| Plan Review Stops For Permit 07020773 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2008-01-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2008-01-03 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2008-01-03 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2008-01-03 14:42:06 | **PROVISO**SUBMIT RAILING SHOPS FOR REVIEW PRIOR TO | | | INSTALLATION |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-10-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2007-10-30 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-10-30 |
Time |
15:24 |
Sent To |
|
|
| Notes |
| 2007-10-30 15:30:02 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* | | | CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | | FACFLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | | | | 1.)ADDRESSED. | | | | | | 2.)THE PERMIT FOR THE ROOF FRAMING, SHEATHING, AND | | | FLOOR FRAMING IS EXPIRED, AS WELL AS THE WINDOW AND | | | DOOR PERMIT (04070723, 04050602).INCLUDE THIS SCOPE | | | OF WORK IN THIS PERMIT AND IN THE VALUE. | | | | | | 3.-8.)ADDRESSED. | | | | | | 9.)USE OF REMOVABLE SHUTTERS ON COMMERCIAL BUILDINGS | | | REQUIRES APPROVAL BY THE BUILDING OFFICIAL, SEE | | | ATTACHED POLICY, ITEM 13.PROVIDE A PRE STORM | | | INSTALLATION PLAN INCLUDING ALL INFORMATION IN THE | | | POLICY.THIS PROCESS MAY (AND SHOULD) BE COMPLETED | | | SEPARATELY FROM THE RESUBMITTAL.A DRAFT MAY BE | | | SUBMITTED VIA EMAIL. | | | | | | 10-16.)ADDRESSED. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-04-29 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-04-29 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2007-04-29 |
Time |
10:57 |
Sent To |
FIRE |
|
| Notes |
| 2007-04-29 10:59:12 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | | 561-805-6724 [email protected] | | | | | | FBCFLORIDA BUILDING CODE 2004 | | | FBC EBFLORIDA BUILDING CODE 2004 EXISTING BUILDING | | | CODE | | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | FBC*CITY OF WEST PALM BEACH AMENDMENTS TO THE | | | FBC2004 | | | FACFLORIDA ADMINISTRATIVE CODE | | | FSFLORIDA STATUTE | | | | | | | | | | | | 1.)SEE ATTACHED.THERE IS A BALANCE OF $2883.60 FROM | | | A 4X PLAN REVIEW FEE ONPERMIT APPLICATION 03111034. | | | SEE NOTES REGARDING THIS FEE ON THE FRONT SCREEN OF | | | PERMIT 03111034.THIS FEE MUST BE PAID WHEN | | | RESUBMITTING. | | | | | | 2.)THE PERMIT FOR THE ROOF FRAMING, SHEATHING, AND | | | FLOOR FRAMING IS EXPIRED, AS WELL AS THE WINDOW AND | | | DOOR PERMIT (04070723, 04050602).INCLUDE THIS SCOPE | | | OF WORK IN THIS PERMIT AND IN THE VALUE. | | | | | | 3.)ENERGY CALCS WERE SUBMITTED.FORM 600 A-01 WAS | | | USED.GOVERNING CODE IS FBC2004, PLEASE SEE FBC13 AND | | | USE THE CORRECT FORM. | | | | | | 4.)ENERGY CALCS REQUIRED FOR THE FIRST FLOOR ALSO, | | | WHICH IS NOT RESIDENTIAL, FBC13-101.1, FBC13-202, FBC | | | EB 708.1.ENERGY CALCS REQUIRED FOR SHELL BUILDINGS, | | | FBC13-101.2. | | | | | | 5.)DECLARE LEVEL OF ALTERATION, FBC EB CHAPTER 3. | | | | | | 6.)INCLUDE A CODE SUMMARY; BUILDING TYPE FBC6, | | | BUILDING HEIGHT AND AREA FBC5, SPRINKLER INFORMATION, | | | OCCUPANCY CLASSIFICATION FBC 3 AND AREA PER OCCUPANCY. | | | | | | 7.)THE PLANS DO NOT PROVIDE ENOUGH INFORMATION TO | | | DETERMINE CODE COMPLIANCE.FOR INSTANCE, SHEET 1 SHOWS | | | A 5? AND 10? DISTANCE TO DOTTED LINES.IF THIS IS AN | | | ASSUMED PROPERTY LINE, YOU NEED TO SHOW THE ADJACENT | | | BUILDINGS AND THEIR DISTANCE TO THE PROPERTY LINE AS | | | WELL AS BUILDING TYPE AND OCCUPANCY.A NOTE ON SHEET 2 | | | STATES THAT THESE WALLS EXCEED 1 