Plan Review Details - Permit 07020461
| Plan Review Stops For Permit 07020461 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2007-03-26 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-03-26 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-03-26 |
Time |
16:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2007-03-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-03-16 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-03-16 |
Time |
11:00 |
Sent To |
|
|
| Notes |
| 2007-03-16 11:37:23 | DENIED BY BUILDING | | | | | | 1) THE VALUE OF THE WORK HAS BEEN INCREASED TO | | | $20,431.00. ADDITIONAL FEES ARE DUE. | | | | | | 2) THE FLAT ROOF ASSEMBLY ON PAGE 38 THAT WAS SELECTED | | | FROM THE POLYGLASS NOA HAS A DESIGN PRESSURE OF -45 PSF | | | WHICH IS TOO LOW FOR ROOF ZONES 2 AND 3. IT ALSO HAS | | | GENERAL LIMITATION #9 WHICH DOES NOT ALLOW THE LISTED | | | DESIGN PRESSURE TO BE INCREASED. SEE PAGE 44 OF THE | | | NOA. | | | | | | NOTE: SOME OF THE ASSEMBLIES IN THE NOA DO ALLOW | | | ENHANCED FASTENING TO ACHIEVE HIGHER DESIGN PRESSURES, | | | HOWEVER THEY REQUIRE SIGNED AND SEALED RAS 117 | | | CALCULATIONS FROM A FLORIDA REGISTERED ARCHITECT OR | | | ENGINEER. SEE LIMITATION #7 ON PAGE 44 OF THE NOA. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2007-02-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2007-02-16 |
Time |
17:45 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2007-02-16 |
Time |
17:29 |
Sent To |
|
|
| Notes |
| 2007-02-16 17:44:52 | DENIED BY BUILDING | | | | | | 1) THE VALUE OF JOB IS LOW. PLEASE ADJUST OR WE WILL | | | ASSIGN A NEW VALUE. | | | | | | 2)SUBMIT PRODUCT APPROVALS FOR THE FLAT ROOF SYSTEM | | | THAT WILL BE USED. SPECIFY THE APPROVED SYSTEM, THE | | | FASTENING OPTION AND THE MAXIMUM DESIGN PRESSURE. | | | CIRCLE THE APPROPRIATE ITEMS ON THE PRODUCT APPROVAL. | | | IF ENHANCED FASTENING IS REQUIRED SUBMIT THE RAS 117 | | | CALCULATIONS. | | | | | | 3)PRODUCT APPROVALS SUBMITTED WITH | | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | | PLEASE SEE THE STATE WEBSITE AT | | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | | SUBMITTED WITH A COVER SHEET THAT LISTS | | | THE PRODUCT IDENTITY NUMBER FROM THE | | | STATE. | | | | | | 4)A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)805-6714 |
|
|
|