |
2007-12-03 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-12-03 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-12-03 |
Time |
16:45 |
Sent To |
|
|
| Notes |
| 2007-12-03 17:14:31 | *****APPROVED***** | | | | | | THE COMMENTS FROM THE PREVIOUS FIRE PLAN REVIEWS HAVE | | | BEEN ADDRESSED;PLAN SHEETS A2.1, A3.1, E1.1, E1.6, | | | LS.1 AND THE (3) FP-3 WERE STAMPED, INITIALED, AND | | | DATED. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
F |
Date |
2007-10-12 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-10-12 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-10-12 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2007-10-12 13:20:09 | *****DENIED***** | | | | | | *THE FOLLOWING COMMENTS FROM THE PREVIOUS FIRE PLAN | | | REVIEW STILL NEED TO BE ADDRESSED: | | | | | | 04.ON THE APPROPIATE EXTERIOR ELEVATION ON A2.1, | | | DISPLAY THE NUMERICAL ADDREESS ON THE BUILDING TO BE | | | VISIBLE FROM OKEECHOBEE BOULEVARD. SHOW ACTUAL | | | ADDRESS NUMBER ON APPROPIATE EXTERIOR ELEVATION | | | | | | 05.INTERIOR WALL AND CEILING FINISH MATERIAL SHALL BE | | | CLASS A OR CLASS B.PLEASE BE ADVISED THAT THE | | | RESPONSE ON SHEET A3.1 REFERS TO NFPA 2001.THIS | | | SHOULD BE NFPA 2003 | | | | | | 12. THIS STRUCTURE WILL HAVE A FIRE ALARM SYSTEM. | | | PROVIDE A LAYOUT OF THE FIRE ALARM SYSTEM SIGNED, | | | SEALED, AND DATED. | | | | | | 13.IT IS INDICATED THAT THE STRUCTURE IS TO BE 100% | | | SPRINKLERED.PROVIDE A LAYOUT OF THE FIRE SPRINKLER | | | SYSTEM SIGNED, SEALED, AND DATED. | | | | | | *NEW COMMENT | | | | | | AA.ON SHEET LS.1 UNDER CODE REQUIREMENTS,AMEND NOTE | | | TO REFLECT FLORIDA FIRE PREVENTION CODE 2004 EDITION | | | AND NFPA 101 - 2003 EDITION. | | | | | | | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE (ON THE PLANS) EACH ITEM | | | WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2007-06-26 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-06-26 |
Time |
10:26 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-06-25 |
Time |
16:40 |
Sent To |
|
|
| Notes |
| 2007-06-25 18:09:38 | *****DENIED***** | | | | | | | | | 01.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 02.CONSTRUCTION AND/OR DEMOLITION OPERATIONS SHALL | | | NOT INTERFERE OR HINDER EMERGENCY ACCESS RESPONSE TO | | | THE SAID PROPERTY OR VICINITY THEREOF (INCLUDING FIRE | | | LANES). | | | | | | 03.ACCUMULATIONS OF COMBUSTIBLE WASTE MATERIAL, DUST, | | | AND DEBRIS SHALL BE REMOVED FROM THE SITE AT THE END OF | | | EACH SHIFT OR MORE FREQUENTLY AS NECESSARY FOR SAFE | | | OPERATION. | | | | | | 04.ON THE APPROPIATE EXTERIOR ELEVATION ON A2.1, | | | DISPLAY THE NUMERICAL ADDREESS ON THE BUILDING TO BE | | | VISIBLE FROM OKEECHOBEE BOULEVARD.PLEASE NOTE THAT | | | THE ADDRESS IS TO VISIBLE EVEN IF SECURITY AND/OR | | | HURRICANE SHUTTERS ARE INSTALLED. | | | | | | 05.INTERIOR WALL AND CEILING FINISH MATERIAL SHALL BE | | | CLASS A OR CLASS B.BE SPECIFIC | | | | | | 06.INTERIOR FLOOR FINISHSHALL BE CLASS I OR CLASS II. | | | BE SPECIFIC | | | | | | 07.THE NUMERICAL ADDRESS SHALL BE IN THE TITLE BLOCK | | | OF EACH SUBMITTED PLAN SHEET. | | | | | | 08.PROVIDE TRAVEL DISTANCE TO EXITS AS IN ACCORDANCE | | | 7.6.1 OF NFPA 101 I.E. LIFE SAFETY PLAN. | | | | | | 09.ADDITIONAL EXIT SIGNS MAY BE REQUIRED WHEN RACKS, | | | SHELVES, AND OTHER EQUIPMENT OBSCURE VISIBILITY OF THE | | | NOW PROPOSED EXIT MARKINGS. | | | | | | 10.CHECKOUT STANDS OR ASSOCIATED RAILINGS OR BARRIERS | | | SHALL NOT OBSTRUCT EXITS, REQURED AISLES, OR APPROACHES | | | THERETO. | | | | | | 11.AISLES LEADING TO EACH EXIT SHALL BE REQUIRED AND | | | THE AGGREGATE WIDTH SHALL NOT BE LESS THAN THE REQUIRED | | | WIDTH OF THE EXIT.OTHER AISLES SHALL NOT BE LESS THAN | | | 36" IN CLEAR WIDTH. | | | | | | 12.WILL THIS STRUCTURE HAVE A FIRE ALARM SYSTEM?IF | | | SO, PROVIDE A LAYOUT OF THE FIRE ALARM SYSTEM. | | | | | | 13.IT IS INDICATED THAT THE STRUCTURE IS TO BE 100% | | | SPRINKLERED.PROVIDE A LAYOUT OF THE FIRE SPRINKLER | | | SYSTEM. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE (ON THE PLANS) EACH ITEM | | | WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
