Plan Review Details - Permit 07020519
Plan Review Stops For Permit 07020519
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-03-17 Cont ID  
Sent By shill Date 2007-03-17 Time 12:12 Rev Time 0.00
Received By shill Date 2007-03-17 Time 12:12 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2007-03-14 Cont ID  
Sent By shill Date 2007-03-14 Time 09:05 Rev Time 0.00
Received By shill Date 2007-03-14 Time 09:05 Sent To  
Notes
2007-03-14 09:08:48****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* CITY
 OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 1.)OPENING 5, 90INCH SHUTTER SPAN (7.5'),
 INSTALLATION SCHEDULE STATES THAT ANCHOR SPACING IS
 10"TOP, 12" BOTTOM, CONCRETE BLOCK.SEE SHEET 7 OF THE
 PRODUCT APPROVAL.THIS REQUIRES 11" AND 7" FOR C2 AND
 C4.I HAVE HIGHLIGHTED IT ON THE PRODUCT APPROVAL.
 PLEASE CHECK ALL OPENINGS AS IT APPEARS THAT YOU MAY
 HAVE BEEN USING THE WRONG CHART (CONCRETE CHART RATHER
 THAN HOLLOW BLOCK).
  
 2.)PLEASE SUBMIT TWO IDENTIAL SETS OF PERMIT
 DOCUMENTS.TWO INSTALLATION SCHEDULES WERE SUBMITTED,
 BUT ON DIFFERENT FORMS.PLEASE SUBMIT ONLY THE CURRENT
 ONE WITH ALL REQUIRED INFORMATION, AND SUBMIT TWO
 SETS.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2007-03-07 Cont ID  
Sent By shill Date 2007-03-07 Time 15:27 Rev Time 0.00
Received By shill Date 2007-03-07 Time 15:27 Sent To  
Notes
2007-03-07 15:28:31****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC R FLORIDA BUILDING CODE 2004 RESIDENTIAL FBC* CITY
 OF WEST PALM BEACH AMENDMENTS TO THE FBC2004
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED ITEMS APPLY
  
 ____1.A NOTICE OF COMMENCEMENT MUST BE FILED WITH
 THE CLERK OF COURTS BEFORE A PERMIT CAN BE ISSUED,
 FS713.13.
  
 ____2.PROVIDE BUILDING HEIGHT ON THE PLAN.DESIGN
 PRESSURES FOR BUILDINGS OVER 60FEET ARE REQUIRED TO BE
 DESIGNED USING ASCE7, FBC1609.1.1 AND MUST BE DONE BY
 AN ENGINEER. DOCUMENTS PREPARED BY AN ENGINEER AND
 SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED SEALED
 ORIGINALS FAC61G15-23.002.
  
 ____3.PROVIDE A COPY OF THE CONDO ASSOCIATION
 APPROVAL.
  
 _XX_4.COMPLETE THE ATTACHED INSTALLATION SCHEDULE
 OR PROVIDE ALL INFORMATION TO SHOW CODE COMPLIANCE IN
 ANOTHER FORMAT.THE 10" ANCHOR SPACING DOES NOT COMPLY
 WITH ALL CONNECTION TYPES, SEE C1 THROUGH C5.NO
 ANCHOR TYPE OR SUBSTRATE WAS SPECIFIED.
  
 ____5.FLORIDA STATE OR LOCAL PRODUCT APPROVAL
 REQUIRED, FAC9B72, WWW.FLORIDABUILDING.ORG.
  
 ____6.ON THE PRODUCT APPROVAL, MARK WHICH DETAILS
 APPLY TO THIS JOB.PLEASE USE INK RATHER THAN A
 HIGHLIGHTER.
  
 ____7.SHOW THE EMERGENCY MEANS OF ESCAPE, FBC
 R310.
  
 ____8.PROVIDE A FLOOR PLAN SHOWING WHERE THE
 SHUTTERS WILL BE INSTALLED AND PANEL SIZES WHICH
 CORRELATES WITH THE INSTALLATION SCHEDULE, ITEM 4
 ABOVE.
  
 ____9.REVISE EXPOSURE CATEGORY FBC1609.6.2.1(2),
 FBC R301.2.1.4.NOTE THAT THE DEFINITION FOR EXPOSURE
 C HAS CHANGED EFFECTIVE DECEMBER 8, 2006 FBC1609.4, FBC
 R301.2.1.4.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-03-15 Cont ID  
Sent By adarroug Date 2007-03-15 Time 09:56 Rev Time 0.00
Received By adarroug Date 2007-03-15 Time 09:56 Sent To B
Notes
2007-03-15 09:56:24TO "SHILL" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2007-03-10 Cont ID  
Sent By adarroug Date 2007-03-10 Time 14:55 Rev Time 0.00
Received By adarroug Date 2007-03-10 Time 14:55 Sent To B
Notes
2007-03-10 14:55:36TO "SHILL' DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2007-03-07 Cont ID  
Sent By shill Date 2007-03-07 Time 15:28 Rev Time 0.00
Received By shill Date 2007-02-22 Time 14:56 Sent To  
Notes
2007-02-22 14:57:11TO "MISC' BOX#1