Plan Review Details - Permit 07030165
Plan Review Stops For Permit 07030165
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-05-08 Cont ID  
Sent By shill Date 2007-05-08 Time 10:23 Rev Time 0.00
Received By shill Date 2007-05-08 Time 10:23 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-04-30 Cont ID  
Sent By shill Date 2007-04-30 Time 08:32 Rev Time 0.00
Received By shill Date 2007-04-30 Time 08:32 Sent To I
Notes
2007-04-30 08:37:03NEEDS ZONING

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-03-26 Cont ID  
Sent By shill Date 2007-03-26 Time 17:28 Rev Time 0.00
Received By shill Date 2007-03-26 Time 17:28 Sent To Z
Notes
2007-03-26 17:31:21****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING
 CODE
 FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL
 FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE
 FBC2004
 FACFLORIDA ADMINISTRATIVE CODE
 FSFLORIDA STATUTE
  
 1.)REVISE THE APPLICATION TO CORRECTLY REFLECT THE
 SCOPE OF WORK.IT STATES THAT YOU ARE BUILDING A
 FAMILY ROOM, BUT THIS IS NOT INTERIOR SPACE.
  
 2.)TWO PRODUCT APPROVALS REQUIRED FOR THE ROOF, ONLY
 ONE SUBMITTED.
  
 3.)PRODUCT APPROVALS ARE TO BE APPROVED BY DESIGNER
 OF RECORD, FBC*106.3.3.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-03-13 Cont ID  
Sent By shill Date 2007-03-13 Time 12:33 Rev Time 0.00
Received By shill Date 2007-03-12 Time 15:50 Sent To  
Notes
2007-03-13 12:33:49****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004 WITH 2006 AMENDMENTS FBC
 R FLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* WITH 2006
 AMENDMENTS
 CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 1.)THE PLANS STATE "TRUSS" WITH DETAILS.TRUSS
 DESIGN AND MANUFACTURE SHALL COMPLY WITH FBC R802.1.6.
  
 2.)TRUSS DESIGN DRAWINGS ARE TO INCLUDE ALL
 INFORMATION REQUIRED BY FBC R802.1.6.1.TRUSS
 ENGINEERING IS NOT REQUIRED AT THIS TIME BUT MAY HELP
 TO SHOW CODE COMPLIANCE.PLANS ARE TO STATE DESIGN
 CRITERIA FOR THE TRUSSES.PLEASE INCLUDE DESIGN WIND
 SPEED AND EXPOSURE CATEGORY, SLOPE, DESIGN LOADS
 802.1.6.1(5), LUMBER SIZE AND SPECIES, CONNECTION
 REQUIREMENTS, CONNECTOR LIMITATIONS FROM MANUFACTURER,
 FASTENING (SIZE AND NUMBER OF FASTENERS).
  
 3.)TRUSSES SHALL BE CONNECTED TO WALL PLATES BY THE
 USE OF APPROVED CONNECTORS HAVING A RESISTANCE TO
 DESIGN UPLIFT, LATERAL AND SHEAR FORCES.STATE DESIGN
 CRITERIA AND SHOW COMPLIANCE.
  
 4.)THE APPLICATION STATES THAT YOU ARE RECONSTRUCTING
 A FAMILY ROOM, WHICH IMPLIES WORK ON AN ENCLOSED ROOM
 ATTACHED TO THE RESIDENCE, BUT THE PLAN SUBMITTED SHOWS
 A FREE STANDING OPEN STRUCTURE.SHOW EXISTING
 CONDITIONS AS WELL AS THE PROPOSED IMPROVEMENT.THE
 FLOOR PLAN IS TO SHOW THE LOCATION OF THIS IMPROVEMENT
 IN RELATION TO THE BUILDING.PROVIDE A FLOOR PLAN OF
 THE BUILDING, WITH ROOM DESIGNATIONS, ADJACENT TO THIS
 IMPROVEMENT.THE PLAN SHOULD CLEARLY SHOW HOW EGRESS,
 ESPECIALLY FROM BEDROOMS, WILL BE AFFECTED BY THIS
 IMPROVEMENT (OR SHOW THAT IT WILL NOT BE AFFECTED).
  
 5.)FBC*106.3.5, MINIMUM PLAN REVIEW CRITERIA FOR
 BUILDINGS, SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA
 AND DOCUMENTS; A FLOOR PLAN, SITE PLAN, FOUNDATION
 PLAN, FLOOR/ROOF FRAMING PLAN OR TRUSS LAYOUT; AND ALL
 EXTERIOR ELEVATIONS.
  
 6.)ARE THE COLUMNS PROPOSED OR EXISTING?PROVIDE A
 STRUCTURAL DETAIL, CONTINUOUS FROM THE FOUNDATION
 THROUGH THE ROOF.
  
 7.)FBC*106.1.3, BUILDING PLANS ARE TO BE DRAWN TO A
 MINIMUM OF 1/8? SCALE.NO SCALE SHOWN.
  
 8.)STATE DESIGN CRITERIA FBC R101.1.NO WIND DESIGN
 CRITERIA WAS PROVIDED.ALSO STATE OTHER APPLICABLE
 DESIGN CRITERIA SUCH AS DEAD LOADS, LIVE LOADS, ROOF
 LOADS.
  
 9.)AS THE PLAN WAS DRAWN IN 3 DIMENSION RATHER THAN
 PLAN VIEW AND ELEVATIONS, THE DETAILS ARE NOT CLEAR.
 THE PAGES ARE NOT NUMBERED OR LABELED IN ANY WAY.IT
 IS DIFFICULT TO GIVE A DETAILED LIST AS I?M NOT SURE
 HOW TO CONVEY TO YOU WHICH DETAIL OR SHEET I?M
 REFERRING TO.WHEN RESUBMITTING PLANS ARE TO BE
 ARCHITECTURAL QUALITY, TO SCALE, WITH ALL INFORMATION
 REQUESTED IN ITEM 5 ABOVE.
  
