| Plan Review Stops For Permit 07030371 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-05-11 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-11 |
Time |
13:57 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-11 |
Time |
13:57 |
Sent To |
M |
|
| Notes |
| 2007-05-11 13:58:37 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-05-03 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-03 |
Time |
16:35 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-03 |
Time |
16:35 |
Sent To |
M |
|
| Notes |
| 2007-05-03 16:35:58 | TO "M" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-04-06 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-04-06 |
Time |
17:18 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-04-06 |
Time |
17:18 |
Sent To |
M |
|
| Notes |
| 2007-04-06 17:18:56 | TO TOM GORDON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-03-20 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-20 |
Time |
10:27 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-20 |
Time |
10:27 |
Sent To |
M |
|
| Notes |
| 2007-03-20 10:27:32 | TO "M" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-03-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-13 |
Time |
09:09 |
Rev Time |
0.00 |
| Received By |
tgordon |
Date |
2007-03-12 |
Time |
16:48 |
Sent To |
|
|
| Notes |
| 2007-03-12 16:49:04 | TO "M" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2007-05-16 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-05-16 |
Time |
08:27 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-05-16 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2007-05-16 08:28:26 | REVISION TO MECHANICAL PLANS. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2007-05-04 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-05-04 |
Time |
14:07 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-05-04 |
Time |
14:07 |
Sent To |
|
|
| Notes |
| 2007-05-04 14:10:05 | *** DENIED *** | | | 1) NEED TO SUBMIT TWO IDENTICAL SETS OF PLANS WITH NO | | | HAND MADE CHANGES ON THEM. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-04-09 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-04-09 |
Time |
09:17 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-04-09 |
Time |
09:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-03-26 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-26 |
Time |
16:10 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-03-26 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2007-03-26 16:25:18 | *** DENIED *** | | | 1) THE PLANS NEED THE JOB ADDRESS ON THEM. | | | | | | 2) THE PLANS NEED AN A/C EQUIPMENT LISTING ON THEM | | | SHOWING THE A/C EQUIPMENT MANUF., MODEL NUMBER, TOTAL | | | BTU'S, SENSIBLE BTU'S, SEER, AND ALL OTHER PERTINENT | | | INFORMATION, PLEASE ALSO STATE IF NEW OR EXISTING | | | EQUIPMENT. | | | | | | 3) ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | | ACCOMPANYING DATA SHALL BEAR THE PRINTED NAME AND | | | SIGNATURE OF THE PERSON RESPONSIBLE FOR THE DESIGN. PER | | | FBC 104.2.1 . | | | | | | 4) SEE PLANS THE TWO YELLOW HIGH LIGHTED SUPPLY AIR | | | DUCTS NEED TO BE SIZED. | | | | | | 5) SEE PLANS THE ROOM NEXT TO HER CLOSET IN THE MASTER | | | SUITE IS NOT LABELED AND MAY NEED RETURN AIR PROVIDED | | | FOR. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-03-13 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-13 |
Time |
08:47 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-03-13 |
Time |
08:47 |
Sent To |
|
|
| Notes |
| 2007-03-13 09:03:29 | *** DENIED *** | | | 1) DOCUMENTS SUBMITTED ARE PIECES OF PAPER CUT FROM A | | | PLAN, PLEASE SUBMIT A PLAN WITH ALL PERTINENT | | | INFORMATION ON IT, SEE 2004 FBC 106.1.1. | | | | | | *** 2004 FBC 106.1.1 INFORMATION ON CONSTRUCTION | | | DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | 2)ENERGY CALCULATIONS NEED TO BE SIGNED BY | | | OWNER/AGENT ALSO, PER 2004 FBC 13-600.3.ABC.2. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|