HOUR FIRE RATING, BUT | | | COMPLIANCE WITH FBC TABLE 704.8 (0 UNPROTECTED OPENINGS | | | PERMITTED), FBC TABLE 503, FBC TABLES 601, 602 HAS NOT | | | BEEN SHOWN.PLEASE CONTACT ME IF YOU NEED ASSISTANCE. | | | | | | | | | 8.)INFORMATION WAS NOT PROVIDED FOR THE FIRST FLOOR. | | | THE BOARD ORDER WAS TO BRING THE ENTIRE BUILDING UP TO | | | 100% CODE COMPLIANCE.AREN?T THERE WINDOWS, DOORS, | | | ETC. ON THE FIRST FLOOR?IT IS UNDERSTOOD THAT THIS | | | WILL BE A SHELL BUT CODE COMPLIANCE FOR THE SHELL MUST | | | BE ON THE PLAN; EGRESS, INCLUDING ACCESSIBLE | | | ENTRANCE/EXIT FBC 13.NOTHING WAS SHOWN ON THE PLAN. | | | | | | | | | 9.)USE OF REMOVABLE SHUTTERS ON COMMERCIAL BUILDINGS | | | REQUIRES APPROVAL BY THE BUILDING OFFICIAL, SEE | | | ATTACHED POLICY, ITEM 13.PROVIDE A PRE STORM | | | INSTALLATION PLAN INCLUDING ALL INFORMATION IN THE | | | POLICY.THIS PROCESS MAY (AND SHOULD) BE COMPLETED | | | SEPARATELY FROM THE RESUBMITTAL.A DRAFT MAY BE | | | SUBMITTED VIA EMAIL. | | | | | | 10.)PROVIDE A DETAIL FOR THE STAIR GUARDRAIL/HANDRAIL | | | ON THE OPEN SIDE, FBC1012, 1009, 1009.11.1 EXCEPTION. | | | | | | 11.)SEE FBC 1019.1.5 REGARDING STORAGE UNDER THE | | | STAIRS AND SHOW COMPLIANCE ON THE PLAN. | | | | | | 12.)THE FIRST RISER FOR THE STAIRS (SHEET 8) IS SHOWN | | | AT 4?.SEE FBC1009.3.1, DIMENSIONAL UNIFORMITY. | | | | | | 13.)DESIGN PRESSURES FOR COMPONENTS AND CLADDING ARE | | | NOT ON THE PLAN; PLEASE PROVIDE.ALSO PROVIDE WIND | | | DESIGN CRITERIA FBC1603.1.4. | | | | | | 14.)A COMPLETE REVIEW OF PRODUCT APPROVALS CANNOT BE | | | DONE WITHOUT DESIGN PRESSURES.HOWEVER, PLEASE NOTE | | | THE FOLLOWING: | | | | | | A. THE STEEL DOOR IS INSWING, BUT OUTSWING IS SHOWN ON | | | THE PLAN FOR THE SECOND FLOOR.NO INFORMATION PROVIDED | | | FOR THE FIRST FLOOR.THIS DOOR IS NOT APPROVED WHERE | | | WATER INFILTRATION IS REQUIRED.IT IS NOT CLEAR WHERE | | | THIS DOOR WILL BE INSTALLED. | | | | | | B. THE SINGLE HUNG WINDOW IS SMALL MISSILE IMPACT | | | RATED.LARGE MISSILE IS REQUIRED, FBC1609.1.4(1). | | | | | | C. SUBMIT PRODUCT APPROVALS FOR THE WINDOWS FOR THE | | | FIRST FLOOR. | | | | | | D. EITHER COMPLETE THE SAMPLE INSTALLATION SCHEDULE | | | (LAST PAGE OF THE POLICY) OR PROVIDE ALL INFORMATION IN | | | ANOTHER FORMAT. | | | | | | 15.)SEE FBC1023.3 AND SHOW COMPLIANCE (DISTANCE OF | | | STAIRS TO OTHER BUILDINGS). | | | | | | 16.)PROVIDE A COPY OF THE SURVEY FOR THIS PROPERTY. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2007-12-28 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-12-28 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-12-28 |
Time |
14:42 |
Sent To |
|
|
| Notes |
| 2007-12-28 14:49:28 | | | | | | | PREVIIOUSLY REVIEWED/PASSED PLANS IN THIS SET./WRT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-10-24 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-10-24 |
Time |
14:51 |
Rev Time |
0.00 |
| Received By |
btrobaug |
Date |
2007-10-24 |
Time |
14:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2007-03-08 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-03-08 |
Time |
10:20 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-03-08 |
Time |
10:05 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2008-01-03 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2008-01-03 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2008-01-03 |
Time |
12:40 |
Sent To |
|
|
| Notes |
| 2008-01-03 12:58:36 | *****APPROVED***** | | | | | | | | | PLANS SHEETS 2, 3, AND 8 WERE STAMPED, INITIALED, AND | | | DATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-10-30 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-10-30 |
