| Plan Review Stops For Permit 07020689 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-07-23 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-07-23 |
Time |
13:28 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-07-23 |
Time |
13:15 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-04-03 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-04-03 |
Time |
07:32 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-04-03 |
Time |
06:01 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-03-07 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-03-07 |
Time |
14:58 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-03-06 |
Time |
17:21 |
Sent To |
|
|
| Notes |
| 2007-03-06 18:59:22 | BUILDING PLAN REVIEW | | | PERMIT: 07020689 | | | ADD: 1616 N. FLORIDA MANGO RD | | | CONT: JASO AND ASSOC. INC. | | | TEL: (561)347-0673 | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW 1ST | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2)FL S S 713.13 | | | NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF | | | THE COURT. | | | NOTE: 713.13(2) | | | IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS | | | NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE | | | RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: | | | 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT | | | THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | | | 3)) 110.2* W. P. B. ADMINISTRATIVE | | | CODE, INFORMATION THAT IS REQUIRED FOR | | | RECORD KEEPING & FOR CERTIFICATE OF | | | OCCUPANCY: | | | A) THE EDITION OFTHE CODE UNDER WHICH | | | THE PERMIT WAS ISSUED. | | | B) THE USE AND OCCUPANCY, IN ACCORDANCE | | | WITH THE PROVISIONS OF CHAPTER 3. | | | C) THE TYPE OF CONSTRUCTION AS DEFINED | | | IN CHAPTER 6, TABLE 601. | | | D) THE DESIGN OCCUPANT LOAD, SEE 1004. | | | E) IF AN AUTOMATIC SPRINKLER SYSTEM IS | | | PROVIDED, WHETHER THE SPRINKLER SYSTEM | | | IS REQUIRED. | | | ) NUMBER OF UNITS | | | ) NUMBER OF FLOORS | | | ) NUMBER OF ROOMS | | | ) SQ. FT. FOOTPRINT | | | ) SQ. FT. UNDER ROOF (TOTAL) | | | ) OCCUPANT LOAD | | | ) FLOOD ZONE | | | | | | 4)INDICATE CLEARLY ON THE DRAWINGW THE PROPOSED WORK | | | AREAAND DESCRIBE IN DETAIL WHAT WORK WILL BE CARRIED | | | OUT. SHOW ON THE DRAWINGS WHICH WALLS ARE EXISTING AND | | | WHICH ONES ARE NEW. IF THERE WILL BE ANY DEMOLITION | | | INDICATE ON THE PLANS. WILL THE BATHROOMS FIXTURES BE | | | REPLACE ETC. THIS INFORMATION IS VERY IMPORTANT FOR | | | PLAN REVIEW. CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE AND | | | EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT IT | | | WILL CONFORM TO THE | | | | | | 5)WPB AMENDMENTS 108.3*THE VALUE IS TO LOW. IF IN | | | THE OPINION OF THE BUILDING OFFICIAL, THE CLAIMED | | | VALUATION OF THE BUILDING, ALTERATION, STRUCTURE, | | | ELECTRICAL, GAS, MECHANICAL OR PLUMBING SYSTEMS APPEARS | | | TO BE UNDERESTIMATED ON THE APPLICATION, THE PERMIT | | | SHALL BE DENIED. FOR PERMITTING PURPOSES, VALUATION OF | | | BUILDINGS AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT | | | VALUE OF THE PROJECT. | | | | | | 6)PROVIDE THE EXISTING AND PROPOSED FLOOR PLAN OF THE | | | PROJECT. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2007-05-22 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-05-22 |