N |
Date |
2007-06-25 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-06-25 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-06-25 |
Time |
16:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2008-07-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-07-11 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-07-11 |
Time |
11:00 |
Sent To |
B |
|
| Notes |
| 2008-07-11 11:01:05 | TO "JWITMER" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2008-04-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-04-30 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-04-30 |
Time |
08:46 |
Sent To |
|
|
| Notes |
| 2008-04-30 08:50:03 | TO "COMM" BD#20 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2008-01-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2008-01-04 |
Time |
16:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2008-01-04 |
Time |
16:21 |
Sent To |
P |
|
| Notes |
| 2008-01-04 16:22:28 | TO "P" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-10-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-30 |
Time |
12:24 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-30 |
Time |
12:24 |
Sent To |
|
|
| Notes |
| 2007-11-13 09:54:23 | TO "COMM" BD#40 | | 2007-10-30 12:25:04 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-08-22 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-08-22 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-08-22 |
Time |
09:25 |
Sent To |
|
|
| Notes |
| 2007-09-11 08:44:59 | TO "COMM" BD#53 | | 2007-08-22 09:25:50 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-05-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-05-21 |
Time |
15:12 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-05-21 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2007-06-21 14:20:17 | TO "COMM" BD#40 | | 2007-05-21 15:12:28 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-07-05 |
|
|
Cont ID |
|
| Sent By |
lmartine |
Date |
2007-04-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmartine |
Date |
2007-03-16 |
Time |
09:31 |
Sent To |
|
|
| Notes |
| 2007-03-16 16:53:57 | TO "COMM" BD#40 | | 2007-03-16 09:31:27 | WAITING FOR "COMM" BD |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2008-05-14 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2008-05-14 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2008-05-14 |
Time |
14:11 |
Sent To |
PC |
|
| Notes |
| 2008-05-14 14:12:24 | REVISED PG A4.5 CONDENSER STANDS |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2007-06-23 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-06-23 |
Time |
09:43 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-06-23 |
Time |
09:40 |
Sent To |
|
|
| Notes |
| 2007-06-23 09:43:15 | CONDITIONS OF PROVISO HAVE BEEN SATISFIED ON PAGES M2.1 | | | AND M2.2 REV. 1 DATED 5/8/07. | | | PG ME1.1 ALSO REVIEWED. | | | | | | RONALD J REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2007-04-05 |
|
|
Cont ID |
|
| Sent By |
rregueir |
Date |
2007-04-05 |
Time |
19:01 |
Rev Time |
0.00 |
| Received By |
rregueir |
Date |
2007-04-05 |
Time |
17:30 |
Sent To |
|
|
| Notes |
| 2007-04-05 19:01:18 | ***************PROVISO**************** | | | 1. AUXILIARY OR SECONDARY DRAIN PROTECTION IS REQUIRED | | | PER FBC,M 307.2.3 | | | | | | 2. CONDENSATE DRAINS SHALL BE TRAPPED AS REQUIRED BY | | | EQUIPMENTMANUFACTURER PER FBC,M 307.2.4. IF AN | | | ALTERNATE METHOD IS TO BE USED, SIGNED AND SEALED | | | APPROVAL BY THE EQUIPMENT MANUFACTURER'S ENGINEER IS | | | REQUIRED. | | | | | | ANY QUESTIONS PLEASE CONTACT: | | | RONALD J REGUEIRO | | | 561.805.6719 | | | [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
