Plan Review Details - Permit 07030489
| Plan Review Stops For Permit 07030489 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2007-05-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-05-04 |
Time |
16:14 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-05-04 |
Time |
16:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2007-04-18 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-04-18 |
Time |
16:06 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-04-18 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2007-04-18 16:15:02 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 FAC | | | FLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.)THE SHUTTER PRODUCT APPROVALS ARE ILLEGIBLE. | | | | | | 2.)I WAS UNABLE TO REVIEW THE SHUTTER INSTALLATION | | | SCHEDULE AS I COULD NOT READ THE INFORMATION ON THE | | | PRODUCT APPROVAL. | | | | | | 3.)INDICATE WHICH MULLION PRODUCT YOU ARE USING | | | (MULLION LOAD CHART). | | | | | | 4.)YOUR APPLICATION STATES THAT YOU ARE GOING TO | | | STUCCO THE EXTERIOR.WHAT IS THE SUBSTRATE?PROVIDE A | | | DETAIL IF NECESSARY. | | | | | | THE RESPONSE LETTER ADDRESSES THE QUESTION.ALL | | | RESPONSES SHOULD BE INCORPORATED INTO THE PLAN. PROVIDE | | | A DETAIL OR SPECIFICATION, INCLUDING SHEATHING | | | NAILING. | | | | | | 5.)THE PLANS STATE THAT DESIGN CRITERIA IS FBC 1605, | | | PLEASE CLARIFY WHAT LOAD COMBINATIONS ARE USED IN THIS | | | PROJECT.ALSO REFERS TO 1606, INCORRECT CODE | | | REFERENCE. | | | | | | 6.)IT IS NOT CLEAR WHY AN ENGINEER HAS STAMPED THE | | | PRODUCT APPROVALS BUT DID NOT DRAW THE PLAN. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-03-31 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-03-31 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-03-31 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2007-03-31 11:45:18 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FACFLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | 1.)PRODUCT APPROVALS ARE FOR INSWING DOORS, OUTSWING | | | SHOWN ON THE PLAN. | | | | | | 2.)SEE ATTACHED SHUTTER INSTALLATION SCHEDULE. EITHER | | | COMPLETE THIS FORM OR PROVIDE ALL INFORMATION REQUIRED | | | TO DETERMINE CODE COMPLIANCE IN ANOTHER FORMAT. | | | | | | 3.)MULLION PRODUCT APPROVAL REQUIRED. | | | | | | 4.)YOUR APPLICATION STATES THAT YOU ARE GOING TO | | | STUCCO THE EXTERIOR.WHAT IS THE SUBSTRATE?PROVIDE A | | | DETAIL IF NECESSARY. | | | | | | 5.)THE PLANS STATE THAT DESIGN CRITERIA IS 1606.2, | | | INCORRECT CODE REFERENCE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-03-14 |
|
|
Cont ID |
|
| Sent By |
kconrad |
Date |
2007-03-14 |
Time |
18:21 |
Rev Time |
0.00 |
| Received By |
kconrad |
Date |
2007-03-14 |
Time |
18:21 |
Sent To |
I |
|
| Notes |
| 2007-03-14 18:24:03 | MET WITH HOMEOWNER AND ADVISED HIM THAT HE WILL NEED TO | | | SUBMIT PRODUCT APPROVALS FOR NEW WINDOWS AND DOORS / | | | SHUTTERS. THE STUCCO PERMIT IS DENIED UNTIL THE WINDOWS | | | AND DOORS ARE PERMITTED AND INSPECTED. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-04-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-26 |
Time |
16:09 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-26 |
Time |
16:09 |
Sent To |
B |
|
| Notes |
| 2007-04-26 16:13:12 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-04-17 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-17 |
Time |
14:31 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-17 |
Time |
14:31 |
Sent To |
B |
|
| Notes |
| 2007-04-17 14:32:13 | TO "SHILL" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-03-31 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-03-31 |
Time |
11:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-03-25 |
Time |
12:42 |
Sent To |
|
|
| Notes |
| 2007-03-25 12:42:46 | TO "MISC" BOX#1--1ST REV |
|
|
|