Time |
12:04 |
Rev Time |
0.50 |
| Received By |
btrobaug |
Date |
2007-05-22 |
Time |
11:44 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2007-05-03 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-05-03 |
Time |
14:40 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2007-04-30 |
Time |
07:06 |
Sent To |
PC |
|
| Notes |
| 2007-05-03 14:39:53 | | | | | | | REVISION DENIED | | | | | | THIS WAS A PROVISO ON THE PERMITTED SET AND FAILED TO | | | GET ADDRESSED ON THE REVISION. | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1}INDICATE COMPLIANCE WITH 13-415.1ABC.1.2, FBC FOR | | | SPACE CONTROLS FOR LIGHTING." STANDARD"SWITCHES ARE | | | SHOWN ON THE PLAN. THE SUBMITTALS WERE RECEIVED IN THE | | | RESUB PACKAGE, BUT THE SENSORS NEED TO BE LOCATED ON | | | THE PLAN.SHOW COMPLIANCE ON THE DRAWING. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2007-04-05 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-04-05 |
Time |
15:14 |
Rev Time |
0.75 |
| Received By |
btrobaug |
Date |
2007-04-05 |
Time |
13:19 |
Sent To |
|
|
| Notes |
| 2007-04-05 15:14:06 | | | | | | | PROVISO | | | | | | THIS PERMIT IS BEING ISSUED TO | | | FACILITATE THE REPAIR OF THIS BUILDING | | | THE PLANS HOWEVER ARE INCOMPLETE. PLEASE | | | RESUBMIT A REVISION SHOWING ACTUAL | | | CONDITIONS PRIOR TO CALLING ROUGH | | | ELECTRICAL INSPECTION. | | | THE REVIEWED PLAN MUST BE ON THE JOB | | | SITE AT TIME OF INSPECTION. ALLOW AT | | | LEAST ONE WEEK (PER TRADE) FOR PLAN | | | REVIEW. | | | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | | COMPLIANCE AND RESUBMIT FOR REVIEW. | | | | | | 1}INDICATE COMPLIANCE WITH 13-415.1ABC.1.2, FBC FOR | | | SPACE CONTROLS FOR LIGHTING." STANDARD"SWITCHES ARE | | | SHOWN ON THE PLAN. THE SUBMITTALS WERE RECEIVED IN THE | | | RESUB PACKAGE, BUT THE SENSORS NEED TO BE LOCATED ON | | | THE PLAN.SHOW COMPLIANCE ON THE DRAWING. | | | | | | 2} THE DISCONNECT LOCATIONS FOR THE CONDENSING UNITS DO | | | NOT COMPLY WITH THE 3' CLEARANCE REQUIREMENTS OF | | | 110.26, NEC. | | | | | | 3} THE UTILITY RECEPTACLE CIRCUIT (#PA-20) FOR THE | | | CONDENSING UNITS WAS OMITTED FROM THE PANEL SCHEDULE. | | | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2007-03-06 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-03-06 |
Time |
09:06 |
Rev Time |
2.00 |
| Received By |
btrobaug |
Date |
2007-03-02 |
Time |
07:25 |
Sent To |
|
|
| Notes |
| 2007-03-05 13:45:41 | | | | DENIED/INCOMPLETE INFORMATION | | | | | | THIS REVIEWING IS BASED ON THE OPINION THAT ALL THE | | | ELECTRICAL SYSTEMS AND EQUIPMENT ON THE PLAN IS NEW AS | | | THERE IS NOTHING IN THE DESCRIPTION ON THE APPLICATION, | | | OR NOTES ON THE PLAN INDICATING OTHERWISE. | | | | | | 1} PLEASE LOCATE ALL SERVICE EQUIPMENT ON THE PLAN, | | | METER ENCLOSURE, DISCONNECTS AND PANELS, SO THAT | | | COMPLIANCE WITH ARTICLES 225 AND 230 CAN BE REVIEWED. | | | THE PANELS ARE MARKED "MLO", INDICATE THE LOCATION OF | | | THE DISCONNECTING MEANS. SEE 408.36. | | | | | | 2}PROVIDE A RISER DIAGRAM WITH CONDUCTOR AND CONDUIT | | | SIZE AND TYPE, GROUNDING DETAILS PER 215.5.. THE "ONE | | | LINE "DIAGRAM SUBMITTED DOES NOT HAVE ENOUGH | | | INFORMATION. | | | | | | 3} GIVE AMPERE RATING FOR THE PANELS. 