Plan Review Details - Permit 07020619
Plan Review Stops For Permit 07020619
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-04-30 Cont ID  
Sent By mjacobs Date 2007-04-30 Time 06:03 Rev Time 0.00
Received By mjacobs Date 2007-04-28 Time 10:21 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-04-05 Cont ID  
Sent By mjacobs Date 2007-04-05 Time 15:42 Rev Time 0.00
Received By mjacobs Date 2007-04-05 Time 07:39 Sent To PC
Notes
2007-04-05 15:42:39BUILDING PLAN REVIEW
 PERMIT: 07020619
 ADD: 1369 9TH STREET
 CONT: RAMDEEN JACQUELINE
 TEL: (561)856-6655
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 1ST
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2)BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF
 THE COURT.
 NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS
 NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE
 RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE:
 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT
 THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION.
  
 4)106.3.3*THOSE PRODUCTYS WHICH ARE REGULATED BY
 THE CCA RULE 9B-72 SHALL BE REVIEWED AND APPROVED IN
 WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL. NOTE: THE PRODUCT APPROVAL
 FOR THE WINDOW IS MISSING FROM THE PACKAGE.
  
 5) FBC 106.1.1 CONSTRUCTION DOCUMENTS SHALL BE OF
 SUFFICIENT CLARITY TO INDICATE THE LOACTION, NATURE AND
 EXTENT OF THE WORK PROPOSED. PAGE #3 INDICATES A WOODEN
 STRUCTURE, HOWEVER, PAGE #7 INDICATES MASONRY BLOCK.
 STATE WHICH TYPE OF MATERIAL WILL BE USED FOR THE
 PROPOSED ADDITION.
  
 6)R802.1.6TRUSS DESIGN DRAWINGS, PREPARED IN
 CONFORMANCE WITH SEC.R802.1.6.1 SHALL BE PROVIDED TO
 THE BUILDING OFFICIAL AND APPROVED PRIOR TO
 INSTALLATION.
  
 7)SHOW A DETAIL DRAWING HOW THE NEW ROOF WILL TIE
 INTO THE EXISTING ROOF.
  
 8)R807.1 IN BUILDINGS WITH COMBUSTIBLE CEILING OR
 ROOF CONSTRUCTION, AN ATTIC ACCESS OPENING SHALL BE
 PROVIDED TO ATTIC AREA THAT EXCEED 30 SQUARE FEET AND
 HAVE A FERTICA HEIGHT OF 30 INCHES OR GRATER. THE ROUGH
 FRAMED OPENING SHALL NOT BE LESS THAN 22 INCHES BY 30
 INCHES.
  
 9)R806.1 ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES
 FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE
 UNDERSIDE OF ROOF RAFTERS SHALL HAVE CROSS VENTILATION
 FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS
 PROTECTED AGAINST THE ENTRANCE OF RAIN. INDICATE THIS
 REQUIREMENT ON THE ROOF FRAMINGDRAWINGS.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2007-03-07 Cont ID  
Sent By btrobaug Date 2007-03-07 Time 09:49 Rev Time 0.33
Received By btrobaug Date 2007-03-07 Time 09:38 Sent To M
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2008-03-10 Cont ID  
Sent By adarroug Date 2008-03-10 Time 11:07 Rev Time 0.00
Received By adarroug Date 2008-03-10 Time 11:07 Sent To B
Notes
2008-03-10 11:08:13TO "MJACOBS" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-04-26 Cont ID  
Sent By adarroug Date 2007-04-26 Time 08:55 Rev Time 0.00
Received By adarroug Date 2007-04-26 Time 08:55 Sent To P
Notes
2007-04-26 08:55:55TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-04-20 Cont ID  
Sent By adarroug Date 2007-04-20 Time 16:16 Rev Time 0.00
Received By adarroug Date 2007-04-20 Time 16:16 Sent To Z
Notes
2007-04-20 16:17:07TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-03-06 Cont ID  
Sent By adarroug Date 2007-03-06 Time 10:24 Rev Time 0.00
Received By adarroug Date 2007-03-06 Time 10:24 Sent To E
Notes
2007-03-06 10:24:39TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2007-04-05 Time   Rev Time 0.00
Received By adarroug Date 2007-02-27 Time 15:29 Sent To  
Notes
2007-02-27 15:30:07TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2007-03-07 Cont ID  
Sent By tgordon Date 2007-03-07 Time 14:45 Rev Time 0.25
Received By tgordon Date 2007-03-07 Time 14:45 Sent To P
Notes
2007-03-07 14:49:24*** PROVISO ***
 1) PROVIDE CLOTHES DRYER VENT TO OUT-DOORS, SEE 2004
 FBC/R M1501.1.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 2 Status P Date 2007-04-26 Cont ID  
Sent By mperson Date 2007-04-26 Time 15:19 Rev Time 0.33
Received By mperson Date 2007-04-26 Time 15:19 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2007-03-12 Cont ID  
Sent By mperson Date 2007-03-12 Time 14:42 Rev Time 0.33
Received By mperson Date 2007-03-12 Time 14:42 Sent To B
Notes
2007-03-12 14:55:28DENIED
 REFERENCE: FBC-2004 PLUMBING
  