Time |
15:56 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-10-30 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2007-10-30 16:00:58 | ***APPROVED/PROVISO | | | | | | 1) OK | | | | | | 2) OK | | | | | | 3) OK | | | | | | 4) ILLUSTRATE ADDRESS ON DRAWINGS OR ADD NOTE. | | | | | | 5) PLANS STILL SHOW SMOKE DETECTORS. PLEASE MAKE | | | APPROPRIATE CORRECTION ON DRAWINGS. | | | | | | 6) OK | | | | | | 7) OK | | | | | | | | | PLANS WERE PASSED WITH PROVISO AND WILL BE STAMPED WHEN | | | RESUBMITTED FOR CORRECTIONS. | | | | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | | FIRE PLAN REVIEW | | | FIRE PREVENTION (561) 804-4756 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-06-04 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-06-04 |
Time |
14:30 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-06-04 |
Time |
12:18 |
Sent To |
|
|
| Notes |
| 2007-06-04 14:30:17 | *****DENIED***** | | | | | | | | | 1.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 2.COMBUSTIBLE WASTE MATERIALS, DUST, AND DEBRIS SHALL | | | BE REMOVED FORMTHE SITE AT THE END OF EACH SHIFT OR | | | MORE FREQUENTLY AS NECESSARY FOR SAFE OPERATION. | | | | | | 3.THE DEMOLITION, RENOVATION, OR CONSTRUCTION | | | OPERATIONS SHALL NOT HINDER OF INTERFERE WITH EMERGENCY | | | RESPONSE ACCESS TO THE SAID PROPERTY OR VICINITY | | | THEREOF (INCLUDING STREETS, ROADS ALLEYS, FIRE LANES). | | | | | | 4.ON THE APPROPIATE EXTERIOR ELEVATION FRONTING 7TH | | | STREET, DISPLAY THE NUMERICAL ADDRESS FOR THIS | | | STRUCTURE.AS PER WEST PALM BEACH CODE, THOSE NUMBERS | | | SHALL BE NO LESS THAN 6" IN HEIGHT AND NO LESS THAN 1" | | | IN WIDTH. | | | | | | 5.ON PLAN SHEET 3, IT IS NOTICED THAT A SMOKE | | | DETECTOR (SD) IS LOCATED IN EACH OF THE BEDROOMS, | | | WHEREAS A SMOKE ALARM (SA) IS LOCATED IN THE LIVING | | | ROOM AND DINING ROOM.PLEASE BE ADVISED THAT SMOKE | | | DETECTORS (SD) ARE TIED INTO A FIRE ALARM SYSTEM. | | | | | | 6.IT IS NOTED ON SHEET 9 OF THE INTENT OF | | | CONSTRUCTING A CBS WALL TO CREATE A STORAGE ROOM. | | | PLEASE BE ADVISED THAT ROOMS OR SPACES FOR STORAGE | | | (UNDERNEATH A EXIT STAIR) OF COMBUSTIBLE SUPPLIES AND | | | EQUIPMENT SHALL BE SPRINKLERERED OR HAVE A 1 HOUR FIRE | | | SEPARATION. | | | | | | 7.SPECIFY THE INTERIOR WALL AND CEILING FINISH | | | CLASSIFICATION IN THE EXITS, EXIT ACCESS CORRIDORS, AND | | | ALL OTHER SPACES AS CLASS A, CLASS B, OR CLASS C. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH ITEM WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEW | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-12-21 |
|
|
Cont ID |
|
| Sent By |
mmiller |
Date |
2007-12-21 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-12-26 |
Time |
15:43 |
Sent To |
|
|
| Notes |
| 2007-12-26 15:43:22 | TO "BOB" # 5 | | 2007-12-21 16:31:02 | WAITING FOR BOB MMILLER |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-10-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-10-12 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-10-12 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2007-10-19 08:35:28 | TO "BOB"#10 | | 2007-10-12 09:52:45 | WAITING FOR "BOB" |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-06-04 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-06-04 |
Time |
12:18 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-03-01 |
Time |
14:36 |
Sent To |
|
|
| Notes |
| 2007-03-01 15:01:05 | TO "E" BOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-12-27 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-12-27 |