215.5 | | | | | | 4} THE PANEL SCHEDULES ARE LABELED "PA AND "PC", THE | | | PANELS AND CIRCUITS ARE LABELED "PA" AND "PB". PLEASE | | | CORRELATE. | | | | | | 5} THE LIGHTING CIRCUIT IN SUITE 1, OFFICE 105, IS | | | MISMARKED "PB-18" | | | | | | 6} THE WATER COOLERS SHOWN IN BOTH SUITES ON SHEET E1, | | | ARE NOT LISTED ON THE PANEL SCHEDULES. SEE 210.23(A)(2) | | | FOR REQUIREMENTS. | | | | | | 7} PLEASE COMPLETE NOTE #7 , OR USE AS A CONTINUATION | | | OF NOTE #6. | | | | | | 8} CONDENSER #1, CIRCUIT 5,7 AND #2, CIRCUIT 8,10, | | | PANEL "PA" INDICATE A 10 AMP LOAD (2500 WATTS) | | | PROTECTED BY A 60 AMP BREAKER. THIS EXCEEDS THE | | | PARAMETERS OF 440.22 FOR OCP. | | | | | | 9} THE AHU CIRCUITS IN PANEL "PA" ARE IN VIOLATION OF | | | 424.3(B). SEE ALSO 240.4, REFERENCED IN SAME. THE | | | WATTAGE OF THESE UNITS DOES NOT CORRESPOND TO THE | | | SPECIFICATIONS ON SHEET M1. PLEASE CORRELATE | | | | | | 10} SHOW THE LOCATION REQUIRED DISCONNECTS PER 440.14, | | | ANDRECEPTACLE PER 210.63 FOR THE CONDENSING UNT, | | | SHEET E1. | | | | | | 11}THE PANEL LABELED "PC", CIRCUIT PB 4,6 AT THE | | | RECEPTACLE, INDICATES A 60 AMP OCP FOR A 3300 WATT A/C | | | LOAD IN VIOLATION OF 240.4. | | | | | | 12}INDICATE COMPLIANCE WITH 13-415.1ABC.1.2, FBC FOR | | | SPACE CONTROLS FOR LIGHTING." STANDARD SWITCHES ARE | | | SHOWN ON THE PLAN.SHOW COMPLIANCE ON THE DRAWING. | | | | | | 13} INDICATE COMPLIANCE WITH 13-415.2ABC.1, PERFORMANCE | | | CALCULATION PROCEDURES. SUBMIT FORMS WITH 13-415.2B OR | | | 13-415.2.C.1 DENSITIES. | | | | | | NOTE: IF THERE ARE ANY QUESTIONS REGARDING THE | | | REQUIREMENT TO COMPLY, PLEASE SEE 13.400.0.C.4, SECOND | | | PARAGRAPH. | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | | | BILL TROBAUGH | | | ELECTRICAL PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561/805-6718 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2007-04-03 |
|
|
Cont ID |
|
| Sent By |
mwennerg |
Date |
2007-04-03 |
Time |
10:39 |
Rev Time |
0.00 |
| Received By |
mwennerg |
Date |
2007-04-03 |
Time |
10:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2007-03-08 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-03-08 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-03-08 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2007-03-08 11:39:42 | ******DENIED***** | | | | | | | | | | | | 1.STRUCTURES UNDERGOING CONSTRUCTION, ALTERATION, OR | | | DEMOLITION OPERATIONS SHALL COMPLY WITH NFPA 241. | | | | | | 2.COMBUSTIBLE WASTE MATERIALS SHALL BE REMOVED FROM | | | THE SITE AT THE END OF EACH SHIFT OR MORE FREQUENTLY AS | | | NECESSARY FOR SAFE OPERATION. | | | | | | 3.THE DEMOLITION OF EXISTING AND/OR THE STOCKING OF | | | NEW BUILDING MATERIALS & SUPPLIES SHALL NOT INTERFERE | | | OR HINDER WITH EMERGENCY RESPONSE ACCESSTO THE | | | STRUCTURE OR THE VICINITY THEREOF (INCLUDING FIRE | | | LANES). | | | | | | 4.IT IS STATED ON SHEET A2 THAT THE MEANS OF EGRESS | | | FACTORS IS/ARE BASED ON NFPA 101 - 2006, HOWEVER , NFPA | | | 101- 2003 EDITION SHALL BE REFERENCED. | | | | | | | | | TO EXPEDITE THE PLAN REVIEW PROCESS, INCLUDE A RESPONSE | | | LETTER INDICATING HOW/WHERE EACH COMMENT WAS ADDRESSED | | | | | | | | | CAPT. MICHAEL A. WILLIAMS | | | FIRE PLAN REVIEM | | | 561-805-6722 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2007-07-30 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-30 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-30 |