 SHEET 12, SANITARY ISOMETRIC RISER DIAGRAM: THE
 FOLLOWING CORRECTIONS ARE REQUIRED FOR PLUMBING PLAN
 REVIEW TO MEET CODE COMPLIANCE:
 (A) 406.3 WASTE CONNECTIONS.THE TRAP AND
 FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES
 WASHER SHALL BE A MINIMUM OF 2 INCHES
 (51MM) IN DIAMETER. THE AUTOMATIC
 CLOTHES WASHER FIXTURE DRAIN SHALL
 CONNECT TO A BRANCH DRAIN OR DRAINAGE
 STACK A MINIMUM OF 3 INCHES (76MM) IN
 DIAMETER.
 NOTE: SIZE OF BRANCH DRAIN IS WRONG FOR WASHING
 MACHINE. PLEASE CORRECT AND RESUBMIT.
  
 (B) 708.7 MINIMUM SIZE. CLEANOUTS SHALL
 BE THE SAME NOMINAL SIZE AS THE PIPE
 THEY SERVE UP TO 4 INCHES (102MM)
 NOTE: CLEANOUT FOR WASHING MACHINE TO BE THREE INCH
 (3"). PLEASE INDICATE THIS ON THE RESUBMITTAL.
  
 (C) 708.9 ACCESS. ACCESS SHALL BE
 PROVIDED TO ALL CLEANOUTS.
 NOTE: CLEANOUT FOR WASHING MACHINE TO BE LOCATED FOUR
 FEET ABOVE FINNISH FLOOR (4' A.F.F.). PLEASE INDICATE
 THIS ON THE RESUBMITTAL.
  
 ********IMPORTANT INFORMATION
 IN ORDER TO EXPIDITE PLAN REVIEW: WHEN RESUBMITTING,
 PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY. NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop Z ZONING
Rev No 2 Status P Date 2007-04-23 Cont ID  
Sent By adavila Date 2007-04-23 Time 17:14 Rev Time 0.00
Received By adavila Date 2007-04-23 Time 17:14 Sent To I
Notes
2007-04-23 17:14:30PER ERIC SCHNEIDER, PRINCIPAL PLANNER.

Review Stop Z ZONING
Rev No 1 Status F Date 2007-03-05 Cont ID  
Sent By adavila Date 2007-03-05 Time 16:42 Rev Time 0.00
Received By adavila Date 2007-03-05 Time 16:42 Sent To I
Notes
2007-03-05 16:44:41PLANNING AND ZONING DEPARTMENT
  
 ***FAILED***
  
 1.PLEASE PROVIDE RESPONSE TO COMMENTS IN WRITING.
  
 2.PLEASE PROVIDE TWO (2) SIGNED AND SEALED SURVEYS.
 THE SURVEY SHALL BE LESS THAN A YEAR OLD.
  
 3.PLEASE SHOW ALL IMPROVEMENTS ON SITE PLAN.
  
 4.PLEASE PROVIDE ALL SETBACK DIMENSIONS FROM PROPERTY
 LINE ON SITE PLAN.
  
 COMMENTS/QUESTIONS, CONTACT ANDREINA DAVILA Q., OR ERIC
 SCHNEIDER, PRINCIPAL PLANNER, AT 822-1435.