Time |
11:32 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-12-27 |
Time |
11:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2007-10-19 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-10-19 |
Time |
15:33 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-10-19 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2007-10-19 16:06:25 | PLAN REVIEW UNDER THE 2004 FLORIDA BUILDING CODE & | | | REFERENCED CODES WITH 05, 06 REVISIONS, CITY OF WEST | | | PALM BEACH AMENDMENTS TO CHAPTER 1 (W.P.B.), FLORIDA | | | ADMINISTRATIVE CODE (F.A.C.), AND FLORIDA STATUTES | | | (F.S.). | | | | | | *** DENIED *** | | | 1) PLEASE SUBMIT ENERGY CALCULATIONSUSING FORM | | | 600A-04-"R" OR 600B-04-"R" OR 600C-04-"R", SEE 2004 FBC | | | 13-600.0, AND FBC/EXISTING 611.1. | | | | | | 2) WHEN RE-SUBMITTING HAVE THE NEW ENERGY CALCULATIONS | | | SIGNED BY OWNER/AGENT ALSO, PER 2004 FBC | | | 13-600.3.ABC.2. | | | | | | 3) THE CLOTHES DRYER VENT MAY NOT DISCHARGE ON TO THE | | | A/C CONDENSER UNIT, SEE 2004 FBC/M 501.2 AND FBC RES. | | | R303.4.2 . | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729 | | | E-MAIL; [email protected] |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2007-03-09 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-09 |
Time |
15:52 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-03-09 |
Time |
15:52 |
Sent To |
P |
|
| Notes |
| 2007-03-09 16:04:18 | *** DENIED *** | | | 1) ENERGY CALCULATIONS NEED TO BE ON FORM600A-04-R, | | | SEE 2004 FBC 13-600.3.A (12-8-06 REVISION). | | | | | | 2) WHEN RE-SUBMITTING HAVE THE NEW ENERGY CALCULATIONS | | | SIGNED BY OWNER/AGENT ALSO, PER 2004 FBC | | | 13-600.3.ABC.2. | | | | | | 3) THE CLOTHES DRYER VENT MAY NOT DISCHARGE ON TO THE | | | A/C CONDENSER UNIT, SEE 2004 FBC/M 501.2 . | | | | | | 4) THE 10" RETURN AIR TRANSFER DUCTS TO THE BEDROOMS | | | NEED TO BE 12". | | | *** 2004 FBC/R M1602.4 .BALANCED RETURN AIR MAY BE | | | ACHIEVED BY. | | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | | INCREASING THE RETURN TRANSFER ONE AND | | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | | (SQUARE INCHES) OF THE SUPPLY DUCT | | | ENTERING THE ROOM OR SPACE IT'S SERVING | | | AND THE DOOR HAVING AT LEAST AN | | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | | PROPER RETURN AIR BALANCE. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2008-01-02 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2008-01-02 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2008-01-02 |
Time |
16:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2007-10-31 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-10-31 |
Time |
09:19 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-10-31 |
Time |
09:19 |
Sent To |
PC |
|
| Notes |
| 2007-10-31 10:56:43 | DENIED 2ND TIME | | | REFERENCE: | | | ** FBC-2004 WITH 05 & 06 REVISIONS, PLUMBING. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | ** FLORIDA ADMINISTRATIVE CODE (FAC). | | | ** FLORIDA STATUTES (FS). | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | PLUMBING PLAN REVIEW TO MEET CODE COMPLIANCE ON THE | | | RESUBMITTED PLANS: | | | | | | 1. REFERENCE MECHANICAL COMMENTS #1 & 2 ON THE ENERGY | | | CALCULATIONS. | | | | | | 2. PER FBC-2004 CHAPTER 1, SECTION 106.3.5.1.3, | | | PLUMBING: AN ISOMETRIC POTABLE WATER RISER DIAGRAM IS | | | REQUIRED FOR BOTH THE HOT AND COLD WATER INDICATING THE | | | PIPE SIZES, VALVE LOCATIONS, LOCATION OF THE WATER | | | SUPPLY LINE WITH THE BACKFLOW PREVENTER **608, THERMAL | | | EXPANSION CONTROL **607.3FOR THE WATER HEATER, AND | | | THE LOCATION OF THE WATER-HAMMER ARRESTORS **604.9 | | | WHERE QUICK CLOSING VALVES ARE UTILIZED (WASHING | | | MACHINES, DISHWASHERS, ICE MAKERS). | | | | | | END OF COMMENTS: | | | | | | REVIEW BY: MIKE PERSON | | | PLUMBING PLANS EXAMINER | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL: [email protected] |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-03-12 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-03-12 |