 10.) THE SECOND SHEET SHOWS "BEAM BASE".NO DIMENSIONS
 WERE PROVIDED OTHER THAN 51/2", WHAT IS THE WIDTH?
 LUMBER HAS TWO DIMENSIONS (SUCH AS 2X4).IT SHOWS A
 LAG SCREW BUT DOES NOT STATE WHERE THE LAG SCREW WILL
 BE INSTALLED.IT SHOWS A SCREW HOLDING THE BEAM ONTO
 THE COLUMN, BUT UPLIFT IS NOT ADDRESSED.IT ALSO SHOWS
 SCREWS ATTACHING A NOTCHED BEAM TO ANOTHER BEAM.IS
 THE SAME SCREW FOR BOTH?ONE IS GOING INTO CONCRETE,
 ONE INTO WOOD.IF THE BEAM DEPTH IS 5 1/2", AND THE
 SCREW IS 5 1/2", IT SEEMS THAT THE SCREW WOULDN'T BE
 GOING INTO ANYTHING.
  
 THE CROSS MEMBERS APPEAR TO BE GOING UP.THIS DETAIL
 IS NOT CLEAR.THE FIRST SHEET SEEMS TO SHOW A BEAM
 SPANNING 13 FEET, ANOTHER BEAM WHICH GOES THE OTHER
 DIRECTION WITH NO SPAN BETWEEN COLUMNS GIVEN.IT IS
 NOT CLEAR HOW THE TWO BEAMS ARE CONNECTED STRUCTURALLY.
 I CANNOT DETERMINE HOW THE SECOND SHEET RELATES TO THE
 FIRST SHEET AS IT SEEMS TO BE GOING ACROSS THE 13 FOOT
 SPAN, BUT WHERE DO THE TRUSSES SIT?NO INFORMATION IS
 PROVIDED AS TO HOW THE TRUSSES WILL CONNECT TO THE
 BEAM.
  
 THE SHEET MARKED ?TRUSS? IS NOT CLEAR.DRAWINGS FOR A
 TRUSS SYSTEM MUST BE REVIEWED PRIOR TO INSTALLATION
 FBC802.1.6 AND ARE NOT REQUIRED AT THIS TIME.HOWEVER,
 SUBMITTAL OF THE TRUSS ENGINEERING MAY ASSIST IN
 SHOWING CODE COMPLIANCE FOR THIS PROJECT.
  
 11.)ROOF SHEATHING IS TO COMPLY WITH FBC R 803.
 PLEASE SPECIFY SHEATHING AND FASTENING.NOTE THAT NO
 SHEATHING IS SHOWN ON THE PLAN BUT THE APPLICATION
 STATES "COVER PLYWOOD".PLANS ARE TO SHOW ALL DETAILS
 AND COMPONENTS TO BE INSTALLED.
  
 12.)NO ROOF IS SHOWN ON THE PLAN, BUT YOU HAVE
 REQUESTED A ROOF PERMIT.PLEASE SPECIFY ROOFING
 MATERIAL ON THE PLAN.
  
 13.)TWO SETS OF ALL DOCUMENTS REQUIRED.ONLY ONE
 PRODUCT APPROVAL SUBMITTED.

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-04-30 Cont ID  
Sent By adarroug Date 2007-04-30 Time 09:46 Rev Time 0.00
Received By adarroug Date 2007-04-30 Time 09:46 Sent To Z
Notes
2007-04-30 09:46:36TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-04-23 Cont ID  
Sent By adarroug Date 2007-04-23 Time 14:36 Rev Time 0.00
Received By adarroug Date 2007-04-23 Time 14:36 Sent To B
Notes
2007-04-23 14:37:06TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-03-25 Cont ID  
Sent By adarroug Date 2007-03-25 Time 11:28 Rev Time 0.00
Received By adarroug Date 2007-03-25 Time 11:28 Sent To B
Notes
2007-03-25 11:29:24TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-03-13 Cont ID  
Sent By shill Date 2007-03-13 Time 13:11 Rev Time 0.00
Received By shill Date 2007-03-07 Time 10:53 Sent To  
Notes
2007-03-07 10:54:08TO "SHILL" DESK/PER "RBROWN"

Review Stop Z ZONING
Rev No 2 Status P Date 2007-05-04 Cont ID  
Sent By jroach Date 2007-05-04 Time 08:33 Rev Time 0.00
Received By jroach Date 2007-05-04 Time 08:33 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status F Date 2007-04-02 Cont ID  
Sent By jroach Date 2007-04-02 Time 11:00 Rev Time 0.00
Received By jroach Date 2007-04-02 Time 11:00 Sent To I
Notes
2007-04-02 11:06:27***FAILED***
  
 1) SCOPE OF WORK SHALL MATCH THE SUBMITTED PLANS.THE
 SCOPE INDICATES THE CONSTRUCTION OF A FAMILY ROOM,
 WHILE THE DRAWINGS SHOW THE CONSTRUCTION OF A
 FREE-STANDING OPEN STRUCTURE.
  
 2) TWO (2) COPIES OF A SURVEY SHALL BE PROVIDED SHOWING
 THE LOCATION OF THE PROPOSED STRUCTURE/ADDITION.
 SETBACKS SHALL BE PROVIDED ON BOTH COPIES SHOWING THE
 DISTANCE FROM THE STRUCTURE/ADDITION TO ALL PROPERTY
 LINES.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER,
 AT (561) 822-1435.