5 |
Status |
P |
Date |
2008-01-17 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2008-01-17 |
Time |
14:37 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2008-01-17 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2008-01-17 14:38:24 | REVISION OK - SHT P2.2 STORM RISER |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2007-12-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-12-05 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-12-05 |
Time |
10:50 |
Sent To |
|
|
| Notes |
| 2007-12-05 10:51:41 | | | | | | | | | | PASSED/PROVISO'S: | | | | | | 1. ALL LAV FAUCETS SHALL COMPLY WITH 11-4.19.5. | | | | | | 2. THE EMPLOYEE SINK FAUCET SHALL COMPLY WITH SECTION | | | 11-4.24.7. | | | | | | 3. THE EMPLOYEE SINK SHALL COMPLY WITH SECTION | | | 11-4.24.4. | | | | | | 4. AN RPZV BACKFLOW IS REQUIRED ON THE WATER | | | SERVICE. | | | | | | 5. SUBMIT A STORM RISER DIAGRAM FOR THE ROOF DRAINS | | | PIPING FOR ROOF DRAINS AT COL. LINE 3 & COL. LINE 4. | | | SHOW ALL PIPE SIZES AND INDICATE SQUARE FOOTAGE BEING | | | DRAINED. SECTION 106.3.5.1.3(7)(13). (SUBMIT PRIOR TO | | | FIRST ROUGH INSPECTION OF U/G STORM). | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2007-10-12 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-10-12 |
Time |
08:30 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-10-12 |
Time |
08:30 |
Sent To |
|
|
| Notes |
| 2007-10-12 08:48:02 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | | | | 1. SUBMIT A STORM RISER DIAGRAM FOR THE ROOF DRAINS | | | PIPING FOR ROOF DRAINS AT COL. LINE 3 & COL. LINE 4. | | | SHOW ALL PIPE SIZES AND INDICATE SQUARE FOOTAGE BEING | | | DRAINED. SECTION 106.3.5.1.3(7)(13). | | | | | | 2. SEE PROVISO'S FROM REVIEW DATED 7-11-7. PLEASE SHOW | | | COMPLIANCE FOR ALL ITEMS IN PROVISO. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-12-05 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-07-11 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-07-11 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2007-07-11 15:05:00 | | | | | | | | | | PASSED/PROVISO | | | | | | ALL LAV FAUCETS SHALL COMPLY WITH 11-4.19.5 | | | THE EMPLOYEE SINK FAUCET SHALL COMPLY WITH SECTION | | | 11-4.24.7 | | | THE EMPLOYEE SINK SHALL COMPLY WITH SECTION 11-4.24.4 | | | AN RPZV BACKFLOW IS REQUIRED ON THE WATER SERVICE | | | | | | | | | *********REVIEW STATUS CHANGED FROM PASSED/PROVISO TO | | | FAILED BECAUSE OF PLAN DEVELOPMENT CAUSED PLANS TO FAIL | | | REVIEW 10-12-07 | | | | | | | | | | | | | | | | | | . |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-04-06 |
|
|
Cont ID |
|
| Sent By |
kstevens |
Date |
2007-04-06 |
Time |
17:30 |
Rev Time |
0.00 |
| Received By |
kstevens |
Date |
2007-04-06 |
Time |
17:30 |
Sent To |
|
|
| Notes |
| 2007-04-06 17:45:48 | DENIED | | | REFERENCE: FBC-2004 PLUMBING | | | FBC-2004 BUILDING | | | FBC-2004 CHAPTER 1 | | | FBC-2004 CHAPTER 11 | | | FLORIDA ADMINISTRATIVE CODE | | | FLORIDA STATUTES | | | | | | 1. SHT A1.1 ROOM FINISH SCHEDULE. SUBMIT MANUF. | | | SPECIFICATIONS SHEETS FOR THE FIBERGLASS POLYESTER | | | PANELS. PLANELS SHALL COMPLY WITH THE REQUIREMENTS TO | | | BE "SMOOTH, HARD, NONABSORBENT" MATERIALS AS REQUIRED | | | IN SECTION 1210.2. | | | | | | 2. SHT A1.3 ROOF DRAINAGE CALCULATIONS INDICATE 4 6" | | | ROOF DRAINS AND 3 8"X24" OVERFLOW SCUPPERS. SHT P2.2 | | | ROOF LEADER RISER SHOWS A 8"X16" PRIMARY SCUPPER AND | | | 8"X16" OVERFLOW SCUPPERS. PLEASE CORRELATE ROOF | | | DRAINAGE INFORMATION. TABLE 