Plan Review Details - Permit 07020548
| Plan Review Stops For Permit 07020548 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2007-04-27 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-04-27 |
Time |
10:29 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-04-27 |
Time |
07:19 |
Sent To |
PC |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-03-08 |
|
|
Cont ID |
|
| Sent By |
mjacobs |
Date |
2007-03-08 |
Time |
10:49 |
Rev Time |
0.00 |
| Received By |
mjacobs |
Date |
2007-03-07 |
Time |
17:29 |
Sent To |
I |
|
| Notes |
| 2007-03-07 19:00:28 | BUILDING PLAN REVIEW | | | PERMIT: | | | ADD: | | | CONT: | | | TEL: (561)###-#### | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | | W/ 2006 FBC REVISIONS | | | * WEST PALM BEACH AMENDMENTS | | | | | | REVIEW | | | ACTION: DENIED | | | | | | 1)--- VERY IMPORTANT STATEMENT --- | | | PLEASE DO NOT IGNORE! | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | | THE REVISION & REMOVE & REPLACE ANY | | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | | BER, WITH A DESCRIPTION OF THE REVISION | | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | 2)PROVIDE INFORMATION FOR TRUSS SYSTEM WHICH IS | | | REFERENCE ON PAG #3. INDICATEWHAT IS IT MADE OF AND | | | HOW IT IS ATTATCHED. | | | ALSO THE ENGINEER HAS ASCE 7-98 ON THE DESIGN | | | PARAMETERS, NOTE: THIS HAS BEEN CHANGED TO ASCE 7-02. | | | MAKE CHANGES ACCORDINGLY. | | | | | | 3)FBC106.1.1CONSTRUCTION DOCUMENTS SHALL BE OF | | | SUFFICIENT CLARITY TO INDICATE RTHE LOCATION, NATURE | | | AND EXTENT OF THE WORK PROPOSED. | | | | | | 4) IN THE GENERAL NOTES THE 2000 ALUMINUM DESIGN MANUAL | | | WAS REFERENCE. | | | NOTE: SEE THE 2004 ALUMINIUM DESIGN MANUALWHICH SHALL | | | BE REFERENCE. IN YOUR NOTES. | | | | | | MYRON JACOBS | | | BUILDING PLAN REVIEWER | | | 805-6726 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
N |
Date |
2007-02-27 |
|
|
Cont ID |
|
| Sent By |
btrobaug |
Date |
2007-02-27 |
Time |
11:29 |
Rev Time |
0.25 |
| Received By |
btrobaug |
Date |
2007-02-27 |
Time |
11:24 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-04-26 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-26 |
Time |
08:50 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-26 |
Time |
08:50 |
Sent To |
B |
|
| Notes |
| 2007-04-26 08:50:44 | TO "MJACOBS" DESK/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-04-12 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-04-12 |
Time |
13:32 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-04-12 |
Time |
13:32 |
Sent To |
Z |
|
| Notes |
| 2007-04-12 13:32:53 | TO "Z" BOX/RESUB |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-03-08 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-03-08 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-03-08 |
Time |
10:54 |
Sent To |
Z |
|
| Notes |
| 2007-03-08 10:54:49 | TO "Z" BOX |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2007-04-30 |
|
|
Cont ID |
|
| Sent By |
jbabcock |
Date |
2007-04-24 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
jbabcock |
Date |
2007-04-30 |
Time |
15:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2007-04-16 |
|
|
Cont ID |
|
| Sent By |
jbabcock |
Date |
2007-03-27 |
Time |
16:54 |
Rev Time |
0.00 |
| Received By |
jbabcock |
Date |
2007-03-27 |
Time |
15:22 |
Sent To |
PC |
|
| Notes |
| 2007-03-27 16:54:19 | PLANNING AND ZONING-FAILED | | | | | | 1. PROVIDE RESPONSE TO COMMENTS IN WRITING. | | | 2. HIGHLIGHT ALL OF THE PROPOSED STRUCTURES ON PLANS. | | | 3. PROVIDE DIMENSIONS FROM PROPOSED SCREEN | | | ENCLOSURE TO THE REAR PROPERTY LINE. | | | | | | FOR ANY ADDITIONAL INFORMATION OR QUESTIONS YOU MAY | | | CONTACT: | | | | | | JULIA BABCOCK | | | PLANNER | | | OFFICE: (561) 822-1442 | | | EMAIL: [email protected] |
|
|
|
Account Summary | Usage Policy | Privacy Policy