Plan Review Details - Permit 07020506
| Plan Review Stops For Permit 07020506 |
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2007-05-14 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-05-14 |
Time |
10:04 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2007-05-14 |
Time |
10:04 |
Sent To |
PC |
|
| Notes |
| 2007-05-14 10:12:57 | REVISION: NEW LAYOUT WITH ALL NEW PIPING DUE TO DAMAGED | | | EXISTING. | | | | | | ****************PROVISO**************** | | | IF DRYER ROOM IS A CONFINED SPACE, OPEN- | | | INGS REQUIRED PER SECTION 304.5 OR | | | SECTION 304.6 SHALL BE INSTALLED. | | | MINIMUM 1,100 CUBIC FEET REQUIRED. | | | | | | A} PER FBC-2004 FUEL GAS, SECTION 404.13.3AN | | | INSULATED COPPER TRACER WIRE SHALL BE INSTALLED | | | ADJACENT TO UNDERGROUND NONMETALLIC GAS PIPING. THE | | | TRACER WIRE SIZE SHALL NOT BE LESS THAN 18 AWG AND THE | | | INSULATION TYPE SHALL BE SUITABLE FOR DIRECT BURIAL. | | | | | | B} FBC-2004 FUEL GAS SEC. 404.12 OUTLET | | | CLOSURES: GAS OUTLETS THAT DO NOT CON- | | | NECT TO APPLIANCES SHALL BE CAPPED GAS | | | TIGHT. |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2007-04-17 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-04-17 |
Time |
15:38 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2007-04-17 |
Time |
15:38 |
Sent To |
PC |
|
| Notes |
| 2007-04-17 15:52:12 | REVISION DENIED | | | REFERENCE: | | | ** FBC-2004 FUEL GAS. | | | ** THE CITY OF WEST PALM BEACH GAS PERMIT APPLICATION | | | REQUIREMENTS. | | | ** FBC-2004 CHAPTER 1, THE CITY OF | | | WEST PALM BEACH AMENDMENTS. | | | | | | THE FOLLOWING CORRECTIONS/INFORMATION ARE REQUIRED FOR | | | GAS REVISION PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | | | 1. CLEARLY INDICATE ON THE RESUBMITTED REVISION THE | | | EXISTING PIPING AND THE NEW PIPING. | | | | | | 2. PLEASE INDICATE THE FOLLOWING FOR THE FUTURE | | | GRILL: | | | | | | A} BTU LOAD FOR THE FUTURE GRILL. | | | B} PIPE SIZES FOR THE FUTURE GRILL. | | | C} PLEASE INDICATE THE PIPING FOR THE FUTURE GRILL AS | | | NEW BECAUSE THERE IS NO INDICATION OF A GRILL ON THE | | | PERMITTED FILE COPY PRINT. | | | | | | 3. PLEASE CORRECT THE TOTAL BTU LOAD TO REFLECT THE | | | ADDED BTU LOAD OF THE FUTURE GRILL. | | | | | | END OF COMMENTS: | | | | | | REVIEW BY MIKE PERSON | | | (561) 805-6730 | | | FAX (561) 805-6731 | | | E-MAIL [email protected] | | | UNDER SUPERVISION OF K.STEVENS | | | (561) 805-6721 | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2007-02-27 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-02-27 |
Time |
08:26 |
Rev Time |
0.45 |
| Received By |
mperson |
Date |
2007-02-27 |
Time |
08:26 |
Sent To |
PC |
|
| Notes |
| 2007-02-27 08:44:15 | | | | IF DRYER ROOM IS A CONFINED SPACE, OPEN- | | | INGS REQUIRED PER SECTION 304.5 OR | | | SECTION 304.6 SHALL BE INSTALLED. | | | MINIMUM 1,500 CUBIC FEET REQUIRED. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2007-05-04 |
|
|
Cont ID |
|
| Sent By |
adarroug |
Date |
2007-05-04 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
adarroug |
Date |
2007-05-04 |
Time |
13:20 |
Sent To |
G |
|
| Notes |
| 2007-05-04 13:20:24 | TO "G" BOX/REV |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2007-04-03 |
|
|
Cont ID |
|
| Sent By |
spalmer |
Date |
2007-04-03 |
Time |
17:08 |
Rev Time |
0.00 |
| Received By |
spalmer |
Date |
2007-04-03 |
Time |
17:08 |
Sent To |
G |
|
| Notes |
| 2007-04-03 17:08:39 | TO MIKE PERSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2007-02-27 |
|
|
Cont ID |
|
| Sent By |
mperson |
Date |
2007-02-27 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
mperson |
Date |
2007-02-22 |
Time |
13:41 |
Sent To |
|
|
| Notes |
| 2007-02-22 13:41:28 | TO "G" BOX |
|
|
|