Time |
15:25 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2007-03-12 |
Time |
15:25 |
Sent To |
B |
|
| Notes |
| 2007-03-12 16:08:09 | DENIED | | | REFERENCE: FBC-2004 PLUMBING; FBC-2004 CHAPTER 1, CITY | | | OF WEST PALM BEACH AMENDMENTS; | | | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING | | | PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. PER FBC-2004 CHAPTER 1, 106.1.1 INFORMATION ON | | | CONSTRUCTION | | | DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL | | | BE OF SUFFICIENT CLARITY TO INDICATE THE | | | LOCATION, NATURE AND EXTENT OF THE WORK | | | PROPOSED AND SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE | | | AND RELAVENT LAWS, ORDINANCES, RULES AND REGULATIONS, | | | AS DETERMINED BY THE | | | BUILDING OFFICIAL. | | | NOTE: THE SUBMITTED SANITARY ISOMETRIC RISER DIAGRAM ON | | | SHEET 7 DOES NOT REFLECT THE FLOOR PLAN. | | | A} PLEASE CORRECT AND RESUBMIT THE SANITARY RISER | | | DIAGRAM INDICATING THE DOUBLE BOWL KITCHEN SINK WITH | | | DISHWASHER AND THE CORRECT LOCATION OF THE LAVATORY OFF | | | BEDROOM #2. | | | | | | B} 406.3 WASTE CONNECTIONS.THE TRAP AND | | | FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES | | | WASHER SHALL BE A MINIMUM OF 2 INCHES | | | (51MM) IN DIAMETER. THE AUTOMATIC | | | CLOTHES WASHER FIXTURE DRAIN SHALL | | | CONNECT TO A BRANCH DRAIN OR DRAINAGE | | | STACK A MINIMUM OF 3 INCHES (76MM) IN | | | DIAMETER. | | | NOTE: PLEASE CORRECT THE BRANCH DRAIN AND STACK TO BE | | | THREE INCH (3") ON THE RESUBMITTAL. | | | | | | C} 802.4 STANDPIPES.STANDPIPES SHALL BE INDIVIDUALLY | | | TRAPPED. STANDPIPES SHALL | | | EXTEND A MINIMUM OF 18 INCHES (457MM) | | | AND A MAXIMUM OF 42 INCHES (1066MM) | | | ABOVE THE TRAP WEIR. ACCESS SHALL BE | | | PROVIDED TO ALL STANDPIPES AND DRAINS FOR RODDING. | | | NOTE: PLEASE INDICATE THE STANDPIPE ON THE | | | RESUBMITTAL. | | | | | | | | | D} 708.3.5 BUILDING DRAIN AND BUILDING | | | SEWER JUNCTION. THERE SHALL BE A | | | CLEANOUT NEAR THE JUNCTION OF THE | | | BUILDING DRAIN AND THE BUILDING SEWER. | | | NOTE: PLEASE INDICATE THE TWO-WAY CLEANOUT ON THE | | | RESUBMITTAL. | | | | | | E} 708.7 MINIMUM SIZE. CLEANOUTS SHALL | | | BE THE SAME NOMINAL SIZE AS THE PIPE | | | THEY SERVE UP TO 4 INCHES (102MM) | | | NOTE: CLEANOUT FOR THE WASHING MACHINE SHALL BE THREE | | | INCH (3"). PLEASE INDICATE THIS ON THE RESUBMITTAL. | | | | | | F} 708.9 ACCESS. ACCESS SHALL BE | | | PROVIDED TO ALL CLEANOUTS. | | | NOTE: CLEANOUT FOR THE WASHING MACHINE TO BE LOCATED AT | | | FOUR FEET ABOVE FINNISH FLOOR (4' A.F.F.). PLEASE | | | INDICATE THIS ON THE RESUBMITTAL. | | | | | | ********IMPORTANT INFORMATION | | | IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING, | | | PLEASE REPLACE ONLY SHEETS | | | WHICH HAVE CHANGED, PLEASE INCLUDE A | | | TRANSMITTAL LETTER INDICATING HOW EACH | | | ITEM WAS ADDRESSED AND PROVIDE ONE COPY | | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | | IN RED INK FOR REFERENCE FOR | | | RESUBMITTAL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | | | | |
|
|