1106.3 & SECTION 106.1.1. | | | | | | 3. SHT A4.2 SHOW COMPLIANCE FOR THE FOLLOWING: | | | A. 11-4.18.4 FLUSH CONTROLS | | | B. 11-4.19.5 FAUCETS | | | | | | 4. SUBMIT A DETAIL FOR THE EMPLOYEE ROOM SINK. SHOW | | | COMPLIANCE WITH SECTION 11-4.24 AND ALL SUBSECTIONS. | | | | | | 5. SHTS P1.1 & P2.2 ITEM 10. ALL INDIRECT WASTE SHALL | | | BE DRAINED TO EITHER A FLOOR SINK OR A HUB DRAIN. A | | | FLOOR DRAIN IS NOT AN APPROVED INDIRECT WASTE RECEPTOR. | | | SECTIONS 802.3 & 802.3.2. | | | | | | 6. SHT P2.1 DETAIL #3 WATER HEATER DETAIL. DIELECTRIC | | | UNIION ARE NOT APPROVED FOR USE IN THE WATER SYSTEM. | | | DIELECTRIC COUPLINGS ARE APPROVED. PLEASE CHANGE | | | REFERENCE. | | | | | | 7. SHT P2.1 DETAIL 1 AND SHT P2.2 DOMESTIC WATER RISER | | | DIAGRAM. THE WATER HAMMER ARRESTORS SHALL BE LOCATED | | | NEAR THE FIXTURES, IN AN "EFFECTIVE RANGE", NOT IN THE | | | CEILING AS SHOWN. PDI-WH 201 AND MANUF. INSTALLATION | | | INSTRUCTIONS. | | | | | | 8. ALL PLUMBING SHEETS. THE SIGNATURE OF THE ENGINEER | | | SIGNING & SEALING THE DOCUMENTS IS REQUIRED. IT APPEARS | | | THAT INITIALS ARE USED. IF INDEED THIS IS THE LEGAL | | | SIGNATURE OF THE ENGINEER OF RECORD, THEN A SIGNED, | | | SEALED, NOTORIZED LETTER INDICATING THE LEGAL SIGNATURE | | | WILL BE SUBMITTED FOR OUR FILES. FAC 61G15-23.002(2) | | | AND FS 471.025. | | | | | | 9. AN RPZV BACKFLOW IS REQUIRED ON THE WATER SERVICE TO | | | THE BUILDING. THIS SHALL BE AS CLOSE TO THE METER AS | | | POSSIBLE AND ON PRIVATE PROPERTY. PLEASE INDICATE ON | | | THE PLANS. SECTION 608.13.2. | | | | | | REVIEW BY KEN STEVENS | | | (561) 805-6721 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2007-09-25 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-09-25 |
Time |
20:33 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-09-25 |
Time |
20:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2007-06-18 |
|
|
Cont ID |
|
| Sent By |
jroach |
Date |
2007-06-18 |
Time |
18:55 |
Rev Time |
0.00 |
| Received By |
jroach |
Date |
2007-06-18 |
Time |
18:55 |
Sent To |
I |
|
| Notes |
| 2007-06-18 19:03:25 | ***FAILED*** | | | | | | 1) IN ADDITION TO STRIPING ON THE SITE PLAN, REGULAR | | | AND HANDICAP PARKING STRIPING DETAILS SHALL BE | | | PROVIDED, INDICATING DIMENSIONS OF STRIPING, COLOR, | | | ETC. | | | | | | 2) STRIPING SHALL BE SHOWN ON THE SITE PLAN FOR THE SIX | | | (6) PARELLEL PARKING SPACES THAT ARE TO BE LOCATED EAST | | | OF THE BY-PASS LANE. | | | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | | AT (561) 822-1435. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-03-26 |
|
|
Cont ID |
|
| Sent By |
adavila |
Date |
2007-03-26 |
Time |
08:48 |
Rev Time |
0.00 |
| Received By |
adavila |
Date |
2007-03-23 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2007-03-23 11:34:07 | PLANNING AND ZONING DEPARTMENT | | | | | | ***FAILED*** | | | | | | 1.SATELLITE DISH DETAILS MEETING SECTION 94-304(F)(2) | | | OF THE ZONING AND LAND DEVELOPMENT REGULATIONS SHALL BE | | | PROVIDED. | | | | | | 2.REGULAR PARKING AND HANDICAP PARKING STALL DETAILS | | | SHALL BE PROVIDED. | | | A.PLEASE NOTE THAT HANDICAP SYMBOL SHALL FACE RIGHT. | | | B.HANDICAP SYMBOL SHALL BE TWO (2) FEET FROM THE OPEN | | | END OF THE PARKING SPACE. | | | C.HANDICAP SYMBOL SHALL BE 3 FEET OR 5 FEET IN HEIGHT | | | AND PAINTED IN WHITE. | | | D.HANDICAP PARKING SPACES SHALL BE OUTLINED IN BLUE. | | | | | | 3.PLEASE NOTE THAT A SEPARATE PERMIT SHALL BE | | | PROVIDED FOR ALL SIGNS (TEMPORARY, WALL MOUNTED, FREE | | | STANDING, ETC.). | | | | | | 4.PLEASE NOTE THAT FOOTERS SHALL BE IN PLACED PRIOR | | | TO SITE PLAN APPROVAL EXPIRATION. | | | | | | COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q. OR JOHN | | | ROACH, SENIOR PLANNER, AT 822-1435. |
|
|
|