Time |
09:17 |
Sent To |
B |
|
| Notes |
| 2007-07-30 09:17:35 | TO "MJACOBS" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2007-07-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-07-23 |
Time |
09:21 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-07-23 |
Time |
09:21 |
Sent To |
P |
|
| Notes |
| 2007-07-23 09:22:13 | TO "PSCHMITZ" DESK/SUBMITTAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2007-05-14 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-14 |
Time |
14:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-14 |
Time |
14:50 |
Sent To |
E |
|
| Notes |
| 2007-05-14 14:50:40 | TO "BTROBAUG" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-04-23 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-23 |
Time |
11:39 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-23 |
Time |
11:39 |
Sent To |
E |
|
| Notes |
| 2007-04-23 11:39:49 | TO "BTROBAUG" DESK/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-03-28 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-03-28 |
Time |
18:17 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-03-28 |
Time |
18:17 |
Sent To |
|
|
| Notes |
| 2007-03-28 18:18:07 | TO BOB # 8 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-03-08 |
|
|
Cont ID |
|
| Sent By |
mawillia |
Date |
2007-03-08 |
Time |
10:57 |
Rev Time |
0.00 |
| Received By |
mawillia |
Date |
2007-02-27 |
Time |
17:31 |
Sent To |
|
|
| Notes |
| 2007-02-27 17:32:06 | TO "BOB"#4 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2007-03-29 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-29 |
Time |
13:35 |
Rev Time |
0.25 |
| Received By |
tgordon |
Date |
2007-03-29 |
Time |
13:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2007-03-02 |
|
|
Cont ID |
|
| Sent By |
tgordon |
Date |
2007-03-02 |
Time |
13:40 |
Rev Time |
0.30 |
| Received By |
tgordon |
Date |
2007-03-02 |
Time |
13:40 |
Sent To |
|
|
| Notes |
| 2007-03-02 13:46:55 | *** DENIED *** | | | 1) PROVIDE FRESH AIR CALCULATIONS, PER 2004 FBC/M | | | 403.2. | | | | | | MECHANICAL PLAN REVIEW BY; | | | TOM GORDON (561) 805-6729. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2007-07-23 |
|
|
Cont ID |
|
| Sent By |
pschmitz |
Date |
2007-07-23 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
pschmitz |
Date |
2007-07-23 |
Time |
09:28 |
Sent To |
B |
|
| Notes |
| 2007-07-23 09:44:01 | AAV IN PLACE OF VTR |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2007-03-31 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-03-31 |
Time |
09:15 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-03-31 |
Time |
09:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2007-03-03 |
|
|
Cont ID |
|
| Sent By |
jleech |
Date |
2007-03-03 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
jleech |
Date |
2007-03-03 |
Time |
12:46 |
Sent To |
|
|
| Notes |
| 2007-03-03 13:06:24 | DENIED; | | | BOTTLED WATER COOLER MUST BE A DRINKING FOUNTAIN SEE | | | FBC-2004 PLUMBING SECTION 410.1. | | | PLUMBING PLAN REVIEW BY; | | | JOHN LEECH | | | 805-6695 |
|
|